SLAC Magnetic Measurements Date: 07-19-2019 Time: 09:53:02 Project: LCLS-II Magnet Type: Undulator Magnet Name: HXU_021 Dataset Number: 1 Run Purpose: Tuning Run Type: Pole Adjustments Measurement Device: Capacitive Sensors Pole Motion From Capacitive Sensors: Distance between sensors = 24.000 mm Relative motion from when sensors are zeroed. + move = toward gap, - move = away from gap. + angle = Quadrant 1 toward quadrant 2. Jaw Module Pole Red(Upper) Blue(Lower) Ave Move Angle (microns) (microns) (microns) (mrad) ------- ------ ------ ----------- ----------- ----------- --------- Bench 3 61 24 25 24 0.053 Aisle 3 54 24 25 24 -0.075 Bench 3 54 24 24 24 0.012 Aisle 3 24 20 19 19 0.032 Bench 3 24 19 19 19 0.005 Bench 3 23 20 19 19 -0.008 Aisle 3 23 20 20 20 -0.023 Aisle 3 68 -19 -19 -19 0.030 Aisle 3 69 -20 -20 -20 0.008 Bench 3 69 -20 -20 -20 0.003 Bench 3 68 -21 -20 -20 0.051 Aisle 3 73 19 20 20 -0.061 Aisle 3 74 21 20 20 0.046 Bench 3 74 19 20 20 0.014 Bench 3 73 20 20 20 -0.012