SLAC Magnetic Measurements Date: 05-01-2019 Time: 16:55:35 Project: LCLS-II Magnet Type: Undulator Magnet Name: HXU_003 Dataset Number: 1 Run Purpose: Tuning Run Type: Pole Adjustments Measurement Device: Capacitive Sensors Pole Motion From Capacitive Sensors: Distance between sensors = 24.000 mm Relative motion from when sensors are zeroed. + move = toward gap, - move = away from gap. + angle = Quadrant 1 toward quadrant 2. Jaw Module Pole Red(Upper) Blue(Lower) Ave Move Angle (microns) (microns) (microns) (mrad) ------- ------ ------ ----------- ----------- ----------- --------- Aisle 2 60 -22 -21 -21 -0.042 Aisle 2 65 16 16 16 0.014 Bench 2 65 15 14 14 -0.016 Bench 2 60 -21 -19 -20 0.069 Aisle 2 75 17 17 17 0.006 Bench 2 75 17 15 16 -0.079 Aisle 1 7 -15 -14 -15 -0.019 Bench 1 7 -15 -14 -14 0.028 Aisle 2 23 -10 -11 -11 0.021 Bench 2 23 -10 -11 -10 -0.025 Aisle 2 67 -14 -14 -14 -0.003 Aisle 2 68 -14 -15 -14 0.049 Bench 2 67 -15 -15 -15 -0.038 Bench 2 68 -16 -16 -16 -0.028