SLAC Magnetic Measurements Date: 12-02-2020 Time: 15:25:29 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_020_Cell_39 Serial Number: PC33408 Run Number: 14 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full set 14 15:25:47 Ambient Measurement Device(s) Being Used, type = None 15:25:47 Magnet Voltage Measurement Device(s) Being Used, type = None 15:25:47 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:25:47 XMAG Device(s) Being Used, type = None 15:25:47 Ambient Measurement Device(s) Being Used, type = None 15:25:55   Voltage Measurement, V = 0.000000 V 15:25:56 Temperature Measurement, Probe Number = 0, T = 21.309000 C 15:25:56 Temperature Measurement, Probe Number = 1, T = 22.764000 C 15:25:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.31 P2 = 3458_Meas_Junction, Value = 22.76 15:25:56 Integrated Voltage Measurement... 15:26:22 Voltage Offset Correction: v_off_ini = 0.000000381 V, v_off_fin = 0.000001606 V 15:26:22 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.142753321 Vs 15:26:22 Integrated Voltage Measurement... 15:26:54 Voltage Offset Correction: v_off_ini = 0.000000931 V, v_off_fin = -0.000003875 V 15:26:54 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142791927 Vs 15:26:55   Voltage Measurement, V = 0.000000 V 15:26:56 Temperature Measurement, Probe Number = 0, T = 21.285000 C 15:26:57 Temperature Measurement, Probe Number = 1, T = 22.750000 C 15:26:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.29 P2 = 3458_Meas_Junction, Value = 22.75 15:26:57 Integrated Voltage Measurement... 15:27:28 Voltage Offset Correction: v_off_ini = -0.000000915 V, v_off_fin = 0.000001602 V 15:27:28 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.142861520 Vs 15:27:28 Integrated Voltage Measurement... 15:28:00 Voltage Offset Correction: v_off_ini = 0.000001195 V, v_off_fin = -0.000002057 V 15:28:00 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.142795182 Vs 15:28:01   Voltage Measurement, V = 0.000000 V 15:28:01 Temperature Measurement, Probe Number = 0, T = 21.282000 C 15:28:02 Temperature Measurement, Probe Number = 1, T = 22.787000 C 15:28:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.28 P2 = 3458_Meas_Junction, Value = 22.79 15:28:02 Integrated Voltage Measurement... 15:28:34 Voltage Offset Correction: v_off_ini = -0.000000786 V, v_off_fin = 0.000001931 V 15:28:34 Integrated Voltage Measurement Delta Gap = 0.0040019 m VT = 0.142857300 Vs 15:28:34 Integrated Voltage Measurement... 15:29:07 Voltage Offset Correction: v_off_ini = 0.000000970 V, v_off_fin = -0.000003863 V 15:29:07 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142798388 Vs 15:29:08   Voltage Measurement, V = 0.000000 V 15:29:08 Temperature Measurement, Probe Number = 0, T = 21.272000 C 15:29:09 Temperature Measurement, Probe Number = 1, T = 22.792000 C 15:29:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.27 P2 = 3458_Meas_Junction, Value = 22.79 15:29:09 Integrated Voltage Measurement... 15:29:40 Voltage Offset Correction: v_off_ini = -0.000001017 V, v_off_fin = 0.000000864 V 15:29:40 Integrated Voltage Measurement Delta Gap = 0.0040019 m VT = 0.142862274 Vs 15:29:40 Integrated Voltage Measurement... 15:30:16 Voltage Offset Correction: v_off_ini = 0.000000890 V, v_off_fin = -0.000003886 V 15:30:16 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.142784807 Vs 15:30:17   Voltage Measurement, V = 0.000000 V 15:30:18 Temperature Measurement, Probe Number = 0, T = 21.256000 C 15:30:18 Temperature Measurement, Probe Number = 1, T = 22.845000 C 15:30:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.26 P2 = 3458_Meas_Junction, Value = 22.84 15:30:18 Integrated Voltage Measurement... 15:30:50 Voltage Offset Correction: v_off_ini = -0.000000990 V, v_off_fin = 0.000001345 V 15:30:50 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142841329 Vs 15:30:50 Integrated Voltage Measurement... 15:31:22 Voltage Offset Correction: v_off_ini = 0.000001078 V, v_off_fin = -0.000003237 V 15:31:22 Integrated Voltage Measurement Delta Gap = -0.0040013 m VT = -0.142799521 Vs 15:31:23   Voltage Measurement, V = 0.000000 V 15:31:24 Temperature Measurement, Probe Number = 0, T = 21.249000 C 15:31:24 Temperature Measurement, Probe Number = 1, T = 22.861000 C 15:31:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.25 P2 = 3458_Meas_Junction, Value = 22.86 15:31:24 Integrated Voltage Measurement... 15:31:55 Voltage Offset Correction: v_off_ini = -0.000001055 V, v_off_fin = 0.000002011 V 15:31:55 Integrated Voltage Measurement Delta Gap = 0.0040019 m VT = 0.142854377 Vs 15:31:55 Integrated Voltage Measurement... 15:32:29 Voltage Offset Correction: v_off_ini = 0.000001013 V, v_off_fin = -0.000004171 V 15:32:30 Integrated Voltage Measurement Delta Gap = -0.0040016 m VT = -0.142808634 Vs 15:32:31   Voltage Measurement, V = 0.000000 V 15:32:31 Temperature Measurement, Probe Number = 0, T = 21.239000 C 15:32:32 Temperature Measurement, Probe Number = 1, T = 22.900000 C 15:32:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.24 P2 = 3458_Meas_Junction, Value = 22.90 15:32:32 Integrated Voltage Measurement... 15:33:03 Voltage Offset Correction: v_off_ini = -0.000001147 V, v_off_fin = 0.000001172 V 15:33:03 Integrated Voltage Measurement Delta Gap = 0.0040020 m VT = 0.142866346 Vs 15:33:03 Integrated Voltage Measurement... 15:33:34 Voltage Offset Correction: v_off_ini = 0.000001133 V, v_off_fin = -0.000003202 V 15:33:34 Integrated Voltage Measurement Delta Gap = -0.0040014 m VT = -0.142797053 Vs 15:33:35   Voltage Measurement, V = 0.000000 V 15:33:35 Temperature Measurement, Probe Number = 0, T = 21.236000 C 15:33:36 Temperature Measurement, Probe Number = 1, T = 22.919000 C 15:33:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.24 P2 = 3458_Meas_Junction, Value = 22.92 15:33:36 Integrated Voltage Measurement... 15:34:09 Voltage Offset Correction: v_off_ini = -0.000001074 V, v_off_fin = 0.000001602 V 15:34:09 Integrated Voltage Measurement Delta Gap = 0.0040019 m VT = 0.142861432 Vs 15:34:09 Integrated Voltage Measurement... 15:34:41 Voltage Offset Correction: v_off_ini = 0.000001092 V, v_off_fin = -0.000003825 V 15:34:41 Integrated Voltage Measurement Delta Gap = -0.0040014 m VT = -0.142801688 Vs 15:34:42   Voltage Measurement, V = 0.000000 V 15:34:42 Temperature Measurement, Probe Number = 0, T = 21.230000 C 15:34:43 Temperature Measurement, Probe Number = 1, T = 22.923000 C 15:34:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.23 P2 = 3458_Meas_Junction, Value = 22.92 15:34:43 Integrated Voltage Measurement... 15:35:15 Voltage Offset Correction: v_off_ini = -0.000000920 V, v_off_fin = 0.000001317 V 15:35:15 Integrated Voltage Measurement Delta Gap = 0.0040020 m VT = 0.142866322 Vs 15:35:15 Integrated Voltage Measurement... 15:35:45 Voltage Offset Correction: v_off_ini = 0.000001096 V, v_off_fin = -0.000004278 V 15:35:45 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.142792705 Vs 15:35:46   Voltage Measurement, V = 0.000000 V 15:35:47 Temperature Measurement, Probe Number = 0, T = 21.221000 C 15:35:47 Temperature Measurement, Probe Number = 1, T = 22.909000 C 15:35:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.22 P2 = 3458_Meas_Junction, Value = 22.91 15:35:47 Integrated Voltage Measurement... 15:36:18 Voltage Offset Correction: v_off_ini = -0.000001242 V, v_off_fin = 0.000001684 V 15:36:18 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.142846525 Vs 15:36:18 Integrated Voltage Measurement... 15:36:52 Voltage Offset Correction: v_off_ini = 0.000000976 V, v_off_fin = -0.000003473 V 15:36:52 Integrated Voltage Measurement Delta Gap = -0.0040015 m VT = -0.142800927 Vs