SLAC Magnetic Measurements
Date: 04-23-2015
Time: 10:15:49

Project: LCLS
Device Type: Undulator
Data Type: 
Serial Number: L143-112000-13
DATASET Number: 49
Tuning Stage: Fine Tuning
Run Number: 8
Measurement Type: Align X Scan
Operator: YL
Comment: alignment 
 Device:HP3458 , integration time = 0.060000 , number of channels = 1, number of samples = 37888, range = 5.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.060000 , number of channels = 1, number of samples = 0, range = 5.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.060000 , number of channels = 1, number of samples = 0, range = 3.000000
*------------------------------------------------------------------------------*
 Device:NONE , integration time = 0.060000 , number of channels = 1, number of samples = 0, range = 3.000000
*------------------------------------------------------------------------------*
10:16:23  Stage Zeroed
10:16:23 Move node 0:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
10:16:23 Move node 1:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
10:16:23 Move node 2:  Move Device = UMAC, Read Device = UMAC
*****************************************************************
10:16:23 Move node 3:  Move Device = NONE, Read Device = NONE
*****************************************************************
------------------> get_data <----------------------
10:16:23 : humidity :  36.35
------------------> get_data <----------------------
10:16:23 : pressure : 1000.39
------------------> get_data <----------------------
10:16:23 : ambient : --> Ambient 20.34 
------------------> get_data <----------------------
10:16:23 : L143-112000-13 : --> T1 20.07 --> T2 20.08 --> T5 20.07 --> T3 20.08 --> Air 20.09 --> T4 20.09 --> KRefM 19.89 

BSCANX: :  --== BscanX started ==--
 	 at 04-23-2015 10:16:27	 
Initial first pole position = 0.962010	 
Ycenter = 0.000252
BSCANX: : Calibration is up to date.
BSCANX: : CALIBRATION FILE:	 c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini	 c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat
BSCANX: : CALIBRATION PROBE:	 poly_calib

BSCANX: : Zero field Y at start-> voltage:-0.003250	field: -0.000651T
BSCANX: : Zero field X at start-> voltage:0.000000	field: 0.000000T
 PXI axis 1: mode = 0 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 5201
scans number = 0, threshold = 5200, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 3: mode = 1 , counts per index = 250000
 microns per count = 1.000000, indices = 1:19
multiple of counts = 20 , number of samples = 30000
scans number = 45, threshold = 29999, zero index = 1
<------------------------------------------------------------------------------>
 PXI axis 2: mode = 1 , counts per index = 20000
 microns per count = 0.500000, indices = 1:2
multiple of counts = 20 , number of samples = 400
scans number = 0, threshold = 399, zero index = 1
<------------------------------------------------------------------------------>
10:16:34  Move:node 1 absolute position = 0.000400 m
10:16:39  Move:node 2 absolute position = 0.100000 m

Position (counts) fixed:600, secondary:37074
10:16:51  Move:node 1 position incremented by = -0.000048 m

Position (counts) fixed:504, secondary:37074
10:16:59  Move:node 2 position incremented by = 0.924936 m
	 
10:17:20  Move:node 0 absolute position = 0.059000 m
10:17:20  Stage Position Measurement, pos = -0.000000 m
10:17:20  Move:node 0 absolute position = 0.000000 m