SLAC Magnetic Measurements Date: 05-14-2015 Time: 10:07:18 Project: LCLS Magnet Type: Solenoid Magnet Name: SOL1B Serial Number: Run Number: 24 Measurement Device: G3_Hall Operator: sda Comment: Bx Trim Coil (YCOR) vs Current at z = 0. Currents from -10 to 10 in 1 A steps. On magnetic axis. Solenoid power supply turned off. Test Currents for Solend (A): 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Test Currents for V_Trim (A): -10.00 -9.00 -8.00 -7.00 -6.00 -5.00 -4.00 -3.00 -2.00 -1.00 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 10:07:20 Stage Zeroed 10:07:20 MoveZ Devices: Move Device = MANUAL, Read Device = NONE 10:07:53 Move Stage, position = 0.300000 10:08:16 Hall Probe Zeroed 10:08:36 Hall Probe Type Being Used, type = Group3 10:09:12 Move Stage, position = 0.000000 10:09:16 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000002 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:09:16 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000002 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:09:17 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000002 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:09:18 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000002 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:09:18 Magnet Avgerage Current Measurement for Solend : Imag = 0.0002 +- 0.0000 A 10:09:18 Initial Zero Current Measurement for Solend, Imag_zero = 0.00018925 A 10:09:20 Magnet Current for V_Trim, Imag = 0.0016 A Vtrans = 0.000267 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 10:09:21 Magnet Current for V_Trim, Imag = 0.0016 A Vtrans = 0.000267 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 10:09:21 Magnet Current for V_Trim, Imag = 0.0016 A Vtrans = 0.000266 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 10:09:22 Magnet Current for V_Trim, Imag = 0.0016 A Vtrans = 0.000266 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 10:09:22 Magnet Avgerage Current Measurement for V_Trim : Imag = 0.0016 +- 0.0000 A 10:09:28 Initial Zero Current Measurement for V_Trim, Imag_zero = 0.00159928 A 10:09:30 Hall Probe Range Set, range = 0 10:09:30 Magnet system Solend current ramping to 0.0000 A... 10:09:40 Magnet system V_Trim current ramping to -10.0000 A... 10:10:13 Move Stage, position = 0.000000 10:10:16 Stage Position Measurement, pos = 0.0000000 m 10:10:17 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:10:17 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:10:18 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:10:19 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:10:19 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:10:19 Magnet Current for V_Trim, Imag = -10.0069 A Vtrans = -1.667552 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:10:20 Magnet Current for V_Trim, Imag = -10.0069 A Vtrans = -1.667557 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:10:21 Magnet Current for V_Trim, Imag = -10.0069 A Vtrans = -1.667556 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:10:21 Magnet Current for V_Trim, Imag = -10.0069 A Vtrans = -1.667553 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:10:21 Magnet Avgerage Current Measurement for V_Trim : Imag = -10.0069 +- 0.0000 A 10:10:21 Hall Probe Field Measurement, B = 0.003718 T 10:10:21 Hall Probe Field Measurement, B = 0.003718 T 10:10:22 Hall Probe Field Measurement, B = 0.003718 T 10:10:22 Hall Probe Field Measurement, B = 0.003718 T 10:10:22 Hall Probe Field Measurement: B = 0.003718 +/- 0.000000 T 10:10:22 Move Stage, position = 0.000000 10:10:22 Magnet system Solend current ramping to 0.0000 A... 10:10:32 Magnet system V_Trim current ramping to -9.0000 A... 10:10:40 Move Stage, position = 0.000000 10:10:43 Stage Position Measurement, pos = 0.0000000 m 10:10:43 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000002 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:10:44 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:10:45 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:10:45 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:10:45 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:10:46 Magnet Current for V_Trim, Imag = -9.0074 A Vtrans = -1.500962 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:10:47 Magnet Current for V_Trim, Imag = -9.0074 A Vtrans = -1.500960 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:10:47 Magnet Current for V_Trim, Imag = -9.0074 A Vtrans = -1.500962 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:10:48 Magnet Current for V_Trim, Imag = -9.0074 A Vtrans = -1.500959 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:10:48 Magnet Avgerage Current Measurement for V_Trim : Imag = -9.0074 +- 0.0000 A 10:10:48 Hall Probe Field Measurement, B = 0.003344 T 10:10:48 Hall Probe Field Measurement, B = 0.003344 T 10:10:48 Hall Probe Field Measurement, B = 0.003344 T 10:10:48 Hall Probe Field Measurement, B = 0.003344 T 10:10:48 Hall Probe Field Measurement: B = 0.003344 +/- 0.000000 T 10:10:48 Move Stage, position = 0.000000 10:10:48 Magnet system Solend current ramping to 0.0000 A... 10:10:58 Magnet system V_Trim current ramping to -8.0000 A... 10:11:06 Move Stage, position = 0.000000 10:11:09 Stage Position Measurement, pos = 0.0000000 m 10:11:10 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000002 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:11:11 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000002 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:11:11 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:11:12 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:11:12 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:11:13 Magnet Current for V_Trim, Imag = -8.0043 A Vtrans = -1.333790 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:11:13 Magnet Current for V_Trim, Imag = -8.0044 A Vtrans = -1.333793 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:11:14 Magnet Current for V_Trim, Imag = -8.0043 A Vtrans = -1.333791 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:11:15 Magnet Current for V_Trim, Imag = -8.0044 A Vtrans = -1.333794 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:11:15 Magnet Avgerage Current Measurement for V_Trim : Imag = -8.0044 +- 0.0000 A 10:11:15 Hall Probe Field Measurement, B = 0.002969 T 10:11:15 Hall Probe Field Measurement, B = 0.002969 T 10:11:15 Hall Probe Field Measurement, B = 0.002969 T 10:11:15 Hall Probe Field Measurement, B = 0.002969 T 10:11:15 Hall Probe Field Measurement: B = 0.002969 +/- 0.000000 T 10:11:15 Move Stage, position = 0.000000 10:11:15 Magnet system Solend current ramping to 0.0000 A... 10:11:25 Magnet system V_Trim current ramping to -7.0000 A... 10:11:33 Move Stage, position = 0.000000 10:11:36 Stage Position Measurement, pos = 0.0000000 m 10:11:37 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:11:37 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:11:38 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:11:38 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:11:38 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:11:39 Magnet Current for V_Trim, Imag = -7.0047 A Vtrans = -1.167190 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:11:40 Magnet Current for V_Trim, Imag = -7.0047 A Vtrans = -1.167184 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:11:41 Magnet Current for V_Trim, Imag = -7.0047 A Vtrans = -1.167184 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:11:41 Magnet Current for V_Trim, Imag = -7.0047 A Vtrans = -1.167183 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:11:41 Magnet Avgerage Current Measurement for V_Trim : Imag = -7.0047 +- 0.0000 A 10:11:41 Hall Probe Field Measurement, B = 0.002595 T 10:11:41 Hall Probe Field Measurement, B = 0.002595 T 10:11:41 Hall Probe Field Measurement, B = 0.002595 T 10:11:41 Hall Probe Field Measurement, B = 0.002595 T 10:11:41 Hall Probe Field Measurement: B = 0.002595 +/- 0.000000 T 10:11:41 Move Stage, position = 0.000000 10:11:41 Magnet system Solend current ramping to 0.0000 A... 10:11:52 Magnet system V_Trim current ramping to -6.0000 A... 10:12:00 Move Stage, position = 0.000000 10:12:03 Stage Position Measurement, pos = 0.0000000 m 10:12:03 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:04 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:04 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:05 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:05 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:12:06 Magnet Current for V_Trim, Imag = -6.0054 A Vtrans = -1.000627 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:12:06 Magnet Current for V_Trim, Imag = -6.0054 A Vtrans = -1.000629 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:12:07 Magnet Current for V_Trim, Imag = -6.0054 A Vtrans = -1.000626 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:12:08 Magnet Current for V_Trim, Imag = -6.0053 A Vtrans = -1.000625 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:12:08 Magnet Avgerage Current Measurement for V_Trim : Imag = -6.0054 +- 0.0000 A 10:12:08 Hall Probe Field Measurement, B = 0.002219 T 10:12:08 Hall Probe Field Measurement, B = 0.002219 T 10:12:08 Hall Probe Field Measurement, B = 0.002219 T 10:12:08 Hall Probe Field Measurement, B = 0.002219 T 10:12:08 Hall Probe Field Measurement: B = 0.002219 +/- 0.000000 T 10:12:08 Move Stage, position = 0.000000 10:12:08 Magnet system Solend current ramping to 0.0000 A... 10:12:18 Magnet system V_Trim current ramping to -5.0000 A... 10:12:26 Move Stage, position = 0.000000 10:12:29 Stage Position Measurement, pos = 0.0000000 m 10:12:30 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:30 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:31 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:32 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:32 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:12:32 Magnet Current for V_Trim, Imag = -5.0021 A Vtrans = -0.833423 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:12:33 Magnet Current for V_Trim, Imag = -5.0022 A Vtrans = -0.833426 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:12:34 Magnet Current for V_Trim, Imag = -5.0021 A Vtrans = -0.833425 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:12:34 Magnet Current for V_Trim, Imag = -5.0021 A Vtrans = -0.833424 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:12:34 Magnet Avgerage Current Measurement for V_Trim : Imag = -5.0021 +- 0.0000 A 10:12:34 Hall Probe Field Measurement, B = 0.001844 T 10:12:35 Hall Probe Field Measurement, B = 0.001843 T 10:12:35 Hall Probe Field Measurement, B = 0.001843 T 10:12:35 Hall Probe Field Measurement, B = 0.001843 T 10:12:35 Hall Probe Field Measurement: B = 0.001843 +/- 0.000000 T 10:12:35 Move Stage, position = 0.000000 10:12:35 Magnet system Solend current ramping to 0.0000 A... 10:12:45 Magnet system V_Trim current ramping to -4.0000 A... 10:12:53 Move Stage, position = 0.000000 10:12:56 Stage Position Measurement, pos = 0.0000000 m 10:12:56 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:57 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:58 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:58 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:12:58 Magnet Avgerage Current Measurement for Solend : Imag = 0.0002 +- 0.0000 A 10:12:59 Magnet Current for V_Trim, Imag = -4.0017 A Vtrans = -0.666685 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:00 Magnet Current for V_Trim, Imag = -4.0017 A Vtrans = -0.666687 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:00 Magnet Current for V_Trim, Imag = -4.0017 A Vtrans = -0.666688 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:01 Magnet Current for V_Trim, Imag = -4.0017 A Vtrans = -0.666689 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:01 Magnet Avgerage Current Measurement for V_Trim : Imag = -4.0017 +- 0.0000 A 10:13:01 Hall Probe Field Measurement, B = 0.001470 T 10:13:01 Hall Probe Field Measurement, B = 0.001470 T 10:13:01 Hall Probe Field Measurement, B = 0.001469 T 10:13:01 Hall Probe Field Measurement, B = 0.001469 T 10:13:01 Hall Probe Field Measurement: B = 0.001469 +/- 0.000000 T 10:13:01 Move Stage, position = 0.000000 10:13:01 Magnet system Solend current ramping to 0.0000 A... 10:13:12 Magnet system V_Trim current ramping to -3.0000 A... 10:13:19 Move Stage, position = 0.000000 10:13:22 Stage Position Measurement, pos = 0.0000000 m 10:13:23 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:13:24 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:13:24 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:13:25 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:13:25 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:13:26 Magnet Current for V_Trim, Imag = -3.0025 A Vtrans = -0.500146 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:26 Magnet Current for V_Trim, Imag = -3.0025 A Vtrans = -0.500146 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:27 Magnet Current for V_Trim, Imag = -3.0025 A Vtrans = -0.500147 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:28 Magnet Current for V_Trim, Imag = -3.0025 A Vtrans = -0.500146 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:28 Magnet Avgerage Current Measurement for V_Trim : Imag = -3.0025 +- 0.0000 A 10:13:28 Hall Probe Field Measurement, B = 0.001093 T 10:13:28 Hall Probe Field Measurement, B = 0.001093 T 10:13:28 Hall Probe Field Measurement, B = 0.001093 T 10:13:28 Hall Probe Field Measurement, B = 0.001093 T 10:13:28 Hall Probe Field Measurement: B = 0.001093 +/- 0.000000 T 10:13:28 Move Stage, position = 0.000000 10:13:28 Magnet system Solend current ramping to 0.0000 A... 10:13:38 Magnet system V_Trim current ramping to -2.0000 A... 10:13:46 Move Stage, position = 0.000000 10:13:49 Stage Position Measurement, pos = 0.0000000 m 10:13:50 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:13:50 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:13:51 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:13:51 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:13:51 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:13:52 Magnet Current for V_Trim, Imag = -1.9990 A Vtrans = -0.332904 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:53 Magnet Current for V_Trim, Imag = -1.9990 A Vtrans = -0.332904 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:54 Magnet Current for V_Trim, Imag = -1.9990 A Vtrans = -0.332905 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:54 Magnet Current for V_Trim, Imag = -1.9990 A Vtrans = -0.332902 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:13:54 Magnet Avgerage Current Measurement for V_Trim : Imag = -1.9990 +- 0.0000 A 10:13:54 Hall Probe Field Measurement, B = 0.000717 T 10:13:54 Hall Probe Field Measurement, B = 0.000716 T 10:13:54 Hall Probe Field Measurement, B = 0.000716 T 10:13:54 Hall Probe Field Measurement, B = 0.000716 T 10:13:54 Hall Probe Field Measurement: B = 0.000716 +/- 0.000001 T 10:13:54 Move Stage, position = 0.000000 10:13:54 Magnet system Solend current ramping to 0.0000 A... 10:14:05 Magnet system V_Trim current ramping to -1.0000 A... 10:14:13 Move Stage, position = 0.000000 10:14:16 Stage Position Measurement, pos = 0.0000000 m 10:14:16 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:14:17 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:14:18 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:14:18 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:14:18 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:14:19 Magnet Current for V_Trim, Imag = -0.9991 A Vtrans = -0.166258 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:14:20 Magnet Current for V_Trim, Imag = -0.9992 A Vtrans = -0.166260 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:14:20 Magnet Current for V_Trim, Imag = -0.9992 A Vtrans = -0.166261 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:14:21 Magnet Current for V_Trim, Imag = -0.9992 A Vtrans = -0.166260 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:14:21 Magnet Avgerage Current Measurement for V_Trim : Imag = -0.9992 +- 0.0000 A 10:14:21 Hall Probe Field Measurement, B = 0.000340 T 10:14:21 Hall Probe Field Measurement, B = 0.000341 T 10:14:21 Hall Probe Field Measurement, B = 0.000341 T 10:14:21 Hall Probe Field Measurement, B = 0.000341 T 10:14:21 Hall Probe Field Measurement: B = 0.000341 +/- 0.000000 T 10:14:21 Move Stage, position = 0.000000 10:14:21 Magnet system Solend current ramping to 0.0000 A... 10:14:31 Magnet system V_Trim current ramping to 0.0000 A... 10:14:39 Move Stage, position = 0.000000 10:14:42 Stage Position Measurement, pos = 0.0000000 m 10:14:43 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:14:44 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:14:44 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:14:45 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:14:45 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:14:46 Magnet Current for V_Trim, Imag = -0.0001 A Vtrans = 0.000242 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:14:46 Magnet Current for V_Trim, Imag = -0.0001 A Vtrans = 0.000257 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:14:47 Magnet Current for V_Trim, Imag = -0.0000 A Vtrans = 0.000264 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:14:48 Magnet Current for V_Trim, Imag = -0.0000 A Vtrans = 0.000265 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:14:48 Magnet Avgerage Current Measurement for V_Trim : Imag = -0.0001 +- 0.0001 A 10:14:48 Hall Probe Field Measurement, B = -0.000035 T 10:14:48 Hall Probe Field Measurement, B = -0.000035 T 10:14:48 Hall Probe Field Measurement, B = -0.000035 T 10:14:48 Hall Probe Field Measurement, B = -0.000035 T 10:14:48 Hall Probe Field Measurement: B = -0.000035 +/- 0.000000 T 10:14:48 Move Stage, position = 0.000000 10:14:48 Magnet system Solend current ramping to 0.0000 A... 10:14:58 Magnet system V_Trim current ramping to 1.0000 A... 10:15:06 Move Stage, position = 0.000000 10:15:09 Stage Position Measurement, pos = 0.0000000 m 10:15:10 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:15:10 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:15:11 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:15:11 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:15:11 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:15:12 Magnet Current for V_Trim, Imag = 1.0009 A Vtrans = 0.167081 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:15:13 Magnet Current for V_Trim, Imag = 1.0009 A Vtrans = 0.167077 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:15:14 Magnet Current for V_Trim, Imag = 1.0009 A Vtrans = 0.167077 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:15:14 Magnet Current for V_Trim, Imag = 1.0008 A Vtrans = 0.167074 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:15:14 Magnet Avgerage Current Measurement for V_Trim : Imag = 1.0009 +- 0.0000 A 10:15:14 Hall Probe Field Measurement, B = -0.000413 T 10:15:14 Hall Probe Field Measurement, B = -0.000413 T 10:15:14 Hall Probe Field Measurement, B = -0.000413 T 10:15:14 Hall Probe Field Measurement, B = -0.000413 T 10:15:14 Hall Probe Field Measurement: B = -0.000413 +/- 0.000000 T 10:15:14 Move Stage, position = 0.000000 10:15:14 Magnet system Solend current ramping to 0.0000 A... 10:15:25 Magnet system V_Trim current ramping to 2.0000 A... 10:15:33 Move Stage, position = 0.000000 10:15:36 Stage Position Measurement, pos = 0.0000000 m 10:15:36 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:15:37 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:15:38 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:15:38 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:15:38 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:15:39 Magnet Current for V_Trim, Imag = 2.0004 A Vtrans = 0.333672 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:15:40 Magnet Current for V_Trim, Imag = 2.0005 A Vtrans = 0.333675 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:15:40 Magnet Current for V_Trim, Imag = 2.0004 A Vtrans = 0.333674 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:15:41 Magnet Current for V_Trim, Imag = 2.0005 A Vtrans = 0.333676 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:15:41 Magnet Avgerage Current Measurement for V_Trim : Imag = 2.0004 +- 0.0000 A 10:15:41 Hall Probe Field Measurement, B = -0.000787 T 10:15:41 Hall Probe Field Measurement, B = -0.000787 T 10:15:41 Hall Probe Field Measurement, B = -0.000787 T 10:15:41 Hall Probe Field Measurement, B = -0.000787 T 10:15:41 Hall Probe Field Measurement: B = -0.000787 +/- 0.000000 T 10:15:41 Move Stage, position = 0.000000 10:15:41 Magnet system Solend current ramping to 0.0000 A... 10:15:51 Magnet system V_Trim current ramping to 3.0000 A... 10:15:59 Move Stage, position = 0.000000 10:16:02 Stage Position Measurement, pos = 0.0000000 m 10:16:03 Magnet Current for Solend, Imag = 0.0003 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:04 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:04 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:05 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:05 Magnet Avgerage Current Measurement for Solend : Imag = 0.0002 +- 0.0000 A 10:16:05 Magnet Current for V_Trim, Imag = 3.0028 A Vtrans = 0.500737 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:16:06 Magnet Current for V_Trim, Imag = 3.0028 A Vtrans = 0.500736 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:16:07 Magnet Current for V_Trim, Imag = 3.0028 A Vtrans = 0.500736 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:16:08 Magnet Current for V_Trim, Imag = 3.0028 A Vtrans = 0.500736 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:16:08 Magnet Avgerage Current Measurement for V_Trim : Imag = 3.0028 +- 0.0000 A 10:16:08 Hall Probe Field Measurement, B = -0.001168 T 10:16:08 Hall Probe Field Measurement, B = -0.001168 T 10:16:08 Hall Probe Field Measurement, B = -0.001168 T 10:16:08 Hall Probe Field Measurement, B = -0.001168 T 10:16:08 Hall Probe Field Measurement: B = -0.001168 +/- 0.000000 T 10:16:08 Move Stage, position = 0.000000 10:16:08 Magnet system Solend current ramping to 0.0000 A... 10:16:18 Magnet system V_Trim current ramping to 4.0000 A... 10:16:26 Move Stage, position = 0.000000 10:16:29 Stage Position Measurement, pos = 0.0000000 m 10:16:30 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:30 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:31 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:31 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:31 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:16:32 Magnet Current for V_Trim, Imag = 4.0025 A Vtrans = 0.667352 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:16:33 Magnet Current for V_Trim, Imag = 4.0025 A Vtrans = 0.667354 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:16:33 Magnet Current for V_Trim, Imag = 4.0025 A Vtrans = 0.667353 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:16:34 Magnet Current for V_Trim, Imag = 4.0025 A Vtrans = 0.667354 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:16:34 Magnet Avgerage Current Measurement for V_Trim : Imag = 4.0025 +- 0.0000 A 10:16:34 Hall Probe Field Measurement, B = -0.001543 T 10:16:34 Hall Probe Field Measurement, B = -0.001543 T 10:16:34 Hall Probe Field Measurement, B = -0.001543 T 10:16:34 Hall Probe Field Measurement, B = -0.001543 T 10:16:34 Hall Probe Field Measurement: B = -0.001543 +/- 0.000000 T 10:16:34 Move Stage, position = 0.000000 10:16:34 Magnet system Solend current ramping to 0.0000 A... 10:16:45 Magnet system V_Trim current ramping to 5.0000 A... 10:16:53 Move Stage, position = 0.000000 10:16:56 Stage Position Measurement, pos = 0.0000000 m 10:16:56 Magnet Current for Solend, Imag = 0.0003 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:57 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:57 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:58 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:16:58 Magnet Avgerage Current Measurement for Solend : Imag = 0.0002 +- 0.0000 A 10:16:59 Magnet Current for V_Trim, Imag = 5.0018 A Vtrans = 0.833904 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:16:59 Magnet Current for V_Trim, Imag = 5.0018 A Vtrans = 0.833904 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:17:00 Magnet Current for V_Trim, Imag = 5.0018 A Vtrans = 0.833905 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:17:01 Magnet Current for V_Trim, Imag = 5.0018 A Vtrans = 0.833906 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:17:01 Magnet Avgerage Current Measurement for V_Trim : Imag = 5.0018 +- 0.0000 A 10:17:01 Hall Probe Field Measurement, B = -0.001918 T 10:17:01 Hall Probe Field Measurement, B = -0.001918 T 10:17:01 Hall Probe Field Measurement, B = -0.001918 T 10:17:01 Hall Probe Field Measurement, B = -0.001918 T 10:17:01 Hall Probe Field Measurement: B = -0.001918 +/- 0.000000 T 10:17:01 Move Stage, position = 0.000000 10:17:01 Magnet system Solend current ramping to 0.0000 A... 10:17:11 Magnet system V_Trim current ramping to 6.0000 A... 10:17:19 Move Stage, position = 0.000000 10:17:22 Stage Position Measurement, pos = 0.0000000 m 10:17:23 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:17:23 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:17:24 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:17:25 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:17:25 Magnet Avgerage Current Measurement for Solend : Imag = 0.0002 +- 0.0000 A 10:17:25 Magnet Current for V_Trim, Imag = 6.0044 A Vtrans = 1.000992 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:17:26 Magnet Current for V_Trim, Imag = 6.0043 A Vtrans = 1.000989 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:17:27 Magnet Current for V_Trim, Imag = 6.0043 A Vtrans = 1.000989 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:17:27 Magnet Current for V_Trim, Imag = 6.0043 A Vtrans = 1.000989 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:17:27 Magnet Avgerage Current Measurement for V_Trim : Imag = 6.0043 +- 0.0000 A 10:17:27 Hall Probe Field Measurement, B = -0.002297 T 10:17:27 Hall Probe Field Measurement, B = -0.002297 T 10:17:28 Hall Probe Field Measurement, B = -0.002297 T 10:17:28 Hall Probe Field Measurement, B = -0.002297 T 10:17:28 Hall Probe Field Measurement: B = -0.002297 +/- 0.000000 T 10:17:28 Move Stage, position = 0.000000 10:17:28 Magnet system Solend current ramping to 0.0000 A... 10:17:38 Magnet system V_Trim current ramping to 7.0000 A... 10:17:46 Move Stage, position = 0.000000 10:17:49 Stage Position Measurement, pos = 0.0000000 m 10:17:49 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:17:50 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:17:51 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:17:51 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:17:51 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:17:52 Magnet Current for V_Trim, Imag = 7.0040 A Vtrans = 1.167606 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:17:53 Magnet Current for V_Trim, Imag = 7.0040 A Vtrans = 1.167606 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:17:53 Magnet Current for V_Trim, Imag = 7.0040 A Vtrans = 1.167606 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:17:54 Magnet Current for V_Trim, Imag = 7.0040 A Vtrans = 1.167605 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:17:54 Magnet Avgerage Current Measurement for V_Trim : Imag = 7.0040 +- 0.0000 A 10:17:54 Hall Probe Field Measurement, B = -0.002674 T 10:17:54 Hall Probe Field Measurement, B = -0.002674 T 10:17:54 Hall Probe Field Measurement, B = -0.002674 T 10:17:54 Hall Probe Field Measurement, B = -0.002674 T 10:17:54 Hall Probe Field Measurement: B = -0.002674 +/- 0.000000 T 10:17:54 Move Stage, position = 0.000000 10:17:54 Magnet system Solend current ramping to 0.0000 A... 10:18:04 Magnet system V_Trim current ramping to 8.0000 A... 10:18:12 Move Stage, position = 0.000000 10:18:15 Stage Position Measurement, pos = 0.0000000 m 10:18:16 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:18:17 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:18:17 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:18:18 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:18:18 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:18:18 Magnet Current for V_Trim, Imag = 8.0035 A Vtrans = 1.334190 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:18:19 Magnet Current for V_Trim, Imag = 8.0035 A Vtrans = 1.334190 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:18:20 Magnet Current for V_Trim, Imag = 8.0035 A Vtrans = 1.334191 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:18:21 Magnet Current for V_Trim, Imag = 8.0036 A Vtrans = 1.334196 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:18:21 Magnet Avgerage Current Measurement for V_Trim : Imag = 8.0036 +- 0.0000 A 10:18:21 Hall Probe Field Measurement, B = -0.003050 T 10:18:21 Hall Probe Field Measurement, B = -0.003050 T 10:18:21 Hall Probe Field Measurement, B = -0.003050 T 10:18:21 Hall Probe Field Measurement, B = -0.003050 T 10:18:21 Hall Probe Field Measurement: B = -0.003050 +/- 0.000000 T 10:18:21 Move Stage, position = 0.000000 10:18:21 Magnet system Solend current ramping to 0.0000 A... 10:18:31 Magnet system V_Trim current ramping to 9.0000 A... 10:18:39 Move Stage, position = 0.000000 10:18:42 Stage Position Measurement, pos = 0.0000000 m 10:18:43 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:18:43 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:18:44 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:18:44 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:18:44 Magnet Avgerage Current Measurement for Solend : Imag = 0.0002 +- 0.0000 A 10:18:45 Magnet Current for V_Trim, Imag = 9.0057 A Vtrans = 1.501220 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:18:46 Magnet Current for V_Trim, Imag = 9.0057 A Vtrans = 1.501222 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:18:46 Magnet Current for V_Trim, Imag = 9.0057 A Vtrans = 1.501220 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:18:47 Magnet Current for V_Trim, Imag = 9.0057 A Vtrans = 1.501220 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:18:47 Magnet Avgerage Current Measurement for V_Trim : Imag = 9.0057 +- 0.0000 A 10:18:47 Hall Probe Field Measurement, B = -0.003429 T 10:18:47 Hall Probe Field Measurement, B = -0.003429 T 10:18:47 Hall Probe Field Measurement, B = -0.003429 T 10:18:47 Hall Probe Field Measurement, B = -0.003429 T 10:18:47 Hall Probe Field Measurement: B = -0.003429 +/- 0.000000 T 10:18:47 Move Stage, position = 0.000000 10:18:47 Magnet system Solend current ramping to 0.0000 A... 10:18:58 Magnet system V_Trim current ramping to 10.0000 A... 10:19:06 Move Stage, position = 0.000000 10:19:09 Stage Position Measurement, pos = 0.0000000 m 10:19:09 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:19:10 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:19:10 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:19:11 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000189 A 10:19:11 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 10:19:12 Magnet Current for V_Trim, Imag = 10.0049 A Vtrans = 1.667758 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:19:12 Magnet Current for V_Trim, Imag = 10.0050 A Vtrans = 1.667767 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:19:13 Magnet Current for V_Trim, Imag = 10.0050 A Vtrans = 1.667764 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:19:14 Magnet Current for V_Trim, Imag = 10.0050 A Vtrans = 1.667764 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001599 A 10:19:14 Magnet Avgerage Current Measurement for V_Trim : Imag = 10.0050 +- 0.0000 A 10:19:14 Hall Probe Field Measurement, B = -0.003808 T 10:19:14 Hall Probe Field Measurement, B = -0.003808 T 10:19:14 Hall Probe Field Measurement, B = -0.003808 T 10:19:14 Hall Probe Field Measurement, B = -0.003808 T 10:19:14 Hall Probe Field Measurement: B = -0.003808 +/- 0.000000 T 10:19:14 Move Stage, position = 0.000000 10:19:14 Magnet system Solend current ramping to 0.0000 A... 10:19:15 Magnet system V_Trim current ramping to 0.0000 A...