SLAC Magnetic Measurements Date: 12-02-2020 Time: 17:23:22 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_015_Cell_47 Serial Number: PC33408 Run Number: 14 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full set 14 17:23:40 Ambient Measurement Device(s) Being Used, type = None 17:23:40 Magnet Voltage Measurement Device(s) Being Used, type = None 17:23:40 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 17:23:40 XMAG Device(s) Being Used, type = None 17:23:40 Ambient Measurement Device(s) Being Used, type = None 17:23:52   Voltage Measurement, V = 0.000000 V 17:23:52 Temperature Measurement, Probe Number = 0, T = 21.688000 C 17:23:53 Temperature Measurement, Probe Number = 1, T = 23.271000 C 17:23:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.69 P2 = 3458_Meas_Junction, Value = 23.27 17:23:53 Integrated Voltage Measurement... 17:24:19 Voltage Offset Correction: v_off_ini = 0.000000370 V, v_off_fin = 0.000001401 V 17:24:19 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142780310 Vs 17:24:19 Integrated Voltage Measurement... 17:24:51 Voltage Offset Correction: v_off_ini = 0.000000926 V, v_off_fin = -0.000001783 V 17:24:51 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142730460 Vs 17:24:52   Voltage Measurement, V = 0.000000 V 17:24:53 Temperature Measurement, Probe Number = 0, T = 21.642000 C 17:24:53 Temperature Measurement, Probe Number = 1, T = 23.210000 C 17:24:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.64 P2 = 3458_Meas_Junction, Value = 23.21 17:24:53 Integrated Voltage Measurement... 17:25:25 Voltage Offset Correction: v_off_ini = -0.000000244 V, v_off_fin = 0.000001521 V 17:25:25 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142774279 Vs 17:25:25 Integrated Voltage Measurement... 17:25:57 Voltage Offset Correction: v_off_ini = 0.000000754 V, v_off_fin = -0.000001887 V 17:25:57 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142736483 Vs 17:25:58   Voltage Measurement, V = 0.000000 V 17:25:58 Temperature Measurement, Probe Number = 0, T = 21.625000 C 17:25:59 Temperature Measurement, Probe Number = 1, T = 23.182000 C 17:25:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.62 P2 = 3458_Meas_Junction, Value = 23.18 17:25:59 Integrated Voltage Measurement... 17:26:30 Voltage Offset Correction: v_off_ini = -0.000000690 V, v_off_fin = 0.000000847 V 17:26:30 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.142789539 Vs 17:26:30 Integrated Voltage Measurement... 17:27:14 Voltage Offset Correction: v_off_ini = 0.000000896 V, v_off_fin = -0.000001798 V 17:27:14 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142765918 Vs 17:27:15   Voltage Measurement, V = 0.000000 V 17:27:15 Temperature Measurement, Probe Number = 0, T = 21.617000 C 17:27:16 Temperature Measurement, Probe Number = 1, T = 23.229000 C 17:27:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.62 P2 = 3458_Meas_Junction, Value = 23.23 17:27:16 Integrated Voltage Measurement... 17:27:47 Voltage Offset Correction: v_off_ini = -0.000000255 V, v_off_fin = 0.000001417 V 17:27:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142792713 Vs 17:27:47 Integrated Voltage Measurement... 17:28:17 Voltage Offset Correction: v_off_ini = 0.000001023 V, v_off_fin = -0.000002250 V 17:28:17 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142735139 Vs 17:28:18   Voltage Measurement, V = 0.000000 V 17:28:19 Temperature Measurement, Probe Number = 0, T = 21.617000 C 17:28:19 Temperature Measurement, Probe Number = 1, T = 23.288000 C 17:28:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.62 P2 = 3458_Meas_Junction, Value = 23.29 17:28:19 Integrated Voltage Measurement... 17:28:54 Voltage Offset Correction: v_off_ini = -0.000000325 V, v_off_fin = 0.000001524 V 17:28:54 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142792790 Vs 17:28:54 Integrated Voltage Measurement... 17:29:25 Voltage Offset Correction: v_off_ini = 0.000000845 V, v_off_fin = -0.000001829 V 17:29:26 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.142748590 Vs 17:29:27   Voltage Measurement, V = 0.000000 V 17:29:27 Temperature Measurement, Probe Number = 0, T = 21.613000 C 17:29:28 Temperature Measurement, Probe Number = 1, T = 23.333000 C 17:29:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.61 P2 = 3458_Meas_Junction, Value = 23.33 17:29:28 Integrated Voltage Measurement... 17:30:01 Voltage Offset Correction: v_off_ini = -0.000000779 V, v_off_fin = 0.000000110 V 17:30:01 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.142788378 Vs 17:30:01 Integrated Voltage Measurement... 17:30:41 Voltage Offset Correction: v_off_ini = 0.000000611 V, v_off_fin = -0.000000053 V 17:30:41 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.142729306 Vs 17:30:42   Voltage Measurement, V = 0.000000 V 17:30:43 Temperature Measurement, Probe Number = 0, T = 21.597000 C 17:30:43 Temperature Measurement, Probe Number = 1, T = 23.260000 C 17:30:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.60 P2 = 3458_Meas_Junction, Value = 23.26 17:30:43 Integrated Voltage Measurement... 17:31:20 Voltage Offset Correction: v_off_ini = 0.000000146 V, v_off_fin = -0.000000183 V 17:31:20 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.142747826 Vs 17:31:20 Integrated Voltage Measurement... 17:31:53 Voltage Offset Correction: v_off_ini = 0.000000711 V, v_off_fin = -0.000002057 V 17:31:53 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142722938 Vs 17:31:54   Voltage Measurement, V = 0.000000 V 17:31:55 Temperature Measurement, Probe Number = 0, T = 21.577000 C 17:31:55 Temperature Measurement, Probe Number = 1, T = 23.204000 C 17:31:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.58 P2 = 3458_Meas_Junction, Value = 23.20 17:31:55 Integrated Voltage Measurement... 17:32:27 Voltage Offset Correction: v_off_ini = -0.000000555 V, v_off_fin = 0.000000826 V 17:32:27 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.142778876 Vs 17:32:27 Integrated Voltage Measurement... 17:32:59 Voltage Offset Correction: v_off_ini = 0.000000641 V, v_off_fin = -0.000002779 V 17:32:59 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.142755855 Vs 17:33:00   Voltage Measurement, V = 0.000000 V 17:33:00 Temperature Measurement, Probe Number = 0, T = 21.566000 C 17:33:01 Temperature Measurement, Probe Number = 1, T = 23.185000 C 17:33:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.57 P2 = 3458_Meas_Junction, Value = 23.18 17:33:01 Integrated Voltage Measurement... 17:33:32 Voltage Offset Correction: v_off_ini = -0.000000505 V, v_off_fin = 0.000001459 V 17:33:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142800027 Vs 17:33:32 Integrated Voltage Measurement... 17:34:03 Voltage Offset Correction: v_off_ini = 0.000000736 V, v_off_fin = -0.000002193 V 17:34:03 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.142745124 Vs 17:34:04   Voltage Measurement, V = 0.000000 V 17:34:05 Temperature Measurement, Probe Number = 0, T = 21.561000 C 17:34:05 Temperature Measurement, Probe Number = 1, T = 23.115000 C 17:34:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.56 P2 = 3458_Meas_Junction, Value = 23.11 17:34:05 Integrated Voltage Measurement... 17:34:39 Voltage Offset Correction: v_off_ini = -0.000000721 V, v_off_fin = 0.000000626 V 17:34:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.142804594 Vs 17:34:39 Integrated Voltage Measurement... 17:35:17 Voltage Offset Correction: v_off_ini = 0.000000661 V, v_off_fin = -0.000000485 V 17:35:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142728004 Vs