SLAC Magnetic Measurements Date: 07-25-2006 Time: 11:00:25 Project: LCLS Magnet Type: solenoid Magnet Name: SOL1 Serial Number: 2 Run Number: 56 Measurement Device: Coil ZZ Operator: sda Comment: Short Coil Harms n =3 vs z -.2 m to .2. Magnet aligned to magnetic axis Standardization: 1 cycles from 5.1 A to 270.0 A to 5.1 A Test Currents (A): 172.5 11:00:43 Vcoil, device being used, type = SR850 11:01:05 Stage Zeroed 11:01:05 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 11:01:07 Initial Zero Current Measurement, Imag_zero = 0.0000 A 11:01:07 Magnet current ramping to 5.0000 A... 11:01:40 Magnet current ramping to 270.0000 A... 11:03:06 Magnet current ramping to 5.1000 A... 11:04:33 Magnet current ramping to 172.4760 A... 11:05:34 Magnet Current, Imag = 172.6857 A Vtrans = 1.726857 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:35 Magnet Current, Imag = 172.6828 A Vtrans = 1.726828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:36 Magnet Current, Imag = 172.6918 A Vtrans = 1.726918 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:38 Magnet Current, Imag = 172.6871 A Vtrans = 1.726871 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:38 Magnet Current Measurement: Imag = 172.6868 +- 0.0033 A 11:06:23 Move Stage, position = -0.200000 11:06:25 Stage Position Measurement, pos = -0.2002550 m 11:06:26 Magnet Current, Imag = 172.6886 A Vtrans = 1.726886 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:28 Coil Rotation Frequency Measurement freq = 23.794200 Hz 11:11:01 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000247 79.686 2 0.0000158 -17.478 3 0.0000099 60.270 11:11:10 Move Stage, position = -0.187500 11:11:11 Stage Position Measurement, pos = -0.1883850 m 11:11:13 Magnet Current, Imag = 172.6800 A Vtrans = 1.726800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:15 Coil Rotation Frequency Measurement freq = 23.788500 Hz 11:15:10 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000341 45.000 2 0.0001098 -69.726 3 0.0000523 -90.000 11:15:19 Move Stage, position = -0.175000 11:15:21 Stage Position Measurement, pos = -0.1758850 m 11:15:22 Magnet Current, Imag = 172.6980 A Vtrans = 1.726980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:24 Coil Rotation Frequency Measurement freq = 23.784600 Hz 11:19:11 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003271 48.390 2 0.0002092 -64.050 3 0.0000607 -72.414 11:19:20 Move Stage, position = -0.162500 11:19:21 Stage Position Measurement, pos = -0.1633850 m 11:19:23 Magnet Current, Imag = 172.6864 A Vtrans = 1.726864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:25 Coil Rotation Frequency Measurement freq = 23.798900 Hz 11:23:41 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000325 39.876 2 0.0001634 -58.446 3 0.0000411 -90.000 11:23:49 Move Stage, position = -0.150000 11:23:51 Stage Position Measurement, pos = -0.1508600 m 11:23:52 Magnet Current, Imag = 172.6935 A Vtrans = 1.726935 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:23:55 Coil Rotation Frequency Measurement freq = 23.792300 Hz 11:27:51 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000228 37.398 2 0.0001719 -52.716 3 0.0000182 -81.786 11:28:00 Move Stage, position = -0.137500 11:28:01 Stage Position Measurement, pos = -0.1383350 m 11:28:03 Magnet Current, Imag = 172.6980 A Vtrans = 1.726980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:28:05 Coil Rotation Frequency Measurement freq = 23.799900 Hz 11:32:12 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000332 90.000 2 0.0001997 -45.492 3 0.0000322 -96.132 11:32:21 Move Stage, position = -0.125000 11:32:22 Stage Position Measurement, pos = -0.1258350 m 11:32:24 Magnet Current, Imag = 172.6895 A Vtrans = 1.726895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:32:26 Coil Rotation Frequency Measurement freq = 23.794200 Hz 11:35:55 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000779 105.414 2 0.0002441 -36.708 3 0.0000347 -47.736 11:36:04 Move Stage, position = -0.112500 11:36:05 Stage Position Measurement, pos = -0.1133250 m 11:36:07 Magnet Current, Imag = 172.6925 A Vtrans = 1.726925 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:36:09 Coil Rotation Frequency Measurement freq = 23.791300 Hz 11:39:34 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0001331 100.650 2 0.0003548 -28.104 3 0.0000162 -51.168 11:39:43 Move Stage, position = -0.100000 11:39:45 Stage Position Measurement, pos = -0.1007650 m 11:39:46 Magnet Current, Imag = 172.6917 A Vtrans = 1.726917 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:39:48 Coil Rotation Frequency Measurement freq = 23.792300 Hz 11:43:14 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0001994 113.964 2 0.0004300 -23.136 3 0.0000124 75.594 11:43:23 Move Stage, position = -0.087500 11:43:25 Stage Position Measurement, pos = -0.0882700 m 11:43:26 Magnet Current, Imag = 172.6911 A Vtrans = 1.726911 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:43:28 Coil Rotation Frequency Measurement freq = 23.779900 Hz 11:47:18 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002900 123.636 2 0.0004320 -27.822 3 0.0000228 45.168 11:47:27 Move Stage, position = -0.075000 11:47:28 Stage Position Measurement, pos = -0.0757500 m 11:47:29 Magnet Current, Imag = 172.6846 A Vtrans = 1.726846 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:47:32 Coil Rotation Frequency Measurement freq = 23.794200 Hz 11:50:58 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002841 140.022 2 0.0003872 -29.520 3 0.0000201 0.186 11:51:06 Move Stage, position = -0.062500 11:51:08 Stage Position Measurement, pos = -0.0631900 m 11:51:09 Magnet Current, Imag = 172.6955 A Vtrans = 1.726955 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:51:12 Coil Rotation Frequency Measurement freq = 23.790400 Hz 11:54:34 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002972 147.624 2 0.0003479 -39.558 3 0.0000453 -86.322 11:54:43 Move Stage, position = -0.050000 11:54:45 Stage Position Measurement, pos = -0.0506800 m 11:54:46 Magnet Current, Imag = 172.6893 A Vtrans = 1.726893 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:54:48 Coil Rotation Frequency Measurement freq = 23.802800 Hz 11:58:12 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002916 155.604 2 0.0002835 -45.258 3 0.0000407 -68.376 11:58:21 Move Stage, position = -0.037500 11:58:23 Stage Position Measurement, pos = -0.0382000 m 11:58:24 Magnet Current, Imag = 172.6851 A Vtrans = 1.726851 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:58:26 Coil Rotation Frequency Measurement freq = 23.787500 Hz 12:01:49 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003303 160.242 2 0.0002567 -52.284 3 0.0000505 -75.864 12:01:57 Move Stage, position = -0.025000 12:01:59 Stage Position Measurement, pos = -0.0255900 m 12:02:00 Magnet Current, Imag = 172.6862 A Vtrans = 1.726862 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:02:02 Coil Rotation Frequency Measurement freq = 23.795100 Hz 12:05:25 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003429 164.874 2 0.0002455 -51.726 3 0.0000487 -85.272 12:05:33 Move Stage, position = -0.012500 12:05:35 Stage Position Measurement, pos = -0.0130800 m 12:05:36 Magnet Current, Imag = 172.6844 A Vtrans = 1.726844 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:05:38 Coil Rotation Frequency Measurement freq = 23.797000 Hz 12:09:01 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003404 161.190 2 0.0002076 -48.342 3 0.0000563 -80.640 12:09:10 Move Stage, position = 0.000000 12:09:11 Stage Position Measurement, pos = -0.0006500 m 12:09:13 Magnet Current, Imag = 172.6838 A Vtrans = 1.726838 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:09:15 Coil Rotation Frequency Measurement freq = 23.789400 Hz 12:12:41 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003110 165.366 2 0.0002050 -53.520 3 0.0000675 -87.294 12:12:50 Move Stage, position = 0.012500 12:12:51 Stage Position Measurement, pos = 0.0118550 m 12:12:53 Magnet Current, Imag = 172.6818 A Vtrans = 1.726818 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:12:55 Coil Rotation Frequency Measurement freq = 23.787500 Hz 12:16:17 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002796 162.876 2 0.0002062 -53.790 3 0.0000563 -83.376 12:16:25 Move Stage, position = 0.025000 12:16:27 Stage Position Measurement, pos = 0.0244050 m 12:16:28 Magnet Current, Imag = 172.6845 A Vtrans = 1.726845 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:16:31 Coil Rotation Frequency Measurement freq = 23.796100 Hz 12:19:57 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002706 164.130 2 0.0001561 -61.728 3 0.0000447 -89.214 12:20:05 Move Stage, position = 0.037500 12:20:07 Stage Position Measurement, pos = 0.0368750 m 12:20:08 Magnet Current, Imag = 172.6822 A Vtrans = 1.726822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:20:11 Coil Rotation Frequency Measurement freq = 23.792300 Hz 12:23:32 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002758 167.544 2 0.0001695 -54.504 3 0.0000466 -82.704 12:23:41 Move Stage, position = 0.050000 12:23:43 Stage Position Measurement, pos = 0.0493850 m 12:23:44 Magnet Current, Imag = 172.6837 A Vtrans = 1.726837 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:46 Coil Rotation Frequency Measurement freq = 23.795100 Hz 12:27:06 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003185 176.112 2 0.0001977 -74.262 3 0.0000472 -85.752 12:27:14 Move Stage, position = 0.062500 12:27:16 Stage Position Measurement, pos = 0.0619300 m 12:27:17 Magnet Current, Imag = 172.6840 A Vtrans = 1.726840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:19 Coil Rotation Frequency Measurement freq = 23.795100 Hz 12:30:45 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003064 -178.308 2 0.0001677 -99.396 3 0.0000455 -64.044 12:30:54 Move Stage, position = 0.075000 12:30:55 Stage Position Measurement, pos = 0.0744650 m 12:30:57 Magnet Current, Imag = 172.6845 A Vtrans = 1.726845 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:30:59 Coil Rotation Frequency Measurement freq = 23.794200 Hz 12:34:25 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002807 -160.254 2 0.0002067 -135.252 3 0.0000665 -67.314 12:34:34 Move Stage, position = 0.087500 12:34:35 Stage Position Measurement, pos = 0.0869700 m 12:34:37 Magnet Current, Imag = 172.6840 A Vtrans = 1.726840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:34:39 Coil Rotation Frequency Measurement freq = 23.798900 Hz 12:37:57 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002414 -148.380 2 0.0002891 -148.434 3 0.0000816 -64.038 12:38:06 Move Stage, position = 0.100000 12:38:08 Stage Position Measurement, pos = 0.0994950 m 12:38:09 Magnet Current, Imag = 172.6859 A Vtrans = 1.726859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:38:11 Coil Rotation Frequency Measurement freq = 23.796100 Hz 12:41:43 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002900 -135.000 2 0.0003712 -158.346 3 0.0000612 -66.216 12:41:52 Move Stage, position = 0.112500 12:41:54 Stage Position Measurement, pos = 0.1120250 m 12:41:55 Magnet Current, Imag = 172.6858 A Vtrans = 1.726858 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:41:57 Coil Rotation Frequency Measurement freq = 23.794200 Hz 12:45:16 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0002514 -140.916 2 0.0002792 -147.816 3 0.0000670 -72.864 12:45:24 Move Stage, position = 0.125000 12:45:26 Stage Position Measurement, pos = 0.1245200 m 12:45:27 Magnet Current, Imag = 172.6862 A Vtrans = 1.726862 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:45:30 Coil Rotation Frequency Measurement freq = 23.799900 Hz 12:48:59 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0001197 -149.898 2 0.0001954 -140.334 3 0.0000454 -70.374 12:49:08 Move Stage, position = 0.137500 12:49:09 Stage Position Measurement, pos = 0.1370600 m 12:49:11 Magnet Current, Imag = 172.6841 A Vtrans = 1.726841 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:49:13 Coil Rotation Frequency Measurement freq = 23.792300 Hz 12:52:46 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000707 -150.336 2 0.0001463 -116.886 3 0.0000538 -69.942 12:52:55 Move Stage, position = 0.150000 12:52:56 Stage Position Measurement, pos = 0.1495650 m 12:52:58 Magnet Current, Imag = 172.6894 A Vtrans = 1.726894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:53:00 Coil Rotation Frequency Measurement freq = 23.778900 Hz 12:56:36 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000557 -178.572 2 0.0001306 -92.460 3 0.0000565 -64.164 12:56:45 Move Stage, position = 0.162500 12:56:46 Stage Position Measurement, pos = 0.1620250 m 12:56:48 Magnet Current, Imag = 172.6835 A Vtrans = 1.726835 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:56:50 Coil Rotation Frequency Measurement freq = 23.793200 Hz 13:00:43 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000255 123.636 2 0.0001322 -83.988 3 0.0000570 -72.270 13:00:51 Move Stage, position = 0.175000 13:00:53 Stage Position Measurement, pos = 0.1744950 m 13:00:54 Magnet Current, Imag = 172.6877 A Vtrans = 1.726877 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:00:56 Coil Rotation Frequency Measurement freq = 23.798000 Hz 13:04:33 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000243 113.562 2 0.0001299 -81.774 3 0.0000533 -67.458 13:04:41 Move Stage, position = 0.187500 13:04:43 Stage Position Measurement, pos = 0.1870400 m 13:04:44 Magnet Current, Imag = 172.6897 A Vtrans = 1.726897 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:04:47 Coil Rotation Frequency Measurement freq = 23.793200 Hz 13:08:40 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000266 101.682 2 0.0001246 -83.460 3 0.0000353 -56.022 13:08:49 Move Stage, position = 0.200000 13:08:51 Stage Position Measurement, pos = 0.1995350 m 13:08:52 Magnet Current, Imag = 172.6893 A Vtrans = 1.726893 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:54 Coil Rotation Frequency Measurement freq = 23.796100 Hz 13:12:27 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0000545 99.402 2 0.0001378 -75.486 3 0.0000511 -63.408 13:13:13 Move Stage, position = 0.000000 13:13:13 Magnet current ramping to 0.0000 A...