Values of wire location in magnet and Roll, Pitch and Yaw of magnet Run X Y Roll Pitch Yaw (mm) (mm) (mrad) (mrad) (mrad) 9 333.0857 262.7487 -0.4195 0.5149 2.2324 10 333.0825 262.7472 -0.4150 0.4403 1.8329 Mean 333.0841 262.7480 -0.4172 0.4776 2.0327 Std 0.0023 0.0011 0.0032 0.0527 0.2825 Error 0.000866 0.00133 Difference of wire location from Wire Detector and End Pins Run PD1X Diff PD2Y Diff PD3Y Diff PD4X Diff MagnetX Diff MagnetY Diff (microns) (microns) (microns) (microns) (microns) (microns) 9 246.4100 -242.4711 -183.2121 -63.9043 2.3154 -5.1701 10 243.0300 -245.2612 -183.3921 -66.9343 -0.8943 -6.6738 Mean 244.7200 -243.8662 -183.3021 -65.4193 0.7105 -5.9219 Std 2.3900 1.9729 0.1273 2.1426 2.2696 1.0633