SLAC Magnetic Measurements Date: 09-20-2016 Time: 09:02:47 Project: LCLS_II Magnet Type: Quad Magnet Name: 4078 Serial Number: Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integrated styrength and BL vs X for coil calibration Standardization for QMAIN: 3 cycles from -6.0 A to 6.0 A to -6.0 A Test Currents for QMAIN (A): 6.00 6.00 6.00 6.00 Integrated Quadrupole Gradient Distance the wire was to be moved = 0.001500 m Number of turns in the wire = 10 Number of measurements for averaging = 6 QMAIN +/- sigma GL sigGL GL/I sigGL/I (A) (A) (T) (T) (T/A) (T/A) ------------+---------- -------------+------------ -------------+------------- 6.0041 0.0000 -4.299186 0.005384 -0.716044 0.000897 6.0041 0.0000 -4.308663 0.005483 -0.717624 0.000913 6.0041 0.0000 -4.305511 0.004712 -0.717096 0.000785 6.0041 0.0000 -4.306613 0.003650 -0.717281 0.000608