SLAC Magnetic Measurements Date: 12-09-2015 Time: 17:06:15 Project: LCLS2 Magnet Type: Coil Magnet Name: Test_Coil Serial Number: Run Number: 23 Measurement Device: 18_pole_36_Turn Operator: sda Comment: Retries set to 0 from 1 17:06:18 Ambient Measurement Device(s) Being Used, type = None 17:06:18 Magnet Voltage Measurement Device(s) Being Used, type = None 17:06:18 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 17:06:19 XMAG Device(s) Being Used, type = None 17:06:19 Ambient Measurement Device(s) Being Used, type = None 17:06:19 8` Voltage Measurement, V = 0.000000 V 17:06:20 Temperature Measurement, Probe Number = 0, T = 20.316000 C 17:06:20 Temperature Measurement, Probe Number = 1, T = 21.285000 C 17:06:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 20.32 P2 = Ambient, Value = 21.29 17:06:21 Integrated Voltage Measurement... 17:06:38 Voltage Offset Correction: v_off_ini = 0.000000291 V, v_off_fin = 0.000001273 V 17:06:38 Integrated Voltage Measurement Delta Gap = 0.0020039 m VT = 0.056923058 Vs 17:06:38 Integrated Voltage Measurement... 17:06:59 Voltage Offset Correction: v_off_ini = 0.000001711 V, v_off_fin = -0.000000517 V 17:06:59 Integrated Voltage Measurement Delta Gap = -0.0020040 m VT = -0.056910529 Vs 17:07:09 8` Voltage Measurement, V = 0.000000 V 17:07:10 Temperature Measurement, Probe Number = 0, T = 20.323000 C 17:07:11 Temperature Measurement, Probe Number = 1, T = 21.285000 C 17:07:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 20.32 P2 = Ambient, Value = 21.29 17:07:11 Integrated Voltage Measurement... 17:07:32 Voltage Offset Correction: v_off_ini = 0.000001455 V, v_off_fin = -0.000000723 V 17:07:32 Integrated Voltage Measurement Delta Gap = 0.0020034 m VT = 0.056914191 Vs 17:07:32 Integrated Voltage Measurement... 17:07:53 Voltage Offset Correction: v_off_ini = 0.000002684 V, v_off_fin = -0.000000725 V 17:07:53 Integrated Voltage Measurement Delta Gap = -0.0020024 m VT = -0.056862866 Vs 17:08:03 8` Voltage Measurement, V = 0.000000 V 17:08:04 Temperature Measurement, Probe Number = 0, T = 20.325000 C 17:08:05 Temperature Measurement, Probe Number = 1, T = 21.280000 C 17:08:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 20.32 P2 = Ambient, Value = 21.28 17:08:05 Integrated Voltage Measurement... 17:08:26 Voltage Offset Correction: v_off_ini = 0.000001237 V, v_off_fin = 0.000000639 V 17:08:26 Integrated Voltage Measurement Delta Gap = 0.0020020 m VT = 0.056866890 Vs 17:08:26 Integrated Voltage Measurement... 17:08:47 Voltage Offset Correction: v_off_ini = 0.000002505 V, v_off_fin = 0.000001386 V 17:08:47 Integrated Voltage Measurement Delta Gap = -0.0020026 m VT = -0.056890747 Vs 17:08:57 8` Voltage Measurement, V = 0.000000 V 17:08:58 Temperature Measurement, Probe Number = 0, T = 20.326000 C 17:08:59 Temperature Measurement, Probe Number = 1, T = 21.278000 C 17:08:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 20.33 P2 = Ambient, Value = 21.28 17:08:59 Integrated Voltage Measurement... 17:09:16 Voltage Offset Correction: v_off_ini = 0.000000175 V, v_off_fin = -0.000000738 V 17:09:16 Integrated Voltage Measurement Delta Gap = 0.0020039 m VT = 0.056938022 Vs 17:09:16 Integrated Voltage Measurement... 17:09:37 Voltage Offset Correction: v_off_ini = 0.000000579 V, v_off_fin = 0.000000762 V 17:09:37 Integrated Voltage Measurement Delta Gap = -0.0020041 m VT = -0.056912140 Vs 17:09:48 8` Voltage Measurement, V = 0.000000 V 17:09:48 Temperature Measurement, Probe Number = 0, T = 20.329000 C 17:09:49 Temperature Measurement, Probe Number = 1, T = 21.290000 C 17:09:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 20.33 P2 = Ambient, Value = 21.29 17:09:49 Integrated Voltage Measurement... 17:10:10 Voltage Offset Correction: v_off_ini = 0.000001630 V, v_off_fin = 0.000002197 V 17:10:10 Integrated Voltage Measurement Delta Gap = 0.0020030 m VT = 0.056882717 Vs 17:10:10 Integrated Voltage Measurement... 17:10:31 Voltage Offset Correction: v_off_ini = 0.000003091 V, v_off_fin = -0.000001308 V 17:10:32 Integrated Voltage Measurement Delta Gap = -0.0020019 m VT = -0.056894479 Vs 17:10:42 8` Voltage Measurement, V = 0.000000 V 17:10:42 Temperature Measurement, Probe Number = 0, T = 20.331000 C 17:10:43 Temperature Measurement, Probe Number = 1, T = 21.290000 C 17:10:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 20.33 P2 = Ambient, Value = 21.29 17:10:43 Integrated Voltage Measurement... 17:11:04 Voltage Offset Correction: v_off_ini = -0.000001103 V, v_off_fin = 0.000001292 V 17:11:04 Integrated Voltage Measurement Delta Gap = 0.0020023 m VT = 0.056875537 Vs 17:11:04 Integrated Voltage Measurement... 17:11:25 Voltage Offset Correction: v_off_ini = 0.000000688 V, v_off_fin = 0.000001297 V 17:11:26 Integrated Voltage Measurement Delta Gap = -0.0020030 m VT = -0.056881837 Vs 17:11:36 8` Voltage Measurement, V = 0.000000 V 17:11:36 Temperature Measurement, Probe Number = 0, T = 20.332000 C 17:11:37 Temperature Measurement, Probe Number = 1, T = 21.277000 C 17:11:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 20.33 P2 = Ambient, Value = 21.28 17:11:37 Integrated Voltage Measurement... 17:11:58 Voltage Offset Correction: v_off_ini = 0.000001170 V, v_off_fin = 0.000003163 V 17:11:58 Integrated Voltage Measurement Delta Gap = 0.0020028 m VT = 0.056876211 Vs 17:11:58 Integrated Voltage Measurement... 17:12:19 Voltage Offset Correction: v_off_ini = 0.000002730 V, v_off_fin = 0.000000246 V 17:12:19 Integrated Voltage Measurement Delta Gap = -0.0020026 m VT = -0.056887566 Vs 17:12:30 8` Voltage Measurement, V = 0.000000 V 17:12:30 Temperature Measurement, Probe Number = 0, T = 20.334000 C 17:12:31 Temperature Measurement, Probe Number = 1, T = 21.283000 C 17:12:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 20.33 P2 = Ambient, Value = 21.28 17:12:31 Integrated Voltage Measurement... 17:12:52 Voltage Offset Correction: v_off_ini = 0.000001353 V, v_off_fin = 0.000001703 V 17:12:52 Integrated Voltage Measurement Delta Gap = 0.0020030 m VT = 0.056893005 Vs 17:12:52 Integrated Voltage Measurement... 17:13:13 Voltage Offset Correction: v_off_ini = 0.000001345 V, v_off_fin = 0.000000229 V 17:13:14 Integrated Voltage Measurement Delta Gap = -0.0020033 m VT = -0.056905177 Vs 17:13:24 8` Voltage Measurement, V = 0.000000 V 17:13:24 Temperature Measurement, Probe Number = 0, T = 20.337000 C 17:13:25 Temperature Measurement, Probe Number = 1, T = 21.251000 C 17:13:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 20.34 P2 = Ambient, Value = 21.25 17:13:25 Integrated Voltage Measurement... 17:13:42 Voltage Offset Correction: v_off_ini = -0.000000952 V, v_off_fin = 0.000000731 V 17:13:42 Integrated Voltage Measurement Delta Gap = 0.0020043 m VT = 0.056947685 Vs 17:13:43 Integrated Voltage Measurement... 17:14:04 Voltage Offset Correction: v_off_ini = 0.000001152 V, v_off_fin = -0.000000629 V 17:14:04 Integrated Voltage Measurement Delta Gap = -0.0020039 m VT = -0.056905608 Vs 17:14:14 8` Voltage Measurement, V = 0.000000 V 17:14:15 Temperature Measurement, Probe Number = 0, T = 20.338000 C 17:14:15 Temperature Measurement, Probe Number = 1, T = 21.240000 C 17:14:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Undulator Bottom Jaw, Value = 20.34 P2 = Ambient, Value = 21.24 17:14:15 Integrated Voltage Measurement... 17:14:36 Voltage Offset Correction: v_off_ini = 0.000001901 V, v_off_fin = 0.000002695 V 17:14:36 Integrated Voltage Measurement Delta Gap = 0.0020031 m VT = 0.056886936 Vs 17:14:37 Integrated Voltage Measurement... 17:14:58 Voltage Offset Correction: v_off_ini = 0.000001878 V, v_off_fin = -0.000001150 V 17:14:58 Integrated Voltage Measurement Delta Gap = -0.0020031 m VT = -0.056891616 Vs