SLAC Magnetic Measurements
Date: 08-24-2012
Time: 10:03:06

Project: LCLS
Device Type: Undulator
Data Type: 
Serial Number: L143-112000-15
DATASET Number: 6
Tuning Stage: Fine Tuning
Run Number: 8
Measurement Type: Align X Scan
Operator: YL
Comment: find yaw and Xm
 Device:HP3458 , integration time = 0.060000 , number of channels = 1, number of samples = 37888, range = 5.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.060000 , number of channels = 1, number of samples = 0, range = 5.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.060000 , number of channels = 1, number of samples = 0, range = 3.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.060000 , number of channels = 1, number of samples = 0, range = 3.000000
*------------------------------------------------------------------------------*
10:03:14  Stage Zeroed
10:03:14 Move node 0:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
10:03:14 Move node 1:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
10:03:14 Move node 2:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
10:03:14 Move node 3:  Move Device = NONE, Read Device = NONE
*****************************************************************
------------------> get_data <----------------------
10:03:15 : humidity :  52.02
------------------> get_data <----------------------
10:03:15 : pressure : 1000.51
------------------> get_data <----------------------
10:03:15 : ambient : --> Ambient 19.89 --> KGranite 19.97 --> KRefM 19.98 
------------------> get_data <----------------------
10:03:15 : L143-112000-15 : --> T1 20.09 --> T2 20.07 --> T5 20.03 --> T3 20.07 --> Air 20.01 --> T4 20.06 

BSCANX: :  --== BscanX started ==--
 	 at 08-24-2012 10:03:20	 
Initial first pole position = 0.962032	 
Ycenter = 0.000000
BSCANX: : Calibration is up to date.
BSCANX: : CALIBRATION FILE:	 c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini	 c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat
BSCANX: : CALIBRATION PROBE:	 poly_calib

BSCANX: : Zero field Y at start-> voltage:-0.003094	field: -0.000620T
BSCANX: : Zero field X at start-> voltage:0.000000	field: 0.000000T
 PXI axis 1: mode = 0 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 5201
scans number = 0, threshold = 5200, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 3: mode = 1 , counts per index = 250000
 microns per count = 1.000000, indices = 1:19
multiple of counts = 20 , number of samples = 30000
scans number = 45, threshold = 29999, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 2: mode = 1 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 400
scans number = 0, threshold = 399, zero index = 1
<------------------------------------------------------------------------------>
10:03:26  Move:node 1 absolute position = 0.000400 m
10:03:31  Move:node 2 absolute position = 0.100000 m

Position (counts) fixed:600, secondary:37062
10:03:43  Move:node 1 position incremented by = -0.000297 m

Position (counts) fixed:6, secondary:37062
10:03:48  Move:node 1 position incremented by = -0.000003 m

Position (counts) fixed:0, secondary:37062
10:03:57  Move:node 2 position incremented by = 0.924970 m
	 
10:04:18  Move:node 0 absolute position = 0.059000 m
10:04:39  Stage Position Measurement, pos = 0.059000 m
10:04:39  Move:node 0 absolute position = 0.000000 m
