SLAC Magnetic Measurements Date: 04-15-2013 Time: 16:55:31 Planar Insertion Device Analysis -------------------------------- Data File Header: SLAC Magnetic Measurements Date: 04-15-2013 Time: 16:51:42 Project: LCLS Device Type: Undulator Data Type: Serial Number: DELTA DATASET Number: 1 Tuning Stage: Fine Tuning Run Number: 43 Measurement Type: Z Scans Operator: YL Comment: Q1; #75 down 0.025mm Session first run: 42 Measurement Device x: Measurement Device y: SENTRON_441 Data File: s:\magdata\LCLS\Undulator\DELTA\DATASET0001\Fine Tuning\Z Scans\Run 043\bscanz.dat Temperature (C) DELTA:--> T1 19.96 --> T2 20.25 --> T5 19.88 --> T3 19.95 --> Air 20.00 --> T4 19.96 Axes position (m) X:0.020025 Y:0.000025 Initial Hall Probe Zero Measurements: Vx_0i = 0.000822 V Vy_0i = -0.003517 V Final Hall Probe Zero Measurements: Vx_0f = 0.000760 V Vy_0f = -0.003571 V Offset Correction Voff = offset+index*increment index = 0,1...8750 Vx:offset = 0.000822 V, increment = -7.178E-09 V Vy:offset = -0.003517 V, increment = -6.170E-09 V Hall Probe Calibration File: Y: c:\CVI\current_calib\Sentron_441\Sentron_441_y.ini X: c:\cvi\current_calib\HALLx_calib_poly_fit_file.dat Reference Magnet Measurements: Bx_ref = 0.0000xx (T) By_ref = 0.0000xx (T) Magnetic Field Measurements vs Z Analysis Parameters: Input file directory = s:\MagData\LCLS\Undulator\DELTA\DATASET0001\Fine Tuning\Z Scans\Run 043\ Input file name = x+00000_y+000_bscanz.dat Input file type = ZVXYBXYH Correction required = 1 Correction, Bx multiplicative factor = 1.000000 Correction, By multiplicative factor = 1.000000 Correction, Bx additive constant = -0.000020 T Correction, By additive constant = 0.000035 T Correction Bxy additive file = none Correction Bxy additive file type = CORR_ZBXY Electron gamma = 26638.000000 Electron energy = 13.611993 Gev Nominal undulator period = 0.032000 m Nominal K value = 1.237440 Nominal radiation wavelength = 3.981220e-011 m Number of undulator poles = 60 Number of end poles (used in analysis) = 4 Cell length = 3.656000 m Nominal phase change through cell = 709.999940 rad Nominal phase of pole after end poles = 274.889357 rad Save as final result = 0 Result file directory = c:\magdata\slac_und_2\ Result file name = zscan_xn0060yp0002.dat Figures close on exit = 0 Figures visible = 1 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! The Measured Fields Were Corrected: Bx_corr = CORR_BX_MULT * Bx + CORR_BX_ADD + CORR_BX_ADD_FILE By_corr = CORR_BY_MULT * By + CORR_BY_ADD + CORR_BY_ADD_FILE Parameters: CORR_BX_MULT = 1.000000 CORR_BY_MULT = 1.000000 CORR_BX_ADD = -0.000020 T CORR_BY_ADD = 0.000035 T CORR_BX_ADD_FILE = none CORR_BY_ADD_FILE = none !!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Peak And Zero Field Summary: Number of Poles = 60 Number of End Poles (excluded in statistics) = 4 Peak Fields: Ave = 0.429911 T, RMS = 0.007709 T Peak Field Spacing: Ave = 0.016153 m, RMS = 0.000222 m Zero Field Spacing: Ave = 0.016155 m, RMS = 0.000123 m Average Undulator Period = 0.032308 m Hall Probe Overall Field Integrals: Int Bx dz = 2.5540e-005 Tm Int Int Bx dz dz = 3.6763e-005 Tm^2 Int By dz = -2.5451e-005 Tm Int Int By dz dz = -1.9143e-005 Tm^2 Trajectory Exit Information: X at exit = -4.2161e-007 m X slope at exit = -5.6054e-007 Y at exit = -8.0968e-007 m Y slope at exit = -5.6249e-007 Calculated Undulator Parameters: Keff = 1.318452 Beff = 0.437053 T Lambda_rad = 4.255227e-011 m Calculated K Value At 20 C: (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 20.010000 C Measured Keff = 1.318452 Calculated Keff at 20 C = 1.318458 Relative Change (Keff_20C - Keff) / Keff = 0.000004 Phase Fluctuations: Slippage vs Z At Peaks Fitted Slope = 1.31708e-009 Undulator Period = 0.032308 m Radiation Wavelength = 4.25523e-011 m Phase Error (From Slippage vs Z Fit Residuals): Ave = -0.000000 deg, Phase error RMS = 5.979588 deg Phase Relative To Nominal Radiation Wave: Nominal Radiation Wavelength = 3.98122e-011 m Cell Length = 3.656000 m Number Of End Poles = 4 Entrance: Phase Error Of First 10 Poles After The End Poles Ave = -6372.517775 deg, RMS = 37.024765 deg Center: Phase Error Of All Poles In Undulator Center: Ave = -6108.538344 deg, RMS = 188.018983 deg Exit: Phase Error To Cell Boundary Of Last 10 Poles Before The End Poles Ave = -6380.548663 deg, RMS = 29.957175 deg Cell: Phase Change Of Cell = 28445.054 deg Nominal Phase Change Of Cell = 40680.000 deg Phase Error Of Cell = -12234.946 deg Calculated Phase Change In The Cell At 20 C: (Relative to the nominal radiation wave) (Assumes Keff changes by -.05% per degree C) Measured Average Undulator Temperature = 20.010000 C Measured Phase Change Of Cell = 28445.054 deg Calculated Phase Change Of Cell At 20 C = 28445.186 deg Phase Change Due To Temperature (Phase_20C - Phase) = 0.132 deg