SLAC Magnetic Measurements Date: 09-09-2020 Time: 22:06:27 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_010_Cell_32_Upstairs Serial Number: PC97084 Run Number: 1 Measurement Device: WalkerVS Operator: sda Comment: Coil Integral measurement upstairs, cable straight into 3458A. Set 1 22:06:30 Ambient Measurement Device(s) Being Used, type = None 22:06:30 Magnet Voltage Measurement Device(s) Being Used, type = None 22:06:30 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 22:06:30 XMAG Device(s) Being Used, type = None 22:06:30 Ambient Measurement Device(s) Being Used, type = None 22:06:53   Voltage Measurement, V = 0.000000 V 22:06:54 Temperature Measurement, Probe Number = 0, T = 23.139000 C 22:06:54 Temperature Measurement, Probe Number = 1, T = 24.047000 C 22:06:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.14 P2 = 3458_Meas_Junction, Value = 24.05 22:06:54 Integrated Voltage Measurement... 22:07:28 Voltage Offset Correction: v_off_ini = -0.000002628 V, v_off_fin = -0.000002966 V 22:07:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = -0.143257290 Vs 22:07:28 Integrated Voltage Measurement... 22:08:02 Voltage Offset Correction: v_off_ini = -0.000002733 V, v_off_fin = -0.000001288 V 22:08:02 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = 0.143212245 Vs 22:08:03   Voltage Measurement, V = 0.000000 V 22:08:04 Temperature Measurement, Probe Number = 0, T = 23.078000 C 22:08:04 Temperature Measurement, Probe Number = 1, T = 23.973000 C 22:08:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.08 P2 = 3458_Meas_Junction, Value = 23.97 22:08:04 Integrated Voltage Measurement... 22:08:36 Voltage Offset Correction: v_off_ini = -0.000002166 V, v_off_fin = -0.000003283 V 22:08:36 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.143233477 Vs 22:08:36 Integrated Voltage Measurement... 22:09:10 Voltage Offset Correction: v_off_ini = -0.000002900 V, v_off_fin = -0.000000667 V 22:09:10 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.143211771 Vs 22:09:11   Voltage Measurement, V = 0.000000 V 22:09:11 Temperature Measurement, Probe Number = 0, T = 23.062000 C 22:09:12 Temperature Measurement, Probe Number = 1, T = 23.953000 C 22:09:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.06 P2 = 3458_Meas_Junction, Value = 23.95 22:09:12 Integrated Voltage Measurement... 22:09:50 Voltage Offset Correction: v_off_ini = -0.000002380 V, v_off_fin = -0.000003509 V 22:09:50 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.143234228 Vs 22:09:50 Integrated Voltage Measurement... 22:10:22 Voltage Offset Correction: v_off_ini = -0.000003115 V, v_off_fin = -0.000002002 V 22:10:22 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = 0.143212739 Vs 22:10:23   Voltage Measurement, V = 0.000000 V 22:10:24 Temperature Measurement, Probe Number = 0, T = 23.058000 C 22:10:24 Temperature Measurement, Probe Number = 1, T = 23.925000 C 22:10:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.06 P2 = 3458_Meas_Junction, Value = 23.93 22:10:24 Integrated Voltage Measurement... 22:10:55 Voltage Offset Correction: v_off_ini = -0.000001938 V, v_off_fin = -0.000002972 V 22:10:55 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.143237331 Vs 22:10:55 Integrated Voltage Measurement... 22:11:27 Voltage Offset Correction: v_off_ini = -0.000003059 V, v_off_fin = -0.000000834 V 22:11:27 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = 0.143213679 Vs 22:11:28   Voltage Measurement, V = 0.000000 V 22:11:29 Temperature Measurement, Probe Number = 0, T = 23.059000 C 22:11:29 Temperature Measurement, Probe Number = 1, T = 23.886000 C 22:11:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.06 P2 = 3458_Meas_Junction, Value = 23.89 22:11:29 Integrated Voltage Measurement... 22:12:03 Voltage Offset Correction: v_off_ini = -0.000002153 V, v_off_fin = -0.000003551 V 22:12:03 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = -0.143236930 Vs 22:12:03 Integrated Voltage Measurement... 22:12:35 Voltage Offset Correction: v_off_ini = -0.000002831 V, v_off_fin = -0.000001741 V 22:12:35 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.143211793 Vs 22:12:36   Voltage Measurement, V = 0.000000 V 22:12:37 Temperature Measurement, Probe Number = 0, T = 23.043000 C 22:12:37 Temperature Measurement, Probe Number = 1, T = 23.882000 C 22:12:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.04 P2 = 3458_Meas_Junction, Value = 23.88 22:12:37 Integrated Voltage Measurement... 22:13:13 Voltage Offset Correction: v_off_ini = -0.000002075 V, v_off_fin = -0.000002478 V 22:13:13 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.143231454 Vs 22:13:13 Integrated Voltage Measurement... 22:13:51 Voltage Offset Correction: v_off_ini = -0.000002852 V, v_off_fin = -0.000001594 V 22:13:51 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.143202522 Vs 22:13:52   Voltage Measurement, V = 0.000000 V 22:13:53 Temperature Measurement, Probe Number = 0, T = 23.040000 C 22:13:53 Temperature Measurement, Probe Number = 1, T = 23.859000 C 22:13:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.04 P2 = 3458_Meas_Junction, Value = 23.86 22:13:53 Integrated Voltage Measurement... 22:14:26 Voltage Offset Correction: v_off_ini = -0.000002017 V, v_off_fin = -0.000002565 V 22:14:26 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.143237339 Vs 22:14:26 Integrated Voltage Measurement... 22:14:57 Voltage Offset Correction: v_off_ini = -0.000002937 V, v_off_fin = -0.000001446 V 22:14:57 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.143207288 Vs 22:14:59   Voltage Measurement, V = 0.000000 V 22:14:59 Temperature Measurement, Probe Number = 0, T = 23.045000 C 22:15:00 Temperature Measurement, Probe Number = 1, T = 23.832000 C 22:15:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.05 P2 = 3458_Meas_Junction, Value = 23.83 22:15:00 Integrated Voltage Measurement... 22:15:35 Voltage Offset Correction: v_off_ini = -0.000002029 V, v_off_fin = -0.000003504 V 22:15:35 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.143225550 Vs 22:15:35 Integrated Voltage Measurement... 22:16:08 Voltage Offset Correction: v_off_ini = -0.000003081 V, v_off_fin = -0.000001353 V 22:16:08 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = 0.143223239 Vs 22:16:09   Voltage Measurement, V = 0.000000 V 22:16:09 Temperature Measurement, Probe Number = 0, T = 23.026000 C 22:16:10 Temperature Measurement, Probe Number = 1, T = 23.812000 C 22:16:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.03 P2 = 3458_Meas_Junction, Value = 23.81 22:16:10 Integrated Voltage Measurement... 22:16:43 Voltage Offset Correction: v_off_ini = -0.000002050 V, v_off_fin = -0.000004374 V 22:16:43 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = -0.143234600 Vs 22:16:43 Integrated Voltage Measurement... 22:18:11 Voltage Offset Correction: v_off_ini = -0.000002968 V, v_off_fin = -0.000001090 V 22:18:11 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.143213528 Vs 22:18:12   Voltage Measurement, V = 0.000000 V 22:18:12 Temperature Measurement, Probe Number = 0, T = 23.026000 C 22:18:13 Temperature Measurement, Probe Number = 1, T = 23.796000 C 22:18:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.03 P2 = 3458_Meas_Junction, Value = 23.80 22:18:13 Integrated Voltage Measurement... 22:18:46 Voltage Offset Correction: v_off_ini = -0.000001887 V, v_off_fin = -0.000004042 V 22:18:46 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = -0.143233468 Vs 22:18:46 Integrated Voltage Measurement... 22:19:19 Voltage Offset Correction: v_off_ini = -0.000002850 V, v_off_fin = -0.000000425 V 22:19:19 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = 0.143219865 Vs