SLAC Magnetic Measurements Date: 05-07-2015 Time: 11:22:01 Project: LCLS Magnet Type: Solenoid Magnet Name: SOL1B Serial Number: Run Number: 16 Measurement Device: G3_Hall Operator: sda Comment: Bz vs bucking coil current at z cathode location (-196.26 mm from solenoid center). Bucking coil set to -6 to 6 in 0.5 amp steps, Solenoid ps is off. X and Y magnetic center Standardization for Solend: 3 cycles from 5.0 A to 240.0 A to 5.0 A Test Currents for Solend (A): 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Test Currents for BkCoil (A): -6.00 -5.50 -5.00 -4.50 -4.00 -3.50 -3.00 -2.50 -2.00 -1.50 -1.00 -0.50 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 11:22:28 Stage Zeroed 11:22:28 MoveZ Devices: Move Device = MANUAL, Read Device = NONE 11:22:46 Move Stage, position = 0.300000 11:23:13 Hall Probe Zeroed 11:23:18 Hall Probe Type Being Used, type = Group3 11:24:32 Move Stage, position = -0.196260 11:24:37 Magnet Current for Solend, Imag = 0.0009 A Vtrans = 0.000009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:24:37 Magnet Current for Solend, Imag = 0.0010 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:24:38 Magnet Current for Solend, Imag = 0.0010 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:24:39 Magnet Current for Solend, Imag = 0.0010 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:24:39 Magnet Avgerage Current Measurement for Solend : Imag = 0.0010 +- 0.0000 A 11:24:39 Initial Zero Current Measurement for Solend, Imag_zero = 0.000957275 A 11:24:43 Magnet Current for BkCoil, Imag = 0.0016 A Vtrans = 0.000270 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 11:24:44 Magnet Current for BkCoil, Imag = 0.0016 A Vtrans = 0.000269 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 11:24:44 Magnet Current for BkCoil, Imag = 0.0016 A Vtrans = 0.000270 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 11:24:45 Magnet Current for BkCoil, Imag = 0.0016 A Vtrans = 0.000270 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 11:24:45 Magnet Avgerage Current Measurement for BkCoil : Imag = 0.0016 +- 0.0000 A 11:25:01 Initial Zero Current Measurement for BkCoil, Imag_zero = 0.00161858 A 11:25:03 Hall Probe Range Set, range = 0 11:25:03 Magnet system Solend current ramping to 240.0000 A... 11:25:50 Magnet system Solend current ramping to 5.0000 A... 11:26:36 Magnet system Solend current ramping to 240.0000 A... 11:27:22 Magnet system Solend current ramping to 5.0000 A... 11:28:08 Magnet system Solend current ramping to 240.0000 A... 11:28:54 Magnet system Solend current ramping to 5.0000 A... 11:29:40 Magnet system Solend current ramping to 0.0000 A... 11:29:51 Magnet system BkCoil current ramping to -6.0000 A... 11:30:17 Move Stage, position = -0.196260 11:30:20 Stage Position Measurement, pos = -0.1962600 m 11:30:20 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:30:21 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:30:21 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:30:22 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:30:22 Magnet Avgerage Current Measurement for Solend : Imag = 0.0000 +- 0.0000 A 11:30:23 Magnet Current for BkCoil, Imag = -6.0065 A Vtrans = -1.000819 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:30:23 Magnet Current for BkCoil, Imag = -6.0065 A Vtrans = -1.000821 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:30:24 Magnet Current for BkCoil, Imag = -6.0066 A Vtrans = -1.000823 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:30:25 Magnet Current for BkCoil, Imag = -6.0066 A Vtrans = -1.000822 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:30:25 Magnet Avgerage Current Measurement for BkCoil : Imag = -6.0065 +- 0.0000 A 11:30:25 Hall Probe Field Measurement, B = 0.009822 T 11:30:25 Hall Probe Field Measurement, B = 0.009821 T 11:30:25 Hall Probe Field Measurement, B = 0.009821 T 11:30:25 Hall Probe Field Measurement, B = 0.009821 T 11:30:25 Hall Probe Field Measurement: B = 0.009821 +/- 0.000001 T 11:30:25 Move Stage, position = 0.000000 11:30:25 Magnet system Solend current ramping to 0.0000 A... 11:30:35 Magnet system BkCoil current ramping to -5.5000 A... 11:30:42 Move Stage, position = -0.196260 11:30:45 Stage Position Measurement, pos = -0.1962600 m 11:30:45 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:30:46 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:30:47 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:30:47 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:30:47 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:30:48 Magnet Current for BkCoil, Imag = -5.5048 A Vtrans = -0.917196 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:30:49 Magnet Current for BkCoil, Imag = -5.5048 A Vtrans = -0.917197 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:30:49 Magnet Current for BkCoil, Imag = -5.5048 A Vtrans = -0.917198 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:30:50 Magnet Current for BkCoil, Imag = -5.5048 A Vtrans = -0.917198 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:30:50 Magnet Avgerage Current Measurement for BkCoil : Imag = -5.5048 +- 0.0000 A 11:30:50 Hall Probe Field Measurement, B = 0.009017 T 11:30:50 Hall Probe Field Measurement, B = 0.009017 T 11:30:50 Hall Probe Field Measurement, B = 0.009017 T 11:30:50 Hall Probe Field Measurement, B = 0.009017 T 11:30:50 Hall Probe Field Measurement: B = 0.009017 +/- 0.000000 T 11:30:50 Move Stage, position = 0.000000 11:30:50 Magnet system Solend current ramping to 0.0000 A... 11:31:00 Magnet system BkCoil current ramping to -5.0000 A... 11:31:07 Move Stage, position = -0.196260 11:31:10 Stage Position Measurement, pos = -0.1962600 m 11:31:11 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:31:11 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:31:12 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:31:12 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:31:12 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:31:13 Magnet Current for BkCoil, Imag = -5.0049 A Vtrans = -0.833878 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:31:14 Magnet Current for BkCoil, Imag = -5.0049 A Vtrans = -0.833877 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:31:14 Magnet Current for BkCoil, Imag = -5.0049 A Vtrans = -0.833876 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:31:15 Magnet Current for BkCoil, Imag = -5.0049 A Vtrans = -0.833876 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:31:15 Magnet Avgerage Current Measurement for BkCoil : Imag = -5.0049 +- 0.0000 A 11:31:15 Hall Probe Field Measurement, B = 0.008212 T 11:31:15 Hall Probe Field Measurement, B = 0.008212 T 11:31:15 Hall Probe Field Measurement, B = 0.008212 T 11:31:15 Hall Probe Field Measurement, B = 0.008212 T 11:31:15 Hall Probe Field Measurement: B = 0.008212 +/- 0.000000 T 11:31:15 Move Stage, position = 0.000000 11:31:15 Magnet system Solend current ramping to 0.0000 A... 11:31:26 Magnet system BkCoil current ramping to -4.5000 A... 11:31:32 Move Stage, position = -0.196260 11:31:35 Stage Position Measurement, pos = -0.1962600 m 11:31:36 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:31:36 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:31:37 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:31:38 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:31:38 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:31:38 Magnet Current for BkCoil, Imag = -4.5049 A Vtrans = -0.750545 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:31:39 Magnet Current for BkCoil, Imag = -4.5049 A Vtrans = -0.750545 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:31:40 Magnet Current for BkCoil, Imag = -4.5049 A Vtrans = -0.750545 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:31:40 Magnet Current for BkCoil, Imag = -4.5049 A Vtrans = -0.750543 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:31:40 Magnet Avgerage Current Measurement for BkCoil : Imag = -4.5049 +- 0.0000 A 11:31:40 Hall Probe Field Measurement, B = 0.007408 T 11:31:40 Hall Probe Field Measurement, B = 0.007407 T 11:31:40 Hall Probe Field Measurement, B = 0.007407 T 11:31:41 Hall Probe Field Measurement, B = 0.007407 T 11:31:41 Hall Probe Field Measurement: B = 0.007407 +/- 0.000000 T 11:31:41 Move Stage, position = 0.000000 11:31:41 Magnet system Solend current ramping to 0.0000 A... 11:31:51 Magnet system BkCoil current ramping to -4.0000 A... 11:31:57 Move Stage, position = -0.196260 11:32:00 Stage Position Measurement, pos = -0.1962600 m 11:32:01 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:02 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:02 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:03 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:03 Magnet Avgerage Current Measurement for Solend : Imag = 0.0000 +- 0.0000 A 11:32:03 Magnet Current for BkCoil, Imag = -4.0032 A Vtrans = -0.666934 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:04 Magnet Current for BkCoil, Imag = -4.0032 A Vtrans = -0.666934 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:05 Magnet Current for BkCoil, Imag = -4.0032 A Vtrans = -0.666937 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:06 Magnet Current for BkCoil, Imag = -4.0032 A Vtrans = -0.666937 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:06 Magnet Avgerage Current Measurement for BkCoil : Imag = -4.0032 +- 0.0000 A 11:32:06 Hall Probe Field Measurement, B = 0.006599 T 11:32:06 Hall Probe Field Measurement, B = 0.006599 T 11:32:06 Hall Probe Field Measurement, B = 0.006599 T 11:32:06 Hall Probe Field Measurement, B = 0.006599 T 11:32:06 Hall Probe Field Measurement: B = 0.006599 +/- 0.000000 T 11:32:06 Move Stage, position = 0.000000 11:32:06 Magnet system Solend current ramping to 0.0000 A... 11:32:16 Magnet system BkCoil current ramping to -3.5000 A... 11:32:23 Move Stage, position = -0.196260 11:32:26 Stage Position Measurement, pos = -0.1962600 m 11:32:26 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:27 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:28 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:28 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:28 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:32:29 Magnet Current for BkCoil, Imag = -3.5033 A Vtrans = -0.583612 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:30 Magnet Current for BkCoil, Imag = -3.5033 A Vtrans = -0.583613 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:31 Magnet Current for BkCoil, Imag = -3.5033 A Vtrans = -0.583611 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:31 Magnet Current for BkCoil, Imag = -3.5033 A Vtrans = -0.583612 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:31 Magnet Avgerage Current Measurement for BkCoil : Imag = -3.5033 +- 0.0000 A 11:32:31 Hall Probe Field Measurement, B = 0.005792 T 11:32:31 Hall Probe Field Measurement, B = 0.005792 T 11:32:31 Hall Probe Field Measurement, B = 0.005792 T 11:32:32 Hall Probe Field Measurement, B = 0.005793 T 11:32:32 Hall Probe Field Measurement: B = 0.005792 +/- 0.000001 T 11:32:32 Move Stage, position = 0.000000 11:32:32 Magnet system Solend current ramping to 0.0000 A... 11:32:42 Magnet system BkCoil current ramping to -3.0000 A... 11:32:49 Move Stage, position = -0.196260 11:32:52 Stage Position Measurement, pos = -0.1962600 m 11:32:52 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:53 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:53 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:54 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:32:54 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:32:55 Magnet Current for BkCoil, Imag = -3.0034 A Vtrans = -0.500298 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:56 Magnet Current for BkCoil, Imag = -3.0034 A Vtrans = -0.500298 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:56 Magnet Current for BkCoil, Imag = -3.0034 A Vtrans = -0.500298 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:57 Magnet Current for BkCoil, Imag = -3.0034 A Vtrans = -0.500298 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:32:57 Magnet Avgerage Current Measurement for BkCoil : Imag = -3.0034 +- 0.0000 A 11:32:57 Hall Probe Field Measurement, B = 0.004987 T 11:32:57 Hall Probe Field Measurement, B = 0.004987 T 11:32:57 Hall Probe Field Measurement, B = 0.004987 T 11:32:57 Hall Probe Field Measurement, B = 0.004987 T 11:32:57 Hall Probe Field Measurement: B = 0.004987 +/- 0.000000 T 11:32:57 Move Stage, position = 0.000000 11:32:57 Magnet system Solend current ramping to 0.0000 A... 11:33:08 Magnet system BkCoil current ramping to -2.5000 A... 11:33:14 Move Stage, position = -0.196260 11:33:17 Stage Position Measurement, pos = -0.1962600 m 11:33:18 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:33:18 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:33:19 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:33:20 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:33:20 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:33:20 Magnet Current for BkCoil, Imag = -2.5017 A Vtrans = -0.416680 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:33:21 Magnet Current for BkCoil, Imag = -2.5017 A Vtrans = -0.416678 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:33:22 Magnet Current for BkCoil, Imag = -2.5017 A Vtrans = -0.416680 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:33:22 Magnet Current for BkCoil, Imag = -2.5017 A Vtrans = -0.416679 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:33:22 Magnet Avgerage Current Measurement for BkCoil : Imag = -2.5017 +- 0.0000 A 11:33:22 Hall Probe Field Measurement, B = 0.004178 T 11:33:23 Hall Probe Field Measurement, B = 0.004178 T 11:33:23 Hall Probe Field Measurement, B = 0.004178 T 11:33:23 Hall Probe Field Measurement, B = 0.004178 T 11:33:23 Hall Probe Field Measurement: B = 0.004178 +/- 0.000000 T 11:33:23 Move Stage, position = 0.000000 11:33:23 Magnet system Solend current ramping to 0.0000 A... 11:33:33 Magnet system BkCoil current ramping to -2.0000 A... 11:33:39 Move Stage, position = -0.196260 11:33:42 Stage Position Measurement, pos = -0.1962600 m 11:33:43 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:33:44 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:33:44 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:33:45 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:33:45 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:33:46 Magnet Current for BkCoil, Imag = -2.0014 A Vtrans = -0.333301 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:33:46 Magnet Current for BkCoil, Imag = -2.0014 A Vtrans = -0.333300 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:33:47 Magnet Current for BkCoil, Imag = -2.0014 A Vtrans = -0.333301 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:33:48 Magnet Current for BkCoil, Imag = -2.0014 A Vtrans = -0.333302 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:33:48 Magnet Avgerage Current Measurement for BkCoil : Imag = -2.0014 +- 0.0000 A 11:33:48 Hall Probe Field Measurement, B = 0.003373 T 11:33:48 Hall Probe Field Measurement, B = 0.003373 T 11:33:48 Hall Probe Field Measurement, B = 0.003373 T 11:33:48 Hall Probe Field Measurement, B = 0.003371 T 11:33:48 Hall Probe Field Measurement: B = 0.003372 +/- 0.000001 T 11:33:55 Move Stage, position = 0.000000 11:33:55 Magnet system Solend current ramping to 0.0000 A... 11:34:05 Magnet system BkCoil current ramping to -1.5000 A... 11:34:12 Move Stage, position = -0.196260 11:34:15 Stage Position Measurement, pos = -0.1962600 m 11:34:15 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:34:16 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:34:17 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:34:17 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:34:17 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:34:18 Magnet Current for BkCoil, Imag = -1.5017 A Vtrans = -0.250013 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:34:19 Magnet Current for BkCoil, Imag = -1.5017 A Vtrans = -0.250014 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:34:19 Magnet Current for BkCoil, Imag = -1.5017 A Vtrans = -0.250016 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:34:20 Magnet Current for BkCoil, Imag = -1.5017 A Vtrans = -0.250015 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:34:20 Magnet Avgerage Current Measurement for BkCoil : Imag = -1.5017 +- 0.0000 A 11:34:20 Hall Probe Field Measurement, B = 0.002565 T 11:34:20 Hall Probe Field Measurement, B = 0.002565 T 11:34:20 Hall Probe Field Measurement, B = 0.002565 T 11:34:20 Hall Probe Field Measurement, B = 0.002565 T 11:34:20 Hall Probe Field Measurement: B = 0.002565 +/- 0.000000 T 11:34:20 Move Stage, position = 0.000000 11:34:20 Magnet system Solend current ramping to 0.0000 A... 11:34:31 Magnet system BkCoil current ramping to -1.0000 A... 11:34:37 Move Stage, position = -0.196260 11:34:40 Stage Position Measurement, pos = -0.1962600 m 11:34:41 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:34:41 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:34:42 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:34:42 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:34:42 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:34:43 Magnet Current for BkCoil, Imag = -0.9998 A Vtrans = -0.166367 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:34:44 Magnet Current for BkCoil, Imag = -0.9998 A Vtrans = -0.166369 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:34:45 Magnet Current for BkCoil, Imag = -0.9998 A Vtrans = -0.166368 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:34:45 Magnet Current for BkCoil, Imag = -0.9998 A Vtrans = -0.166367 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:34:45 Magnet Avgerage Current Measurement for BkCoil : Imag = -0.9998 +- 0.0000 A 11:34:45 Hall Probe Field Measurement, B = 0.001756 T 11:34:45 Hall Probe Field Measurement, B = 0.001756 T 11:34:45 Hall Probe Field Measurement, B = 0.001756 T 11:34:45 Hall Probe Field Measurement, B = 0.001756 T 11:34:45 Hall Probe Field Measurement: B = 0.001756 +/- 0.000000 T 11:34:45 Move Stage, position = 0.000000 11:34:45 Magnet system Solend current ramping to 0.0000 A... 11:34:56 Magnet system BkCoil current ramping to -0.5000 A... 11:35:02 Move Stage, position = -0.196260 11:35:05 Stage Position Measurement, pos = -0.1962600 m 11:35:06 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:07 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:07 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:08 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:08 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:35:08 Magnet Current for BkCoil, Imag = -0.4998 A Vtrans = -0.083033 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:35:09 Magnet Current for BkCoil, Imag = -0.4998 A Vtrans = -0.083034 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:35:10 Magnet Current for BkCoil, Imag = -0.4998 A Vtrans = -0.083037 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:35:11 Magnet Current for BkCoil, Imag = -0.4998 A Vtrans = -0.083035 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:35:11 Magnet Avgerage Current Measurement for BkCoil : Imag = -0.4998 +- 0.0000 A 11:35:11 Hall Probe Field Measurement, B = 0.000947 T 11:35:11 Hall Probe Field Measurement, B = 0.000947 T 11:35:11 Hall Probe Field Measurement, B = 0.000947 T 11:35:11 Hall Probe Field Measurement, B = 0.000947 T 11:35:11 Hall Probe Field Measurement: B = 0.000947 +/- 0.000000 T 11:35:11 Move Stage, position = 0.000000 11:35:11 Magnet system Solend current ramping to 0.0000 A... 11:35:21 Magnet system BkCoil current ramping to 0.0000 A... 11:35:28 Move Stage, position = -0.196260 11:35:31 Stage Position Measurement, pos = -0.1962600 m 11:35:31 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:32 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:32 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:33 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:33 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:35:34 Magnet Current for BkCoil, Imag = -0.0002 A Vtrans = 0.000231 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:35:34 Magnet Current for BkCoil, Imag = -0.0002 A Vtrans = 0.000231 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:35:35 Magnet Current for BkCoil, Imag = -0.0002 A Vtrans = 0.000233 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:35:36 Magnet Current for BkCoil, Imag = -0.0002 A Vtrans = 0.000229 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:35:36 Magnet Avgerage Current Measurement for BkCoil : Imag = -0.0002 +- 0.0000 A 11:35:36 Hall Probe Field Measurement, B = 0.000141 T 11:35:36 Hall Probe Field Measurement, B = 0.000141 T 11:35:36 Hall Probe Field Measurement, B = 0.000140 T 11:35:36 Hall Probe Field Measurement, B = 0.000140 T 11:35:36 Hall Probe Field Measurement: B = 0.000140 +/- 0.000000 T 11:35:36 Move Stage, position = 0.000000 11:35:36 Magnet system Solend current ramping to 0.0000 A... 11:35:46 Magnet system BkCoil current ramping to 0.5000 A... 11:35:53 Move Stage, position = -0.196260 11:35:56 Stage Position Measurement, pos = -0.1962600 m 11:35:57 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:57 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:58 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:58 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:35:58 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:35:59 Magnet Current for BkCoil, Imag = 0.5003 A Vtrans = 0.083646 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:00 Magnet Current for BkCoil, Imag = 0.5003 A Vtrans = 0.083648 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:00 Magnet Current for BkCoil, Imag = 0.5003 A Vtrans = 0.083647 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:01 Magnet Current for BkCoil, Imag = 0.5003 A Vtrans = 0.083647 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:01 Magnet Avgerage Current Measurement for BkCoil : Imag = 0.5003 +- 0.0000 A 11:36:01 Hall Probe Field Measurement, B = -0.000670 T 11:36:01 Hall Probe Field Measurement, B = -0.000670 T 11:36:01 Hall Probe Field Measurement, B = -0.000670 T 11:36:01 Hall Probe Field Measurement, B = -0.000670 T 11:36:01 Hall Probe Field Measurement: B = -0.000670 +/- 0.000000 T 11:36:01 Move Stage, position = 0.000000 11:36:01 Magnet system Solend current ramping to 0.0000 A... 11:36:12 Magnet system BkCoil current ramping to 1.0000 A... 11:36:18 Move Stage, position = -0.196260 11:36:21 Stage Position Measurement, pos = -0.1962600 m 11:36:22 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:36:22 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:36:23 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:36:24 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:36:24 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:36:24 Magnet Current for BkCoil, Imag = 1.0001 A Vtrans = 0.166947 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:25 Magnet Current for BkCoil, Imag = 1.0001 A Vtrans = 0.166949 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:26 Magnet Current for BkCoil, Imag = 1.0001 A Vtrans = 0.166948 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:26 Magnet Current for BkCoil, Imag = 1.0001 A Vtrans = 0.166947 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:26 Magnet Avgerage Current Measurement for BkCoil : Imag = 1.0001 +- 0.0000 A 11:36:27 Hall Probe Field Measurement, B = -0.001479 T 11:36:27 Hall Probe Field Measurement, B = -0.001479 T 11:36:27 Hall Probe Field Measurement, B = -0.001479 T 11:36:27 Hall Probe Field Measurement, B = -0.001479 T 11:36:27 Hall Probe Field Measurement: B = -0.001479 +/- 0.000000 T 11:36:27 Move Stage, position = 0.000000 11:36:27 Magnet system Solend current ramping to 0.0000 A... 11:36:37 Magnet system BkCoil current ramping to 1.5000 A... 11:36:43 Move Stage, position = -0.196260 11:36:46 Stage Position Measurement, pos = -0.1962600 m 11:36:47 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:36:48 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:36:48 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:36:49 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:36:49 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:36:50 Magnet Current for BkCoil, Imag = 1.5012 A Vtrans = 0.250476 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:50 Magnet Current for BkCoil, Imag = 1.5012 A Vtrans = 0.250477 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:51 Magnet Current for BkCoil, Imag = 1.5012 A Vtrans = 0.250477 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:52 Magnet Current for BkCoil, Imag = 1.5012 A Vtrans = 0.250476 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:36:52 Magnet Avgerage Current Measurement for BkCoil : Imag = 1.5012 +- 0.0000 A 11:36:52 Hall Probe Field Measurement, B = -0.002288 T 11:36:52 Hall Probe Field Measurement, B = -0.002288 T 11:36:52 Hall Probe Field Measurement, B = -0.002288 T 11:36:52 Hall Probe Field Measurement, B = -0.002288 T 11:36:52 Hall Probe Field Measurement: B = -0.002288 +/- 0.000000 T 11:36:52 Move Stage, position = 0.000000 11:36:52 Magnet system Solend current ramping to 0.0000 A... 11:37:02 Magnet system BkCoil current ramping to 2.0000 A... 11:37:09 Move Stage, position = -0.196260 11:37:12 Stage Position Measurement, pos = -0.1962600 m 11:37:12 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:37:13 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:37:13 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:37:14 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:37:14 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:37:15 Magnet Current for BkCoil, Imag = 2.0011 A Vtrans = 0.333786 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:37:15 Magnet Current for BkCoil, Imag = 2.0011 A Vtrans = 0.333787 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:37:16 Magnet Current for BkCoil, Imag = 2.0011 A Vtrans = 0.333785 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:37:17 Magnet Current for BkCoil, Imag = 2.0011 A Vtrans = 0.333788 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:37:17 Magnet Avgerage Current Measurement for BkCoil : Imag = 2.0011 +- 0.0000 A 11:37:17 Hall Probe Field Measurement, B = -0.003096 T 11:37:17 Hall Probe Field Measurement, B = -0.003096 T 11:37:17 Hall Probe Field Measurement, B = -0.003096 T 11:37:17 Hall Probe Field Measurement, B = -0.003096 T 11:37:17 Hall Probe Field Measurement: B = -0.003096 +/- 0.000000 T 11:37:17 Move Stage, position = 0.000000 11:37:17 Magnet system Solend current ramping to 0.0000 A... 11:37:27 Magnet system BkCoil current ramping to 2.5000 A... 11:37:34 Move Stage, position = -0.196260 11:37:37 Stage Position Measurement, pos = -0.1962600 m 11:37:37 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:37:38 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:37:39 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:37:39 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:37:39 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:37:40 Magnet Current for BkCoil, Imag = 2.5008 A Vtrans = 0.417064 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:37:41 Magnet Current for BkCoil, Imag = 2.5008 A Vtrans = 0.417065 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:37:41 Magnet Current for BkCoil, Imag = 2.5008 A Vtrans = 0.417068 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:37:42 Magnet Current for BkCoil, Imag = 2.5008 A Vtrans = 0.417068 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:37:42 Magnet Avgerage Current Measurement for BkCoil : Imag = 2.5008 +- 0.0000 A 11:37:42 Hall Probe Field Measurement, B = -0.003905 T 11:37:42 Hall Probe Field Measurement, B = -0.003905 T 11:37:42 Hall Probe Field Measurement, B = -0.003905 T 11:37:42 Hall Probe Field Measurement, B = -0.003905 T 11:37:42 Hall Probe Field Measurement: B = -0.003905 +/- 0.000000 T 11:37:42 Move Stage, position = 0.000000 11:37:42 Magnet system Solend current ramping to 0.0000 A... 11:37:53 Magnet system BkCoil current ramping to 3.0000 A... 11:37:59 Move Stage, position = -0.196260 11:38:02 Stage Position Measurement, pos = -0.1962600 m 11:38:03 Magnet Current for Solend, Imag = 0.0002 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:03 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:04 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:05 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:05 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:38:05 Magnet Current for BkCoil, Imag = 3.0021 A Vtrans = 0.500616 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:06 Magnet Current for BkCoil, Imag = 3.0021 A Vtrans = 0.500615 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:07 Magnet Current for BkCoil, Imag = 3.0021 A Vtrans = 0.500617 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:07 Magnet Current for BkCoil, Imag = 3.0021 A Vtrans = 0.500617 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:07 Magnet Avgerage Current Measurement for BkCoil : Imag = 3.0021 +- 0.0000 A 11:38:07 Hall Probe Field Measurement, B = -0.004714 T 11:38:08 Hall Probe Field Measurement, B = -0.004714 T 11:38:08 Hall Probe Field Measurement, B = -0.004714 T 11:38:08 Hall Probe Field Measurement, B = -0.004714 T 11:38:08 Hall Probe Field Measurement: B = -0.004714 +/- 0.000000 T 11:38:08 Move Stage, position = 0.000000 11:38:08 Magnet system Solend current ramping to 0.0000 A... 11:38:18 Magnet system BkCoil current ramping to 3.5000 A... 11:38:24 Move Stage, position = -0.196260 11:38:27 Stage Position Measurement, pos = -0.1962600 m 11:38:28 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:29 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:29 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:30 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:30 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:38:31 Magnet Current for BkCoil, Imag = 3.5020 A Vtrans = 0.583932 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:31 Magnet Current for BkCoil, Imag = 3.5020 A Vtrans = 0.583933 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:32 Magnet Current for BkCoil, Imag = 3.5020 A Vtrans = 0.583929 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:33 Magnet Current for BkCoil, Imag = 3.5020 A Vtrans = 0.583931 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:33 Magnet Avgerage Current Measurement for BkCoil : Imag = 3.5020 +- 0.0000 A 11:38:33 Hall Probe Field Measurement, B = -0.005525 T 11:38:33 Hall Probe Field Measurement, B = -0.005525 T 11:38:33 Hall Probe Field Measurement, B = -0.005525 T 11:38:33 Hall Probe Field Measurement, B = -0.005525 T 11:38:33 Hall Probe Field Measurement: B = -0.005525 +/- 0.000000 T 11:38:33 Move Stage, position = 0.000000 11:38:33 Magnet system Solend current ramping to 0.0000 A... 11:38:43 Magnet system BkCoil current ramping to 4.0000 A... 11:38:50 Move Stage, position = -0.196260 11:38:53 Stage Position Measurement, pos = -0.1962600 m 11:38:53 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:54 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:54 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:55 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:38:55 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:38:56 Magnet Current for BkCoil, Imag = 4.0018 A Vtrans = 0.667236 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:56 Magnet Current for BkCoil, Imag = 4.0018 A Vtrans = 0.667241 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:57 Magnet Current for BkCoil, Imag = 4.0018 A Vtrans = 0.667244 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:58 Magnet Current for BkCoil, Imag = 4.0018 A Vtrans = 0.667244 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:38:58 Magnet Avgerage Current Measurement for BkCoil : Imag = 4.0018 +- 0.0000 A 11:38:58 Hall Probe Field Measurement, B = -0.006334 T 11:38:58 Hall Probe Field Measurement, B = -0.006334 T 11:38:58 Hall Probe Field Measurement, B = -0.006334 T 11:38:58 Hall Probe Field Measurement, B = -0.006334 T 11:38:58 Hall Probe Field Measurement: B = -0.006334 +/- 0.000000 T 11:38:58 Move Stage, position = 0.000000 11:38:58 Magnet system Solend current ramping to 0.0000 A... 11:39:08 Magnet system BkCoil current ramping to 4.5000 A... 11:39:15 Move Stage, position = -0.196260 11:39:18 Stage Position Measurement, pos = -0.1962600 m 11:39:18 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:39:19 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:39:20 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:39:20 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:39:20 Magnet Avgerage Current Measurement for Solend : Imag = 0.0000 +- 0.0000 A 11:39:21 Magnet Current for BkCoil, Imag = 4.5030 A Vtrans = 0.750773 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:39:22 Magnet Current for BkCoil, Imag = 4.5030 A Vtrans = 0.750773 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:39:22 Magnet Current for BkCoil, Imag = 4.5030 A Vtrans = 0.750774 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:39:23 Magnet Current for BkCoil, Imag = 4.5030 A Vtrans = 0.750775 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:39:23 Magnet Avgerage Current Measurement for BkCoil : Imag = 4.5030 +- 0.0000 A 11:39:23 Hall Probe Field Measurement, B = -0.007143 T 11:39:23 Hall Probe Field Measurement, B = -0.007143 T 11:39:23 Hall Probe Field Measurement, B = -0.007143 T 11:39:23 Hall Probe Field Measurement, B = -0.007143 T 11:39:23 Hall Probe Field Measurement: B = -0.007143 +/- 0.000000 T 11:39:23 Move Stage, position = 0.000000 11:39:23 Magnet system Solend current ramping to 0.0000 A... 11:39:33 Magnet system BkCoil current ramping to 5.0000 A... 11:39:40 Move Stage, position = -0.196260 11:39:43 Stage Position Measurement, pos = -0.1962600 m 11:39:44 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:39:44 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:39:45 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:39:45 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:39:45 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:39:46 Magnet Current for BkCoil, Imag = 5.0027 A Vtrans = 0.834055 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:39:47 Magnet Current for BkCoil, Imag = 5.0027 A Vtrans = 0.834055 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:39:47 Magnet Current for BkCoil, Imag = 5.0027 A Vtrans = 0.834055 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:39:48 Magnet Current for BkCoil, Imag = 5.0027 A Vtrans = 0.834055 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:39:48 Magnet Avgerage Current Measurement for BkCoil : Imag = 5.0027 +- 0.0000 A 11:39:48 Hall Probe Field Measurement, B = -0.007953 T 11:39:48 Hall Probe Field Measurement, B = -0.007953 T 11:39:48 Hall Probe Field Measurement, B = -0.007953 T 11:39:48 Hall Probe Field Measurement, B = -0.007953 T 11:39:48 Hall Probe Field Measurement: B = -0.007953 +/- 0.000000 T 11:39:48 Move Stage, position = 0.000000 11:39:48 Magnet system Solend current ramping to 0.0000 A... 11:39:59 Magnet system BkCoil current ramping to 5.5000 A... 11:40:05 Move Stage, position = -0.196260 11:40:08 Stage Position Measurement, pos = -0.1962600 m 11:40:09 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:40:09 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:40:10 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:40:11 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:40:11 Magnet Avgerage Current Measurement for Solend : Imag = 0.0001 +- 0.0000 A 11:40:11 Magnet Current for BkCoil, Imag = 5.5026 A Vtrans = 0.917365 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:40:12 Magnet Current for BkCoil, Imag = 5.5026 A Vtrans = 0.917366 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:40:13 Magnet Current for BkCoil, Imag = 5.5026 A Vtrans = 0.917367 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:40:13 Magnet Current for BkCoil, Imag = 5.5026 A Vtrans = 0.917367 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:40:13 Magnet Avgerage Current Measurement for BkCoil : Imag = 5.5026 +- 0.0000 A 11:40:13 Hall Probe Field Measurement, B = -0.008761 T 11:40:13 Hall Probe Field Measurement, B = -0.008761 T 11:40:14 Hall Probe Field Measurement, B = -0.008761 T 11:40:14 Hall Probe Field Measurement, B = -0.008761 T 11:40:14 Hall Probe Field Measurement: B = -0.008761 +/- 0.000000 T 11:40:14 Move Stage, position = 0.000000 11:40:14 Magnet system Solend current ramping to 0.0000 A... 11:40:24 Magnet system BkCoil current ramping to 6.0000 A... 11:40:30 Move Stage, position = -0.196260 11:40:33 Stage Position Measurement, pos = -0.1962600 m 11:40:34 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:40:35 Magnet Current for Solend, Imag = 0.0001 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:40:35 Magnet Current for Solend, Imag = 0.0000 A Vtrans = 0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:40:36 Magnet Current for Solend, Imag = -0.0000 A Vtrans = 0.000009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000957 A 11:40:36 Magnet Avgerage Current Measurement for Solend : Imag = 0.0000 +- 0.0000 A 11:40:36 Magnet Current for BkCoil, Imag = 6.0036 A Vtrans = 1.000876 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:40:37 Magnet Current for BkCoil, Imag = 6.0036 A Vtrans = 1.000876 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:40:38 Magnet Current for BkCoil, Imag = 6.0036 A Vtrans = 1.000877 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:40:39 Magnet Current for BkCoil, Imag = 6.0036 A Vtrans = 1.000876 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001619 A 11:40:39 Magnet Avgerage Current Measurement for BkCoil : Imag = 6.0036 +- 0.0000 A 11:40:39 Hall Probe Field Measurement, B = -0.009572 T 11:40:39 Hall Probe Field Measurement, B = -0.009572 T 11:40:39 Hall Probe Field Measurement, B = -0.009572 T 11:40:39 Hall Probe Field Measurement, B = -0.009572 T 11:40:39 Hall Probe Field Measurement: B = -0.009572 +/- 0.000000 T 11:40:39 Move Stage, position = 0.000000 11:40:39 Magnet system Solend current ramping to 0.0000 A... 11:40:39 Magnet system BkCoil current ramping to 0.0000 A...