SLAC Magnetic Measurements Date: 01-13-2010 Time: 17:03:42 Project: LCLS Magnet Type: Quad Magnet Name: 001044 Serial Number: 50Q1 Run Number: 1 Measurement Device: dc1b_add Operator: sda Comment: Integrated Strength and some harmonics from 0-50-0 amps. Quad was degaussed, then had trip test performed. Magnetic Center Data Time Imag X sigX Y sigY (A) (microns) (microns) -------- -------- ---------+--------- ---------+--------- 17:26:23 3.912 -129.01 0.03 119.95 0.10 17:37:19 12.041 -108.59 0.07 113.71 0.11 17:59:44 32.028 -98.61 0.05 108.33 0.03 18:22:09 50.049 -96.29 0.03 107.77 0.08 18:48:25 27.965 -94.16 0.09 105.38 0.03 19:10:54 7.983 -102.67 0.07 105.29 0.06