SLAC Magnetic Measurements Date: 03-09-2006 Time: 13:23:46 Project: LCLS Magnet Type: Solenoid Magnet Name: Stangenes_2 Serial Number: Run Number: 1 Measurement Device: Coil 2 Operator: sda Comment: Harmonics at 15 A. Stdzed. z = 0 is outside of ring on non power lead side Standardization: 4 cycles from 0.0 A to 30.0 A to 0.0 A Test Currents (A): 15.0 13:24:03 Vcoil, device being used, type = SR850 13:24:25 Stage Zeroed 13:24:25 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 13:24:26 Initial Zero Current Measurement, Imag_zero = 0.0000 A 13:24:26 Magnet current ramping to 30.0000 A... 13:24:59 Magnet current ramping to 0.0000 A... 13:25:32 Magnet current ramping to 30.0000 A... 13:26:06 Magnet current ramping to 0.0000 A... 13:26:38 Magnet current ramping to 30.0000 A... 13:27:12 Magnet current ramping to 0.0000 A... 13:27:44 Magnet current ramping to 30.0000 A... 13:28:18 Magnet current ramping to 0.0000 A... 13:28:51 Magnet current ramping to 15.0000 A... 13:30:00 Move Stage, position = -0.210000 13:30:02 Stage Position Measurement, pos = -0.2101950 m 13:30:04 Magnet Current, Imag = 14.9787 A Vtrans = 0.149787 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:30:06 Coil Rotation Frequency Measurement freq = 13.078200 Hz 13:35:19 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0006727 74.424 2 0.0000115 117.522 3 0.0000107 -82.032 4 0.0000097 130.812 13:35:31 Move Stage, position = -0.180000 13:35:33 Stage Position Measurement, pos = -0.1809250 m 13:35:35 Magnet Current, Imag = 14.9748 A Vtrans = 0.149748 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:37 Coil Rotation Frequency Measurement freq = 13.072000 Hz 13:40:56 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0005567 77.406 2 0.0000132 136.278 3 0.0000114 -100.116 4 0.0000075 113.748 13:41:08 Move Stage, position = -0.150000 13:41:10 Stage Position Measurement, pos = -0.1508800 m 13:41:12 Magnet Current, Imag = 14.9828 A Vtrans = 0.149828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:14 Coil Rotation Frequency Measurement freq = 13.089700 Hz 13:47:34 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0006096 79.338 2 0.0000216 -180.000 3 0.0000330 -116.346 4 0.0000054 90.000 13:47:46 Move Stage, position = -0.120000 13:47:48 Stage Position Measurement, pos = -0.1209250 m 13:47:50 Magnet Current, Imag = 14.9870 A Vtrans = 0.149870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:52 Coil Rotation Frequency Measurement freq = 13.094900 Hz 13:52:57 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0006730 81.744 2 0.0000250 148.380 3 0.0000473 -97.506 4 0.0000225 48.816 13:53:09 Move Stage, position = -0.090000 13:53:10 Stage Position Measurement, pos = -0.0908800 m 13:53:12 Magnet Current, Imag = 14.9867 A Vtrans = 0.149867 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:14 Coil Rotation Frequency Measurement freq = 13.092000 Hz 13:58:50 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0008556 86.742 2 0.0000344 148.494 3 0.0001096 -113.058 4 0.0000334 54.804 13:59:02 Move Stage, position = -0.060000 13:59:04 Stage Position Measurement, pos = -0.0607800 m 13:59:06 Magnet Current, Imag = 14.9848 A Vtrans = 0.149848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:08 Coil Rotation Frequency Measurement freq = 13.085800 Hz 14:03:45 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0013157 90.462 2 0.0000475 136.554 3 0.0001595 -119.880 4 0.0000478 42.606 14:03:57 Move Stage, position = -0.030000 14:03:58 Stage Position Measurement, pos = -0.0307550 m 14:04:00 Magnet Current, Imag = 14.9845 A Vtrans = 0.149845 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:02 Coil Rotation Frequency Measurement freq = 13.087700 Hz 14:09:00 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0022889 92.964 2 0.0000722 118.074 3 0.0002455 -105.042 4 0.0000789 40.746 14:09:12 Move Stage, position = 0.000000 14:09:13 Stage Position Measurement, pos = -0.0007200 m 14:09:15 Magnet Current, Imag = 14.9831 A Vtrans = 0.149831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:17 Coil Rotation Frequency Measurement freq = 13.093500 Hz 14:14:14 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0034507 101.610 2 0.0001113 92.646 3 0.0004235 -114.870 4 0.0000978 38.976 14:14:26 Move Stage, position = 0.030000 14:14:28 Stage Position Measurement, pos = 0.0293400 m 14:14:30 Magnet Current, Imag = 14.9838 A Vtrans = 0.149838 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:32 Coil Rotation Frequency Measurement freq = 13.090100 Hz 14:19:05 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0043937 118.614 2 0.0001568 66.516 3 0.0004397 -115.674 4 0.0001127 38.058 14:19:17 Move Stage, position = 0.060000 14:19:19 Stage Position Measurement, pos = 0.0593100 m 14:19:21 Magnet Current, Imag = 14.9827 A Vtrans = 0.149827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:23 Coil Rotation Frequency Measurement freq = 13.093500 Hz 14:23:55 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0055101 133.128 2 0.0002021 49.218 3 0.0007071 -115.926 4 0.0001214 47.514 14:24:07 Move Stage, position = 0.090000 14:24:09 Stage Position Measurement, pos = 0.0893150 m 14:24:11 Magnet Current, Imag = 14.9822 A Vtrans = 0.149822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:13 Coil Rotation Frequency Measurement freq = 13.094900 Hz 14:28:42 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0063416 145.158 2 0.0002137 46.884 3 0.0005584 -127.128 4 0.0001268 36.390 14:28:54 Move Stage, position = 0.120000 14:28:55 Stage Position Measurement, pos = 0.1194150 m 14:28:57 Magnet Current, Imag = 14.9813 A Vtrans = 0.149813 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:59 Coil Rotation Frequency Measurement freq = 13.094900 Hz 14:33:11 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0067034 147.642 2 0.0001806 54.738 3 0.0008401 -113.478 4 0.0001896 39.684 14:33:23 Move Stage, position = 0.150000 14:33:24 Stage Position Measurement, pos = 0.1494800 m 14:33:26 Magnet Current, Imag = 14.9827 A Vtrans = 0.149827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:28 Coil Rotation Frequency Measurement freq = 13.098700 Hz 14:37:38 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0067526 146.202 2 0.0001832 60.084 3 0.0009069 -106.608 4 0.0002625 55.470 14:37:50 Move Stage, position = 0.180000 14:37:52 Stage Position Measurement, pos = 0.1795250 m 14:37:54 Magnet Current, Imag = 14.9790 A Vtrans = 0.149790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:56 Coil Rotation Frequency Measurement freq = 13.079600 Hz 14:42:03 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0066957 143.850 2 0.0002409 57.606 3 0.0008413 -112.734 4 0.0002505 44.148 14:42:15 Move Stage, position = 0.210000 14:42:17 Stage Position Measurement, pos = 0.2095750 m 14:42:19 Magnet Current, Imag = 14.9782 A Vtrans = 0.149782 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:42:21 Coil Rotation Frequency Measurement freq = 13.082000 Hz 14:46:42 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0064853 138.966 2 0.0002757 57.690 3 0.0007445 -102.762 4 0.0002343 45.408 14:46:54 Move Stage, position = 0.240000 14:46:55 Stage Position Measurement, pos = 0.2395750 m 14:46:57 Magnet Current, Imag = 14.9784 A Vtrans = 0.149784 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:46:59 Coil Rotation Frequency Measurement freq = 13.073400 Hz 14:51:06 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0060189 133.920 2 0.0002508 63.360 3 0.0005646 -105.996 4 0.0002040 46.464 14:51:18 Move Stage, position = 0.270000 14:51:20 Stage Position Measurement, pos = 0.2695700 m 14:51:22 Magnet Current, Imag = 14.9783 A Vtrans = 0.149783 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:24 Coil Rotation Frequency Measurement freq = 13.078700 Hz 14:55:47 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0050442 131.964 2 0.0001664 67.974 3 0.0004724 -103.710 4 0.0001967 44.628 14:55:59 Move Stage, position = 0.300000 14:56:01 Stage Position Measurement, pos = 0.2996550 m 14:56:02 Magnet Current, Imag = 14.9790 A Vtrans = 0.149790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:56:05 Coil Rotation Frequency Measurement freq = 13.071100 Hz 15:00:55 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0032932 137.466 2 0.0000829 46.284 3 0.0002387 -115.230 4 0.0001504 42.834 15:01:07 Move Stage, position = 0.330000 15:01:08 Stage Position Measurement, pos = 0.3297450 m 15:01:10 Magnet Current, Imag = 14.9800 A Vtrans = 0.149800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:01:12 Coil Rotation Frequency Measurement freq = 13.075800 Hz 15:06:29 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0013811 152.568 2 0.0000742 -18.894 3 0.0001349 -103.716 4 0.0000944 52.908 15:06:41 Move Stage, position = 0.360000 15:06:43 Stage Position Measurement, pos = 0.3598000 m 15:06:45 Magnet Current, Imag = 14.9793 A Vtrans = 0.149793 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:06:47 Coil Rotation Frequency Measurement freq = 13.072500 Hz 15:11:45 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003495 -147.924 2 0.0001033 -40.494 3 0.0000489 -118.644 4 0.0000496 53.910 15:11:57 Move Stage, position = 0.390000 15:11:59 Stage Position Measurement, pos = 0.3898250 m 15:12:01 Magnet Current, Imag = 14.9788 A Vtrans = 0.149788 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:03 Coil Rotation Frequency Measurement freq = 13.076800 Hz 15:17:10 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003183 11.112 2 0.0001077 -50.544 3 0.0000137 -140.466 4 0.0000340 74.928 15:17:22 Move Stage, position = 0.420000 15:17:23 Stage Position Measurement, pos = 0.4198250 m 15:17:25 Magnet Current, Imag = 14.9777 A Vtrans = 0.149777 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:17:27 Coil Rotation Frequency Measurement freq = 13.080100 Hz 15:22:28 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0008461 52.380 2 0.0000822 -51.582 3 0.0000048 -63.852 4 0.0000248 85.620 15:22:40 Move Stage, position = 0.450000 15:22:41 Stage Position Measurement, pos = 0.4497950 m 15:22:43 Magnet Current, Imag = 14.9791 A Vtrans = 0.149791 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:45 Coil Rotation Frequency Measurement freq = 13.082000 Hz 15:28:18 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0010402 61.086 2 0.0000558 -50.310 3 0.0000000 90.000 4 0.0000215 102.714 15:28:30 Move Stage, position = 0.480000 15:28:32 Stage Position Measurement, pos = 0.4798300 m 15:28:34 Magnet Current, Imag = 14.9795 A Vtrans = 0.149795 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:36 Coil Rotation Frequency Measurement freq = 13.082500 Hz 15:34:27 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0009697 65.838 2 0.0000383 -59.712 3 0.0000066 44.718 4 0.0000000 90.000 15:34:39 Move Stage, position = 0.510000 15:34:40 Stage Position Measurement, pos = 0.5099050 m 15:34:42 Magnet Current, Imag = 14.9781 A Vtrans = 0.149781 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:44 Coil Rotation Frequency Measurement freq = 13.082000 Hz 15:41:21 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0009009 70.992 2 0.0000216 -90.000 3 0.0000054 45.000 4 0.0000216 90.000 15:41:33 Move Stage, position = 0.540000 15:41:34 Stage Position Measurement, pos = 0.5399600 m 15:41:36 Magnet Current, Imag = 14.9762 A Vtrans = 0.149762 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:38 Coil Rotation Frequency Measurement freq = 13.082000 Hz 15:47:45 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0009441 76.170 2 0.0000216 -90.000 3 0.0000104 52.578 4 0.0000162 123.690 15:47:57 Move Stage, position = 0.570000 15:47:59 Stage Position Measurement, pos = 0.5699850 m 15:48:00 Magnet Current, Imag = 14.9763 A Vtrans = 0.149763 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:48:03 Coil Rotation Frequency Measurement freq = 13.081600 Hz 15:53:02 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0009507 79.374 2 0.0000120 -90.384 3 0.0000119 59.826 4 0.0000171 120.072 15:55:01 Move Stage, position = 0.000000 15:55:01 Magnet current ramping to 0.0000 A...