SLAC Magnetic Measurements Date: 12-08-2015 Time: 10:55:12 Project: LCLS2 Magnet Type: Coil Magnet Name: Test_Coil Serial Number: Run Number: 6 Measurement Device: 18_pole_36_Turn Operator: sda Comment: Test of 18 pole flexible pc board. Each coil has 36 coils. 10 measurements Num Int = 6, Num Avg = 6, NPLC = 22 10:55:15 Ambient Measurement Device(s) Being Used, type = None 10:55:15 Magnet Voltage Measurement Device(s) Being Used, type = None 10:55:15 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 10:55:15 XMAG Device(s) Being Used, type = None 10:55:15 Ambient Measurement Device(s) Being Used, type = None 10:55:15 8` Voltage Measurement, V = 0.000000 V 10:55:16 Temperature Measurement, Probe Number = 0, T = 18.612000 C 10:55:17 Temperature Measurement, Probe Number = 1, T = 19.280000 C 10:55:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 18.61 P2 = Ambient, Value = 19.28 10:55:17 Integrated Voltage Measurement... 10:55:34 Voltage Offset Correction: v_off_ini = -0.000021971 V, v_off_fin = 0.000018583 V 10:55:34 Integrated Voltage Measurement Delta Gap = 0.0020032 m VT = 0.058490374 Vs 10:55:34 Integrated Voltage Measurement... 10:55:51 Voltage Offset Correction: v_off_ini = 0.000016450 V, v_off_fin = -0.000007570 V 10:55:51 Integrated Voltage Measurement Delta Gap = -0.0020027 m VT = -0.058470351 Vs 10:56:01 8` Voltage Measurement, V = 0.000000 V 10:56:02 Temperature Measurement, Probe Number = 0, T = 18.619000 C 10:56:03 Temperature Measurement, Probe Number = 1, T = 19.274000 C 10:56:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 18.62 P2 = Ambient, Value = 19.27 10:56:04 Integrated Voltage Measurement... 10:56:25 Voltage Offset Correction: v_off_ini = 0.000025696 V, v_off_fin = -0.000024564 V 10:56:25 Integrated Voltage Measurement Delta Gap = 0.0020027 m VT = 0.058450548 Vs 10:56:25 Integrated Voltage Measurement... 10:56:42 Voltage Offset Correction: v_off_ini = 0.000015218 V, v_off_fin = -0.000015089 V 10:56:42 Integrated Voltage Measurement Delta Gap = -0.0020019 m VT = -0.058376868 Vs 10:56:52 8` Voltage Measurement, V = 0.000000 V 10:56:53 Temperature Measurement, Probe Number = 0, T = 18.621000 C 10:56:54 Temperature Measurement, Probe Number = 1, T = 19.284000 C 10:56:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 18.62 P2 = Ambient, Value = 19.28 10:56:54 Integrated Voltage Measurement... 10:57:11 Voltage Offset Correction: v_off_ini = 0.000022039 V, v_off_fin = -0.000013948 V 10:57:11 Integrated Voltage Measurement Delta Gap = 0.0020025 m VT = 0.058391721 Vs 10:57:11 Integrated Voltage Measurement... 10:57:28 Voltage Offset Correction: v_off_ini = 0.000003134 V, v_off_fin = -0.000017237 V 10:57:28 Integrated Voltage Measurement Delta Gap = -0.0020026 m VT = -0.058318061 Vs 10:57:38 8` Voltage Measurement, V = 0.000000 V 10:57:39 Temperature Measurement, Probe Number = 0, T = 18.621000 C 10:57:39 Temperature Measurement, Probe Number = 1, T = 19.302000 C 10:57:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 18.62 P2 = Ambient, Value = 19.30 10:57:39 Integrated Voltage Measurement... 10:58:00 Voltage Offset Correction: v_off_ini = -0.000014251 V, v_off_fin = 0.000027892 V 10:58:00 Integrated Voltage Measurement Delta Gap = 0.0020027 m VT = 0.058360269 Vs 10:58:00 Integrated Voltage Measurement... 10:58:17 Voltage Offset Correction: v_off_ini = -0.000017692 V, v_off_fin = 0.000005871 V 10:58:17 Integrated Voltage Measurement Delta Gap = -0.0020022 m VT = -0.058318697 Vs 10:58:27 8` Voltage Measurement, V = 0.000000 V 10:58:28 Temperature Measurement, Probe Number = 0, T = 18.624000 C 10:58:29 Temperature Measurement, Probe Number = 1, T = 19.303000 C 10:58:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 18.62 P2 = Ambient, Value = 19.30 10:58:29 Integrated Voltage Measurement... 10:58:50 Voltage Offset Correction: v_off_ini = 0.000023602 V, v_off_fin = -0.000018557 V 10:58:50 Integrated Voltage Measurement Delta Gap = 0.0020019 m VT = 0.058400731 Vs 10:58:50 Integrated Voltage Measurement... 10:59:10 Voltage Offset Correction: v_off_ini = -0.000007227 V, v_off_fin = -0.000022484 V 10:59:10 Integrated Voltage Measurement Delta Gap = -0.0020019 m VT = -0.058155616 Vs 10:59:21 8` Voltage Measurement, V = 0.000000 V 10:59:21 Temperature Measurement, Probe Number = 0, T = 18.624000 C 10:59:22 Temperature Measurement, Probe Number = 1, T = 19.310000 C 10:59:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 18.62 P2 = Ambient, Value = 19.31 10:59:22 Integrated Voltage Measurement... 10:59:43 Voltage Offset Correction: v_off_ini = -0.000009093 V, v_off_fin = 0.000015661 V 10:59:43 Integrated Voltage Measurement Delta Gap = 0.0020028 m VT = 0.058398996 Vs 10:59:43 Integrated Voltage Measurement... 11:00:04 Voltage Offset Correction: v_off_ini = 0.000006100 V, v_off_fin = -0.000030660 V 11:00:04 Integrated Voltage Measurement Delta Gap = -0.0020025 m VT = -0.058200821 Vs 11:00:14 8` Voltage Measurement, V = 0.000000 V 11:00:15 Temperature Measurement, Probe Number = 0, T = 18.625000 C 11:00:16 Temperature Measurement, Probe Number = 1, T = 19.295000 C 11:00:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 18.62 P2 = Ambient, Value = 19.30 11:00:17 Integrated Voltage Measurement... 11:00:37 Voltage Offset Correction: v_off_ini = -0.000024461 V, v_off_fin = 0.000025449 V 11:00:37 Integrated Voltage Measurement Delta Gap = 0.0020027 m VT = 0.058428638 Vs 11:00:38 Integrated Voltage Measurement... 11:00:55 Voltage Offset Correction: v_off_ini = -0.000020338 V, v_off_fin = 0.000017656 V 11:00:55 Integrated Voltage Measurement Delta Gap = -0.0020032 m VT = -0.058412343 Vs 11:01:06 8` Voltage Measurement, V = 0.000000 V 11:01:07 Temperature Measurement, Probe Number = 0, T = 18.627000 C 11:01:08 Temperature Measurement, Probe Number = 1, T = 19.301000 C 11:01:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 18.63 P2 = Ambient, Value = 19.30 11:01:08 Integrated Voltage Measurement... 11:01:29 Voltage Offset Correction: v_off_ini = 0.000023964 V, v_off_fin = 0.000012683 V 11:01:30 Integrated Voltage Measurement Delta Gap = 0.0020037 m VT = 0.058226068 Vs 11:01:30 Integrated Voltage Measurement... 11:01:51 Voltage Offset Correction: v_off_ini = 0.000013741 V, v_off_fin = -0.000011008 V 11:01:52 Integrated Voltage Measurement Delta Gap = -0.0020028 m VT = -0.058405908 Vs 11:02:02 8` Voltage Measurement, V = 0.000000 V 11:02:03 Temperature Measurement, Probe Number = 0, T = 18.628000 C 11:02:04 Temperature Measurement, Probe Number = 1, T = 19.302000 C 11:02:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 18.63 P2 = Ambient, Value = 19.30 11:02:05 Integrated Voltage Measurement... 11:02:22 Voltage Offset Correction: v_off_ini = 0.000025223 V, v_off_fin = -0.000026956 V 11:02:22 Integrated Voltage Measurement Delta Gap = 0.0020033 m VT = 0.058471149 Vs 11:02:23 Integrated Voltage Measurement... 11:02:44 Voltage Offset Correction: v_off_ini = 0.000027542 V, v_off_fin = -0.000029617 V 11:02:44 Integrated Voltage Measurement Delta Gap = -0.0020035 m VT = -0.058401878 Vs 11:02:54 8` Voltage Measurement, V = 0.000000 V 11:02:55 Temperature Measurement, Probe Number = 0, T = 18.632000 C 11:02:55 Temperature Measurement, Probe Number = 1, T = 19.305000 C 11:02:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 18.63 P2 = Ambient, Value = 19.30 11:02:56 Integrated Voltage Measurement... 11:03:13 Voltage Offset Correction: v_off_ini = 0.000026169 V, v_off_fin = -0.000009844 V 11:03:13 Integrated Voltage Measurement Delta Gap = 0.0020043 m VT = 0.058369295 Vs 11:03:13 Integrated Voltage Measurement... 11:03:33 Voltage Offset Correction: v_off_ini = 0.000014402 V, v_off_fin = -0.000001603 V 11:03:33 Integrated Voltage Measurement Delta Gap = -0.0020037 m VT = -0.058510241 Vs