SLAC Magnetic Measurements Date: 08-27-2019 Time: 09:07:58 Project: LCLS-II Magnet Type: Dipole Magnet Name: 4580 Serial Number: Run Number: 2 Measurement Device: 10wire Operator: sda Comment: BL vs current near 216.88 with trim at +/- 6 amps. Magnet stdz before measurements Standardization for MAIN: 3 cycles from 0.0 A to 300.0 A to 0.0 A Test Currents for MAIN (A): 216.82 216.82 216.82 216.82 216.82 300.00 Test Currents for TRIM (A): 0.00 -6.00 0.00 6.00 -6.00 0.00 09:08:26 Position moved: 0.000000 m 09:08:29 Magnet Current for MAIN, Imag = 0.0067 A Vtrans = 0.000067 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:08:30 Magnet Current for MAIN, Imag = 0.0067 A Vtrans = 0.000067 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:08:30 Magnet Current for MAIN, Imag = 0.0067 A Vtrans = 0.000067 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:08:31 Magnet Current for MAIN, Imag = 0.0068 A Vtrans = 0.000068 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:08:31 Magnet Avgerage Current Measurement for MAIN : Imag = 0.0067 +- 0.0000 A 09:08:31 Initial Zero Current Measurement for MAIN, Imag_zero = 0.00674335 A 09:08:33 Magnet Current for TRIM, Imag = 0.0012 A Vtrans = 0.000102 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:08:33 Magnet Current for TRIM, Imag = 0.0012 A Vtrans = 0.000102 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:08:34 Magnet Current for TRIM, Imag = 0.0012 A Vtrans = 0.000102 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:08:35 Magnet Current for TRIM, Imag = 0.0012 A Vtrans = 0.000102 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:08:35 Magnet Avgerage Current Measurement for TRIM : Imag = 0.0012 +- 0.0000 A 09:09:27 Initial Zero Current Measurement for TRIM, Imag_zero = 0.00122414 A 09:09:27 Ambient Measurement Device(s) Being Used, type = None 09:09:27 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 09:09:27 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 09:09:27 XMAG Device(s) Being Used, type = None 09:09:28 Ambient Measurement Device(s) Being Used, type = HP34970 09:09:28 Magnet system MAIN current ramping to 300.0000 A... 09:10:08 Magnet system MAIN current ramping to 0.0000 A... 09:10:49 Magnet system MAIN current ramping to 300.0000 A... 09:11:29 Magnet system MAIN current ramping to 0.0000 A... 09:12:09 Magnet system MAIN current ramping to 300.0000 A... 09:12:50 Magnet system MAIN current ramping to 0.0000 A... 09:13:33 Position moved: 0.000000 m 09:13:36 Magnet system MAIN current ramping to 216.8200 A... 09:14:08 Magnet system TRIM current ramping to 0.0000 A... 09:14:19 Magnet Current for MAIN, Imag = 216.7857 A Vtrans = 2.167924 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:14:19 Magnet Current for TRIM, Imag = -0.0000 A Vtrans = 0.000099 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:14:20 MAIN (V) Voltage Measurement, V = 4.681312 V 09:14:21 Temperature Measurement, Probe Number = 0, T = 23.614000 C 09:14:21 Temperature Measurement, Probe Number = 1, T = 25.911000 C 09:14:22 Temperature Measurement, Probe Number = 2, T = 23.451000 C 09:14:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334833 V 09:14:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334833 (V, A, ohm, ...), Measured Value = 28.539353 (C, atm, Hz, ...) 09:14:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.307841 V 09:14:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.307841 (V, A, ohm, ...), Measured Value = 28.164457 (C, atm, Hz, ...) 09:14:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.668516 V 09:14:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.668516 (V, A, ohm, ...), Measured Value = 125.138722 (C, atm, Hz, ...) 09:14:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096030 V 09:14:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096030 (V, A, ohm, ...), Measured Value = 7.202265 (C, atm, Hz, ...) 09:14:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 216.79 P1 = TRIM, Value = -0.00 P2 = MAIN (V), Value = 4.68 P3 = Magnet Core, Value = 23.61 P4 = Coil, Value = 25.91 P5 = Ambient Temp (C), Value = 23.45 P6 = Supply Temp(C), Value = 28.54 P7 = Return Temp(C), Value = 28.16 P8 = Supply Pres(psi), Value = 125.14 P9 = Return Pres(psi), Value = 7.20 09:14:25 Magnetic Field Measurement Measuring the magnet strength... 09:14:25 Integrated Voltage Measurement... 09:14:25 Magnet Current for MAIN, Imag = 216.7861 A Vtrans = 2.167928 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:14:26 Magnet Current for TRIM, Imag = 0.0002 A Vtrans = 0.000118 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:14:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021929526 Vs 09:14:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021924581 Vs 09:14:43 Magnet Current for MAIN, Imag = 216.7861 A Vtrans = 2.167928 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:14:44 Magnet Current for TRIM, Imag = 0.0002 A Vtrans = 0.000116 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:14:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021941258 Vs 09:14:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021939259 Vs 09:15:00 Magnet Current for MAIN, Imag = 216.7853 A Vtrans = 2.167921 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:15:01 Magnet Current for TRIM, Imag = 0.0001 A Vtrans = 0.000113 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:15:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021937225 Vs 09:15:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021928485 Vs 09:15:17 Magnet Current for MAIN, Imag = 216.7858 A Vtrans = 2.167926 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:15:17 Magnet Current for TRIM, Imag = 0.0008 A Vtrans = 0.000170 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:15:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021926801 Vs 09:15:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021934578 Vs 09:15:33 Magnet Current for MAIN, Imag = 216.7849 A Vtrans = 2.167917 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:15:34 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000139 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:15:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021937928 Vs 09:15:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021919584 Vs 09:15:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021931922 +- 0.000004596 Vs 09:15:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.021931922 +- 0.000004596 Vs BL = -0.24368803 +- 0.00005107 Tm 09:15:53 Position moved: 0.000000 m 09:15:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.24369 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.24369 0.00005 -0.24369 0.00000 09:15:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.24369 0.00005 SL = -0.2436880 +- 0.0000511 Tm^2/m^n 09:15:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2436880 +- 0.0000511 Tm^2/m^n Remeasure 09:15:54 Magnetic Field Measurement Measuring the magnet strength... 09:15:54 Integrated Voltage Measurement... 09:15:54 Magnet Current for MAIN, Imag = 216.7846 A Vtrans = 2.167913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:15:55 Magnet Current for TRIM, Imag = 0.0005 A Vtrans = 0.000145 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:16:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021917081 Vs 09:16:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021932800 Vs 09:16:12 Magnet Current for MAIN, Imag = 216.7847 A Vtrans = 2.167914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:16:13 Magnet Current for TRIM, Imag = 0.0002 A Vtrans = 0.000119 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:16:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021935079 Vs 09:16:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021918412 Vs 09:16:29 Magnet Current for MAIN, Imag = 216.7843 A Vtrans = 2.167911 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:16:29 Magnet Current for TRIM, Imag = 0.0003 A Vtrans = 0.000128 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:16:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021930736 Vs 09:16:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021935131 Vs 09:16:46 Magnet Current for MAIN, Imag = 216.7837 A Vtrans = 2.167904 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:16:46 Magnet Current for TRIM, Imag = 0.0005 A Vtrans = 0.000141 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:16:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021931445 Vs 09:17:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021930019 Vs 09:17:02 Magnet Current for MAIN, Imag = 216.7835 A Vtrans = 2.167903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:17:03 Magnet Current for TRIM, Imag = 0.0005 A Vtrans = 0.000144 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:17:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021930690 Vs 09:17:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021911773 Vs 09:17:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021927317 +- 0.000004153 Vs 09:17:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.021927317 +- 0.000004153 Vs BL = -0.24363685 +- 0.00004614 Tm 09:17:22 Position moved: 0.000000 m 09:17:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.24364 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.24364 0.00005 -0.24364 0.00000 09:17:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.24364 0.00005 SL = -0.2436369 +- 0.0000461 Tm^2/m^n 09:17:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2436369 +- 0.0000461 Tm^2/m^n 09:17:25 Position moved: 0.000000 m 09:17:25 Magnet system MAIN current ramping to 216.8200 A... 09:17:35 Magnet system TRIM current ramping to -6.0000 A... 09:17:52 Magnet Current for MAIN, Imag = 216.7827 A Vtrans = 2.167894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:17:53 Magnet Current for TRIM, Imag = -6.0045 A Vtrans = -0.500270 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:17:54 MAIN (V) Voltage Measurement, V = 4.690281 V 09:17:54 Temperature Measurement, Probe Number = 0, T = 23.619000 C 09:17:55 Temperature Measurement, Probe Number = 1, T = 25.915000 C 09:17:56 Temperature Measurement, Probe Number = 2, T = 23.419000 C 09:17:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.335241 V 09:17:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335241 (V, A, ohm, ...), Measured Value = 28.545021 (C, atm, Hz, ...) 09:17:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.340163 V 09:17:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340163 (V, A, ohm, ...), Measured Value = 28.613376 (C, atm, Hz, ...) 09:17:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664280 V 09:17:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664280 (V, A, ohm, ...), Measured Value = 124.820985 (C, atm, Hz, ...) 09:17:58 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096713 V 09:17:58 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096713 (V, A, ohm, ...), Measured Value = 7.253460 (C, atm, Hz, ...) 09:17:58 Magnet Test Parameter Measurements P0 = MAIN, Value = 216.78 P1 = TRIM, Value = -6.00 P2 = MAIN (V), Value = 4.69 P3 = Magnet Core, Value = 23.62 P4 = Coil, Value = 25.91 P5 = Ambient Temp (C), Value = 23.42 P6 = Supply Temp(C), Value = 28.55 P7 = Return Temp(C), Value = 28.61 P8 = Supply Pres(psi), Value = 124.82 P9 = Return Pres(psi), Value = 7.25 09:17:58 Magnetic Field Measurement Measuring the magnet strength... 09:17:58 Integrated Voltage Measurement... 09:17:59 Magnet Current for MAIN, Imag = 216.7830 A Vtrans = 2.167898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:18:00 Magnet Current for TRIM, Imag = -6.0045 A Vtrans = -0.500269 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:18:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020981209 Vs 09:18:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020942406 Vs 09:18:17 Magnet Current for MAIN, Imag = 216.7832 A Vtrans = 2.167899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:18:18 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500269 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:18:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020974050 Vs 09:18:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020968112 Vs 09:18:34 Magnet Current for MAIN, Imag = 216.7827 A Vtrans = 2.167894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:18:34 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500268 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:18:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020968847 Vs 09:18:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020959575 Vs 09:18:50 Magnet Current for MAIN, Imag = 216.7828 A Vtrans = 2.167895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:18:51 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500269 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:18:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020944820 Vs 09:19:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020960867 Vs 09:19:07 Magnet Current for MAIN, Imag = 216.7825 A Vtrans = 2.167893 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:19:08 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500268 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:19:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020955079 Vs 09:19:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020966350 Vs 09:19:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020962132 +- 0.000005879 Vs 09:19:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.020962132 +- 0.000005879 Vs BL = -0.23291257 +- 0.00006532 Tm 09:19:27 Position moved: 0.000000 m 09:19:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.23291 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.23291 0.00007 -0.23291 0.00000 09:19:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.23291 0.00007 SL = -0.2329126 +- 0.0000653 Tm^2/m^n 09:19:27 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2329126 +- 0.0000653 Tm^2/m^n Remeasure 09:19:27 Magnetic Field Measurement Measuring the magnet strength... 09:19:27 Integrated Voltage Measurement... 09:19:28 Magnet Current for MAIN, Imag = 216.7823 A Vtrans = 2.167890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:19:28 Magnet Current for TRIM, Imag = -6.0045 A Vtrans = -0.500269 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:19:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020965049 Vs 09:19:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020940503 Vs 09:19:46 Magnet Current for MAIN, Imag = 216.7819 A Vtrans = 2.167886 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:19:46 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500268 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:19:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020966413 Vs 09:20:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020946100 Vs 09:20:02 Magnet Current for MAIN, Imag = 216.7820 A Vtrans = 2.167888 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:20:03 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500268 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:20:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020968164 Vs 09:20:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020967449 Vs 09:20:19 Magnet Current for MAIN, Imag = 216.7814 A Vtrans = 2.167881 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:20:20 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500267 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:20:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020952859 Vs 09:20:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020947742 Vs 09:20:35 Magnet Current for MAIN, Imag = 216.7810 A Vtrans = 2.167877 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:20:36 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500267 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:20:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020950463 Vs 09:20:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020956712 Vs 09:20:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020956145 +- 0.000006133 Vs 09:20:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.020956145 +- 0.000006133 Vs BL = -0.23284606 +- 0.00006814 Tm 09:20:55 Position moved: 0.000000 m 09:20:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.23285 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.23285 0.00007 -0.23285 0.00000 09:20:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.23285 0.00007 SL = -0.2328461 +- 0.0000681 Tm^2/m^n 09:20:55 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2328461 +- 0.0000681 Tm^2/m^n Remeasure 09:20:56 Magnetic Field Measurement Measuring the magnet strength... 09:20:56 Integrated Voltage Measurement... 09:20:56 Magnet Current for MAIN, Imag = 216.7813 A Vtrans = 2.167880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:20:57 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500267 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:21:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020936641 Vs 09:21:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020942221 Vs 09:21:14 Magnet Current for MAIN, Imag = 216.7806 A Vtrans = 2.167874 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:21:15 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500267 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:21:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020959130 Vs 09:21:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020967109 Vs 09:21:31 Magnet Current for MAIN, Imag = 216.7805 A Vtrans = 2.167872 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:21:31 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500267 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:21:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020951185 Vs 09:21:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020961849 Vs 09:21:48 Magnet Current for MAIN, Imag = 216.7806 A Vtrans = 2.167874 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:21:48 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500267 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:21:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020965365 Vs 09:22:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020940396 Vs 09:22:04 Magnet Current for MAIN, Imag = 216.7806 A Vtrans = 2.167874 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:22:05 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500266 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:22:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020962958 Vs 09:22:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020957006 Vs 09:22:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020954386 +- 0.000008223 Vs 09:22:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.020954386 +- 0.000008223 Vs BL = -0.23282651 +- 0.00009136 Tm 09:22:24 Position moved: 0.000000 m 09:22:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.23283 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.23283 0.00009 -0.23283 0.00000 09:22:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.23283 0.00009 SL = -0.2328265 +- 0.0000914 Tm^2/m^n 09:22:24 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2328265 +- 0.0000914 Tm^2/m^n 09:22:27 Position moved: 0.000000 m 09:22:27 Magnet system MAIN current ramping to 216.8200 A... 09:22:38 Magnet system TRIM current ramping to 0.0000 A... 09:22:55 Magnet Current for MAIN, Imag = 216.7802 A Vtrans = 2.167870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:22:55 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000135 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:22:56 MAIN (V) Voltage Measurement, V = 4.691798 V 09:22:57 Temperature Measurement, Probe Number = 0, T = 23.684000 C 09:22:57 Temperature Measurement, Probe Number = 1, T = 25.964000 C 09:22:58 Temperature Measurement, Probe Number = 2, T = 23.447000 C 09:22:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.338231 V 09:22:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338231 (V, A, ohm, ...), Measured Value = 28.586542 (C, atm, Hz, ...) 09:22:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.385214 V 09:22:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.385214 (V, A, ohm, ...), Measured Value = 29.239079 (C, atm, Hz, ...) 09:23:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.674235 V 09:23:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.674235 (V, A, ohm, ...), Measured Value = 125.567610 (C, atm, Hz, ...) 09:23:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097126 V 09:23:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097126 (V, A, ohm, ...), Measured Value = 7.284442 (C, atm, Hz, ...) 09:23:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 216.78 P1 = TRIM, Value = 0.00 P2 = MAIN (V), Value = 4.69 P3 = Magnet Core, Value = 23.68 P4 = Coil, Value = 25.96 P5 = Ambient Temp (C), Value = 23.45 P6 = Supply Temp(C), Value = 28.59 P7 = Return Temp(C), Value = 29.24 P8 = Supply Pres(psi), Value = 125.57 P9 = Return Pres(psi), Value = 7.28 09:23:00 Magnetic Field Measurement Measuring the magnet strength... 09:23:01 Integrated Voltage Measurement... 09:23:01 Magnet Current for MAIN, Imag = 216.7807 A Vtrans = 2.167875 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:23:02 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000134 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:23:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021929207 Vs 09:23:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021927868 Vs 09:23:19 Magnet Current for MAIN, Imag = 216.7800 A Vtrans = 2.167867 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:23:19 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000134 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:23:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021940954 Vs 09:23:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021919204 Vs 09:23:36 Magnet Current for MAIN, Imag = 216.7797 A Vtrans = 2.167865 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:23:36 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000135 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:23:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021928395 Vs 09:23:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021937666 Vs 09:23:52 Magnet Current for MAIN, Imag = 216.7799 A Vtrans = 2.167866 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:23:53 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000133 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:24:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021928751 Vs 09:24:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021936590 Vs 09:24:09 Magnet Current for MAIN, Imag = 216.7790 A Vtrans = 2.167857 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:24:09 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000135 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:24:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021921108 Vs 09:24:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021918899 Vs 09:24:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021928864 +- 0.000004732 Vs 09:24:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.021928864 +- 0.000004732 Vs BL = -0.24365405 +- 0.00005257 Tm 09:24:29 Position moved: 0.000000 m 09:24:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.24365 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.24365 0.00005 -0.24365 0.00000 09:24:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.24365 0.00005 SL = -0.2436540 +- 0.0000526 Tm^2/m^n 09:24:29 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2436540 +- 0.0000526 Tm^2/m^n Remeasure 09:24:29 Magnetic Field Measurement Measuring the magnet strength... 09:24:29 Integrated Voltage Measurement... 09:24:29 Magnet Current for MAIN, Imag = 216.7788 A Vtrans = 2.167856 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:24:30 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000134 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:24:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021965870 Vs 09:24:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021939612 Vs 09:24:47 Magnet Current for MAIN, Imag = 216.7786 A Vtrans = 2.167853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:24:48 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000131 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:24:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021947571 Vs 09:25:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021943650 Vs 09:25:04 Magnet Current for MAIN, Imag = 216.7781 A Vtrans = 2.167848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:25:05 Magnet Current for TRIM, Imag = 0.0005 A Vtrans = 0.000141 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:25:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021942764 Vs 09:25:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021929721 Vs 09:25:21 Magnet Current for MAIN, Imag = 216.7782 A Vtrans = 2.167849 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:25:21 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000131 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:25:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021930026 Vs 09:25:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021922687 Vs 09:25:37 Magnet Current for MAIN, Imag = 216.7778 A Vtrans = 2.167846 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:25:38 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000131 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:25:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021927436 Vs 09:25:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.021935979 Vs 09:25:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.021938532 +- 0.000009509 Vs 09:25:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.021938532 +- 0.000009509 Vs BL = -0.24376146 +- 0.00010565 Tm 09:25:57 Position moved: 0.000000 m 09:25:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.24376 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.24376 0.00011 -0.24376 0.00000 09:25:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.24376 0.00011 SL = -0.2437615 +- 0.0001057 Tm^2/m^n 09:25:57 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2437615 +- 0.0001057 Tm^2/m^n 09:26:00 Position moved: 0.000000 m 09:26:00 Magnet system MAIN current ramping to 216.8200 A... 09:26:11 Magnet system TRIM current ramping to 6.0000 A... 09:26:28 Magnet Current for MAIN, Imag = 216.7777 A Vtrans = 2.167844 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:26:28 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500396 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:26:29 MAIN (V) Voltage Measurement, V = 4.691539 V 09:26:30 Temperature Measurement, Probe Number = 0, T = 23.735000 C 09:26:30 Temperature Measurement, Probe Number = 1, T = 25.998000 C 09:26:31 Temperature Measurement, Probe Number = 2, T = 23.496000 C 09:26:31 Sensor Voltage Measurement, Sensor Number = 0, V = 2.338230 V 09:26:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338230 (V, A, ohm, ...), Measured Value = 28.586525 (C, atm, Hz, ...) 09:26:32 Sensor Voltage Measurement, Sensor Number = 1, V = 2.406171 V 09:26:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.406171 (V, A, ohm, ...), Measured Value = 29.530156 (C, atm, Hz, ...) 09:26:33 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667979 V 09:26:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667979 (V, A, ohm, ...), Measured Value = 125.098395 (C, atm, Hz, ...) 09:26:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096931 V 09:26:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096931 (V, A, ohm, ...), Measured Value = 7.269855 (C, atm, Hz, ...) 09:26:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 216.78 P1 = TRIM, Value = 6.00 P2 = MAIN (V), Value = 4.69 P3 = Magnet Core, Value = 23.73 P4 = Coil, Value = 26.00 P5 = Ambient Temp (C), Value = 23.50 P6 = Supply Temp(C), Value = 28.59 P7 = Return Temp(C), Value = 29.53 P8 = Supply Pres(psi), Value = 125.10 P9 = Return Pres(psi), Value = 7.27 09:26:33 Magnetic Field Measurement Measuring the magnet strength... 09:26:34 Integrated Voltage Measurement... 09:26:34 Magnet Current for MAIN, Imag = 216.7779 A Vtrans = 2.167847 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:26:35 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500397 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:26:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022955335 Vs 09:26:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022916001 Vs 09:26:52 Magnet Current for MAIN, Imag = 216.7774 A Vtrans = 2.167842 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:26:53 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500397 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:27:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022951493 Vs 09:27:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022942276 Vs 09:27:08 Magnet Current for MAIN, Imag = 216.7771 A Vtrans = 2.167838 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:27:09 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500396 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:27:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022930449 Vs 09:27:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022927922 Vs 09:27:25 Magnet Current for MAIN, Imag = 216.7768 A Vtrans = 2.167835 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:27:26 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500397 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:27:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022946455 Vs 09:27:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022947988 Vs 09:27:42 Magnet Current for MAIN, Imag = 216.7772 A Vtrans = 2.167839 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:27:43 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500397 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:27:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022920671 Vs 09:27:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022923230 Vs 09:27:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022936182 +- 0.000009881 Vs 09:27:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.022936182 +- 0.000009881 Vs BL = -0.25484647 +- 0.00010979 Tm 09:28:02 Position moved: 0.000000 m 09:28:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.25485 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.25485 0.00011 -0.25485 0.00000 09:28:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.25485 0.00011 SL = -0.2548465 +- 0.0001098 Tm^2/m^n 09:28:02 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2548465 +- 0.0001098 Tm^2/m^n Remeasure 09:28:02 Magnetic Field Measurement Measuring the magnet strength... 09:28:02 Integrated Voltage Measurement... 09:28:03 Magnet Current for MAIN, Imag = 216.7763 A Vtrans = 2.167830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:28:03 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500396 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:28:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022961544 Vs 09:28:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022933048 Vs 09:28:21 Magnet Current for MAIN, Imag = 216.7764 A Vtrans = 2.167832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:28:21 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500396 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:28:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022947275 Vs 09:28:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022917678 Vs 09:28:37 Magnet Current for MAIN, Imag = 216.7762 A Vtrans = 2.167829 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:28:38 Magnet Current for TRIM, Imag = 6.0036 A Vtrans = 0.500398 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:28:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022932903 Vs 09:28:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022930226 Vs 09:28:54 Magnet Current for MAIN, Imag = 216.7764 A Vtrans = 2.167832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:28:55 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500397 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:29:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022933417 Vs 09:29:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022910828 Vs 09:29:11 Magnet Current for MAIN, Imag = 216.7760 A Vtrans = 2.167828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:29:11 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500397 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:29:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022923461 Vs 09:29:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022942146 Vs 09:29:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022933253 +- 0.000008059 Vs 09:29:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.022933253 +- 0.000008059 Vs BL = -0.25481392 +- 0.00008955 Tm 09:29:31 Position moved: 0.000000 m 09:29:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.25481 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.25481 0.00009 -0.25481 0.00000 09:29:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.25481 0.00009 SL = -0.2548139 +- 0.0000895 Tm^2/m^n 09:29:31 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2548139 +- 0.0000895 Tm^2/m^n Remeasure 09:29:31 Magnetic Field Measurement Measuring the magnet strength... 09:29:31 Integrated Voltage Measurement... 09:29:31 Magnet Current for MAIN, Imag = 216.7757 A Vtrans = 2.167824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:29:32 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500398 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:29:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022916755 Vs 09:29:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022942975 Vs 09:29:49 Magnet Current for MAIN, Imag = 216.7758 A Vtrans = 2.167825 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:29:50 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500397 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:29:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022923853 Vs 09:30:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022931658 Vs 09:30:06 Magnet Current for MAIN, Imag = 216.7755 A Vtrans = 2.167823 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:30:07 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500397 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:30:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022947745 Vs 09:30:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022942913 Vs 09:30:23 Magnet Current for MAIN, Imag = 216.7758 A Vtrans = 2.167825 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:30:23 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500398 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:30:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022949897 Vs 09:30:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022915374 Vs 09:30:39 Magnet Current for MAIN, Imag = 216.7754 A Vtrans = 2.167822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:30:40 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500397 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:30:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022926602 Vs 09:30:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022922485 Vs 09:30:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022932026 +- 0.000007159 Vs 09:30:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.022932026 +- 0.000007159 Vs BL = -0.25480028 +- 0.00007954 Tm 09:30:59 Position moved: 0.000000 m 09:30:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.25480 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.25480 0.00008 -0.25480 0.00000 09:30:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.25480 0.00008 SL = -0.2548003 +- 0.0000795 Tm^2/m^n 09:30:59 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2548003 +- 0.0000795 Tm^2/m^n Remeasure 09:30:59 Magnetic Field Measurement Measuring the magnet strength... 09:30:59 Integrated Voltage Measurement... 09:31:00 Magnet Current for MAIN, Imag = 216.7755 A Vtrans = 2.167823 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:31:00 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500397 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:31:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022940079 Vs 09:31:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022943547 Vs 09:31:17 Magnet Current for MAIN, Imag = 216.7755 A Vtrans = 2.167823 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:31:18 Magnet Current for TRIM, Imag = 6.0036 A Vtrans = 0.500398 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:31:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022928109 Vs 09:31:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022947816 Vs 09:31:34 Magnet Current for MAIN, Imag = 216.7754 A Vtrans = 2.167822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:31:35 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500396 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:31:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022938201 Vs 09:31:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022948146 Vs 09:31:51 Magnet Current for MAIN, Imag = 216.7759 A Vtrans = 2.167827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:31:51 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500398 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:31:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022939124 Vs 09:32:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022936625 Vs 09:32:07 Magnet Current for MAIN, Imag = 216.7752 A Vtrans = 2.167819 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:32:08 Magnet Current for TRIM, Imag = 6.0035 A Vtrans = 0.500398 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:32:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022922067 Vs 09:32:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022941618 Vs 09:32:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022938533 +- 0.000003945 Vs 09:32:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.022938533 +- 0.000003945 Vs BL = -0.25487259 +- 0.00004383 Tm 09:32:27 Position moved: 0.000000 m 09:32:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.25487 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.25487 0.00004 -0.25487 0.00000 09:32:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.25487 0.00004 SL = -0.2548726 +- 0.0000438 Tm^2/m^n 09:32:27 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2548726 +- 0.0000438 Tm^2/m^n 09:32:30 Position moved: 0.000000 m 09:32:30 Magnet system MAIN current ramping to 216.8200 A... 09:32:41 Magnet system TRIM current ramping to -6.0000 A... 09:33:03 Magnet Current for MAIN, Imag = 216.7752 A Vtrans = 2.167819 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:33:04 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500263 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:33:05 MAIN (V) Voltage Measurement, V = 4.692288 V 09:33:06 Temperature Measurement, Probe Number = 0, T = 23.810000 C 09:33:06 Temperature Measurement, Probe Number = 1, T = 26.072000 C 09:33:07 Temperature Measurement, Probe Number = 2, T = 23.620000 C 09:33:07 Sensor Voltage Measurement, Sensor Number = 0, V = 2.339517 V 09:33:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339517 (V, A, ohm, ...), Measured Value = 28.604408 (C, atm, Hz, ...) 09:33:08 Sensor Voltage Measurement, Sensor Number = 1, V = 2.428338 V 09:33:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.428338 (V, A, ohm, ...), Measured Value = 29.838022 (C, atm, Hz, ...) 09:33:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.653347 V 09:33:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653347 (V, A, ohm, ...), Measured Value = 124.001047 (C, atm, Hz, ...) 09:33:09 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097292 V 09:33:09 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097292 (V, A, ohm, ...), Measured Value = 7.296930 (C, atm, Hz, ...) 09:33:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 216.78 P1 = TRIM, Value = -6.00 P2 = MAIN (V), Value = 4.69 P3 = Magnet Core, Value = 23.81 P4 = Coil, Value = 26.07 P5 = Ambient Temp (C), Value = 23.62 P6 = Supply Temp(C), Value = 28.60 P7 = Return Temp(C), Value = 29.84 P8 = Supply Pres(psi), Value = 124.00 P9 = Return Pres(psi), Value = 7.30 09:33:10 Magnetic Field Measurement Measuring the magnet strength... 09:33:10 Integrated Voltage Measurement... 09:33:10 Magnet Current for MAIN, Imag = 216.7758 A Vtrans = 2.167825 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:33:11 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500263 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:33:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020949746 Vs 09:33:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020974735 Vs 09:33:28 Magnet Current for MAIN, Imag = 216.7754 A Vtrans = 2.167822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:33:29 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500262 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:33:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020971646 Vs 09:33:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020971208 Vs 09:33:44 Magnet Current for MAIN, Imag = 216.7748 A Vtrans = 2.167815 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:33:45 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500263 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:33:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020978163 Vs 09:34:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020986391 Vs 09:34:01 Magnet Current for MAIN, Imag = 216.7750 A Vtrans = 2.167818 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:34:02 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500262 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:34:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020972788 Vs 09:34:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020957172 Vs 09:34:18 Magnet Current for MAIN, Imag = 216.7749 A Vtrans = 2.167816 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:34:19 Magnet Current for TRIM, Imag = -6.0044 A Vtrans = -0.500261 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:34:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020971962 Vs 09:34:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020958850 Vs 09:34:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020969266 +- 0.000007164 Vs 09:34:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.020969266 +- 0.000007164 Vs BL = -0.23299185 +- 0.00007960 Tm 09:34:38 Position moved: 0.000000 m 09:34:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.23299 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.23299 0.00008 -0.23299 0.00000 09:34:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.23299 0.00008 SL = -0.2329918 +- 0.0000796 Tm^2/m^n 09:34:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2329918 +- 0.0000796 Tm^2/m^n Remeasure 09:34:38 Magnetic Field Measurement Measuring the magnet strength... 09:34:38 Integrated Voltage Measurement... 09:34:39 Magnet Current for MAIN, Imag = 216.7745 A Vtrans = 2.167813 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:34:39 Magnet Current for TRIM, Imag = -6.0043 A Vtrans = -0.500260 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:34:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020971272 Vs 09:34:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020972541 Vs 09:34:56 Magnet Current for MAIN, Imag = 216.7744 A Vtrans = 2.167811 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:34:57 Magnet Current for TRIM, Imag = -6.0043 A Vtrans = -0.500260 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:35:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020976064 Vs 09:35:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020978674 Vs 09:35:13 Magnet Current for MAIN, Imag = 216.7745 A Vtrans = 2.167813 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:35:14 Magnet Current for TRIM, Imag = -6.0043 A Vtrans = -0.500259 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:35:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020982393 Vs 09:35:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020959168 Vs 09:35:30 Magnet Current for MAIN, Imag = 216.7741 A Vtrans = 2.167809 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:35:31 Magnet Current for TRIM, Imag = -6.0043 A Vtrans = -0.500257 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:35:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020984010 Vs 09:35:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020974343 Vs 09:35:46 Magnet Current for MAIN, Imag = 216.7740 A Vtrans = 2.167807 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:35:47 Magnet Current for TRIM, Imag = -6.0043 A Vtrans = -0.500258 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:35:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020971315 Vs 09:36:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020956330 Vs 09:36:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020972611 +- 0.000005419 Vs 09:36:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.020972611 +- 0.000005419 Vs BL = -0.23302901 +- 0.00006021 Tm 09:36:07 Position moved: 0.000000 m 09:36:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.23303 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.23303 0.00006 -0.23303 0.00000 09:36:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.23303 0.00006 SL = -0.2330290 +- 0.0000602 Tm^2/m^n 09:36:07 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2330290 +- 0.0000602 Tm^2/m^n Remeasure 09:36:07 Magnetic Field Measurement Measuring the magnet strength... 09:36:07 Integrated Voltage Measurement... 09:36:07 Magnet Current for MAIN, Imag = 216.7740 A Vtrans = 2.167807 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:36:08 Magnet Current for TRIM, Imag = -6.0043 A Vtrans = -0.500259 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:36:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020964268 Vs 09:36:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020962351 Vs 09:36:25 Magnet Current for MAIN, Imag = 216.7738 A Vtrans = 2.167805 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:36:26 Magnet Current for TRIM, Imag = -6.0043 A Vtrans = -0.500258 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:36:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020977644 Vs 09:36:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020980703 Vs 09:36:42 Magnet Current for MAIN, Imag = 216.7736 A Vtrans = 2.167804 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:36:43 Magnet Current for TRIM, Imag = -6.0043 A Vtrans = -0.500257 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:36:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020991613 Vs 09:36:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020969961 Vs 09:36:59 Magnet Current for MAIN, Imag = 216.7741 A Vtrans = 2.167809 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:36:59 Magnet Current for TRIM, Imag = -6.0043 A Vtrans = -0.500256 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:37:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020966994 Vs 09:37:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020970656 Vs 09:37:15 Magnet Current for MAIN, Imag = 216.7743 A Vtrans = 2.167810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:37:16 Magnet Current for TRIM, Imag = -6.0043 A Vtrans = -0.500258 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:37:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020967504 Vs 09:37:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020971923 Vs 09:37:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020972362 +- 0.000006616 Vs 09:37:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.020972362 +- 0.000006616 Vs BL = -0.23302624 +- 0.00007351 Tm 09:37:35 Position moved: 0.000000 m 09:37:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.23303 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.23303 0.00007 -0.23303 0.00000 09:37:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.23303 0.00007 SL = -0.2330262 +- 0.0000735 Tm^2/m^n 09:37:35 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2330262 +- 0.0000735 Tm^2/m^n 09:37:38 Position moved: 0.000000 m 09:37:38 Magnet system MAIN current ramping to 300.0000 A... 09:37:57 Magnet system TRIM current ramping to 0.0000 A... 09:38:14 Magnet Current for MAIN, Imag = 300.0056 A Vtrans = 3.000124 V, Factor V/A = 0.010000 V/A, Zero Current = 0.006743 A 09:38:14 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000137 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001224 A 09:38:15 MAIN (V) Voltage Measurement, V = 6.519409 V 09:38:16 Temperature Measurement, Probe Number = 0, T = 23.872000 C 09:38:16 Temperature Measurement, Probe Number = 1, T = 26.121000 C 09:38:17 Temperature Measurement, Probe Number = 2, T = 23.586000 C 09:38:18 Sensor Voltage Measurement, Sensor Number = 0, V = 2.338125 V 09:38:18 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338125 (V, A, ohm, ...), Measured Value = 28.585076 (C, atm, Hz, ...) 09:38:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.438750 V 09:38:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.438750 (V, A, ohm, ...), Measured Value = 29.982643 (C, atm, Hz, ...) 09:38:19 Sensor Voltage Measurement, Sensor Number = 2, V = 2.654937 V 09:38:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.654937 (V, A, ohm, ...), Measured Value = 124.120305 (C, atm, Hz, ...) 09:38:20 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097281 V 09:38:20 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097281 (V, A, ohm, ...), Measured Value = 7.296067 (C, atm, Hz, ...) 09:38:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.01 P1 = TRIM, Value = 0.00 P2 = MAIN (V), Value = 6.52 P3 = Magnet Core, Value = 23.87 P4 = Coil, Value = 26.12 P5 = Ambient Temp (C), Value = 23.59 P6 = Supply Temp(C), Value = 28.59 P7 = Return Temp(C), Value = 29.98 P8 = Supply Pres(psi), Value = 124.12 P9 = Return Pres(psi), Value = 7.30 09:38:22 Position moved: 0.000000 m 09:38:25 Magnet system MAIN current ramping to 0.0000 A... 09:38:56 Magnet system TRIM current ramping to 0.0000 A...