SLAC Magnetic Measurements Date: 07-14-2020 Time: 16:41:08 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_009_Cell_36 Serial Number: HP_PC33408 Run Number: 6 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 6 16:41:11 Ambient Measurement Device(s) Being Used, type = None 16:41:11 Magnet Voltage Measurement Device(s) Being Used, type = None 16:41:11 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:41:11 XMAG Device(s) Being Used, type = None 16:41:11 Ambient Measurement Device(s) Being Used, type = None 16:41:15   Voltage Measurement, V = 0.000000 V 16:41:16 Temperature Measurement, Probe Number = 0, T = 21.890000 C 16:41:17 Temperature Measurement, Probe Number = 1, T = 22.721000 C 16:41:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.89 P2 = 3458_Meas_Junction, Value = 22.72 16:41:17 Integrated Voltage Measurement... 16:41:54 Voltage Offset Correction: v_off_ini = -0.000000901 V, v_off_fin = -0.000000077 V 16:41:54 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.143407364 Vs 16:41:54 Integrated Voltage Measurement... 16:42:27 Voltage Offset Correction: v_off_ini = -0.000000297 V, v_off_fin = -0.000003099 V 16:42:27 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.143332250 Vs 16:42:28   Voltage Measurement, V = 0.000000 V 16:42:28 Temperature Measurement, Probe Number = 0, T = 21.924000 C 16:42:29 Temperature Measurement, Probe Number = 1, T = 22.714000 C 16:42:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.92 P2 = 3458_Meas_Junction, Value = 22.71 16:42:29 Integrated Voltage Measurement... 16:43:04 Voltage Offset Correction: v_off_ini = -0.000001578 V, v_off_fin = 0.000000102 V 16:43:04 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143375841 Vs 16:43:04 Integrated Voltage Measurement... 16:43:35 Voltage Offset Correction: v_off_ini = -0.000000336 V, v_off_fin = -0.000002244 V 16:43:35 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143340524 Vs 16:43:36   Voltage Measurement, V = 0.000000 V 16:43:37 Temperature Measurement, Probe Number = 0, T = 21.976000 C 16:43:37 Temperature Measurement, Probe Number = 1, T = 22.744000 C 16:43:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.98 P2 = 3458_Meas_Junction, Value = 22.74 16:43:37 Integrated Voltage Measurement... 16:44:10 Voltage Offset Correction: v_off_ini = -0.000001678 V, v_off_fin = 0.000000163 V 16:44:10 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143376759 Vs 16:44:10 Integrated Voltage Measurement... 16:44:44 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000002388 V 16:44:44 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143346865 Vs 16:44:45   Voltage Measurement, V = 0.000000 V 16:44:46 Temperature Measurement, Probe Number = 0, T = 21.999000 C 16:44:47 Temperature Measurement, Probe Number = 1, T = 22.768000 C 16:44:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 22.00 P2 = 3458_Meas_Junction, Value = 22.77 16:44:47 Integrated Voltage Measurement... 16:45:19 Voltage Offset Correction: v_off_ini = -0.000001705 V, v_off_fin = 0.000000122 V 16:45:19 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.143381728 Vs 16:45:19 Integrated Voltage Measurement... 16:45:50 Voltage Offset Correction: v_off_ini = -0.000000175 V, v_off_fin = -0.000002877 V 16:45:50 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143333972 Vs 16:45:51   Voltage Measurement, V = 0.000000 V 16:45:52 Temperature Measurement, Probe Number = 0, T = 21.981000 C 16:45:52 Temperature Measurement, Probe Number = 1, T = 22.771000 C 16:45:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.98 P2 = 3458_Meas_Junction, Value = 22.77 16:45:52 Integrated Voltage Measurement... 16:46:26 Voltage Offset Correction: v_off_ini = -0.000001878 V, v_off_fin = 0.000000536 V 16:46:26 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143374102 Vs 16:46:26 Integrated Voltage Measurement... 16:46:57 Voltage Offset Correction: v_off_ini = -0.000000074 V, v_off_fin = -0.000004117 V 16:46:57 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.143334916 Vs 16:46:58   Voltage Measurement, V = 0.000000 V 16:46:58 Temperature Measurement, Probe Number = 0, T = 21.971000 C 16:46:59 Temperature Measurement, Probe Number = 1, T = 22.789000 C 16:46:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.97 P2 = 3458_Meas_Junction, Value = 22.79 16:46:59 Integrated Voltage Measurement... 16:47:39 Voltage Offset Correction: v_off_ini = -0.000001578 V, v_off_fin = -0.000000032 V 16:47:39 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143381390 Vs 16:47:39 Integrated Voltage Measurement... 16:48:10 Voltage Offset Correction: v_off_ini = -0.000000246 V, v_off_fin = -0.000003735 V 16:48:10 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143346471 Vs 16:48:11   Voltage Measurement, V = 0.000000 V 16:48:12 Temperature Measurement, Probe Number = 0, T = 21.948000 C 16:48:12 Temperature Measurement, Probe Number = 1, T = 22.797000 C 16:48:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.95 P2 = 3458_Meas_Junction, Value = 22.80 16:48:12 Integrated Voltage Measurement... 16:48:46 Voltage Offset Correction: v_off_ini = -0.000001667 V, v_off_fin = 0.000002202 V 16:48:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.143390498 Vs 16:48:46 Integrated Voltage Measurement... 16:49:16 Voltage Offset Correction: v_off_ini = 0.000000112 V, v_off_fin = -0.000004238 V 16:49:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143340469 Vs 16:49:17   Voltage Measurement, V = 0.000000 V 16:49:17 Temperature Measurement, Probe Number = 0, T = 21.918000 C 16:49:18 Temperature Measurement, Probe Number = 1, T = 22.797000 C 16:49:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.92 P2 = 3458_Meas_Junction, Value = 22.80 16:49:18 Integrated Voltage Measurement... 16:49:49 Voltage Offset Correction: v_off_ini = -0.000001943 V, v_off_fin = -0.000000393 V 16:49:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143388344 Vs 16:49:49 Integrated Voltage Measurement... 16:50:20 Voltage Offset Correction: v_off_ini = -0.000000065 V, v_off_fin = -0.000003367 V 16:50:20 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.143334663 Vs 16:50:21   Voltage Measurement, V = 0.000000 V 16:50:21 Temperature Measurement, Probe Number = 0, T = 21.902000 C 16:50:22 Temperature Measurement, Probe Number = 1, T = 22.796000 C 16:50:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.90 P2 = 3458_Meas_Junction, Value = 22.80 16:50:22 Integrated Voltage Measurement... 16:50:54 Voltage Offset Correction: v_off_ini = -0.000001789 V, v_off_fin = -0.000000048 V 16:50:54 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.143371916 Vs 16:50:54 Integrated Voltage Measurement... 16:51:49 Voltage Offset Correction: v_off_ini = 0.000000037 V, v_off_fin = -0.000002404 V 16:51:49 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143337971 Vs 16:51:50   Voltage Measurement, V = 0.000000 V 16:51:51 Temperature Measurement, Probe Number = 0, T = 21.886000 C 16:51:51 Temperature Measurement, Probe Number = 1, T = 22.780000 C 16:51:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.89 P2 = 3458_Meas_Junction, Value = 22.78 16:51:51 Integrated Voltage Measurement... 16:52:25 Voltage Offset Correction: v_off_ini = -0.000001107 V, v_off_fin = 0.000000698 V 16:52:25 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.143377645 Vs 16:52:25 Integrated Voltage Measurement... 16:52:58 Voltage Offset Correction: v_off_ini = -0.000000048 V, v_off_fin = -0.000003157 V 16:52:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.143334984 Vs