SLAC Magnetic Measurements Date: 04-11-2019 Time: 11:02:48 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_002 DATASET Number: 1 Tuning Stage: Tuning Run Number: 30 Measurement Type: Align X Scan Operator: VV Comment: after CAM yaw=-3 urad and X=-0.368 mm correction Position Voltage Field 0.000020 -4.039057 -0.809200 0.000030 -4.038530 -0.809094 0.000040 -4.038512 -0.809091 0.000050 -4.037296 -0.808847 0.000060 -4.037010 -0.808790 0.000070 -4.037342 -0.808856 0.000080 -4.036219 -0.808631 0.000090 -4.036463 -0.808680 0.000100 -4.035928 -0.808573 0.000110 -4.035922 -0.808572 0.000120 -4.035398 -0.808467 0.000130 -4.035372 -0.808462 0.000140 -4.035386 -0.808465 0.000150 -4.035250 -0.808437 0.000160 -4.034822 -0.808352 0.000170 -4.035177 -0.808423 0.000180 -4.034374 -0.808262 0.000190 -4.035445 -0.808476 0.000200 -4.034144 -0.808216 0.000210 -4.035450 -0.808477 0.000220 -4.034155 -0.808218 0.000230 -4.035570 -0.808501 0.000240 -4.034548 -0.808297 0.000250 -4.035014 -0.808390 0.000260 -4.035273 -0.808442 0.000270 -4.035028 -0.808393 0.000280 -4.036053 -0.808598 0.000290 -4.035066 -0.808401 0.000300 -4.036420 -0.808672 0.000310 -4.035782 -0.808544 0.000320 -4.036364 -0.808661 0.000330 -4.037141 -0.808816 0.000340 -4.036780 -0.808744 0.000350 -4.037724 -0.808933 0.000360 -4.036993 -0.808786 0.000370 -4.038955 -0.809179 0.000380 -4.037825 -0.808953 0.000390 -4.039432 -0.809275 0.000400 -4.038757 -0.809140 0.000410 -4.040954 -0.809580 0.000420 -4.039676 -0.809324 0.000430 -4.041271 -0.809643 0.000440 -4.042086 -0.809807 0.000450 -4.041199 -0.809629 0.000460 -4.043227 -0.810035 0.000470 -4.043428 -0.810075 0.000480 -4.044231 -0.810236 0.000490 -4.043882 -0.810166 0.000500 -4.045544 -0.810499 0.000510 -4.045739 -0.810538 0.000520 -4.046796 -0.810750