SLAC Magnetic Measurements Date: 07-25-2006 Time: 16:53:49 Project: LCLS Magnet Type: solenoid Magnet Name: SOL1 Serial Number: 2 Run Number: 57 Measurement Device: Coil ZZ Operator: sda Comment: Short Coil Harms n =3 vs z -.2 m to .2. Magnet aligned to magnetic axis. old lockin amp Standardization: 1 cycles from 5.1 A to 270.0 A to 5.1 A Test Currents (A): 172.5 16:54:06 Vcoil, device being used, type = SR850 16:54:17 Stage Zeroed 16:54:17 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 16:54:19 Initial Zero Current Measurement, Imag_zero = 0.0000 A 16:54:19 Magnet current ramping to 5.0000 A... 16:54:52 Magnet current ramping to 270.0000 A... 16:56:19 Magnet current ramping to 5.1000 A... 16:57:45 Magnet current ramping to 172.4760 A... 16:58:46 Magnet Current, Imag = 172.6800 A Vtrans = 1.726800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:58:47 Magnet Current, Imag = 172.6867 A Vtrans = 1.726867 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:58:49 Magnet Current, Imag = 172.6878 A Vtrans = 1.726878 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:58:50 Magnet Current, Imag = 172.6909 A Vtrans = 1.726909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:58:50 Magnet Current Measurement: Imag = 172.6864 +- 0.0040 A 16:59:35 Move Stage, position = -0.200000 16:59:37 Stage Position Measurement, pos = -0.1995850 m 16:59:38 Magnet Current, Imag = 172.6759 A Vtrans = 1.726759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:59:41 Coil Rotation Frequency Measurement freq = 23.804700 Hz 17:02:31 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000330 53.130 2 0.0000150 24.786 17:02:40 Move Stage, position = -0.187500 17:02:42 Stage Position Measurement, pos = -0.1877550 m 17:02:43 Magnet Current, Imag = 172.6857 A Vtrans = 1.726857 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:02:45 Coil Rotation Frequency Measurement freq = 23.796100 Hz 17:05:18 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000400 53.682 2 0.0000189 -43.020 17:05:27 Move Stage, position = -0.175000 17:05:29 Stage Position Measurement, pos = -0.1752550 m 17:05:30 Magnet Current, Imag = 172.6850 A Vtrans = 1.726850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:05:32 Coil Rotation Frequency Measurement freq = 23.792300 Hz 17:08:02 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000534 62.580 2 0.0000241 15.384 17:08:10 Move Stage, position = -0.162500 17:08:12 Stage Position Measurement, pos = -0.1627600 m 17:08:13 Magnet Current, Imag = 172.6848 A Vtrans = 1.726848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:08:16 Coil Rotation Frequency Measurement freq = 23.800800 Hz 17:10:45 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000696 52.134 2 0.0000482 5.730 17:10:54 Move Stage, position = -0.150000 17:10:56 Stage Position Measurement, pos = -0.1502500 m 17:10:57 Magnet Current, Imag = 172.6841 A Vtrans = 1.726841 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:10:59 Coil Rotation Frequency Measurement freq = 23.791300 Hz 17:13:18 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0001161 46.512 2 0.0000721 6.318 17:13:26 Move Stage, position = -0.137500 17:13:28 Stage Position Measurement, pos = -0.1376900 m 17:13:29 Magnet Current, Imag = 172.6854 A Vtrans = 1.726854 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:13:31 Coil Rotation Frequency Measurement freq = 23.796100 Hz 17:15:47 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002142 48.846 2 0.0001026 7.116 17:15:55 Move Stage, position = -0.125000 17:15:57 Stage Position Measurement, pos = -0.1252100 m 17:15:58 Magnet Current, Imag = 172.6891 A Vtrans = 1.726891 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:16:00 Coil Rotation Frequency Measurement freq = 23.790400 Hz 17:18:12 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003797 52.770 2 0.0002020 5.106 17:18:21 Move Stage, position = -0.112500 17:18:23 Stage Position Measurement, pos = -0.1127050 m 17:18:24 Magnet Current, Imag = 172.6988 A Vtrans = 1.726988 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:18:26 Coil Rotation Frequency Measurement freq = 23.795100 Hz 17:20:31 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0006254 55.344 2 0.0003178 3.240 17:20:39 Move Stage, position = -0.100000 17:20:41 Stage Position Measurement, pos = -0.1001600 m 17:20:42 Magnet Current, Imag = 172.6922 A Vtrans = 1.726922 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:20:44 Coil Rotation Frequency Measurement freq = 23.792300 Hz 17:22:49 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0007695 59.424 2 0.0003923 0.444 17:22:58 Move Stage, position = -0.087500 17:22:59 Stage Position Measurement, pos = -0.0876350 m 17:23:01 Magnet Current, Imag = 172.6810 A Vtrans = 1.726810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:23:03 Coil Rotation Frequency Measurement freq = 23.798000 Hz 17:25:07 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0006785 68.106 2 0.0003685 -2.790 17:25:16 Move Stage, position = -0.075000 17:25:17 Stage Position Measurement, pos = -0.0751200 m 17:25:19 Magnet Current, Imag = 172.6836 A Vtrans = 1.726836 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:25:21 Coil Rotation Frequency Measurement freq = 23.780800 Hz 17:27:29 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0004597 83.550 2 0.0003032 -1.836 17:27:38 Move Stage, position = -0.062500 17:27:39 Stage Position Measurement, pos = -0.0625750 m 17:27:41 Magnet Current, Imag = 172.6802 A Vtrans = 1.726802 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:27:43 Coil Rotation Frequency Measurement freq = 23.793200 Hz 17:29:51 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003235 107.928 2 0.0002370 -5.514 17:30:00 Move Stage, position = -0.050000 17:30:01 Stage Position Measurement, pos = -0.0500450 m 17:30:03 Magnet Current, Imag = 172.6877 A Vtrans = 1.726877 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:30:05 Coil Rotation Frequency Measurement freq = 23.792300 Hz 17:32:15 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002878 137.784 2 0.0001886 -12.894 17:32:24 Move Stage, position = -0.037500 17:32:25 Stage Position Measurement, pos = -0.0375750 m 17:32:27 Magnet Current, Imag = 172.6806 A Vtrans = 1.726806 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:32:29 Coil Rotation Frequency Measurement freq = 23.792300 Hz 17:34:41 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003378 154.962 2 0.0001612 -15.150 17:34:50 Move Stage, position = -0.025000 17:34:51 Stage Position Measurement, pos = -0.0249600 m 17:34:53 Magnet Current, Imag = 172.6786 A Vtrans = 1.726786 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:34:55 Coil Rotation Frequency Measurement freq = 23.797000 Hz 17:37:06 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003675 162.150 2 0.0001378 -6.552 17:37:15 Move Stage, position = -0.012500 17:37:17 Stage Position Measurement, pos = -0.0124650 m 17:37:18 Magnet Current, Imag = 172.6811 A Vtrans = 1.726811 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:37:20 Coil Rotation Frequency Measurement freq = 23.792300 Hz 17:39:32 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003739 163.932 2 0.0001273 4.338 17:39:41 Move Stage, position = 0.000000 17:39:42 Stage Position Measurement, pos = -0.0000300 m 17:39:44 Magnet Current, Imag = 172.6811 A Vtrans = 1.726811 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:39:46 Coil Rotation Frequency Measurement freq = 23.796100 Hz 17:41:57 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003458 164.808 2 0.0001242 4.650 17:42:06 Move Stage, position = 0.012500 17:42:08 Stage Position Measurement, pos = 0.0124500 m 17:42:09 Magnet Current, Imag = 172.7003 A Vtrans = 1.727003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:42:11 Coil Rotation Frequency Measurement freq = 23.798900 Hz 17:44:22 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003258 164.136 2 0.0001084 -7.392 17:44:31 Move Stage, position = 0.025000 17:44:33 Stage Position Measurement, pos = 0.0250050 m 17:44:34 Magnet Current, Imag = 172.6828 A Vtrans = 1.726828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:44:36 Coil Rotation Frequency Measurement freq = 23.806600 Hz 17:46:52 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003255 170.928 2 0.0001002 1.842 17:47:01 Move Stage, position = 0.037500 17:47:02 Stage Position Measurement, pos = 0.0374950 m 17:47:04 Magnet Current, Imag = 172.6854 A Vtrans = 1.726854 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:47:06 Coil Rotation Frequency Measurement freq = 23.801800 Hz 17:49:23 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003624 178.566 2 0.0000704 -0.768 17:49:32 Move Stage, position = 0.050000 17:49:33 Stage Position Measurement, pos = 0.0500000 m 17:49:35 Magnet Current, Imag = 172.6874 A Vtrans = 1.726874 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:49:37 Coil Rotation Frequency Measurement freq = 23.797000 Hz 17:51:56 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0004147 -171.630 2 0.0000215 27.420 17:52:04 Move Stage, position = 0.062500 17:52:06 Stage Position Measurement, pos = 0.0625400 m 17:52:07 Magnet Current, Imag = 172.6785 A Vtrans = 1.726785 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:52:10 Coil Rotation Frequency Measurement freq = 23.798900 Hz 17:54:25 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0005044 -158.478 2 0.0000647 179.184 17:54:33 Move Stage, position = 0.075000 17:54:35 Stage Position Measurement, pos = 0.0750700 m 17:54:36 Magnet Current, Imag = 172.6814 A Vtrans = 1.726814 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:54:39 Coil Rotation Frequency Measurement freq = 23.797000 Hz 17:56:46 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0006626 -148.572 2 0.0001907 -180.000 17:56:54 Move Stage, position = 0.087500 17:56:56 Stage Position Measurement, pos = 0.0875850 m 17:56:57 Magnet Current, Imag = 172.6811 A Vtrans = 1.726811 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:56:59 Coil Rotation Frequency Measurement freq = 23.799900 Hz 17:59:04 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0008416 -141.402 2 0.0003229 -179.472 17:59:13 Move Stage, position = 0.100000 17:59:14 Stage Position Measurement, pos = 0.1001150 m 17:59:16 Magnet Current, Imag = 172.6831 A Vtrans = 1.726831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:59:18 Coil Rotation Frequency Measurement freq = 23.797000 Hz 18:01:23 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0008580 -139.266 2 0.0003802 -180.000 18:01:31 Move Stage, position = 0.112500 18:01:33 Stage Position Measurement, pos = 0.1126750 m 18:01:34 Magnet Current, Imag = 172.6773 A Vtrans = 1.726773 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:01:36 Coil Rotation Frequency Measurement freq = 23.786500 Hz 18:03:40 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0006487 -140.262 2 0.0002885 179.760 18:03:49 Move Stage, position = 0.125000 18:03:50 Stage Position Measurement, pos = 0.1251600 m 18:03:52 Magnet Current, Imag = 172.6793 A Vtrans = 1.726793 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:03:54 Coil Rotation Frequency Measurement freq = 23.800800 Hz 18:06:06 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003888 -143.220 2 0.0001630 176.610 18:06:15 Move Stage, position = 0.137500 18:06:16 Stage Position Measurement, pos = 0.1376500 m 18:06:18 Magnet Current, Imag = 172.6882 A Vtrans = 1.726882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:06:20 Coil Rotation Frequency Measurement freq = 23.798900 Hz 18:08:39 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0001986 -148.548 2 0.0000889 175.842 18:08:48 Move Stage, position = 0.150000 18:08:49 Stage Position Measurement, pos = 0.1501750 m 18:08:51 Magnet Current, Imag = 172.6845 A Vtrans = 1.726845 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:08:53 Coil Rotation Frequency Measurement freq = 23.775100 Hz 18:11:19 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0001018 -152.592 2 0.0000373 174.018 18:11:28 Move Stage, position = 0.162500 18:11:30 Stage Position Measurement, pos = 0.1626650 m 18:11:31 Magnet Current, Imag = 172.6835 A Vtrans = 1.726835 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:11:33 Coil Rotation Frequency Measurement freq = 23.792300 Hz 18:14:24 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000587 -161.292 2 0.0000121 -135.000 18:14:32 Move Stage, position = 0.175000 18:14:34 Stage Position Measurement, pos = 0.1751050 m 18:14:35 Magnet Current, Imag = 172.6824 A Vtrans = 1.726824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:14:38 Coil Rotation Frequency Measurement freq = 23.794200 Hz 18:17:32 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000344 170.640 2 0.0000043 -90.000 18:17:41 Move Stage, position = 0.187500 18:17:42 Stage Position Measurement, pos = 0.1876300 m 18:17:44 Magnet Current, Imag = 172.6833 A Vtrans = 1.726833 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:17:46 Coil Rotation Frequency Measurement freq = 23.787500 Hz 18:20:40 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000304 137.886 2 0.0000043 -15.708 18:20:49 Move Stage, position = 0.200000 18:20:51 Stage Position Measurement, pos = 0.2001550 m 18:20:52 Magnet Current, Imag = 172.6831 A Vtrans = 1.726831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:20:54 Coil Rotation Frequency Measurement freq = 23.779900 Hz 18:23:24 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000334 121.164 2 0.0000102 16.734 18:24:09 Move Stage, position = 0.000000 18:24:10 Magnet current ramping to 0.0000 A...