SLAC Magnetic Measurements Date: 04-11-2019 Time: 10:55:34 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: HXU_002 DATASET Number: 1 Tuning Stage: Tuning Run Number: 30 Measurement Type: Align X Scan Operator: VV Comment: after CAM yaw=-3 urad and X=-0.368 mm correction Position Voltage Field 0.000020 -4.044316 -0.810253 0.000030 -4.044060 -0.810202 0.000040 -4.043364 -0.810062 0.000050 -4.042008 -0.809791 0.000060 -4.042994 -0.809988 0.000070 -4.042206 -0.809830 0.000080 -4.041143 -0.809618 0.000090 -4.042587 -0.809907 0.000100 -4.040433 -0.809475 0.000110 -4.041830 -0.809755 0.000120 -4.040075 -0.809404 0.000130 -4.041455 -0.809680 0.000140 -4.039624 -0.809313 0.000150 -4.041030 -0.809595 0.000160 -4.039723 -0.809333 0.000170 -4.040660 -0.809521 0.000180 -4.039467 -0.809282 0.000190 -4.040424 -0.809474 0.000200 -4.039831 -0.809355 0.000210 -4.039848 -0.809358 0.000220 -4.040034 -0.809396 0.000230 -4.039965 -0.809382 0.000240 -4.040593 -0.809507 0.000250 -4.039866 -0.809362 0.000260 -4.040619 -0.809513 0.000270 -4.040093 -0.809407 0.000280 -4.041106 -0.809610 0.000290 -4.040614 -0.809512 0.000300 -4.041219 -0.809633 0.000310 -4.041452 -0.809679 0.000320 -4.041231 -0.809635 0.000330 -4.042290 -0.809847 0.000340 -4.041705 -0.809730 0.000350 -4.043079 -0.810005 0.000360 -4.042308 -0.809851 0.000370 -4.043975 -0.810185 0.000380 -4.043283 -0.810046 0.000390 -4.044389 -0.810268 0.000400 -4.044377 -0.810265 0.000410 -4.045308 -0.810452 0.000420 -4.045070 -0.810404 0.000430 -4.046819 -0.810754 0.000440 -4.046050 -0.810600 0.000450 -4.047477 -0.810886 0.000460 -4.048324 -0.811056 0.000470 -4.047596 -0.810910 0.000480 -4.049211 -0.811234 0.000490 -4.050055 -0.811403 0.000500 -4.051697 -0.811731 0.000510 -4.051694 -0.811731 0.000520 -4.050856 -0.811563