SLAC Magnetic Measurements Date: 08-01-2012 Time: 15:46:14 Planar Insertion Device Analysis -------------------------------- Data File Header: SLAC Magnetic Measurements Date: 08-01-2012 Time: 15:41:55 Project: LCLS Device Type: Undulator Data Type: Serial Number: L143-112000-15 DATASET Number: 6 Tuning Stage: Fine Tuning Run Number: 13 Measurement Type: Z Scans Operator: YL Comment: at min K; second gap adjustment Session first run: 12 Measurement Device x: Measurement Device y: SENTRON_441 Data File: s:\magdata\LCLS\Undulator\L143-112000-15\DATASET0006\Fine Tuning\Z Scans\Run 013\bscanz.dat Temperature (C) L143-112000-15:--> T1 19.95 --> T2 19.95 --> T5 19.96 --> T3 19.96 --> Air 19.98 --> T4 19.98 Axes position (m) X:0.030213 Y:0.000223 Initial Hall Probe Zero Measurements: Vx_0i = 0.000951 V Vy_0i = -0.003054 V Final Hall Probe Zero Measurements: Vx_0f = 0.000920 V Vy_0f = -0.003127 V Offset Correction Voff = offset+index*increment index = 0,1...21250 Vx:offset = 0.000951 V, increment = -1.440E-09 V Vy:offset = -0.003054 V, increment = -3.426E-09 V Hall Probe Calibration File: Y: c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat Reference Magnet Measurements: Bx_ref = 0.0000xx (T) By_ref = 0.0000xx (T) Magnetic Field Measurements vs Z Analysis Parameters: Input file directory = s:\magdata\LCLS\Undulator\L143-112000-15\DATASET0006\Fine Tuning\Z Scans\Run 013\ Input file name = x+00000_y+000_bscanz.dat Input file type = ZVXYBXYH Correction required = 1 Correction, Bx multiplicative factor = 1.000000 Correction, By multiplicative factor = 1.000000 Correction, Bx additive constant = -0.000002 T Correction, By additive constant = 0.000002 T Correction Bxy additive file = none Correction Bxy additive file type = CORR_ZBXY Electron gamma = 26623.020000 Electron energy = 13.604338 Gev Nominal undulator period = 0.030000 m Nominal K value = 3.484902 Nominal radiation wavelength = 1.496703e-010 m Number of undulator poles = 226 Number of end poles (used in analysis) = 4 Cell length = 3.656000 m Nominal phase change through cell = 709.999940 rad Nominal phase of pole after end poles = 14.137167 rad Save as final result = 0 Result file directory = c:\magdata\slac_und_2\ Result file name = zscan_xn0060yp0002.dat Figures close on exit = 0 Figures visible = 1 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! The Measured Fields Were Corrected: Bx_corr = CORR_BX_MULT * Bx + CORR_BX_ADD + CORR_BX_ADD_FILE By_corr = CORR_BY_MULT * By + CORR_BY_ADD + CORR_BY_ADD_FILE Parameters: CORR_BX_MULT = 1.000000 CORR_BY_MULT = 1.000000 CORR_BX_ADD = -0.000002 T CORR_BY_ADD = 0.000002 T CORR_BX_ADD_FILE = none CORR_BY_ADD_FILE = none !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Peak And Zero Field Summary: Number of Poles = 226 Number of End Poles (excluded in statistics) = 4 Peak Fields: Ave = 1.272556 T, RMS = 0.004678 T Peak Field Spacing: Ave = 0.014998 m, RMS = 0.000021 m Zero Field Spacing: Ave = 0.014999 m, RMS = 0.000033 m Average Undulator Period = 0.029997 m Hall Probe Overall Field Integrals: Int Bx dz = 1.9864e-005 Tm Int Int Bx dz dz = 2.1755e-006 Tm^2 Int By dz = -9.1675e-006 Tm Int Int By dz dz = 4.8386e-006 Tm^2 Trajectory Exit Information: X at exit = 1.0663e-007 m X slope at exit = -2.0202e-007 Y at exit = -4.7940e-008 m Y slope at exit = -4.3773e-007 Calculated Undulator Parameters: Keff = 3.488096 Beff = 1.245331 T Lambda_rad = 1.498926e-010 m Calculated K Value At 20 C: (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 19.955000 C Measured Keff = 3.488096 Calculated Keff at 20 C = 3.488028 Relative Change (Keff_20C - Keff) / Keff = -0.000019 Phase Fluctuations: Slippage vs Z At Peaks Fitted Slope = 4.99686e-009 Undulator Period = 0.029997 m Radiation Wavelength = 1.49893e-010 m Phase Error (From Slippage vs Z Fit Residuals): Ave = -0.000000 deg, Phase error RMS = 6.311389 deg Phase Relative To Nominal Radiation Wave: Nominal Radiation Wavelength = 1.49670e-010 m Cell Length = 3.656000 m Number Of End Poles = 4 Entrance: Phase Error Of First 10 Poles After The End Poles Ave = 14.389878 deg, RMS = 2.925706 deg Center: Phase Error Of All Poles In Undulator Center: Ave = 36.463910 deg, RMS = 18.002570 deg Exit: Phase Error To Cell Boundary Of Last 10 Poles Before The End Poles Ave = 12.838909 deg, RMS = 4.024666 deg Cell: Phase Change Of Cell = 40764.767 deg Nominal Phase Change Of Cell = 40680.000 deg Phase Error Of Cell = 84.767 deg Calculated Phase Change In The Cell At 20 C: (Relative to the nominal radiation wave) (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 19.955000 C Measured Phase Change Of Cell = 40764.767 deg Calculated Phase Change Of Cell At 20 C = 40763.192 deg Phase Change Due To Temperature (Phase_20C - Phase) = -1.575 deg