SLAC Magnetic Measurements Date: 02-22-2010 Time: 10:48:43 Planar Insertion Device Analysis -------------------------------- Data File Header: SLAC Magnetic Measurements Date: 02-22-2010 Time: 10:42:15 Project: LCLS Device Type: Undulator Data Type: Serial Number: L143-112000-20 DATASET Number: 7 Tuning Stage: Fine Tuning Run Number: 4 Measurement Type: Z Scans Operator: YL Comment: find first pole position Session first run: 4 Measurement Device x: Measurement Device y: SENTRON_441 Data File: s:\magdata\LCLS\Undulator\L143-112000-20\DATASET0007\Fine Tuning\Z Scans\Run 004\bscanz.dat Temperature (C) L143-112000-20:--> T5 20.10 --> T2 20.12 --> T1 20.04 --> T3 20.04 --> Air 20.10 --> T4 20.10 Axes position (m) X:0.028571 Y:0.000360 Initial Hall Probe Zero Measurements: Vx_0i = 0.001391 V Vy_0i = -0.001809 V Final Hall Probe Zero Measurements: Vx_0f = 0.001310 V Vy_0f = -0.001849 V Offset Correction Voff = offset+index*increment index = 0,1...21250 Vx:offset = 0.001391 V, increment = -3.844E-09 V Vy:offset = -0.001809 V, increment = -1.879E-09 V Hall Probe Calibration File: Y: c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat Reference Magnet Measurements: Bx_ref = 0.0000xx (T) By_ref = 0.0000xx (T) Magnetic Field Measurements vs Z Analysis Parameters: Input file directory = s:\magdata\LCLS\Undulator\L143-112000-20\DATASET0007\Fine Tuning\Z Scans\Run 004\ Input file name = x+00000_y+000_bscanz.dat Input file type = ZVXYBXYH Correction required = 1 Correction, Bx multiplicative factor = 1.000000 Correction, By multiplicative factor = 1.000000 Correction, Bx additive constant = -0.000010 T Correction, By additive constant = -0.000008 T Correction Bxy additive file = none Correction Bxy additive file type = CORR_ZBXY Electron gamma = 26629.140000 Electron energy = 13.607466 Gev Nominal undulator period = 0.030000 m Nominal K value = 2.253198 Nominal radiation wavelength = 7.484971e-011 m Number of undulator poles = 226 Number of end poles (used in analysis) = 4 Cell length = 3.656000 m Nominal phase change through cell = 709.999940 rad Nominal phase of pole after end poles = 14.137167 rad Save as final result = 0 Result file directory = c:\magdata\slac_und_2\ Result file name = zscan_xn0060yp0002.dat Figures close on exit = 0 Figures visible = 1 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! The Measured Fields Were Corrected: Bx_corr = CORR_BX_MULT * Bx + CORR_BX_ADD + CORR_BX_ADD_FILE By_corr = CORR_BY_MULT * By + CORR_BY_ADD + CORR_BY_ADD_FILE Parameters: CORR_BX_MULT = 1.000000 CORR_BY_MULT = 1.000000 CORR_BX_ADD = -0.000010 T CORR_BY_ADD = -0.000008 T CORR_BX_ADD_FILE = none CORR_BY_ADD_FILE = none !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Peak And Zero Field Summary: Number of Poles = 226 Number of End Poles (excluded in statistics) = 4 Peak Fields: Ave = 0.811126 T, RMS = 0.003256 T Peak Field Spacing: Ave = 0.014999 m, RMS = 0.000022 m Zero Field Spacing: Ave = 0.014999 m, RMS = 0.000039 m Average Undulator Period = 0.029998 m Hall Probe Overall Field Integrals: Int Bx dz = -8.2822e-006 Tm Int Int Bx dz dz = -1.2470e-005 Tm^2 Int By dz = -2.1704e-004 Tm Int Int By dz dz = -6.8999e-004 Tm^2 Trajectory Exit Information: X at exit = -1.5202e-005 m X slope at exit = -4.7818e-006 Y at exit = 2.7474e-007 m Y slope at exit = 1.8247e-007 Calculated Undulator Parameters: Keff = 2.258049 Beff = 0.806161 T Lambda_rad = 7.507594e-011 m Calculated K Value At 20 C: (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 20.075000 C Measured Keff = 2.258049 Calculated Keff at 20 C = 2.258134 Relative Change (Keff_20C - Keff) / Keff = 0.000037 Phase Fluctuations: Slippage vs Z At Peaks Fitted Slope = 2.50271e-009 Undulator Period = 0.029998 m Radiation Wavelength = 7.50759e-011 m Phase Error (From Slippage vs Z Fit Residuals): Ave = 0.000000 deg, Phase error RMS = 23.763603 deg Phase Relative To Nominal Radiation Wave: Nominal Radiation Wavelength = 7.48497e-011 m Cell Length = 3.656000 m Number Of End Poles = 4 Entrance: Phase Error Of First 10 Poles After The End Poles Ave = 347.033424 deg, RMS = 8.650858 deg Center: Phase Error Of All Poles In Undulator Center: Ave = 369.556152 deg, RMS = 41.843907 deg Exit: Phase Error To Cell Boundary Of Last 10 Poles Before The End Poles Ave = 356.226512 deg, RMS = 17.551495 deg Cell: Phase Change Of Cell = 41497.939 deg Nominal Phase Change Of Cell = 40680.000 deg Phase Error Of Cell = 817.939 deg Calculated Phase Change In The Cell At 20 C: (Relative to the nominal radiation wave) (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 20.075000 C Measured Phase Change Of Cell = 41497.939 deg Calculated Phase Change Of Cell At 20 C = 41500.175 deg Phase Change Due To Temperature (Phase_20C - Phase) = 2.235 deg