SLAC Magnetic Measurements Date: 10-29-2020 Time: 12:23:47 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_017_Cell_31 Serial Number: PC33408 Run Number: 12 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 12 12:24:05 Ambient Measurement Device(s) Being Used, type = None 12:24:05 Magnet Voltage Measurement Device(s) Being Used, type = None 12:24:06 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 12:24:06 XMAG Device(s) Being Used, type = None 12:24:06 Ambient Measurement Device(s) Being Used, type = None 12:24:08   Voltage Measurement, V = 0.000000 V 12:24:09 Temperature Measurement, Probe Number = 0, T = 20.828000 C 12:24:10 Temperature Measurement, Probe Number = 1, T = 21.714000 C 12:24:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.83 P2 = 3458_Meas_Junction, Value = 21.71 12:24:10 Integrated Voltage Measurement... 12:24:36 Voltage Offset Correction: v_off_ini = -0.000000077 V, v_off_fin = 0.000000809 V 12:24:36 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142347705 Vs 12:24:36 Integrated Voltage Measurement... 12:25:07 Voltage Offset Correction: v_off_ini = 0.000000828 V, v_off_fin = -0.000001795 V 12:25:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142327386 Vs 12:25:08   Voltage Measurement, V = 0.000000 V 12:25:08 Temperature Measurement, Probe Number = 0, T = 20.797000 C 12:25:09 Temperature Measurement, Probe Number = 1, T = 21.740000 C 12:25:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.80 P2 = 3458_Meas_Junction, Value = 21.74 12:25:09 Integrated Voltage Measurement... 12:25:40 Voltage Offset Correction: v_off_ini = -0.000000843 V, v_off_fin = 0.000001163 V 12:25:40 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142355809 Vs 12:25:40 Integrated Voltage Measurement... 12:26:11 Voltage Offset Correction: v_off_ini = 0.000000674 V, v_off_fin = -0.000002632 V 12:26:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142312374 Vs 12:26:12   Voltage Measurement, V = 0.000000 V 12:26:12 Temperature Measurement, Probe Number = 0, T = 20.789000 C 12:26:13 Temperature Measurement, Probe Number = 1, T = 21.749000 C 12:26:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.79 P2 = 3458_Meas_Junction, Value = 21.75 12:26:13 Integrated Voltage Measurement... 12:26:46 Voltage Offset Correction: v_off_ini = -0.000000978 V, v_off_fin = 0.000000917 V 12:26:46 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142362289 Vs 12:26:46 Integrated Voltage Measurement... 12:27:18 Voltage Offset Correction: v_off_ini = 0.000000249 V, v_off_fin = -0.000003763 V 12:27:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142324029 Vs 12:27:19   Voltage Measurement, V = 0.000000 V 12:27:20 Temperature Measurement, Probe Number = 0, T = 20.782000 C 12:27:20 Temperature Measurement, Probe Number = 1, T = 21.761000 C 12:27:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.78 P2 = 3458_Meas_Junction, Value = 21.76 12:27:20 Integrated Voltage Measurement... 12:27:52 Voltage Offset Correction: v_off_ini = -0.000001034 V, v_off_fin = 0.000000866 V 12:27:52 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142365721 Vs 12:27:52 Integrated Voltage Measurement... 12:28:24 Voltage Offset Correction: v_off_ini = 0.000000549 V, v_off_fin = -0.000001915 V 12:28:24 Integrated Voltage Measurement Delta Gap = -0.0040011 m VT = -0.142318797 Vs 12:28:25   Voltage Measurement, V = 0.000000 V 12:28:25 Temperature Measurement, Probe Number = 0, T = 20.768000 C 12:28:26 Temperature Measurement, Probe Number = 1, T = 21.760000 C 12:28:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.77 P2 = 3458_Meas_Junction, Value = 21.76 12:28:26 Integrated Voltage Measurement... 12:28:56 Voltage Offset Correction: v_off_ini = -0.000001439 V, v_off_fin = 0.000000467 V 12:28:56 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142374423 Vs 12:28:56 Integrated Voltage Measurement... 12:29:28 Voltage Offset Correction: v_off_ini = 0.000000759 V, v_off_fin = -0.000008387 V 12:29:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.142219774 Vs 12:29:29   Voltage Measurement, V = 0.000000 V 12:29:30 Temperature Measurement, Probe Number = 0, T = 20.761000 C 12:29:30 Temperature Measurement, Probe Number = 1, T = 21.751000 C 12:29:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.76 P2 = 3458_Meas_Junction, Value = 21.75 12:29:30 Integrated Voltage Measurement... 12:30:05 Voltage Offset Correction: v_off_ini = -0.000001260 V, v_off_fin = 0.000000535 V 12:30:05 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142366452 Vs 12:30:05 Integrated Voltage Measurement... 12:30:38 Voltage Offset Correction: v_off_ini = 0.000000412 V, v_off_fin = -0.000003614 V 12:30:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142318981 Vs 12:30:39   Voltage Measurement, V = 0.000000 V 12:30:39 Temperature Measurement, Probe Number = 0, T = 20.744000 C 12:30:40 Temperature Measurement, Probe Number = 1, T = 21.759000 C 12:30:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.74 P2 = 3458_Meas_Junction, Value = 21.76 12:30:40 Integrated Voltage Measurement... 12:31:11 Voltage Offset Correction: v_off_ini = -0.000001094 V, v_off_fin = 0.000000367 V 12:31:11 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.142365931 Vs 12:31:11 Integrated Voltage Measurement... 12:31:43 Voltage Offset Correction: v_off_ini = 0.000000688 V, v_off_fin = -0.000002425 V 12:31:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142312083 Vs 12:31:44   Voltage Measurement, V = 0.000000 V 12:31:44 Temperature Measurement, Probe Number = 0, T = 20.741000 C 12:31:45 Temperature Measurement, Probe Number = 1, T = 21.752000 C 12:31:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.74 P2 = 3458_Meas_Junction, Value = 21.75 12:31:45 Integrated Voltage Measurement... 12:32:18 Voltage Offset Correction: v_off_ini = -0.000000580 V, v_off_fin = 0.000000997 V 12:32:18 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.142362495 Vs 12:32:18 Integrated Voltage Measurement... 12:32:48 Voltage Offset Correction: v_off_ini = 0.000000468 V, v_off_fin = -0.000002569 V 12:32:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142314335 Vs 12:32:49   Voltage Measurement, V = 0.000000 V 12:32:50 Temperature Measurement, Probe Number = 0, T = 20.741000 C 12:32:50 Temperature Measurement, Probe Number = 1, T = 21.753000 C 12:32:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.74 P2 = 3458_Meas_Junction, Value = 21.75 12:32:50 Integrated Voltage Measurement... 12:33:21 Voltage Offset Correction: v_off_ini = -0.000001096 V, v_off_fin = 0.000001224 V 12:33:21 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.142367651 Vs 12:33:21 Integrated Voltage Measurement... 12:33:52 Voltage Offset Correction: v_off_ini = 0.000000475 V, v_off_fin = -0.000002865 V 12:33:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142308581 Vs 12:33:53   Voltage Measurement, V = 0.000000 V 12:33:54 Temperature Measurement, Probe Number = 0, T = 20.741000 C 12:33:54 Temperature Measurement, Probe Number = 1, T = 21.759000 C 12:33:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.74 P2 = 3458_Meas_Junction, Value = 21.76 12:33:54 Integrated Voltage Measurement... 12:34:25 Voltage Offset Correction: v_off_ini = -0.000000885 V, v_off_fin = 0.000000729 V 12:34:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.142362184 Vs 12:34:25 Integrated Voltage Measurement... 12:34:56 Voltage Offset Correction: v_off_ini = 0.000000733 V, v_off_fin = -0.000001630 V 12:34:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.142312113 Vs