SLAC Magnetic Measurements Date: 03-05-2018 Time: 18:42:45 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_Coil_Test Serial Number: 00 Run Number: 4 Measurement Device: PXI4464 Operator: jeb Comment: 1 tape on more parts of the coil 18:42:46 Ambient Measurement Device(s) Being Used, type = None 18:42:46 Magnet Voltage Measurement Device(s) Being Used, type = None 18:42:46 Temperature Measurement Device(s) Being Used, type = None 18:42:46 XMAG Device(s) Being Used, type = None 18:42:46 Ambient Measurement Device(s) Being Used, type = None 18:42:49 Magnet Test Parameter Measurements 18:42:50 Integrated Voltage Measurement... 18:43:10 Voltage Offset Correction: v_off_ini = 0.000005054 V, v_off_fin = 0.000003012 V 18:43:11 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = -0.175224399 Vs 18:43:11 Integrated Voltage Measurement... 18:43:32 Voltage Offset Correction: v_off_ini = -0.000001003 V, v_off_fin = 0.000005699 V 18:43:32 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = 0.175056819 Vs 18:43:34 Magnet Test Parameter Measurements 18:43:34 Integrated Voltage Measurement... 18:43:53 Voltage Offset Correction: v_off_ini = 0.000005702 V, v_off_fin = 0.000004776 V 18:43:54 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.175261230 Vs 18:43:54 Integrated Voltage Measurement... 18:44:13 Voltage Offset Correction: v_off_ini = 0.000005551 V, v_off_fin = 0.000005186 V 18:44:13 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.175054869 Vs 18:44:15 Magnet Test Parameter Measurements 18:44:15 Integrated Voltage Measurement... 18:44:35 Voltage Offset Correction: v_off_ini = 0.000006084 V, v_off_fin = 0.000005670 V 18:44:35 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.175265158 Vs 18:44:35 Integrated Voltage Measurement... 18:44:54 Voltage Offset Correction: v_off_ini = 0.000001076 V, v_off_fin = 0.000006807 V 18:44:54 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = 0.175076142 Vs 18:44:57 Magnet Test Parameter Measurements 18:44:57 Integrated Voltage Measurement... 18:45:16 Voltage Offset Correction: v_off_ini = 0.000005660 V, v_off_fin = 0.000004606 V 18:45:16 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.175261520 Vs 18:45:16 Integrated Voltage Measurement... 18:45:35 Voltage Offset Correction: v_off_ini = -0.000000650 V, v_off_fin = 0.000006828 V 18:45:36 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = 0.175083966 Vs 18:45:38 Magnet Test Parameter Measurements 18:45:38 Integrated Voltage Measurement... 18:45:57 Voltage Offset Correction: v_off_ini = 0.000007338 V, v_off_fin = 0.000001063 V 18:45:57 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.175242216 Vs 18:45:57 Integrated Voltage Measurement... 18:46:16 Voltage Offset Correction: v_off_ini = -0.000000458 V, v_off_fin = 0.000006202 V 18:46:17 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.175097138 Vs 18:46:19 Magnet Test Parameter Measurements 18:46:19 Integrated Voltage Measurement... 18:46:38 Voltage Offset Correction: v_off_ini = 0.000006907 V, v_off_fin = 0.000005495 V 18:46:38 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.175273423 Vs 18:46:38 Integrated Voltage Measurement... 18:46:59 Voltage Offset Correction: v_off_ini = 0.000000332 V, v_off_fin = 0.000008123 V 18:46:59 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = 0.175053847 Vs 18:47:01 Magnet Test Parameter Measurements 18:47:01 Integrated Voltage Measurement... 18:47:21 Voltage Offset Correction: v_off_ini = 0.000002496 V, v_off_fin = 0.000003984 V 18:47:21 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.175226243 Vs 18:47:21 Integrated Voltage Measurement... 18:47:40 Voltage Offset Correction: v_off_ini = 0.000004302 V, v_off_fin = 0.000009203 V 18:47:40 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.175050986 Vs 18:47:42 Magnet Test Parameter Measurements 18:47:42 Integrated Voltage Measurement... 18:48:02 Voltage Offset Correction: v_off_ini = 0.000003110 V, v_off_fin = 0.000002850 V 18:48:02 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.175221679 Vs 18:48:02 Integrated Voltage Measurement... 18:48:21 Voltage Offset Correction: v_off_ini = 0.000004905 V, v_off_fin = 0.000008557 V 18:48:21 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.175043946 Vs 18:48:23 Magnet Test Parameter Measurements 18:48:24 Integrated Voltage Measurement... 18:48:43 Voltage Offset Correction: v_off_ini = 0.000006872 V, v_off_fin = 0.000005030 V 18:48:43 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = -0.175270388 Vs 18:48:43 Integrated Voltage Measurement... 18:49:02 Voltage Offset Correction: v_off_ini = 0.000004760 V, v_off_fin = 0.000004646 V 18:49:02 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = 0.175069971 Vs 18:49:05 Magnet Test Parameter Measurements 18:49:05 Integrated Voltage Measurement... 18:49:24 Voltage Offset Correction: v_off_ini = 0.000005156 V, v_off_fin = 0.000004459 V 18:49:24 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.175252325 Vs 18:49:24 Integrated Voltage Measurement... 18:49:43 Voltage Offset Correction: v_off_ini = 0.000002141 V, v_off_fin = 0.000002405 V 18:49:43 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = 0.175114768 Vs