SLAC Magnetic Measurements Date: 08-26-2019 Time: 15:27:51 Project: LCLS-II Magnet Type: Dipole Magnet Name: 4580 Serial Number: Run Number: 1 Measurement Device: 10wire Operator: sda Comment: BL vs current from 0 to 300 amps in 20 A steps, BL vx X at 300. Standardization for MAIN: 7 cycles from 0.0 A to 300.0 A to 0.0 A Test Currents for MAIN (A): 0.00 10.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00 200.00 220.00 240.00 260.00 280.00 300.00 280.00 240.00 200.00 160.00 120.00 80.00 40.00 20.00 10.00 0.00 15:28:18 Position moved: 0.000000 m 15:28:51 Magnet Current for MAIN, Imag = 0.0079 A Vtrans = 0.000079 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:52 Magnet Current for MAIN, Imag = 0.0079 A Vtrans = 0.000079 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:53 Magnet Current for MAIN, Imag = 0.0078 A Vtrans = 0.000078 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:53 Magnet Current for MAIN, Imag = 0.0079 A Vtrans = 0.000079 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:53 Magnet Avgerage Current Measurement for MAIN : Imag = 0.0079 +- 0.0000 A 15:29:22 Initial Zero Current Measurement for MAIN, Imag_zero = 0.00785315 A 15:29:22 Ambient Measurement Device(s) Being Used, type = None 15:29:22 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 15:29:23 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:29:23 XMAG Device(s) Being Used, type = None 15:29:23 Ambient Measurement Device(s) Being Used, type = HP34970 15:29:23 Magnet system MAIN current ramping to 300.0000 A... 15:29:54 Magnet Current for MAIN, Imag = 300.1183 A Vtrans = 3.001261 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:29:55 MAIN (V) Voltage Measurement, V = 6.499053 V 15:29:55 Temperature Measurement, Probe Number = 0, T = 30.687000 C 15:29:56 Temperature Measurement, Probe Number = 1, T = 28.140000 C 15:29:57 Temperature Measurement, Probe Number = 2, T = 29.147000 C 15:29:57 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377575 V 15:29:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377575 (V, A, ohm, ...), Measured Value = 29.132981 (C, atm, Hz, ...) 15:29:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.584897 V 15:29:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.584897 (V, A, ohm, ...), Measured Value = 32.012462 (C, atm, Hz, ...) 15:29:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.666713 V 15:29:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666713 (V, A, ohm, ...), Measured Value = 125.003445 (C, atm, Hz, ...) 15:29:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105107 V 15:29:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105107 (V, A, ohm, ...), Measured Value = 7.883018 (C, atm, Hz, ...) 15:29:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.12 P1 = MAIN (V), Value = 6.50 P2 = Magnet Core, Value = 30.69 P3 = Coil, Value = 28.14 P4 = Ambient Temp (C), Value = 29.15 P5 = Supply Temp(C), Value = 29.13 P6 = Return Temp(C), Value = 32.01 P7 = Supply Pres(psi), Value = 125.00 P8 = Return Pres(psi), Value = 7.88 15:31:00 Magnet Current for MAIN, Imag = 300.1195 A Vtrans = 3.001274 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:31:01 MAIN (V) Voltage Measurement, V = 6.549249 V 15:31:01 Temperature Measurement, Probe Number = 0, T = 30.567000 C 15:31:02 Temperature Measurement, Probe Number = 1, T = 28.144000 C 15:31:03 Temperature Measurement, Probe Number = 2, T = 29.130000 C 15:31:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377713 V 15:31:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377713 (V, A, ohm, ...), Measured Value = 29.134904 (C, atm, Hz, ...) 15:31:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.560076 V 15:31:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.560076 (V, A, ohm, ...), Measured Value = 31.667719 (C, atm, Hz, ...) 15:31:05 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663776 V 15:31:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663776 (V, A, ohm, ...), Measured Value = 124.783230 (C, atm, Hz, ...) 15:31:05 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105207 V 15:31:05 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105207 (V, A, ohm, ...), Measured Value = 7.890548 (C, atm, Hz, ...) 15:31:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.12 P1 = MAIN (V), Value = 6.55 P2 = Magnet Core, Value = 30.57 P3 = Coil, Value = 28.14 P4 = Ambient Temp (C), Value = 29.13 P5 = Supply Temp(C), Value = 29.13 P6 = Return Temp(C), Value = 31.67 P7 = Supply Pres(psi), Value = 124.78 P8 = Return Pres(psi), Value = 7.89 15:32:06 Magnet Current for MAIN, Imag = 300.1204 A Vtrans = 3.001283 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:32:07 MAIN (V) Voltage Measurement, V = 6.553761 V 15:32:07 Temperature Measurement, Probe Number = 0, T = 30.527000 C 15:32:08 Temperature Measurement, Probe Number = 1, T = 28.156000 C 15:32:09 Temperature Measurement, Probe Number = 2, T = 29.147000 C 15:32:09 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377854 V 15:32:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377854 (V, A, ohm, ...), Measured Value = 29.136864 (C, atm, Hz, ...) 15:32:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.554632 V 15:32:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.554632 (V, A, ohm, ...), Measured Value = 31.592108 (C, atm, Hz, ...) 15:32:11 Sensor Voltage Measurement, Sensor Number = 2, V = 2.669377 V 15:32:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669377 (V, A, ohm, ...), Measured Value = 125.203260 (C, atm, Hz, ...) 15:32:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105066 V 15:32:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105066 (V, A, ohm, ...), Measured Value = 7.879973 (C, atm, Hz, ...) 15:32:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.12 P1 = MAIN (V), Value = 6.55 P2 = Magnet Core, Value = 30.53 P3 = Coil, Value = 28.16 P4 = Ambient Temp (C), Value = 29.15 P5 = Supply Temp(C), Value = 29.14 P6 = Return Temp(C), Value = 31.59 P7 = Supply Pres(psi), Value = 125.20 P8 = Return Pres(psi), Value = 7.88 15:33:12 Magnet Current for MAIN, Imag = 300.1213 A Vtrans = 3.001292 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:33:13 MAIN (V) Voltage Measurement, V = 6.554619 V 15:33:13 Temperature Measurement, Probe Number = 0, T = 30.574000 C 15:33:14 Temperature Measurement, Probe Number = 1, T = 28.172000 C 15:33:15 Temperature Measurement, Probe Number = 2, T = 29.134000 C 15:33:15 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377960 V 15:33:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377960 (V, A, ohm, ...), Measured Value = 29.138329 (C, atm, Hz, ...) 15:33:16 Sensor Voltage Measurement, Sensor Number = 1, V = 2.569882 V 15:33:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.569882 (V, A, ohm, ...), Measured Value = 31.803918 (C, atm, Hz, ...) 15:33:17 Sensor Voltage Measurement, Sensor Number = 2, V = 2.671183 V 15:33:17 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.671183 (V, A, ohm, ...), Measured Value = 125.338725 (C, atm, Hz, ...) 15:33:17 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105034 V 15:33:17 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105034 (V, A, ohm, ...), Measured Value = 7.877587 (C, atm, Hz, ...) 15:33:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.12 P1 = MAIN (V), Value = 6.55 P2 = Magnet Core, Value = 30.57 P3 = Coil, Value = 28.17 P4 = Ambient Temp (C), Value = 29.13 P5 = Supply Temp(C), Value = 29.14 P6 = Return Temp(C), Value = 31.80 P7 = Supply Pres(psi), Value = 125.34 P8 = Return Pres(psi), Value = 7.88 15:34:18 Magnet Current for MAIN, Imag = 300.1226 A Vtrans = 3.001304 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:34:19 MAIN (V) Voltage Measurement, V = 6.554956 V 15:34:19 Temperature Measurement, Probe Number = 0, T = 30.658000 C 15:34:20 Temperature Measurement, Probe Number = 1, T = 28.189000 C 15:34:20 Temperature Measurement, Probe Number = 2, T = 29.149000 C 15:34:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378051 V 15:34:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378051 (V, A, ohm, ...), Measured Value = 29.139600 (C, atm, Hz, ...) 15:34:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.592408 V 15:34:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.592408 (V, A, ohm, ...), Measured Value = 32.116779 (C, atm, Hz, ...) 15:34:22 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665346 V 15:34:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665346 (V, A, ohm, ...), Measured Value = 124.900965 (C, atm, Hz, ...) 15:34:23 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105263 V 15:34:23 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105263 (V, A, ohm, ...), Measured Value = 7.894748 (C, atm, Hz, ...) 15:34:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.12 P1 = MAIN (V), Value = 6.55 P2 = Magnet Core, Value = 30.66 P3 = Coil, Value = 28.19 P4 = Ambient Temp (C), Value = 29.15 P5 = Supply Temp(C), Value = 29.14 P6 = Return Temp(C), Value = 32.12 P7 = Supply Pres(psi), Value = 124.90 P8 = Return Pres(psi), Value = 7.89 15:35:24 Magnet Current for MAIN, Imag = 300.1226 A Vtrans = 3.001304 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:35:24 MAIN (V) Voltage Measurement, V = 6.555033 V 15:35:25 Temperature Measurement, Probe Number = 0, T = 30.768000 C 15:35:26 Temperature Measurement, Probe Number = 1, T = 28.208000 C 15:35:26 Temperature Measurement, Probe Number = 2, T = 29.182000 C 15:35:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378102 V 15:35:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378102 (V, A, ohm, ...), Measured Value = 29.140307 (C, atm, Hz, ...) 15:35:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.615237 V 15:35:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.615237 (V, A, ohm, ...), Measured Value = 32.433842 (C, atm, Hz, ...) 15:35:28 Sensor Voltage Measurement, Sensor Number = 2, V = 2.673002 V 15:35:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.673002 (V, A, ohm, ...), Measured Value = 125.475143 (C, atm, Hz, ...) 15:35:29 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105290 V 15:35:29 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105290 (V, A, ohm, ...), Measured Value = 7.896750 (C, atm, Hz, ...) 15:35:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.12 P1 = MAIN (V), Value = 6.56 P2 = Magnet Core, Value = 30.77 P3 = Coil, Value = 28.21 P4 = Ambient Temp (C), Value = 29.18 P5 = Supply Temp(C), Value = 29.14 P6 = Return Temp(C), Value = 32.43 P7 = Supply Pres(psi), Value = 125.48 P8 = Return Pres(psi), Value = 7.90 15:36:30 Magnet Current for MAIN, Imag = 300.1231 A Vtrans = 3.001310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:36:30 MAIN (V) Voltage Measurement, V = 6.555118 V 15:36:31 Temperature Measurement, Probe Number = 0, T = 30.860000 C 15:36:32 Temperature Measurement, Probe Number = 1, T = 28.231000 C 15:36:32 Temperature Measurement, Probe Number = 2, T = 29.212000 C 15:36:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378141 V 15:36:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378141 (V, A, ohm, ...), Measured Value = 29.140854 (C, atm, Hz, ...) 15:36:34 Sensor Voltage Measurement, Sensor Number = 1, V = 2.634637 V 15:36:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.634637 (V, A, ohm, ...), Measured Value = 32.703293 (C, atm, Hz, ...) 15:36:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656362 V 15:36:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656362 (V, A, ohm, ...), Measured Value = 124.227173 (C, atm, Hz, ...) 15:36:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105099 V 15:36:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105099 (V, A, ohm, ...), Measured Value = 7.882448 (C, atm, Hz, ...) 15:36:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.12 P1 = MAIN (V), Value = 6.56 P2 = Magnet Core, Value = 30.86 P3 = Coil, Value = 28.23 P4 = Ambient Temp (C), Value = 29.21 P5 = Supply Temp(C), Value = 29.14 P6 = Return Temp(C), Value = 32.70 P7 = Supply Pres(psi), Value = 124.23 P8 = Return Pres(psi), Value = 7.88 15:37:36 Magnet Current for MAIN, Imag = 300.1239 A Vtrans = 3.001317 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:37:36 MAIN (V) Voltage Measurement, V = 6.555077 V 15:37:37 Temperature Measurement, Probe Number = 0, T = 30.954000 C 15:37:38 Temperature Measurement, Probe Number = 1, T = 28.252000 C 15:37:38 Temperature Measurement, Probe Number = 2, T = 29.184000 C 15:37:39 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378305 V 15:37:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378305 (V, A, ohm, ...), Measured Value = 29.143131 (C, atm, Hz, ...) 15:37:39 Sensor Voltage Measurement, Sensor Number = 1, V = 2.648264 V 15:37:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.648264 (V, A, ohm, ...), Measured Value = 32.892560 (C, atm, Hz, ...) 15:37:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.650907 V 15:37:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.650907 (V, A, ohm, ...), Measured Value = 123.818010 (C, atm, Hz, ...) 15:37:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105460 V 15:37:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105460 (V, A, ohm, ...), Measured Value = 7.909523 (C, atm, Hz, ...) 15:37:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.12 P1 = MAIN (V), Value = 6.56 P2 = Magnet Core, Value = 30.95 P3 = Coil, Value = 28.25 P4 = Ambient Temp (C), Value = 29.18 P5 = Supply Temp(C), Value = 29.14 P6 = Return Temp(C), Value = 32.89 P7 = Supply Pres(psi), Value = 123.82 P8 = Return Pres(psi), Value = 7.91 15:38:42 Magnet Current for MAIN, Imag = 300.1244 A Vtrans = 3.001322 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:38:42 MAIN (V) Voltage Measurement, V = 6.554907 V 15:38:43 Temperature Measurement, Probe Number = 0, T = 31.044000 C 15:38:43 Temperature Measurement, Probe Number = 1, T = 28.271000 C 15:38:44 Temperature Measurement, Probe Number = 2, T = 29.158000 C 15:38:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378430 V 15:38:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378430 (V, A, ohm, ...), Measured Value = 29.144861 (C, atm, Hz, ...) 15:38:45 Sensor Voltage Measurement, Sensor Number = 1, V = 2.659033 V 15:38:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.659033 (V, A, ohm, ...), Measured Value = 33.042122 (C, atm, Hz, ...) 15:38:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655596 V 15:38:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655596 (V, A, ohm, ...), Measured Value = 124.169685 (C, atm, Hz, ...) 15:38:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105338 V 15:38:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105338 (V, A, ohm, ...), Measured Value = 7.900373 (C, atm, Hz, ...) 15:38:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.12 P1 = MAIN (V), Value = 6.55 P2 = Magnet Core, Value = 31.04 P3 = Coil, Value = 28.27 P4 = Ambient Temp (C), Value = 29.16 P5 = Supply Temp(C), Value = 29.14 P6 = Return Temp(C), Value = 33.04 P7 = Supply Pres(psi), Value = 124.17 P8 = Return Pres(psi), Value = 7.90 15:39:48 Magnet Current for MAIN, Imag = 300.1249 A Vtrans = 3.001327 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:39:48 MAIN (V) Voltage Measurement, V = 6.554707 V 15:39:49 Temperature Measurement, Probe Number = 0, T = 31.128000 C 15:39:49 Temperature Measurement, Probe Number = 1, T = 28.289000 C 15:39:50 Temperature Measurement, Probe Number = 2, T = 29.151000 C 15:39:51 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378502 V 15:39:51 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378502 (V, A, ohm, ...), Measured Value = 29.145867 (C, atm, Hz, ...) 15:39:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.668179 V 15:39:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.668179 (V, A, ohm, ...), Measured Value = 33.169158 (C, atm, Hz, ...) 15:39:52 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663175 V 15:39:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663175 (V, A, ohm, ...), Measured Value = 124.738140 (C, atm, Hz, ...) 15:39:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105362 V 15:39:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105362 (V, A, ohm, ...), Measured Value = 7.902180 (C, atm, Hz, ...) 15:39:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.12 P1 = MAIN (V), Value = 6.55 P2 = Magnet Core, Value = 31.13 P3 = Coil, Value = 28.29 P4 = Ambient Temp (C), Value = 29.15 P5 = Supply Temp(C), Value = 29.15 P6 = Return Temp(C), Value = 33.17 P7 = Supply Pres(psi), Value = 124.74 P8 = Return Pres(psi), Value = 7.90 15:40:54 Magnet Current for MAIN, Imag = 300.1253 A Vtrans = 3.001331 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:40:54 MAIN (V) Voltage Measurement, V = 6.554472 V 15:40:55 Temperature Measurement, Probe Number = 0, T = 31.185000 C 15:40:55 Temperature Measurement, Probe Number = 1, T = 28.311000 C 15:40:56 Temperature Measurement, Probe Number = 2, T = 29.145000 C 15:40:57 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378486 V 15:40:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378486 (V, A, ohm, ...), Measured Value = 29.145637 (C, atm, Hz, ...) 15:40:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.676082 V 15:40:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.676082 (V, A, ohm, ...), Measured Value = 33.278912 (C, atm, Hz, ...) 15:40:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661708 V 15:40:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661708 (V, A, ohm, ...), Measured Value = 124.628130 (C, atm, Hz, ...) 15:40:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105500 V 15:40:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105500 (V, A, ohm, ...), Measured Value = 7.912477 (C, atm, Hz, ...) 15:40:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.13 P1 = MAIN (V), Value = 6.55 P2 = Magnet Core, Value = 31.18 P3 = Coil, Value = 28.31 P4 = Ambient Temp (C), Value = 29.14 P5 = Supply Temp(C), Value = 29.15 P6 = Return Temp(C), Value = 33.28 P7 = Supply Pres(psi), Value = 124.63 P8 = Return Pres(psi), Value = 7.91 15:40:59 Magnet system MAIN current ramping to 0.0000 A... 15:41:39 Magnet system MAIN current ramping to 300.0000 A... 15:42:20 Magnet system MAIN current ramping to 0.0000 A... 15:43:00 Magnet system MAIN current ramping to 300.0000 A... 15:43:41 Magnet system MAIN current ramping to 0.0000 A... 15:44:22 Magnet system MAIN current ramping to 300.0000 A... 15:45:02 Magnet system MAIN current ramping to 0.0000 A... 15:45:42 Magnet system MAIN current ramping to 300.0000 A... 15:46:23 Magnet system MAIN current ramping to 0.0000 A... 15:47:03 Magnet system MAIN current ramping to 300.0000 A... 15:47:44 Magnet system MAIN current ramping to 0.0000 A... 15:48:24 Magnet system MAIN current ramping to 300.0000 A... 15:49:04 Magnet system MAIN current ramping to 0.0000 A... 15:49:45 Magnet system MAIN current ramping to 300.0000 A... 15:50:25 Magnet system MAIN current ramping to 0.0000 A... 15:51:09 Position moved: 0.000000 m 15:51:11 Magnet system MAIN current ramping to 0.0000 A... 15:51:22 Magnet Current for MAIN, Imag = 0.0063 A Vtrans = 0.000142 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:51:23 MAIN (V) Voltage Measurement, V = 0.000137 V 15:51:24 Temperature Measurement, Probe Number = 0, T = 30.642000 C 15:51:24 Temperature Measurement, Probe Number = 1, T = 28.441000 C 15:51:25 Temperature Measurement, Probe Number = 2, T = 29.190000 C 15:51:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377057 V 15:51:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377057 (V, A, ohm, ...), Measured Value = 29.125794 (C, atm, Hz, ...) 15:51:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.579409 V 15:51:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.579409 (V, A, ohm, ...), Measured Value = 31.936233 (C, atm, Hz, ...) 15:51:27 Sensor Voltage Measurement, Sensor Number = 2, V = 2.671896 V 15:51:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.671896 (V, A, ohm, ...), Measured Value = 125.392200 (C, atm, Hz, ...) 15:51:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105220 V 15:51:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105220 (V, A, ohm, ...), Measured Value = 7.891507 (C, atm, Hz, ...) 15:51:28 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.01 P1 = MAIN (V), Value = 0.00 P2 = Magnet Core, Value = 30.64 P3 = Coil, Value = 28.44 P4 = Ambient Temp (C), Value = 29.19 P5 = Supply Temp(C), Value = 29.13 P6 = Return Temp(C), Value = 31.94 P7 = Supply Pres(psi), Value = 125.39 P8 = Return Pres(psi), Value = 7.89 15:51:28 Magnetic Field Measurement Measuring the magnet strength... 15:51:28 Integrated Voltage Measurement... 15:51:28 Magnet Current for MAIN, Imag = 0.0063 A Vtrans = 0.000142 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:51:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000138675 Vs 15:51:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000156002 Vs 15:51:46 Magnet Current for MAIN, Imag = 0.0062 A Vtrans = 0.000141 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:51:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000138946 Vs 15:52:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000155535 Vs 15:52:02 Magnet Current for MAIN, Imag = 0.0062 A Vtrans = 0.000140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:52:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000140130 Vs 15:52:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000154148 Vs 15:52:18 Magnet Current for MAIN, Imag = 0.0062 A Vtrans = 0.000140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:52:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000141006 Vs 15:52:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000154205 Vs 15:52:34 Magnet Current for MAIN, Imag = 0.0061 A Vtrans = 0.000140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:52:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000139538 Vs 15:52:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000153899 Vs 15:52:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000147208 +- 0.000000290 Vs 15:52:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.000147208 +- 0.000000290 Vs BL = -0.00163565 +- 0.00000322 Tm 15:52:53 Position moved: 0.000000 m 15:52:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00164 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00164 0.00000 -0.00164 0.00000 15:52:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00164 0.00000 SL = -0.0016356 +- 0.0000032 Tm^2/m^n 15:52:53 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0016356 +- 0.0000032 Tm^2/m^n 15:52:56 Position moved: 0.000000 m 15:52:56 Magnet system MAIN current ramping to 10.0000 A... 15:53:08 Magnet Current for MAIN, Imag = 9.9930 A Vtrans = 0.100008 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:53:09 MAIN (V) Voltage Measurement, V = 0.215480 V 15:53:10 Temperature Measurement, Probe Number = 0, T = 30.539000 C 15:53:10 Temperature Measurement, Probe Number = 1, T = 28.453000 C 15:53:11 Temperature Measurement, Probe Number = 2, T = 29.203000 C 15:53:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376743 V 15:53:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376743 (V, A, ohm, ...), Measured Value = 29.121435 (C, atm, Hz, ...) 15:53:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.566345 V 15:53:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.566345 (V, A, ohm, ...), Measured Value = 31.754788 (C, atm, Hz, ...) 15:53:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657388 V 15:53:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657388 (V, A, ohm, ...), Measured Value = 124.304100 (C, atm, Hz, ...) 15:53:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104919 V 15:53:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104919 (V, A, ohm, ...), Measured Value = 7.868910 (C, atm, Hz, ...) 15:53:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 9.99 P1 = MAIN (V), Value = 0.22 P2 = Magnet Core, Value = 30.54 P3 = Coil, Value = 28.45 P4 = Ambient Temp (C), Value = 29.20 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 31.75 P7 = Supply Pres(psi), Value = 124.30 P8 = Return Pres(psi), Value = 7.87 15:53:14 Magnetic Field Measurement Measuring the magnet strength... 15:53:14 Integrated Voltage Measurement... 15:53:14 Magnet Current for MAIN, Imag = 9.9930 A Vtrans = 0.100008 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:53:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001127222 Vs 15:53:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001141480 Vs 15:53:31 Magnet Current for MAIN, Imag = 9.9929 A Vtrans = 0.100007 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:53:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001125567 Vs 15:53:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001138431 Vs 15:53:48 Magnet Current for MAIN, Imag = 9.9931 A Vtrans = 0.100009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:53:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001127245 Vs 15:54:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001138182 Vs 15:54:03 Magnet Current for MAIN, Imag = 9.9932 A Vtrans = 0.100010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:54:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001127248 Vs 15:54:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001139935 Vs 15:54:19 Magnet Current for MAIN, Imag = 9.9931 A Vtrans = 0.100009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:54:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001126364 Vs 15:54:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001138944 Vs 15:54:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001133062 +- 0.000000820 Vs 15:54:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.001133062 +- 0.000000820 Vs BL = -0.01258957 +- 0.00000911 Tm 15:54:38 Position moved: 0.000000 m 15:54:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01259 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01259 0.00001 -0.01259 0.00000 15:54:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01259 0.00001 SL = -0.0125896 +- 0.0000091 Tm^2/m^n 15:54:39 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0125896 +- 0.0000091 Tm^2/m^n Remeasure 15:54:39 Magnetic Field Measurement Measuring the magnet strength... 15:54:39 Integrated Voltage Measurement... 15:54:39 Magnet Current for MAIN, Imag = 9.9931 A Vtrans = 0.100009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:54:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001128372 Vs 15:54:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001140056 Vs 15:54:56 Magnet Current for MAIN, Imag = 9.9930 A Vtrans = 0.100008 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:55:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001127211 Vs 15:55:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001137988 Vs 15:55:13 Magnet Current for MAIN, Imag = 9.9931 A Vtrans = 0.100009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:55:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001128041 Vs 15:55:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001138879 Vs 15:55:29 Magnet Current for MAIN, Imag = 9.9931 A Vtrans = 0.100010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:55:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001127609 Vs 15:55:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001139920 Vs 15:55:45 Magnet Current for MAIN, Imag = 9.9930 A Vtrans = 0.100008 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:55:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001126180 Vs 15:56:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001139040 Vs 15:56:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001133330 +- 0.000000639 Vs 15:56:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.001133330 +- 0.000000639 Vs BL = -0.01259255 +- 0.00000710 Tm 15:56:04 Position moved: 0.000000 m 15:56:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01259 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01259 0.00001 -0.01259 0.00000 15:56:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01259 0.00001 SL = -0.0125926 +- 0.0000071 Tm^2/m^n 15:56:04 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0125926 +- 0.0000071 Tm^2/m^n Remeasure 15:56:04 Magnetic Field Measurement Measuring the magnet strength... 15:56:04 Integrated Voltage Measurement... 15:56:05 Magnet Current for MAIN, Imag = 9.9928 A Vtrans = 0.100007 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:56:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001126906 Vs 15:56:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001137983 Vs 15:56:22 Magnet Current for MAIN, Imag = 9.9930 A Vtrans = 0.100008 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:56:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001128483 Vs 15:56:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001135993 Vs 15:56:38 Magnet Current for MAIN, Imag = 9.9930 A Vtrans = 0.100008 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:56:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001128555 Vs 15:56:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001136638 Vs 15:56:54 Magnet Current for MAIN, Imag = 9.9929 A Vtrans = 0.100007 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:57:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001128659 Vs 15:57:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001136678 Vs 15:57:10 Magnet Current for MAIN, Imag = 9.9929 A Vtrans = 0.100007 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:57:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001128229 Vs 15:57:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001137488 Vs 15:57:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001132561 +- 0.000000209 Vs 15:57:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.001132561 +- 0.000000209 Vs BL = -0.01258401 +- 0.00000233 Tm 15:57:29 Position moved: 0.000000 m 15:57:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01258 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01258 0.00000 -0.01258 0.00000 15:57:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01258 0.00000 SL = -0.0125840 +- 0.0000023 Tm^2/m^n 15:57:29 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0125840 +- 0.0000023 Tm^2/m^n 15:57:32 Position moved: 0.000000 m 15:57:32 Magnet system MAIN current ramping to 20.0000 A... 15:57:44 Magnet Current for MAIN, Imag = 19.9814 A Vtrans = 0.199893 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:57:45 MAIN (V) Voltage Measurement, V = 0.430792 V 15:57:45 Temperature Measurement, Probe Number = 0, T = 30.158000 C 15:57:46 Temperature Measurement, Probe Number = 1, T = 28.485000 C 15:57:47 Temperature Measurement, Probe Number = 2, T = 29.286000 C 15:57:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376511 V 15:57:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376511 (V, A, ohm, ...), Measured Value = 29.118204 (C, atm, Hz, ...) 15:57:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.504982 V 15:57:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.504982 (V, A, ohm, ...), Measured Value = 30.902529 (C, atm, Hz, ...) 15:57:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665848 V 15:57:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665848 (V, A, ohm, ...), Measured Value = 124.938622 (C, atm, Hz, ...) 15:57:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104981 V 15:57:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104981 (V, A, ohm, ...), Measured Value = 7.873583 (C, atm, Hz, ...) 15:57:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.98 P1 = MAIN (V), Value = 0.43 P2 = Magnet Core, Value = 30.16 P3 = Coil, Value = 28.48 P4 = Ambient Temp (C), Value = 29.29 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 30.90 P7 = Supply Pres(psi), Value = 124.94 P8 = Return Pres(psi), Value = 7.87 15:57:49 Magnetic Field Measurement Measuring the magnet strength... 15:57:49 Integrated Voltage Measurement... 15:57:50 Magnet Current for MAIN, Imag = 19.9815 A Vtrans = 0.199894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:57:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002118684 Vs 15:58:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002131120 Vs 15:58:07 Magnet Current for MAIN, Imag = 19.9814 A Vtrans = 0.199892 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:58:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002113374 Vs 15:58:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002134727 Vs 15:58:23 Magnet Current for MAIN, Imag = 19.9813 A Vtrans = 0.199891 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:58:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002117202 Vs 15:58:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002131535 Vs 15:58:39 Magnet Current for MAIN, Imag = 19.9811 A Vtrans = 0.199890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:58:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002117963 Vs 15:58:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002130707 Vs 15:58:55 Magnet Current for MAIN, Imag = 19.9809 A Vtrans = 0.199888 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:59:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002117501 Vs 15:59:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002131430 Vs 15:59:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002124424 +- 0.000000276 Vs 15:59:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.002124424 +- 0.000000276 Vs BL = -0.02360472 +- 0.00000306 Tm 15:59:14 Position moved: 0.000000 m 15:59:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02360 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02360 0.00000 -0.02360 0.00000 15:59:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02360 0.00000 SL = -0.0236047 +- 0.0000031 Tm^2/m^n 15:59:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0236047 +- 0.0000031 Tm^2/m^n 15:59:17 Position moved: 0.000000 m 15:59:17 Magnet system MAIN current ramping to 40.0000 A... 15:59:30 Magnet Current for MAIN, Imag = 39.9708 A Vtrans = 0.399787 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:59:31 MAIN (V) Voltage Measurement, V = 0.861812 V 15:59:31 Temperature Measurement, Probe Number = 0, T = 30.035000 C 15:59:32 Temperature Measurement, Probe Number = 1, T = 28.495000 C 15:59:33 Temperature Measurement, Probe Number = 2, T = 29.278000 C 15:59:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376694 V 15:59:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376694 (V, A, ohm, ...), Measured Value = 29.120746 (C, atm, Hz, ...) 15:59:34 Sensor Voltage Measurement, Sensor Number = 1, V = 2.488222 V 15:59:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.488222 (V, A, ohm, ...), Measured Value = 30.669746 (C, atm, Hz, ...) 15:59:35 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660372 V 15:59:35 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660372 (V, A, ohm, ...), Measured Value = 124.527937 (C, atm, Hz, ...) 15:59:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104446 V 15:59:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104446 (V, A, ohm, ...), Measured Value = 7.833450 (C, atm, Hz, ...) 15:59:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.97 P1 = MAIN (V), Value = 0.86 P2 = Magnet Core, Value = 30.04 P3 = Coil, Value = 28.50 P4 = Ambient Temp (C), Value = 29.28 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 30.67 P7 = Supply Pres(psi), Value = 124.53 P8 = Return Pres(psi), Value = 7.83 15:59:35 Magnetic Field Measurement Measuring the magnet strength... 15:59:35 Integrated Voltage Measurement... 15:59:36 Magnet Current for MAIN, Imag = 39.9709 A Vtrans = 0.399787 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 15:59:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004109296 Vs 15:59:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.004128903 Vs 15:59:53 Magnet Current for MAIN, Imag = 39.9708 A Vtrans = 0.399787 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:00:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004108911 Vs 16:00:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.004130078 Vs 16:00:09 Magnet Current for MAIN, Imag = 39.9708 A Vtrans = 0.399786 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:00:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004108860 Vs 16:00:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.004130893 Vs 16:00:26 Magnet Current for MAIN, Imag = 39.9709 A Vtrans = 0.399787 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:00:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004110900 Vs 16:00:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.004125818 Vs 16:00:42 Magnet Current for MAIN, Imag = 39.9709 A Vtrans = 0.399788 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:00:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004113207 Vs 16:00:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.004127912 Vs 16:00:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004119478 +- 0.000000738 Vs 16:00:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.004119478 +- 0.000000738 Vs BL = -0.04577197 +- 0.00000820 Tm 16:01:01 Position moved: 0.000000 m 16:01:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04577 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04577 0.00001 -0.04577 0.00000 16:01:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04577 0.00001 SL = -0.0457720 +- 0.0000082 Tm^2/m^n 16:01:01 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0457720 +- 0.0000082 Tm^2/m^n 16:01:04 Position moved: 0.000000 m 16:01:04 Magnet system MAIN current ramping to 60.0000 A... 16:01:17 Magnet Current for MAIN, Imag = 59.9509 A Vtrans = 0.599588 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:01:17 MAIN (V) Voltage Measurement, V = 1.292844 V 16:01:18 Temperature Measurement, Probe Number = 0, T = 29.933000 C 16:01:19 Temperature Measurement, Probe Number = 1, T = 28.503000 C 16:01:19 Temperature Measurement, Probe Number = 2, T = 29.277000 C 16:01:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376720 V 16:01:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376720 (V, A, ohm, ...), Measured Value = 29.121117 (C, atm, Hz, ...) 16:01:21 Sensor Voltage Measurement, Sensor Number = 1, V = 2.475900 V 16:01:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.475900 (V, A, ohm, ...), Measured Value = 30.498610 (C, atm, Hz, ...) 16:01:21 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658609 V 16:01:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658609 (V, A, ohm, ...), Measured Value = 124.395712 (C, atm, Hz, ...) 16:01:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104635 V 16:01:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104635 (V, A, ohm, ...), Measured Value = 7.847655 (C, atm, Hz, ...) 16:01:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 59.95 P1 = MAIN (V), Value = 1.29 P2 = Magnet Core, Value = 29.93 P3 = Coil, Value = 28.50 P4 = Ambient Temp (C), Value = 29.28 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 30.50 P7 = Supply Pres(psi), Value = 124.40 P8 = Return Pres(psi), Value = 7.85 16:01:22 Magnetic Field Measurement Measuring the magnet strength... 16:01:22 Integrated Voltage Measurement... 16:01:23 Magnet Current for MAIN, Imag = 59.9510 A Vtrans = 0.599589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:01:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006119771 Vs 16:01:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006130684 Vs 16:01:40 Magnet Current for MAIN, Imag = 59.9511 A Vtrans = 0.599590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:01:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006109822 Vs 16:01:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006129218 Vs 16:01:56 Magnet Current for MAIN, Imag = 59.9509 A Vtrans = 0.599588 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:02:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006117501 Vs 16:02:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006129869 Vs 16:02:12 Magnet Current for MAIN, Imag = 59.9511 A Vtrans = 0.599589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:02:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006112242 Vs 16:02:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006124357 Vs 16:02:28 Magnet Current for MAIN, Imag = 59.9510 A Vtrans = 0.599589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:02:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006117644 Vs 16:02:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006129179 Vs 16:02:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006122029 +- 0.000002649 Vs 16:02:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.006122029 +- 0.000002649 Vs BL = -0.06802254 +- 0.00002943 Tm 16:02:47 Position moved: 0.000000 m 16:02:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06802 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06802 0.00003 -0.06802 0.00000 16:02:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06802 0.00003 SL = -0.0680225 +- 0.0000294 Tm^2/m^n 16:02:47 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0680225 +- 0.0000294 Tm^2/m^n Remeasure 16:02:47 Magnetic Field Measurement Measuring the magnet strength... 16:02:47 Integrated Voltage Measurement... 16:02:48 Magnet Current for MAIN, Imag = 59.9511 A Vtrans = 0.599590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:02:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006119047 Vs 16:03:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006126352 Vs 16:03:05 Magnet Current for MAIN, Imag = 59.9511 A Vtrans = 0.599590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:03:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006111881 Vs 16:03:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006128772 Vs 16:03:21 Magnet Current for MAIN, Imag = 59.9512 A Vtrans = 0.599590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:03:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006115889 Vs 16:03:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006123406 Vs 16:03:37 Magnet Current for MAIN, Imag = 59.9512 A Vtrans = 0.599590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:03:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006112651 Vs 16:03:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006124857 Vs 16:03:53 Magnet Current for MAIN, Imag = 59.9511 A Vtrans = 0.599590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:04:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006115905 Vs 16:04:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006129254 Vs 16:04:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006120801 +- 0.000001582 Vs 16:04:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.006120801 +- 0.000001582 Vs BL = -0.06800891 +- 0.00001758 Tm 16:04:13 Position moved: 0.000000 m 16:04:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06801 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06801 0.00002 -0.06801 0.00000 16:04:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06801 0.00002 SL = -0.0680089 +- 0.0000176 Tm^2/m^n 16:04:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0680089 +- 0.0000176 Tm^2/m^n Remeasure 16:04:13 Magnetic Field Measurement Measuring the magnet strength... 16:04:13 Integrated Voltage Measurement... 16:04:13 Magnet Current for MAIN, Imag = 59.9512 A Vtrans = 0.599590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:04:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006117751 Vs 16:04:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006132639 Vs 16:04:30 Magnet Current for MAIN, Imag = 59.9510 A Vtrans = 0.599589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:04:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006117426 Vs 16:04:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006128177 Vs 16:04:46 Magnet Current for MAIN, Imag = 59.9511 A Vtrans = 0.599589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:04:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006111971 Vs 16:05:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006123152 Vs 16:05:03 Magnet Current for MAIN, Imag = 59.9510 A Vtrans = 0.599589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:05:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006112803 Vs 16:05:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006127720 Vs 16:05:18 Magnet Current for MAIN, Imag = 59.9511 A Vtrans = 0.599589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:05:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006112957 Vs 16:05:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006122423 Vs 16:05:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006120702 +- 0.000002957 Vs 16:05:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.006120702 +- 0.000002957 Vs BL = -0.06800780 +- 0.00003286 Tm 16:05:38 Position moved: 0.000000 m 16:05:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06801 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06801 0.00003 -0.06801 0.00000 16:05:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06801 0.00003 SL = -0.0680078 +- 0.0000329 Tm^2/m^n 16:05:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0680078 +- 0.0000329 Tm^2/m^n Remeasure 16:05:38 Magnetic Field Measurement Measuring the magnet strength... 16:05:38 Integrated Voltage Measurement... 16:05:39 Magnet Current for MAIN, Imag = 59.9509 A Vtrans = 0.599588 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:05:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006110695 Vs 16:05:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006121714 Vs 16:05:56 Magnet Current for MAIN, Imag = 59.9512 A Vtrans = 0.599590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:06:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006119963 Vs 16:06:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006119965 Vs 16:06:12 Magnet Current for MAIN, Imag = 59.9509 A Vtrans = 0.599587 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:06:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006118400 Vs 16:06:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006125700 Vs 16:06:28 Magnet Current for MAIN, Imag = 59.9511 A Vtrans = 0.599589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:06:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006115264 Vs 16:06:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006125897 Vs 16:06:44 Magnet Current for MAIN, Imag = 59.9510 A Vtrans = 0.599589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:06:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006117317 Vs 16:07:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.006128011 Vs 16:07:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.006120293 +- 0.000002263 Vs 16:07:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.006120293 +- 0.000002263 Vs BL = -0.06800325 +- 0.00002515 Tm 16:07:03 Position moved: 0.000000 m 16:07:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06800 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06800 0.00003 -0.06800 0.00000 16:07:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06800 0.00003 SL = -0.0680033 +- 0.0000251 Tm^2/m^n 16:07:04 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0680033 +- 0.0000251 Tm^2/m^n 16:07:06 Position moved: 0.000000 m 16:07:06 Magnet system MAIN current ramping to 80.0000 A... 16:07:19 Magnet Current for MAIN, Imag = 80.0294 A Vtrans = 0.800372 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:07:20 MAIN (V) Voltage Measurement, V = 1.726339 V 16:07:21 Temperature Measurement, Probe Number = 0, T = 29.785000 C 16:07:21 Temperature Measurement, Probe Number = 1, T = 28.540000 C 16:07:22 Temperature Measurement, Probe Number = 2, T = 29.388000 C 16:07:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376975 V 16:07:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376975 (V, A, ohm, ...), Measured Value = 29.124647 (C, atm, Hz, ...) 16:07:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.456958 V 16:07:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.456958 (V, A, ohm, ...), Measured Value = 30.235533 (C, atm, Hz, ...) 16:07:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662242 V 16:07:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662242 (V, A, ohm, ...), Measured Value = 124.668165 (C, atm, Hz, ...) 16:07:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104400 V 16:07:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104400 (V, A, ohm, ...), Measured Value = 7.830015 (C, atm, Hz, ...) 16:07:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 80.03 P1 = MAIN (V), Value = 1.73 P2 = Magnet Core, Value = 29.79 P3 = Coil, Value = 28.54 P4 = Ambient Temp (C), Value = 29.39 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 30.24 P7 = Supply Pres(psi), Value = 124.67 P8 = Return Pres(psi), Value = 7.83 16:07:25 Magnetic Field Measurement Measuring the magnet strength... 16:07:25 Integrated Voltage Measurement... 16:07:25 Magnet Current for MAIN, Imag = 80.0295 A Vtrans = 0.800374 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:07:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008124967 Vs 16:07:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008147537 Vs 16:07:43 Magnet Current for MAIN, Imag = 80.0294 A Vtrans = 0.800373 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:07:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008131435 Vs 16:07:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008136048 Vs 16:07:59 Magnet Current for MAIN, Imag = 80.0294 A Vtrans = 0.800372 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:08:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008136837 Vs 16:08:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008138169 Vs 16:08:15 Magnet Current for MAIN, Imag = 80.0294 A Vtrans = 0.800372 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:08:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008134449 Vs 16:08:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008136262 Vs 16:08:31 Magnet Current for MAIN, Imag = 80.0295 A Vtrans = 0.800374 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:08:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008130712 Vs 16:08:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008146093 Vs 16:08:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008136251 +- 0.000001631 Vs 16:08:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.008136251 +- 0.000001631 Vs BL = -0.09040279 +- 0.00001812 Tm 16:08:50 Position moved: 0.000000 m 16:08:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.09040 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.09040 0.00002 -0.09040 0.00000 16:08:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.09040 0.00002 SL = -0.0904028 +- 0.0000181 Tm^2/m^n 16:08:50 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0904028 +- 0.0000181 Tm^2/m^n Remeasure 16:08:50 Magnetic Field Measurement Measuring the magnet strength... 16:08:50 Integrated Voltage Measurement... 16:08:51 Magnet Current for MAIN, Imag = 80.0297 A Vtrans = 0.800375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:09:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008132394 Vs 16:09:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008135041 Vs 16:09:08 Magnet Current for MAIN, Imag = 80.0297 A Vtrans = 0.800375 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:09:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008140315 Vs 16:09:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008141500 Vs 16:09:24 Magnet Current for MAIN, Imag = 80.0292 A Vtrans = 0.800371 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:09:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008128654 Vs 16:09:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008142394 Vs 16:09:40 Magnet Current for MAIN, Imag = 80.0293 A Vtrans = 0.800372 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:09:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008129922 Vs 16:09:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008148002 Vs 16:09:57 Magnet Current for MAIN, Imag = 80.0294 A Vtrans = 0.800372 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:10:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008128067 Vs 16:10:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008138279 Vs 16:10:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008136457 +- 0.000003008 Vs 16:10:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.008136457 +- 0.000003008 Vs BL = -0.09040508 +- 0.00003342 Tm 16:10:16 Position moved: 0.000000 m 16:10:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.09041 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.09041 0.00003 -0.09041 0.00000 16:10:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.09041 0.00003 SL = -0.0904051 +- 0.0000334 Tm^2/m^n 16:10:16 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0904051 +- 0.0000334 Tm^2/m^n 16:10:19 Position moved: 0.000000 m 16:10:19 Magnet system MAIN current ramping to 100.0000 A... 16:10:32 Magnet Current for MAIN, Imag = 100.0106 A Vtrans = 1.000185 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:10:33 MAIN (V) Voltage Measurement, V = 2.158238 V 16:10:33 Temperature Measurement, Probe Number = 0, T = 29.751000 C 16:10:34 Temperature Measurement, Probe Number = 1, T = 28.559000 C 16:10:35 Temperature Measurement, Probe Number = 2, T = 29.380000 C 16:10:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376854 V 16:10:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376854 (V, A, ohm, ...), Measured Value = 29.122971 (C, atm, Hz, ...) 16:10:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.453647 V 16:10:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.453647 (V, A, ohm, ...), Measured Value = 30.189544 (C, atm, Hz, ...) 16:10:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.676213 V 16:10:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.676213 (V, A, ohm, ...), Measured Value = 125.715945 (C, atm, Hz, ...) 16:10:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104332 V 16:10:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104332 (V, A, ohm, ...), Measured Value = 7.824870 (C, atm, Hz, ...) 16:10:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 100.01 P1 = MAIN (V), Value = 2.16 P2 = Magnet Core, Value = 29.75 P3 = Coil, Value = 28.56 P4 = Ambient Temp (C), Value = 29.38 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 30.19 P7 = Supply Pres(psi), Value = 125.72 P8 = Return Pres(psi), Value = 7.82 16:10:37 Magnetic Field Measurement Measuring the magnet strength... 16:10:37 Integrated Voltage Measurement... 16:10:38 Magnet Current for MAIN, Imag = 100.0108 A Vtrans = 1.000187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:10:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.010148777 Vs 16:10:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.010146909 Vs 16:10:55 Magnet Current for MAIN, Imag = 100.0109 A Vtrans = 1.000188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:11:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.010135935 Vs 16:11:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.010150955 Vs 16:11:11 Magnet Current for MAIN, Imag = 100.0108 A Vtrans = 1.000187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:11:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.010141059 Vs 16:11:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.010152426 Vs 16:11:27 Magnet Current for MAIN, Imag = 100.0109 A Vtrans = 1.000187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:11:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.010141184 Vs 16:11:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.010155768 Vs 16:11:43 Magnet Current for MAIN, Imag = 100.0109 A Vtrans = 1.000188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:11:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.010143144 Vs 16:11:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.010147169 Vs 16:11:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.010146332 +- 0.000001831 Vs 16:11:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.010146332 +- 0.000001831 Vs BL = -0.11273703 +- 0.00002034 Tm 16:12:03 Position moved: 0.000000 m 16:12:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11274 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11274 0.00002 -0.11274 0.00000 16:12:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11274 0.00002 SL = -0.1127370 +- 0.0000203 Tm^2/m^n 16:12:03 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1127370 +- 0.0000203 Tm^2/m^n 16:12:06 Position moved: 0.000000 m 16:12:06 Magnet system MAIN current ramping to 120.0000 A... 16:12:19 Magnet Current for MAIN, Imag = 120.0025 A Vtrans = 1.200103 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:12:19 MAIN (V) Voltage Measurement, V = 2.590959 V 16:12:20 Temperature Measurement, Probe Number = 0, T = 29.746000 C 16:12:21 Temperature Measurement, Probe Number = 1, T = 28.568000 C 16:12:21 Temperature Measurement, Probe Number = 2, T = 29.337000 C 16:12:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376788 V 16:12:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376788 (V, A, ohm, ...), Measured Value = 29.122053 (C, atm, Hz, ...) 16:12:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.453746 V 16:12:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.453746 (V, A, ohm, ...), Measured Value = 30.190922 (C, atm, Hz, ...) 16:12:23 Sensor Voltage Measurement, Sensor Number = 2, V = 2.669523 V 16:12:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669523 (V, A, ohm, ...), Measured Value = 125.214225 (C, atm, Hz, ...) 16:12:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104488 V 16:12:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104488 (V, A, ohm, ...), Measured Value = 7.836593 (C, atm, Hz, ...) 16:12:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 120.00 P1 = MAIN (V), Value = 2.59 P2 = Magnet Core, Value = 29.75 P3 = Coil, Value = 28.57 P4 = Ambient Temp (C), Value = 29.34 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 30.19 P7 = Supply Pres(psi), Value = 125.21 P8 = Return Pres(psi), Value = 7.84 16:12:24 Magnetic Field Measurement Measuring the magnet strength... 16:12:24 Integrated Voltage Measurement... 16:12:25 Magnet Current for MAIN, Imag = 120.0023 A Vtrans = 1.200102 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:12:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012166689 Vs 16:12:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012155438 Vs 16:12:42 Magnet Current for MAIN, Imag = 120.0026 A Vtrans = 1.200104 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:12:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012161538 Vs 16:12:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012159248 Vs 16:12:58 Magnet Current for MAIN, Imag = 120.0023 A Vtrans = 1.200102 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:13:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012156523 Vs 16:13:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012170575 Vs 16:13:14 Magnet Current for MAIN, Imag = 120.0023 A Vtrans = 1.200102 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:13:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012161335 Vs 16:13:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012172789 Vs 16:13:30 Magnet Current for MAIN, Imag = 120.0025 A Vtrans = 1.200103 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:13:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012166302 Vs 16:13:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012171786 Vs 16:13:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012164222 +- 0.000003359 Vs 16:13:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.012164222 +- 0.000003359 Vs BL = -0.13515803 +- 0.00003732 Tm 16:13:49 Position moved: 0.000000 m 16:13:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.13516 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.13516 0.00004 -0.13516 0.00000 16:13:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.13516 0.00004 SL = -0.1351580 +- 0.0000373 Tm^2/m^n 16:13:49 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1351580 +- 0.0000373 Tm^2/m^n Remeasure 16:13:49 Magnetic Field Measurement Measuring the magnet strength... 16:13:49 Integrated Voltage Measurement... 16:13:50 Magnet Current for MAIN, Imag = 120.0020 A Vtrans = 1.200098 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:13:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012174414 Vs 16:14:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012175300 Vs 16:14:07 Magnet Current for MAIN, Imag = 120.0023 A Vtrans = 1.200102 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:14:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012163177 Vs 16:14:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012173735 Vs 16:14:23 Magnet Current for MAIN, Imag = 120.0020 A Vtrans = 1.200098 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:14:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012159754 Vs 16:14:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012165587 Vs 16:14:40 Magnet Current for MAIN, Imag = 120.0026 A Vtrans = 1.200104 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:14:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012149165 Vs 16:14:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012175807 Vs 16:14:56 Magnet Current for MAIN, Imag = 120.0021 A Vtrans = 1.200099 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:15:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012150075 Vs 16:15:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012174752 Vs 16:15:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012166177 +- 0.000004911 Vs 16:15:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.012166177 +- 0.000004911 Vs BL = -0.13517974 +- 0.00005457 Tm 16:15:15 Position moved: 0.000000 m 16:15:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.13518 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.13518 0.00005 -0.13518 0.00000 16:15:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.13518 0.00005 SL = -0.1351797 +- 0.0000546 Tm^2/m^n 16:15:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1351797 +- 0.0000546 Tm^2/m^n Remeasure 16:15:15 Magnetic Field Measurement Measuring the magnet strength... 16:15:15 Integrated Voltage Measurement... 16:15:16 Magnet Current for MAIN, Imag = 120.0022 A Vtrans = 1.200101 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:15:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012168423 Vs 16:15:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012160813 Vs 16:15:33 Magnet Current for MAIN, Imag = 120.0021 A Vtrans = 1.200099 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:15:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012150803 Vs 16:15:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012170403 Vs 16:15:49 Magnet Current for MAIN, Imag = 120.0026 A Vtrans = 1.200104 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:15:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012146416 Vs 16:16:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012164217 Vs 16:16:05 Magnet Current for MAIN, Imag = 120.0026 A Vtrans = 1.200104 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:16:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012158265 Vs 16:16:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012160406 Vs 16:16:21 Magnet Current for MAIN, Imag = 120.0027 A Vtrans = 1.200106 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:16:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012159369 Vs 16:16:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012173907 Vs 16:16:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012161302 +- 0.000003991 Vs 16:16:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.012161302 +- 0.000003991 Vs BL = -0.13512558 +- 0.00004435 Tm 16:16:41 Position moved: 0.000000 m 16:16:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.13513 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.13513 0.00004 -0.13513 0.00000 16:16:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.13513 0.00004 SL = -0.1351256 +- 0.0000443 Tm^2/m^n 16:16:41 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1351256 +- 0.0000443 Tm^2/m^n 16:16:44 Position moved: 0.000000 m 16:16:44 Magnet system MAIN current ramping to 140.0000 A... 16:16:57 Magnet Current for MAIN, Imag = 140.0541 A Vtrans = 1.400619 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:16:57 MAIN (V) Voltage Measurement, V = 3.025829 V 16:16:58 Temperature Measurement, Probe Number = 0, T = 29.783000 C 16:16:58 Temperature Measurement, Probe Number = 1, T = 28.589000 C 16:16:59 Temperature Measurement, Probe Number = 2, T = 29.280000 C 16:17:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376187 V 16:17:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376187 (V, A, ohm, ...), Measured Value = 29.113703 (C, atm, Hz, ...) 16:17:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.462163 V 16:17:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.462163 (V, A, ohm, ...), Measured Value = 30.307825 (C, atm, Hz, ...) 16:17:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.668835 V 16:17:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.668835 (V, A, ohm, ...), Measured Value = 125.162648 (C, atm, Hz, ...) 16:17:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104300 V 16:17:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104300 (V, A, ohm, ...), Measured Value = 7.822485 (C, atm, Hz, ...) 16:17:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 140.05 P1 = MAIN (V), Value = 3.03 P2 = Magnet Core, Value = 29.78 P3 = Coil, Value = 28.59 P4 = Ambient Temp (C), Value = 29.28 P5 = Supply Temp(C), Value = 29.11 P6 = Return Temp(C), Value = 30.31 P7 = Supply Pres(psi), Value = 125.16 P8 = Return Pres(psi), Value = 7.82 16:17:02 Magnetic Field Measurement Measuring the magnet strength... 16:17:02 Integrated Voltage Measurement... 16:17:03 Magnet Current for MAIN, Imag = 140.0542 A Vtrans = 1.400621 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:17:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014168230 Vs 16:17:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014189306 Vs 16:17:20 Magnet Current for MAIN, Imag = 140.0540 A Vtrans = 1.400618 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:17:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014173547 Vs 16:17:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014189267 Vs 16:17:36 Magnet Current for MAIN, Imag = 140.0543 A Vtrans = 1.400622 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:17:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014173012 Vs 16:17:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014191249 Vs 16:17:52 Magnet Current for MAIN, Imag = 140.0542 A Vtrans = 1.400621 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:18:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014181264 Vs 16:18:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014184030 Vs 16:18:08 Magnet Current for MAIN, Imag = 140.0541 A Vtrans = 1.400619 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:18:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014174050 Vs 16:18:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014177490 Vs 16:18:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014180144 +- 0.000002563 Vs 16:18:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014180144 +- 0.000002563 Vs BL = -0.15755716 +- 0.00002847 Tm 16:18:27 Position moved: 0.000000 m 16:18:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.15756 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.15756 0.00003 -0.15756 0.00000 16:18:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.15756 0.00003 SL = -0.1575572 +- 0.0000285 Tm^2/m^n 16:18:28 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1575572 +- 0.0000285 Tm^2/m^n 16:18:30 Position moved: 0.000000 m 16:18:30 Magnet system MAIN current ramping to 160.0000 A... 16:18:43 Magnet Current for MAIN, Imag = 160.0719 A Vtrans = 1.600797 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:18:44 MAIN (V) Voltage Measurement, V = 3.460846 V 16:18:45 Temperature Measurement, Probe Number = 0, T = 29.810000 C 16:18:45 Temperature Measurement, Probe Number = 1, T = 28.598000 C 16:18:46 Temperature Measurement, Probe Number = 2, T = 29.300000 C 16:18:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.375997 V 16:18:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.375997 (V, A, ohm, ...), Measured Value = 29.111072 (C, atm, Hz, ...) 16:18:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.466104 V 16:18:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.466104 (V, A, ohm, ...), Measured Value = 30.362553 (C, atm, Hz, ...) 16:18:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.668687 V 16:18:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.668687 (V, A, ohm, ...), Measured Value = 125.151495 (C, atm, Hz, ...) 16:18:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104182 V 16:18:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104182 (V, A, ohm, ...), Measured Value = 7.813620 (C, atm, Hz, ...) 16:18:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 160.07 P1 = MAIN (V), Value = 3.46 P2 = Magnet Core, Value = 29.81 P3 = Coil, Value = 28.60 P4 = Ambient Temp (C), Value = 29.30 P5 = Supply Temp(C), Value = 29.11 P6 = Return Temp(C), Value = 30.36 P7 = Supply Pres(psi), Value = 125.15 P8 = Return Pres(psi), Value = 7.81 16:18:49 Magnetic Field Measurement Measuring the magnet strength... 16:18:49 Integrated Voltage Measurement... 16:18:49 Magnet Current for MAIN, Imag = 160.0723 A Vtrans = 1.600801 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:18:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016211384 Vs 16:19:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016202942 Vs 16:19:07 Magnet Current for MAIN, Imag = 160.0723 A Vtrans = 1.600801 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:19:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016197603 Vs 16:19:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016200108 Vs 16:19:23 Magnet Current for MAIN, Imag = 160.0724 A Vtrans = 1.600802 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:19:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016190422 Vs 16:19:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016206851 Vs 16:19:39 Magnet Current for MAIN, Imag = 160.0726 A Vtrans = 1.600805 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:19:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016195159 Vs 16:19:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016219250 Vs 16:19:55 Magnet Current for MAIN, Imag = 160.0723 A Vtrans = 1.600801 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:20:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016210143 Vs 16:20:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016217318 Vs 16:20:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016205118 +- 0.000005726 Vs 16:20:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016205118 +- 0.000005726 Vs BL = -0.18005687 +- 0.00006362 Tm 16:20:14 Position moved: 0.000000 m 16:20:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18006 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18006 0.00006 -0.18006 0.00000 16:20:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18006 0.00006 SL = -0.1800569 +- 0.0000636 Tm^2/m^n 16:20:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1800569 +- 0.0000636 Tm^2/m^n Remeasure 16:20:14 Magnetic Field Measurement Measuring the magnet strength... 16:20:14 Integrated Voltage Measurement... 16:20:15 Magnet Current for MAIN, Imag = 160.0721 A Vtrans = 1.600800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:20:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016185234 Vs 16:20:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016211159 Vs 16:20:32 Magnet Current for MAIN, Imag = 160.0717 A Vtrans = 1.600796 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:20:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016201862 Vs 16:20:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016211065 Vs 16:20:48 Magnet Current for MAIN, Imag = 160.0725 A Vtrans = 1.600804 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:20:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016195387 Vs 16:21:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016211727 Vs 16:21:05 Magnet Current for MAIN, Imag = 160.0723 A Vtrans = 1.600801 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:21:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016199337 Vs 16:21:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016223066 Vs 16:21:20 Magnet Current for MAIN, Imag = 160.0724 A Vtrans = 1.600802 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:21:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016184893 Vs 16:21:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016203437 Vs 16:21:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016202717 +- 0.000006005 Vs 16:21:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016202717 +- 0.000006005 Vs BL = -0.18003019 +- 0.00006672 Tm 16:21:40 Position moved: 0.000000 m 16:21:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18003 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18003 0.00007 -0.18003 0.00000 16:21:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18003 0.00007 SL = -0.1800302 +- 0.0000667 Tm^2/m^n 16:21:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1800302 +- 0.0000667 Tm^2/m^n Remeasure 16:21:40 Magnetic Field Measurement Measuring the magnet strength... 16:21:40 Integrated Voltage Measurement... 16:21:41 Magnet Current for MAIN, Imag = 160.0726 A Vtrans = 1.600805 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:21:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016210353 Vs 16:21:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016206946 Vs 16:21:58 Magnet Current for MAIN, Imag = 160.0728 A Vtrans = 1.600806 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:22:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016207138 Vs 16:22:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016212730 Vs 16:22:14 Magnet Current for MAIN, Imag = 160.0724 A Vtrans = 1.600802 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:22:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016194963 Vs 16:22:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016213440 Vs 16:22:30 Magnet Current for MAIN, Imag = 160.0721 A Vtrans = 1.600800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:22:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016202450 Vs 16:22:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016199853 Vs 16:22:46 Magnet Current for MAIN, Imag = 160.0721 A Vtrans = 1.600800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:22:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016192360 Vs 16:23:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016204758 Vs 16:23:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016204499 +- 0.000004321 Vs 16:23:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016204499 +- 0.000004321 Vs BL = -0.18004999 +- 0.00004801 Tm 16:23:06 Position moved: 0.000000 m 16:23:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18005 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18005 0.00005 -0.18005 0.00000 16:23:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18005 0.00005 SL = -0.1800500 +- 0.0000480 Tm^2/m^n 16:23:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1800500 +- 0.0000480 Tm^2/m^n 16:23:09 Position moved: 0.000000 m 16:23:09 Magnet system MAIN current ramping to 180.0000 A... 16:23:22 Magnet Current for MAIN, Imag = 180.0515 A Vtrans = 1.800594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:23:22 MAIN (V) Voltage Measurement, V = 3.896292 V 16:23:23 Temperature Measurement, Probe Number = 0, T = 29.923000 C 16:23:24 Temperature Measurement, Probe Number = 1, T = 28.630000 C 16:23:24 Temperature Measurement, Probe Number = 2, T = 29.325000 C 16:23:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.375532 V 16:23:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.375532 (V, A, ohm, ...), Measured Value = 29.104610 (C, atm, Hz, ...) 16:23:25 Sensor Voltage Measurement, Sensor Number = 1, V = 2.485114 V 16:23:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.485114 (V, A, ohm, ...), Measured Value = 30.626582 (C, atm, Hz, ...) 16:23:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.649511 V 16:23:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.649511 (V, A, ohm, ...), Measured Value = 123.713340 (C, atm, Hz, ...) 16:23:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104579 V 16:23:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104579 (V, A, ohm, ...), Measured Value = 7.843455 (C, atm, Hz, ...) 16:23:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.05 P1 = MAIN (V), Value = 3.90 P2 = Magnet Core, Value = 29.92 P3 = Coil, Value = 28.63 P4 = Ambient Temp (C), Value = 29.32 P5 = Supply Temp(C), Value = 29.10 P6 = Return Temp(C), Value = 30.63 P7 = Supply Pres(psi), Value = 123.71 P8 = Return Pres(psi), Value = 7.84 16:23:27 Magnetic Field Measurement Measuring the magnet strength... 16:23:27 Integrated Voltage Measurement... 16:23:28 Magnet Current for MAIN, Imag = 180.0522 A Vtrans = 1.800600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:23:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018202915 Vs 16:23:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018239118 Vs 16:23:45 Magnet Current for MAIN, Imag = 180.0520 A Vtrans = 1.800599 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:23:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018226338 Vs 16:24:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018213751 Vs 16:24:01 Magnet Current for MAIN, Imag = 180.0518 A Vtrans = 1.800596 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:24:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018221256 Vs 16:24:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018216779 Vs 16:24:17 Magnet Current for MAIN, Imag = 180.0514 A Vtrans = 1.800593 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:24:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018203976 Vs 16:24:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018233123 Vs 16:24:33 Magnet Current for MAIN, Imag = 180.0519 A Vtrans = 1.800598 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:24:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018207266 Vs 16:24:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018221285 Vs 16:24:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018218581 +- 0.000002315 Vs 16:24:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.018218581 +- 0.000002315 Vs BL = -0.20242867 +- 0.00002572 Tm 16:24:53 Position moved: 0.000000 m 16:24:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.20243 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.20243 0.00003 -0.20243 0.00000 16:24:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.20243 0.00003 SL = -0.2024287 +- 0.0000257 Tm^2/m^n 16:24:53 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2024287 +- 0.0000257 Tm^2/m^n 16:24:56 Position moved: 0.000000 m 16:24:56 Magnet system MAIN current ramping to 200.0000 A... 16:25:09 Magnet Current for MAIN, Imag = 200.1281 A Vtrans = 2.001359 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:25:09 MAIN (V) Voltage Measurement, V = 4.334935 V 16:25:10 Temperature Measurement, Probe Number = 0, T = 29.972000 C 16:25:11 Temperature Measurement, Probe Number = 1, T = 28.643000 C 16:25:11 Temperature Measurement, Probe Number = 2, T = 29.310000 C 16:25:12 Sensor Voltage Measurement, Sensor Number = 0, V = 2.375513 V 16:25:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.375513 (V, A, ohm, ...), Measured Value = 29.104346 (C, atm, Hz, ...) 16:25:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.492339 V 16:25:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.492339 (V, A, ohm, ...), Measured Value = 30.726926 (C, atm, Hz, ...) 16:25:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.645586 V 16:25:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.645586 (V, A, ohm, ...), Measured Value = 123.418958 (C, atm, Hz, ...) 16:25:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104796 V 16:25:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104796 (V, A, ohm, ...), Measured Value = 7.859663 (C, atm, Hz, ...) 16:25:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.13 P1 = MAIN (V), Value = 4.33 P2 = Magnet Core, Value = 29.97 P3 = Coil, Value = 28.64 P4 = Ambient Temp (C), Value = 29.31 P5 = Supply Temp(C), Value = 29.10 P6 = Return Temp(C), Value = 30.73 P7 = Supply Pres(psi), Value = 123.42 P8 = Return Pres(psi), Value = 7.86 16:25:14 Magnetic Field Measurement Measuring the magnet strength... 16:25:14 Integrated Voltage Measurement... 16:25:15 Magnet Current for MAIN, Imag = 200.1283 A Vtrans = 2.001362 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:25:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020261351 Vs 16:25:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020259894 Vs 16:25:32 Magnet Current for MAIN, Imag = 200.1287 A Vtrans = 2.001365 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:25:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020225795 Vs 16:25:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020243559 Vs 16:25:48 Magnet Current for MAIN, Imag = 200.1284 A Vtrans = 2.001363 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:25:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020231982 Vs 16:26:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020260393 Vs 16:26:04 Magnet Current for MAIN, Imag = 200.1283 A Vtrans = 2.001362 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:26:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020232919 Vs 16:26:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020260465 Vs 16:26:20 Magnet Current for MAIN, Imag = 200.1287 A Vtrans = 2.001365 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:26:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020253268 Vs 16:26:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020250713 Vs 16:26:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020248034 +- 0.000008459 Vs 16:26:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.020248034 +- 0.000008459 Vs BL = -0.22497815 +- 0.00009398 Tm 16:26:40 Position moved: 0.000000 m 16:26:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.22498 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.22498 0.00009 -0.22498 0.00000 16:26:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.22498 0.00009 SL = -0.2249782 +- 0.0000940 Tm^2/m^n 16:26:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2249782 +- 0.0000940 Tm^2/m^n Remeasure 16:26:40 Magnetic Field Measurement Measuring the magnet strength... 16:26:40 Integrated Voltage Measurement... 16:26:41 Magnet Current for MAIN, Imag = 200.1282 A Vtrans = 2.001360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:26:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020235158 Vs 16:26:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020256445 Vs 16:26:57 Magnet Current for MAIN, Imag = 200.1286 A Vtrans = 2.001364 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:27:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020235010 Vs 16:27:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020255558 Vs 16:27:14 Magnet Current for MAIN, Imag = 200.1284 A Vtrans = 2.001363 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:27:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020246738 Vs 16:27:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020267076 Vs 16:27:30 Magnet Current for MAIN, Imag = 200.1284 A Vtrans = 2.001363 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:27:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020225844 Vs 16:27:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020265131 Vs 16:27:46 Magnet Current for MAIN, Imag = 200.1287 A Vtrans = 2.001365 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:27:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020255169 Vs 16:28:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020258711 Vs 16:28:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020250084 +- 0.000005587 Vs 16:28:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.020250084 +- 0.000005587 Vs BL = -0.22500093 +- 0.00006208 Tm 16:28:05 Position moved: 0.000000 m 16:28:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.22500 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.22500 0.00006 -0.22500 0.00000 16:28:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.22500 0.00006 SL = -0.2250009 +- 0.0000621 Tm^2/m^n 16:28:05 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2250009 +- 0.0000621 Tm^2/m^n Remeasure 16:28:05 Magnetic Field Measurement Measuring the magnet strength... 16:28:05 Integrated Voltage Measurement... 16:28:06 Magnet Current for MAIN, Imag = 200.1286 A Vtrans = 2.001364 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:28:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020249856 Vs 16:28:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020244654 Vs 16:28:23 Magnet Current for MAIN, Imag = 200.1288 A Vtrans = 2.001367 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:28:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020250549 Vs 16:28:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020237491 Vs 16:28:40 Magnet Current for MAIN, Imag = 200.1288 A Vtrans = 2.001367 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:28:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020240889 Vs 16:28:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020264807 Vs 16:28:56 Magnet Current for MAIN, Imag = 200.1287 A Vtrans = 2.001365 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:29:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020231082 Vs 16:29:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020252982 Vs 16:29:12 Magnet Current for MAIN, Imag = 200.1284 A Vtrans = 2.001363 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:29:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020253217 Vs 16:29:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020268620 Vs 16:29:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020249415 +- 0.000006818 Vs 16:29:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.020249415 +- 0.000006818 Vs BL = -0.22499350 +- 0.00007575 Tm 16:29:31 Position moved: 0.000000 m 16:29:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.22499 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.22499 0.00008 -0.22499 0.00000 16:29:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.22499 0.00008 SL = -0.2249935 +- 0.0000758 Tm^2/m^n 16:29:31 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2249935 +- 0.0000758 Tm^2/m^n 16:29:34 Position moved: 0.000000 m 16:29:34 Magnet system MAIN current ramping to 220.0000 A... 16:29:47 Magnet Current for MAIN, Imag = 220.1102 A Vtrans = 2.201181 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:29:48 MAIN (V) Voltage Measurement, V = 4.773433 V 16:29:48 Temperature Measurement, Probe Number = 0, T = 30.163000 C 16:29:49 Temperature Measurement, Probe Number = 1, T = 28.682000 C 16:29:50 Temperature Measurement, Probe Number = 2, T = 29.367000 C 16:29:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.375790 V 16:29:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.375790 (V, A, ohm, ...), Measured Value = 29.108194 (C, atm, Hz, ...) 16:29:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.521769 V 16:29:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.521769 (V, A, ohm, ...), Measured Value = 31.135688 (C, atm, Hz, ...) 16:29:52 Sensor Voltage Measurement, Sensor Number = 2, V = 2.676683 V 16:29:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.676683 (V, A, ohm, ...), Measured Value = 125.751217 (C, atm, Hz, ...) 16:29:52 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104784 V 16:29:52 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104784 (V, A, ohm, ...), Measured Value = 7.858808 (C, atm, Hz, ...) 16:29:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 220.11 P1 = MAIN (V), Value = 4.77 P2 = Magnet Core, Value = 30.16 P3 = Coil, Value = 28.68 P4 = Ambient Temp (C), Value = 29.37 P5 = Supply Temp(C), Value = 29.11 P6 = Return Temp(C), Value = 31.14 P7 = Supply Pres(psi), Value = 125.75 P8 = Return Pres(psi), Value = 7.86 16:29:53 Magnetic Field Measurement Measuring the magnet strength... 16:29:53 Integrated Voltage Measurement... 16:29:53 Magnet Current for MAIN, Imag = 220.1104 A Vtrans = 2.201182 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:30:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022273197 Vs 16:30:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022249539 Vs 16:30:10 Magnet Current for MAIN, Imag = 220.1106 A Vtrans = 2.201185 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:30:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022264958 Vs 16:30:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022265428 Vs 16:30:26 Magnet Current for MAIN, Imag = 220.1105 A Vtrans = 2.201183 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:30:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022265919 Vs 16:30:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022287311 Vs 16:30:43 Magnet Current for MAIN, Imag = 220.1105 A Vtrans = 2.201183 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:30:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022248547 Vs 16:30:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022281461 Vs 16:30:59 Magnet Current for MAIN, Imag = 220.1107 A Vtrans = 2.201186 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:31:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022253096 Vs 16:31:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022268385 Vs 16:31:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022265784 +- 0.000005713 Vs 16:31:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.022265784 +- 0.000005713 Vs BL = -0.24739760 +- 0.00006348 Tm 16:31:18 Position moved: 0.000000 m 16:31:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.24740 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.24740 0.00006 -0.24740 0.00000 16:31:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.24740 0.00006 SL = -0.2473976 +- 0.0000635 Tm^2/m^n 16:31:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2473976 +- 0.0000635 Tm^2/m^n Remeasure 16:31:19 Magnetic Field Measurement Measuring the magnet strength... 16:31:19 Integrated Voltage Measurement... 16:31:19 Magnet Current for MAIN, Imag = 220.1104 A Vtrans = 2.201182 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:31:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022269590 Vs 16:31:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022251385 Vs 16:31:36 Magnet Current for MAIN, Imag = 220.1106 A Vtrans = 2.201185 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:31:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022277503 Vs 16:31:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022286073 Vs 16:31:53 Magnet Current for MAIN, Imag = 220.1102 A Vtrans = 2.201181 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:32:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022258334 Vs 16:32:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022278873 Vs 16:32:09 Magnet Current for MAIN, Imag = 220.1105 A Vtrans = 2.201183 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:32:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022269951 Vs 16:32:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022259281 Vs 16:32:25 Magnet Current for MAIN, Imag = 220.1106 A Vtrans = 2.201185 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:32:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022262844 Vs 16:32:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022289189 Vs 16:32:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022270302 +- 0.000007696 Vs 16:32:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.022270302 +- 0.000007696 Vs BL = -0.24744780 +- 0.00008551 Tm 16:32:44 Position moved: 0.000000 m 16:32:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.24745 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.24745 0.00009 -0.24745 0.00000 16:32:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.24745 0.00009 SL = -0.2474478 +- 0.0000855 Tm^2/m^n 16:32:44 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2474478 +- 0.0000855 Tm^2/m^n Remeasure 16:32:44 Magnetic Field Measurement Measuring the magnet strength... 16:32:44 Integrated Voltage Measurement... 16:32:45 Magnet Current for MAIN, Imag = 220.1109 A Vtrans = 2.201187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:32:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022254927 Vs 16:33:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022282762 Vs 16:33:02 Magnet Current for MAIN, Imag = 220.1105 A Vtrans = 2.201183 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:33:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022245776 Vs 16:33:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022281522 Vs 16:33:18 Magnet Current for MAIN, Imag = 220.1107 A Vtrans = 2.201186 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:33:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022250116 Vs 16:33:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022279406 Vs 16:33:34 Magnet Current for MAIN, Imag = 220.1102 A Vtrans = 2.201181 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:33:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022253138 Vs 16:33:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022272730 Vs 16:33:51 Magnet Current for MAIN, Imag = 220.1106 A Vtrans = 2.201185 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:33:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022275298 Vs 16:34:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.022260886 Vs 16:34:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.022265656 +- 0.000002381 Vs 16:34:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.022265656 +- 0.000002381 Vs BL = -0.24739618 +- 0.00002645 Tm 16:34:10 Position moved: 0.000000 m 16:34:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.24740 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.24740 0.00003 -0.24740 0.00000 16:34:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.24740 0.00003 SL = -0.2473962 +- 0.0000265 Tm^2/m^n 16:34:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2473962 +- 0.0000265 Tm^2/m^n 16:34:13 Position moved: 0.000000 m 16:34:13 Magnet system MAIN current ramping to 240.0000 A... 16:34:26 Magnet Current for MAIN, Imag = 240.1223 A Vtrans = 2.401302 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:34:26 MAIN (V) Voltage Measurement, V = 5.213987 V 16:34:27 Temperature Measurement, Probe Number = 0, T = 30.377000 C 16:34:28 Temperature Measurement, Probe Number = 1, T = 28.726000 C 16:34:28 Temperature Measurement, Probe Number = 2, T = 29.409000 C 16:34:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376286 V 16:34:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376286 (V, A, ohm, ...), Measured Value = 29.115079 (C, atm, Hz, ...) 16:34:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.551718 V 16:34:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.551718 (V, A, ohm, ...), Measured Value = 31.551646 (C, atm, Hz, ...) 16:34:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.671965 V 16:34:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.671965 (V, A, ohm, ...), Measured Value = 125.397353 (C, atm, Hz, ...) 16:34:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104569 V 16:34:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104569 (V, A, ohm, ...), Measured Value = 7.842698 (C, atm, Hz, ...) 16:34:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 240.12 P1 = MAIN (V), Value = 5.21 P2 = Magnet Core, Value = 30.38 P3 = Coil, Value = 28.73 P4 = Ambient Temp (C), Value = 29.41 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 31.55 P7 = Supply Pres(psi), Value = 125.40 P8 = Return Pres(psi), Value = 7.84 16:34:31 Magnetic Field Measurement Measuring the magnet strength... 16:34:31 Integrated Voltage Measurement... 16:34:32 Magnet Current for MAIN, Imag = 240.1231 A Vtrans = 2.401309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:34:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024303440 Vs 16:34:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024292243 Vs 16:34:49 Magnet Current for MAIN, Imag = 240.1233 A Vtrans = 2.401312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:34:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024282134 Vs 16:35:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024306687 Vs 16:35:05 Magnet Current for MAIN, Imag = 240.1228 A Vtrans = 2.401307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:35:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024295324 Vs 16:35:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024285654 Vs 16:35:21 Magnet Current for MAIN, Imag = 240.1226 A Vtrans = 2.401304 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:35:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024276521 Vs 16:35:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024304957 Vs 16:35:37 Magnet Current for MAIN, Imag = 240.1228 A Vtrans = 2.401307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:35:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024267679 Vs 16:35:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024282443 Vs 16:35:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024289708 +- 0.000007804 Vs 16:35:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.024289708 +- 0.000007804 Vs BL = -0.26988565 +- 0.00008671 Tm 16:35:56 Position moved: 0.000000 m 16:35:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.26989 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.26989 0.00009 -0.26989 0.00000 16:35:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.26989 0.00009 SL = -0.2698856 +- 0.0000867 Tm^2/m^n 16:35:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2698856 +- 0.0000867 Tm^2/m^n Remeasure 16:35:57 Magnetic Field Measurement Measuring the magnet strength... 16:35:57 Integrated Voltage Measurement... 16:35:57 Magnet Current for MAIN, Imag = 240.1228 A Vtrans = 2.401307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:36:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024311831 Vs 16:36:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024285868 Vs 16:36:15 Magnet Current for MAIN, Imag = 240.1228 A Vtrans = 2.401307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:36:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024266068 Vs 16:36:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024291559 Vs 16:36:31 Magnet Current for MAIN, Imag = 240.1229 A Vtrans = 2.401308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:36:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024266018 Vs 16:36:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024303058 Vs 16:36:47 Magnet Current for MAIN, Imag = 240.1226 A Vtrans = 2.401304 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:36:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024268710 Vs 16:37:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024283204 Vs 16:37:03 Magnet Current for MAIN, Imag = 240.1227 A Vtrans = 2.401305 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:37:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024277997 Vs 16:37:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024300169 Vs 16:37:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024285448 +- 0.000008096 Vs 16:37:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.024285448 +- 0.000008096 Vs BL = -0.26983831 +- 0.00008996 Tm 16:37:22 Position moved: 0.000000 m 16:37:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.26984 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.26984 0.00009 -0.26984 0.00000 16:37:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.26984 0.00009 SL = -0.2698383 +- 0.0000900 Tm^2/m^n 16:37:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2698383 +- 0.0000900 Tm^2/m^n Remeasure 16:37:22 Magnetic Field Measurement Measuring the magnet strength... 16:37:22 Integrated Voltage Measurement... 16:37:23 Magnet Current for MAIN, Imag = 240.1231 A Vtrans = 2.401309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:37:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024306830 Vs 16:37:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024272385 Vs 16:37:40 Magnet Current for MAIN, Imag = 240.1227 A Vtrans = 2.401305 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:37:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024290588 Vs 16:37:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024304018 Vs 16:37:56 Magnet Current for MAIN, Imag = 240.1228 A Vtrans = 2.401307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:38:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024300167 Vs 16:38:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024305161 Vs 16:38:13 Magnet Current for MAIN, Imag = 240.1226 A Vtrans = 2.401304 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:38:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024281159 Vs 16:38:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024281330 Vs 16:38:29 Magnet Current for MAIN, Imag = 240.1231 A Vtrans = 2.401309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:38:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024266908 Vs 16:38:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024267707 Vs 16:38:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024287625 +- 0.000012468 Vs 16:38:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.024287625 +- 0.000012468 Vs BL = -0.26986250 +- 0.00013854 Tm 16:38:48 Position moved: 0.000000 m 16:38:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.26986 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.26986 0.00014 -0.26986 0.00000 16:38:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.26986 0.00014 SL = -0.2698625 +- 0.0001385 Tm^2/m^n 16:38:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2698625 +- 0.0001385 Tm^2/m^n Remeasure 16:38:48 Magnetic Field Measurement Measuring the magnet strength... 16:38:48 Integrated Voltage Measurement... 16:38:49 Magnet Current for MAIN, Imag = 240.1232 A Vtrans = 2.401311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:38:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024259784 Vs 16:39:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024298494 Vs 16:39:06 Magnet Current for MAIN, Imag = 240.1233 A Vtrans = 2.401312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:39:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024296023 Vs 16:39:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024277581 Vs 16:39:22 Magnet Current for MAIN, Imag = 240.1229 A Vtrans = 2.401308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:39:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024285571 Vs 16:39:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024306751 Vs 16:39:38 Magnet Current for MAIN, Imag = 240.1232 A Vtrans = 2.401311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:39:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024266328 Vs 16:39:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024292333 Vs 16:39:54 Magnet Current for MAIN, Imag = 240.1232 A Vtrans = 2.401311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:40:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024268755 Vs 16:40:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024297792 Vs 16:40:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024284941 +- 0.000006281 Vs 16:40:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.024284941 +- 0.000006281 Vs BL = -0.26983268 +- 0.00006979 Tm 16:40:14 Position moved: 0.000000 m 16:40:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.26983 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.26983 0.00007 -0.26983 0.00000 16:40:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.26983 0.00007 SL = -0.2698327 +- 0.0000698 Tm^2/m^n 16:40:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2698327 +- 0.0000698 Tm^2/m^n 16:40:17 Position moved: 0.000000 m 16:40:17 Magnet system MAIN current ramping to 260.0000 A... 16:40:30 Magnet Current for MAIN, Imag = 260.1570 A Vtrans = 2.601649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:40:30 MAIN (V) Voltage Measurement, V = 5.656675 V 16:40:31 Temperature Measurement, Probe Number = 0, T = 30.643000 C 16:40:32 Temperature Measurement, Probe Number = 1, T = 28.793000 C 16:40:32 Temperature Measurement, Probe Number = 2, T = 29.452000 C 16:40:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376686 V 16:40:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376686 (V, A, ohm, ...), Measured Value = 29.120640 (C, atm, Hz, ...) 16:40:34 Sensor Voltage Measurement, Sensor Number = 1, V = 2.589230 V 16:40:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.589230 (V, A, ohm, ...), Measured Value = 32.072644 (C, atm, Hz, ...) 16:40:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.670959 V 16:40:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670959 (V, A, ohm, ...), Measured Value = 125.321947 (C, atm, Hz, ...) 16:40:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104953 V 16:40:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104953 (V, A, ohm, ...), Measured Value = 7.871482 (C, atm, Hz, ...) 16:40:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 260.16 P1 = MAIN (V), Value = 5.66 P2 = Magnet Core, Value = 30.64 P3 = Coil, Value = 28.79 P4 = Ambient Temp (C), Value = 29.45 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 32.07 P7 = Supply Pres(psi), Value = 125.32 P8 = Return Pres(psi), Value = 7.87 16:40:35 Magnetic Field Measurement Measuring the magnet strength... 16:40:35 Integrated Voltage Measurement... 16:40:36 Magnet Current for MAIN, Imag = 260.1575 A Vtrans = 2.601654 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:40:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026303867 Vs 16:40:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.026307953 Vs 16:40:53 Magnet Current for MAIN, Imag = 260.1574 A Vtrans = 2.601653 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:41:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026299594 Vs 16:41:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.026311693 Vs 16:41:09 Magnet Current for MAIN, Imag = 260.1570 A Vtrans = 2.601649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:41:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026293572 Vs 16:41:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.026325930 Vs 16:41:25 Magnet Current for MAIN, Imag = 260.1577 A Vtrans = 2.601655 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:41:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026290136 Vs 16:41:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.026315095 Vs 16:41:42 Magnet Current for MAIN, Imag = 260.1573 A Vtrans = 2.601651 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:41:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026313428 Vs 16:41:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.026329023 Vs 16:41:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026309029 +- 0.000006505 Vs 16:41:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.026309029 +- 0.000006505 Vs BL = -0.29232255 +- 0.00007228 Tm 16:42:01 Position moved: 0.000000 m 16:42:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.29232 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.29232 0.00007 -0.29232 0.00000 16:42:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.29232 0.00007 SL = -0.2923225 +- 0.0000723 Tm^2/m^n 16:42:01 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2923225 +- 0.0000723 Tm^2/m^n Remeasure 16:42:01 Magnetic Field Measurement Measuring the magnet strength... 16:42:01 Integrated Voltage Measurement... 16:42:02 Magnet Current for MAIN, Imag = 260.1575 A Vtrans = 2.601654 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:42:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026337397 Vs 16:42:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.026312389 Vs 16:42:19 Magnet Current for MAIN, Imag = 260.1574 A Vtrans = 2.601653 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:42:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026306721 Vs 16:42:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.026298044 Vs 16:42:35 Magnet Current for MAIN, Imag = 260.1570 A Vtrans = 2.601649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:42:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026325518 Vs 16:42:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.026313793 Vs 16:42:51 Magnet Current for MAIN, Imag = 260.1578 A Vtrans = 2.601656 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:42:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026307070 Vs 16:43:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.026309960 Vs 16:43:07 Magnet Current for MAIN, Imag = 260.1577 A Vtrans = 2.601655 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:43:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026298131 Vs 16:43:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.026321068 Vs 16:43:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.026313009 +- 0.000008126 Vs 16:43:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.026313009 +- 0.000008126 Vs BL = -0.29236677 +- 0.00009029 Tm 16:43:27 Position moved: 0.000000 m 16:43:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.29237 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.29237 0.00009 -0.29237 0.00000 16:43:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.29237 0.00009 SL = -0.2923668 +- 0.0000903 Tm^2/m^n 16:43:27 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2923668 +- 0.0000903 Tm^2/m^n 16:43:30 Position moved: 0.000000 m 16:43:30 Magnet system MAIN current ramping to 280.0000 A... 16:43:43 Magnet Current for MAIN, Imag = 280.1499 A Vtrans = 2.801578 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:43:43 MAIN (V) Voltage Measurement, V = 6.099994 V 16:43:44 Temperature Measurement, Probe Number = 0, T = 30.766000 C 16:43:45 Temperature Measurement, Probe Number = 1, T = 28.831000 C 16:43:45 Temperature Measurement, Probe Number = 2, T = 29.495000 C 16:43:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376771 V 16:43:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376771 (V, A, ohm, ...), Measured Value = 29.121822 (C, atm, Hz, ...) 16:43:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.607020 V 16:43:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.607020 (V, A, ohm, ...), Measured Value = 32.319728 (C, atm, Hz, ...) 16:43:47 Sensor Voltage Measurement, Sensor Number = 2, V = 2.689305 V 16:43:47 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.689305 (V, A, ohm, ...), Measured Value = 126.697853 (C, atm, Hz, ...) 16:43:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104366 V 16:43:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104366 (V, A, ohm, ...), Measured Value = 7.827442 (C, atm, Hz, ...) 16:43:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 280.15 P1 = MAIN (V), Value = 6.10 P2 = Magnet Core, Value = 30.77 P3 = Coil, Value = 28.83 P4 = Ambient Temp (C), Value = 29.50 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 32.32 P7 = Supply Pres(psi), Value = 126.70 P8 = Return Pres(psi), Value = 7.83 16:43:48 Magnetic Field Measurement Measuring the magnet strength... 16:43:48 Integrated Voltage Measurement... 16:43:49 Magnet Current for MAIN, Imag = 280.1507 A Vtrans = 2.801585 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:43:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028298410 Vs 16:44:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028317656 Vs 16:44:06 Magnet Current for MAIN, Imag = 280.1511 A Vtrans = 2.801589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:44:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028313267 Vs 16:44:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028329229 Vs 16:44:22 Magnet Current for MAIN, Imag = 280.1511 A Vtrans = 2.801589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:44:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028330997 Vs 16:44:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028342279 Vs 16:44:38 Magnet Current for MAIN, Imag = 280.1504 A Vtrans = 2.801583 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:44:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028342910 Vs 16:44:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028355138 Vs 16:44:54 Magnet Current for MAIN, Imag = 280.1503 A Vtrans = 2.801582 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:45:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028302621 Vs 16:45:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028340804 Vs 16:45:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028327331 +- 0.000014129 Vs 16:45:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.028327331 +- 0.000014129 Vs BL = -0.31474812 +- 0.00015699 Tm 16:45:14 Position moved: 0.000000 m 16:45:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.31475 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.31475 0.00016 -0.31475 0.00000 16:45:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.31475 0.00016 SL = -0.3147481 +- 0.0001570 Tm^2/m^n 16:45:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3147481 +- 0.0001570 Tm^2/m^n Remeasure 16:45:14 Magnetic Field Measurement Measuring the magnet strength... 16:45:14 Integrated Voltage Measurement... 16:45:14 Magnet Current for MAIN, Imag = 280.1508 A Vtrans = 2.801587 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:45:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028317001 Vs 16:45:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028329920 Vs 16:45:32 Magnet Current for MAIN, Imag = 280.1509 A Vtrans = 2.801588 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:45:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028309115 Vs 16:45:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028339495 Vs 16:45:48 Magnet Current for MAIN, Imag = 280.1509 A Vtrans = 2.801588 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:45:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028305144 Vs 16:46:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028345618 Vs 16:46:04 Magnet Current for MAIN, Imag = 280.1508 A Vtrans = 2.801587 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:46:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028322173 Vs 16:46:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028342386 Vs 16:46:20 Magnet Current for MAIN, Imag = 280.1508 A Vtrans = 2.801587 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:46:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028318362 Vs 16:46:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028334317 Vs 16:46:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028326353 +- 0.000003119 Vs 16:46:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.028326353 +- 0.000003119 Vs BL = -0.31473726 +- 0.00003465 Tm 16:46:39 Position moved: 0.000000 m 16:46:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.31474 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.31474 0.00003 -0.31474 0.00000 16:46:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.31474 0.00003 SL = -0.3147373 +- 0.0000347 Tm^2/m^n 16:46:39 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3147373 +- 0.0000347 Tm^2/m^n 16:46:42 Position moved: 0.000000 m 16:46:42 Magnet system MAIN current ramping to 300.0000 A... 16:46:55 Magnet Current for MAIN, Imag = 300.1347 A Vtrans = 3.001425 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:46:56 MAIN (V) Voltage Measurement, V = 6.545001 V 16:46:57 Temperature Measurement, Probe Number = 0, T = 30.915000 C 16:46:57 Temperature Measurement, Probe Number = 1, T = 28.874000 C 16:46:58 Temperature Measurement, Probe Number = 2, T = 29.489000 C 16:46:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376474 V 16:46:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376474 (V, A, ohm, ...), Measured Value = 29.117692 (C, atm, Hz, ...) 16:46:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.630999 V 16:46:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.630999 (V, A, ohm, ...), Measured Value = 32.652768 (C, atm, Hz, ...) 16:47:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.691441 V 16:47:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.691441 (V, A, ohm, ...), Measured Value = 126.858098 (C, atm, Hz, ...) 16:47:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105112 V 16:47:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105112 (V, A, ohm, ...), Measured Value = 7.883400 (C, atm, Hz, ...) 16:47:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.13 P1 = MAIN (V), Value = 6.55 P2 = Magnet Core, Value = 30.91 P3 = Coil, Value = 28.87 P4 = Ambient Temp (C), Value = 29.49 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 32.65 P7 = Supply Pres(psi), Value = 126.86 P8 = Return Pres(psi), Value = 7.88 16:47:01 Magnetic Field Measurement Measuring the magnet strength... 16:47:01 Integrated Voltage Measurement... 16:47:01 Magnet Current for MAIN, Imag = 300.1354 A Vtrans = 3.001433 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:47:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.030358844 Vs 16:47:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.030354680 Vs 16:47:18 Magnet Current for MAIN, Imag = 300.1351 A Vtrans = 3.001429 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:47:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.030349376 Vs 16:47:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.030372138 Vs 16:47:34 Magnet Current for MAIN, Imag = 300.1349 A Vtrans = 3.001428 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:47:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.030324792 Vs 16:47:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.030365126 Vs 16:47:50 Magnet Current for MAIN, Imag = 300.1354 A Vtrans = 3.001433 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:47:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.030321507 Vs 16:48:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.030372155 Vs 16:48:07 Magnet Current for MAIN, Imag = 300.1356 A Vtrans = 3.001434 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:48:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.030339026 Vs 16:48:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.030365771 Vs 16:48:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.030352342 +- 0.000005920 Vs 16:48:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.030352342 +- 0.000005920 Vs BL = -0.33724824 +- 0.00006578 Tm 16:48:26 Position moved: 0.000000 m 16:48:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.33725 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.33725 0.00007 -0.33725 0.00000 16:48:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.33725 0.00007 SL = -0.3372482 +- 0.0000658 Tm^2/m^n 16:48:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3372482 +- 0.0000658 Tm^2/m^n 16:48:29 Position moved: 0.000000 m 16:48:29 Magnet system MAIN current ramping to 280.0000 A... 16:48:42 Magnet Current for MAIN, Imag = 280.1512 A Vtrans = 2.801590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:48:43 MAIN (V) Voltage Measurement, V = 6.112171 V 16:48:43 Temperature Measurement, Probe Number = 0, T = 31.011000 C 16:48:44 Temperature Measurement, Probe Number = 1, T = 28.900000 C 16:48:44 Temperature Measurement, Probe Number = 2, T = 29.489000 C 16:48:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376382 V 16:48:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376382 (V, A, ohm, ...), Measured Value = 29.116421 (C, atm, Hz, ...) 16:48:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.645763 V 16:48:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.645763 (V, A, ohm, ...), Measured Value = 32.857817 (C, atm, Hz, ...) 16:48:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662118 V 16:48:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662118 (V, A, ohm, ...), Measured Value = 124.658828 (C, atm, Hz, ...) 16:48:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105201 V 16:48:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105201 (V, A, ohm, ...), Measured Value = 7.890075 (C, atm, Hz, ...) 16:48:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 280.15 P1 = MAIN (V), Value = 6.11 P2 = Magnet Core, Value = 31.01 P3 = Coil, Value = 28.90 P4 = Ambient Temp (C), Value = 29.49 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 32.86 P7 = Supply Pres(psi), Value = 124.66 P8 = Return Pres(psi), Value = 7.89 16:48:47 Magnetic Field Measurement Measuring the magnet strength... 16:48:47 Integrated Voltage Measurement... 16:48:48 Magnet Current for MAIN, Imag = 280.1516 A Vtrans = 2.801594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:48:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028391210 Vs 16:49:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028404535 Vs 16:49:05 Magnet Current for MAIN, Imag = 280.1516 A Vtrans = 2.801594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:49:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028391659 Vs 16:49:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028405988 Vs 16:49:21 Magnet Current for MAIN, Imag = 280.1516 A Vtrans = 2.801594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:49:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028366216 Vs 16:49:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028366954 Vs 16:49:38 Magnet Current for MAIN, Imag = 280.1511 A Vtrans = 2.801589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:49:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028353993 Vs 16:49:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028401599 Vs 16:49:54 Magnet Current for MAIN, Imag = 280.1516 A Vtrans = 2.801594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:50:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028359092 Vs 16:50:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028399204 Vs 16:50:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028384045 +- 0.000012470 Vs 16:50:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.028384045 +- 0.000012470 Vs BL = -0.31537828 +- 0.00013855 Tm 16:50:13 Position moved: 0.000000 m 16:50:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.31538 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.31538 0.00014 -0.31538 0.00000 16:50:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.31538 0.00014 SL = -0.3153783 +- 0.0001386 Tm^2/m^n 16:50:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3153783 +- 0.0001386 Tm^2/m^n Remeasure 16:50:13 Magnetic Field Measurement Measuring the magnet strength... 16:50:13 Integrated Voltage Measurement... 16:50:14 Magnet Current for MAIN, Imag = 280.1514 A Vtrans = 2.801593 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:50:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028374194 Vs 16:50:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028367217 Vs 16:50:31 Magnet Current for MAIN, Imag = 280.1516 A Vtrans = 2.801594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:50:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028346854 Vs 16:50:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028399378 Vs 16:50:47 Magnet Current for MAIN, Imag = 280.1514 A Vtrans = 2.801593 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:50:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028352226 Vs 16:51:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028371682 Vs 16:51:03 Magnet Current for MAIN, Imag = 280.1513 A Vtrans = 2.801592 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:51:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028379200 Vs 16:51:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028399442 Vs 16:51:20 Magnet Current for MAIN, Imag = 280.1514 A Vtrans = 2.801593 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:51:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028354302 Vs 16:51:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028384203 Vs 16:51:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028372870 +- 0.000009029 Vs 16:51:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.028372870 +- 0.000009029 Vs BL = -0.31525411 +- 0.00010032 Tm 16:51:39 Position moved: 0.000000 m 16:51:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.31525 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.31525 0.00010 -0.31525 0.00000 16:51:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.31525 0.00010 SL = -0.3152541 +- 0.0001003 Tm^2/m^n 16:51:39 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3152541 +- 0.0001003 Tm^2/m^n Remeasure 16:51:39 Magnetic Field Measurement Measuring the magnet strength... 16:51:39 Integrated Voltage Measurement... 16:51:40 Magnet Current for MAIN, Imag = 280.1512 A Vtrans = 2.801590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:51:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028393760 Vs 16:51:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028372753 Vs 16:51:57 Magnet Current for MAIN, Imag = 280.1514 A Vtrans = 2.801593 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:52:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028351020 Vs 16:52:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028376448 Vs 16:52:13 Magnet Current for MAIN, Imag = 280.1513 A Vtrans = 2.801592 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:52:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028387038 Vs 16:52:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028385410 Vs 16:52:30 Magnet Current for MAIN, Imag = 280.1518 A Vtrans = 2.801597 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:52:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028360994 Vs 16:52:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028382684 Vs 16:52:46 Magnet Current for MAIN, Imag = 280.1517 A Vtrans = 2.801595 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:52:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028384467 Vs 16:53:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028393201 Vs 16:53:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028378777 +- 0.000009498 Vs 16:53:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.028378777 +- 0.000009498 Vs BL = -0.31531975 +- 0.00010554 Tm 16:53:05 Position moved: 0.000000 m 16:53:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.31532 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.31532 0.00011 -0.31532 0.00000 16:53:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.31532 0.00011 SL = -0.3153197 +- 0.0001055 Tm^2/m^n 16:53:05 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3153197 +- 0.0001055 Tm^2/m^n Remeasure 16:53:05 Magnetic Field Measurement Measuring the magnet strength... 16:53:05 Integrated Voltage Measurement... 16:53:06 Magnet Current for MAIN, Imag = 280.1518 A Vtrans = 2.801597 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:53:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028339297 Vs 16:53:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028369501 Vs 16:53:23 Magnet Current for MAIN, Imag = 280.1522 A Vtrans = 2.801601 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:53:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028378993 Vs 16:53:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028397722 Vs 16:53:39 Magnet Current for MAIN, Imag = 280.1520 A Vtrans = 2.801598 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:53:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028360732 Vs 16:53:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028357835 Vs 16:53:55 Magnet Current for MAIN, Imag = 280.1523 A Vtrans = 2.801602 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:54:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028351432 Vs 16:54:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028372394 Vs 16:54:11 Magnet Current for MAIN, Imag = 280.1521 A Vtrans = 2.801599 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:54:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028369193 Vs 16:54:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028389838 Vs 16:54:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028368694 +- 0.000012982 Vs 16:54:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.028368694 +- 0.000012982 Vs BL = -0.31520771 +- 0.00014424 Tm 16:54:30 Position moved: 0.000000 m 16:54:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.31521 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.31521 0.00014 -0.31521 0.00000 16:54:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.31521 0.00014 SL = -0.3152077 +- 0.0001442 Tm^2/m^n 16:54:31 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3152077 +- 0.0001442 Tm^2/m^n 16:54:33 Position moved: 0.000000 m 16:54:33 Magnet system MAIN current ramping to 240.0000 A... 16:54:48 Magnet Current for MAIN, Imag = 240.1246 A Vtrans = 2.401325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:54:49 MAIN (V) Voltage Measurement, V = 5.228188 V 16:54:50 Temperature Measurement, Probe Number = 0, T = 31.240000 C 16:54:50 Temperature Measurement, Probe Number = 1, T = 28.986000 C 16:54:51 Temperature Measurement, Probe Number = 2, T = 29.525000 C 16:54:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376400 V 16:54:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376400 (V, A, ohm, ...), Measured Value = 29.116668 (C, atm, Hz, ...) 16:54:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.675365 V 16:54:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.675365 (V, A, ohm, ...), Measured Value = 33.268956 (C, atm, Hz, ...) 16:54:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660516 V 16:54:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660516 (V, A, ohm, ...), Measured Value = 124.538708 (C, atm, Hz, ...) 16:54:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105335 V 16:54:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105335 (V, A, ohm, ...), Measured Value = 7.900088 (C, atm, Hz, ...) 16:54:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 240.12 P1 = MAIN (V), Value = 5.23 P2 = Magnet Core, Value = 31.24 P3 = Coil, Value = 28.99 P4 = Ambient Temp (C), Value = 29.52 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 33.27 P7 = Supply Pres(psi), Value = 124.54 P8 = Return Pres(psi), Value = 7.90 16:54:54 Magnetic Field Measurement Measuring the magnet strength... 16:54:54 Integrated Voltage Measurement... 16:54:54 Magnet Current for MAIN, Imag = 240.1254 A Vtrans = 2.401332 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:55:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024388204 Vs 16:55:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024396069 Vs 16:55:11 Magnet Current for MAIN, Imag = 240.1246 A Vtrans = 2.401325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:55:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024375069 Vs 16:55:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024372414 Vs 16:55:28 Magnet Current for MAIN, Imag = 240.1254 A Vtrans = 2.401332 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:55:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024385728 Vs 16:55:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024409730 Vs 16:55:44 Magnet Current for MAIN, Imag = 240.1250 A Vtrans = 2.401328 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:55:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024378922 Vs 16:55:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024374488 Vs 16:56:00 Magnet Current for MAIN, Imag = 240.1250 A Vtrans = 2.401328 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:56:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024368199 Vs 16:56:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024368967 Vs 16:56:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024381779 +- 0.000011191 Vs 16:56:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.024381779 +- 0.000011191 Vs BL = -0.27090865 +- 0.00012434 Tm 16:56:19 Position moved: 0.000000 m 16:56:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.27091 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.27091 0.00012 -0.27091 0.00000 16:56:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.27091 0.00012 SL = -0.2709087 +- 0.0001243 Tm^2/m^n 16:56:19 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2709087 +- 0.0001243 Tm^2/m^n Remeasure 16:56:19 Magnetic Field Measurement Measuring the magnet strength... 16:56:19 Integrated Voltage Measurement... 16:56:20 Magnet Current for MAIN, Imag = 240.1246 A Vtrans = 2.401325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:56:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024398586 Vs 16:56:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024400384 Vs 16:56:37 Magnet Current for MAIN, Imag = 240.1247 A Vtrans = 2.401326 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:56:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024359087 Vs 16:56:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024375251 Vs 16:56:53 Magnet Current for MAIN, Imag = 240.1243 A Vtrans = 2.401322 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:57:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024379208 Vs 16:57:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024379033 Vs 16:57:09 Magnet Current for MAIN, Imag = 240.1245 A Vtrans = 2.401323 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:57:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024377236 Vs 16:57:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024402233 Vs 16:57:25 Magnet Current for MAIN, Imag = 240.1247 A Vtrans = 2.401326 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:57:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024365230 Vs 16:57:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024405484 Vs 16:57:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024384173 +- 0.000010784 Vs 16:57:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.024384173 +- 0.000010784 Vs BL = -0.27093526 +- 0.00011982 Tm 16:57:45 Position moved: 0.000000 m 16:57:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.27094 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.27094 0.00012 -0.27094 0.00000 16:57:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.27094 0.00012 SL = -0.2709353 +- 0.0001198 Tm^2/m^n 16:57:45 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2709353 +- 0.0001198 Tm^2/m^n Remeasure 16:57:45 Magnetic Field Measurement Measuring the magnet strength... 16:57:45 Integrated Voltage Measurement... 16:57:46 Magnet Current for MAIN, Imag = 240.1246 A Vtrans = 2.401325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:57:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024396171 Vs 16:58:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024391136 Vs 16:58:03 Magnet Current for MAIN, Imag = 240.1246 A Vtrans = 2.401325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:58:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024361014 Vs 16:58:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024400607 Vs 16:58:19 Magnet Current for MAIN, Imag = 240.1246 A Vtrans = 2.401325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:58:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024358529 Vs 16:58:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024378334 Vs 16:58:35 Magnet Current for MAIN, Imag = 240.1245 A Vtrans = 2.401323 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:58:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024364081 Vs 16:58:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024399803 Vs 16:58:51 Magnet Current for MAIN, Imag = 240.1251 A Vtrans = 2.401330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:58:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024389144 Vs 16:59:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024397813 Vs 16:59:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024383663 +- 0.000009373 Vs 16:59:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.024383663 +- 0.000009373 Vs BL = -0.27092959 +- 0.00010414 Tm 16:59:11 Position moved: 0.000000 m 16:59:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.27093 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.27093 0.00010 -0.27093 0.00000 16:59:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.27093 0.00010 SL = -0.2709296 +- 0.0001041 Tm^2/m^n 16:59:11 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2709296 +- 0.0001041 Tm^2/m^n Remeasure 16:59:11 Magnetic Field Measurement Measuring the magnet strength... 16:59:11 Integrated Voltage Measurement... 16:59:12 Magnet Current for MAIN, Imag = 240.1245 A Vtrans = 2.401323 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:59:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024373938 Vs 16:59:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024388081 Vs 16:59:28 Magnet Current for MAIN, Imag = 240.1250 A Vtrans = 2.401328 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:59:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024372925 Vs 16:59:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024373062 Vs 16:59:44 Magnet Current for MAIN, Imag = 240.1247 A Vtrans = 2.401326 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 16:59:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024369104 Vs 17:00:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024373358 Vs 17:00:00 Magnet Current for MAIN, Imag = 240.1246 A Vtrans = 2.401325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:00:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024381936 Vs 17:00:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024376456 Vs 17:00:17 Magnet Current for MAIN, Imag = 240.1246 A Vtrans = 2.401325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:00:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024380477 Vs 17:00:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.024402906 Vs 17:00:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.024379224 +- 0.000007229 Vs 17:00:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.024379224 +- 0.000007229 Vs BL = -0.27088027 +- 0.00008033 Tm 17:00:36 Position moved: 0.000000 m 17:00:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.27088 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.27088 0.00008 -0.27088 0.00000 17:00:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.27088 0.00008 SL = -0.2708803 +- 0.0000803 Tm^2/m^n 17:00:36 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2708803 +- 0.0000803 Tm^2/m^n 17:00:39 Position moved: 0.000000 m 17:00:39 Magnet system MAIN current ramping to 200.0000 A... 17:00:54 Magnet Current for MAIN, Imag = 200.1312 A Vtrans = 2.001391 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:00:54 MAIN (V) Voltage Measurement, V = 4.345589 V 17:00:55 Temperature Measurement, Probe Number = 0, T = 31.150000 C 17:00:56 Temperature Measurement, Probe Number = 1, T = 29.057000 C 17:00:56 Temperature Measurement, Probe Number = 2, T = 29.543000 C 17:00:57 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377197 V 17:00:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377197 (V, A, ohm, ...), Measured Value = 29.127738 (C, atm, Hz, ...) 17:00:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.653665 V 17:00:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.653665 (V, A, ohm, ...), Measured Value = 32.967569 (C, atm, Hz, ...) 17:00:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.672563 V 17:00:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.672563 (V, A, ohm, ...), Measured Value = 125.442255 (C, atm, Hz, ...) 17:00:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105341 V 17:00:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105341 (V, A, ohm, ...), Measured Value = 7.900560 (C, atm, Hz, ...) 17:00:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.13 P1 = MAIN (V), Value = 4.35 P2 = Magnet Core, Value = 31.15 P3 = Coil, Value = 29.06 P4 = Ambient Temp (C), Value = 29.54 P5 = Supply Temp(C), Value = 29.13 P6 = Return Temp(C), Value = 32.97 P7 = Supply Pres(psi), Value = 125.44 P8 = Return Pres(psi), Value = 7.90 17:00:59 Magnetic Field Measurement Measuring the magnet strength... 17:00:59 Integrated Voltage Measurement... 17:01:00 Magnet Current for MAIN, Imag = 200.1312 A Vtrans = 2.001391 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:01:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020379116 Vs 17:01:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020373885 Vs 17:01:17 Magnet Current for MAIN, Imag = 200.1308 A Vtrans = 2.001387 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:01:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020369561 Vs 17:01:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020391784 Vs 17:01:33 Magnet Current for MAIN, Imag = 200.1311 A Vtrans = 2.001390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:01:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020345986 Vs 17:01:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020383479 Vs 17:01:49 Magnet Current for MAIN, Imag = 200.1312 A Vtrans = 2.001391 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:01:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020372482 Vs 17:02:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020366851 Vs 17:02:05 Magnet Current for MAIN, Imag = 200.1310 A Vtrans = 2.001388 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:02:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020369928 Vs 17:02:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020378136 Vs 17:02:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020373121 +- 0.000005506 Vs 17:02:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.020373121 +- 0.000005506 Vs BL = -0.22636801 +- 0.00006118 Tm 17:02:25 Position moved: 0.000000 m 17:02:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.22637 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.22637 0.00006 -0.22637 0.00000 17:02:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.22637 0.00006 SL = -0.2263680 +- 0.0000612 Tm^2/m^n 17:02:25 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2263680 +- 0.0000612 Tm^2/m^n Remeasure 17:02:25 Magnetic Field Measurement Measuring the magnet strength... 17:02:25 Integrated Voltage Measurement... 17:02:26 Magnet Current for MAIN, Imag = 200.1311 A Vtrans = 2.001390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:02:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020382366 Vs 17:02:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020358446 Vs 17:02:43 Magnet Current for MAIN, Imag = 200.1310 A Vtrans = 2.001388 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:02:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020368587 Vs 17:02:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020373728 Vs 17:02:59 Magnet Current for MAIN, Imag = 200.1308 A Vtrans = 2.001387 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:03:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020366203 Vs 17:03:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020388760 Vs 17:03:15 Magnet Current for MAIN, Imag = 200.1307 A Vtrans = 2.001386 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:03:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020346161 Vs 17:03:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020383869 Vs 17:03:32 Magnet Current for MAIN, Imag = 200.1307 A Vtrans = 2.001386 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:03:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020350241 Vs 17:03:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.020379739 Vs 17:03:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.020369810 +- 0.000004631 Vs 17:03:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.020369810 +- 0.000004631 Vs BL = -0.22633122 +- 0.00005146 Tm 17:03:51 Position moved: 0.000000 m 17:03:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.22633 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.22633 0.00005 -0.22633 0.00000 17:03:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.22633 0.00005 SL = -0.2263312 +- 0.0000515 Tm^2/m^n 17:03:51 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2263312 +- 0.0000515 Tm^2/m^n 17:03:54 Position moved: 0.000000 m 17:03:54 Magnet system MAIN current ramping to 160.0000 A... 17:04:09 Magnet Current for MAIN, Imag = 160.0748 A Vtrans = 1.600826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:04:09 MAIN (V) Voltage Measurement, V = 3.467954 V 17:04:10 Temperature Measurement, Probe Number = 0, T = 31.017000 C 17:04:11 Temperature Measurement, Probe Number = 1, T = 29.084000 C 17:04:11 Temperature Measurement, Probe Number = 2, T = 29.558000 C 17:04:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377727 V 17:04:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377727 (V, A, ohm, ...), Measured Value = 29.135099 (C, atm, Hz, ...) 17:04:13 Sensor Voltage Measurement, Sensor Number = 1, V = 2.631734 V 17:04:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.631734 (V, A, ohm, ...), Measured Value = 32.662971 (C, atm, Hz, ...) 17:04:14 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658992 V 17:04:14 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658992 (V, A, ohm, ...), Measured Value = 124.424407 (C, atm, Hz, ...) 17:04:15 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105375 V 17:04:15 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105375 (V, A, ohm, ...), Measured Value = 7.903133 (C, atm, Hz, ...) 17:04:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 160.07 P1 = MAIN (V), Value = 3.47 P2 = Magnet Core, Value = 31.02 P3 = Coil, Value = 29.08 P4 = Ambient Temp (C), Value = 29.56 P5 = Supply Temp(C), Value = 29.14 P6 = Return Temp(C), Value = 32.66 P7 = Supply Pres(psi), Value = 124.42 P8 = Return Pres(psi), Value = 7.90 17:04:15 Magnetic Field Measurement Measuring the magnet strength... 17:04:15 Integrated Voltage Measurement... 17:04:16 Magnet Current for MAIN, Imag = 160.0754 A Vtrans = 1.600833 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:04:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016334064 Vs 17:04:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016356548 Vs 17:04:33 Magnet Current for MAIN, Imag = 160.0752 A Vtrans = 1.600830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:04:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016333059 Vs 17:04:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016341378 Vs 17:04:49 Magnet Current for MAIN, Imag = 160.0752 A Vtrans = 1.600830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:04:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016326883 Vs 17:05:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016345693 Vs 17:05:05 Magnet Current for MAIN, Imag = 160.0750 A Vtrans = 1.600829 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:05:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016321440 Vs 17:05:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016347739 Vs 17:05:21 Magnet Current for MAIN, Imag = 160.0749 A Vtrans = 1.600828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:05:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016320324 Vs 17:05:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016347974 Vs 17:05:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016337510 +- 0.000004054 Vs 17:05:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016337510 +- 0.000004054 Vs BL = -0.18152789 +- 0.00004505 Tm 17:05:41 Position moved: 0.000000 m 17:05:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18153 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18153 0.00005 -0.18153 0.00000 17:05:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18153 0.00005 SL = -0.1815279 +- 0.0000450 Tm^2/m^n 17:05:41 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1815279 +- 0.0000450 Tm^2/m^n Remeasure 17:05:41 Magnetic Field Measurement Measuring the magnet strength... 17:05:41 Integrated Voltage Measurement... 17:05:42 Magnet Current for MAIN, Imag = 160.0747 A Vtrans = 1.600825 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:05:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016320547 Vs 17:05:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016347156 Vs 17:05:59 Magnet Current for MAIN, Imag = 160.0748 A Vtrans = 1.600826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:06:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016328927 Vs 17:06:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016346886 Vs 17:06:15 Magnet Current for MAIN, Imag = 160.0750 A Vtrans = 1.600829 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:06:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016324476 Vs 17:06:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016337723 Vs 17:06:31 Magnet Current for MAIN, Imag = 160.0752 A Vtrans = 1.600830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:06:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016340164 Vs 17:06:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016327630 Vs 17:06:47 Magnet Current for MAIN, Imag = 160.0752 A Vtrans = 1.600830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:06:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016323303 Vs 17:07:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016333281 Vs 17:07:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016333009 +- 0.000003206 Vs 17:07:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016333009 +- 0.000003206 Vs BL = -0.18147788 +- 0.00003562 Tm 17:07:07 Position moved: 0.000000 m 17:07:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18148 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18148 0.00004 -0.18148 0.00000 17:07:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18148 0.00004 SL = -0.1814779 +- 0.0000356 Tm^2/m^n 17:07:07 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1814779 +- 0.0000356 Tm^2/m^n 17:07:10 Position moved: 0.000000 m 17:07:10 Magnet system MAIN current ramping to 120.0000 A... 17:07:25 Magnet Current for MAIN, Imag = 120.0058 A Vtrans = 1.200136 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:07:25 MAIN (V) Voltage Measurement, V = 2.594957 V 17:07:26 Temperature Measurement, Probe Number = 0, T = 30.835000 C 17:07:27 Temperature Measurement, Probe Number = 1, T = 29.104000 C 17:07:27 Temperature Measurement, Probe Number = 2, T = 29.540000 C 17:07:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377915 V 17:07:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377915 (V, A, ohm, ...), Measured Value = 29.137711 (C, atm, Hz, ...) 17:07:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.597815 V 17:07:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.597815 (V, A, ohm, ...), Measured Value = 32.191878 (C, atm, Hz, ...) 17:07:29 Sensor Voltage Measurement, Sensor Number = 2, V = 2.654280 V 17:07:29 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.654280 (V, A, ohm, ...), Measured Value = 124.071015 (C, atm, Hz, ...) 17:07:30 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105116 V 17:07:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105116 (V, A, ohm, ...), Measured Value = 7.883685 (C, atm, Hz, ...) 17:07:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 120.01 P1 = MAIN (V), Value = 2.59 P2 = Magnet Core, Value = 30.84 P3 = Coil, Value = 29.10 P4 = Ambient Temp (C), Value = 29.54 P5 = Supply Temp(C), Value = 29.14 P6 = Return Temp(C), Value = 32.19 P7 = Supply Pres(psi), Value = 124.07 P8 = Return Pres(psi), Value = 7.88 17:07:30 Magnetic Field Measurement Measuring the magnet strength... 17:07:30 Integrated Voltage Measurement... 17:07:31 Magnet Current for MAIN, Imag = 120.0060 A Vtrans = 1.200139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:07:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012296717 Vs 17:07:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012307077 Vs 17:07:48 Magnet Current for MAIN, Imag = 120.0059 A Vtrans = 1.200138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:07:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012292718 Vs 17:08:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012301078 Vs 17:08:04 Magnet Current for MAIN, Imag = 120.0061 A Vtrans = 1.200140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:08:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012286540 Vs 17:08:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012296336 Vs 17:08:20 Magnet Current for MAIN, Imag = 120.0063 A Vtrans = 1.200141 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:08:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012289862 Vs 17:08:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012298066 Vs 17:08:36 Magnet Current for MAIN, Imag = 120.0061 A Vtrans = 1.200140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:08:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012286396 Vs 17:08:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012303562 Vs 17:08:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012295835 +- 0.000003506 Vs 17:08:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.012295835 +- 0.000003506 Vs BL = -0.13662039 +- 0.00003895 Tm 17:08:56 Position moved: 0.000000 m 17:08:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.13662 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.13662 0.00004 -0.13662 0.00000 17:08:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.13662 0.00004 SL = -0.1366204 +- 0.0000390 Tm^2/m^n 17:08:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1366204 +- 0.0000390 Tm^2/m^n Remeasure 17:08:56 Magnetic Field Measurement Measuring the magnet strength... 17:08:56 Integrated Voltage Measurement... 17:08:57 Magnet Current for MAIN, Imag = 120.0058 A Vtrans = 1.200136 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:09:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012299612 Vs 17:09:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012298942 Vs 17:09:14 Magnet Current for MAIN, Imag = 120.0054 A Vtrans = 1.200132 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:09:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012293208 Vs 17:09:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012295687 Vs 17:09:30 Magnet Current for MAIN, Imag = 120.0054 A Vtrans = 1.200132 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:09:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012284222 Vs 17:09:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012289650 Vs 17:09:47 Magnet Current for MAIN, Imag = 120.0055 A Vtrans = 1.200134 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:09:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012292357 Vs 17:10:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012291237 Vs 17:10:03 Magnet Current for MAIN, Imag = 120.0059 A Vtrans = 1.200138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:10:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012283450 Vs 17:10:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012290559 Vs 17:10:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012291892 +- 0.000004680 Vs 17:10:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.012291892 +- 0.000004680 Vs BL = -0.13657658 +- 0.00005200 Tm 17:10:22 Position moved: 0.000000 m 17:10:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.13658 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.13658 0.00005 -0.13658 0.00000 17:10:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.13658 0.00005 SL = -0.1365766 +- 0.0000520 Tm^2/m^n 17:10:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1365766 +- 0.0000520 Tm^2/m^n Remeasure 17:10:22 Magnetic Field Measurement Measuring the magnet strength... 17:10:22 Integrated Voltage Measurement... 17:10:23 Magnet Current for MAIN, Imag = 120.0058 A Vtrans = 1.200136 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:10:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012292210 Vs 17:10:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012295558 Vs 17:10:40 Magnet Current for MAIN, Imag = 120.0059 A Vtrans = 1.200138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:10:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012279911 Vs 17:10:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012292827 Vs 17:10:56 Magnet Current for MAIN, Imag = 120.0054 A Vtrans = 1.200132 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:11:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012282569 Vs 17:11:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012295904 Vs 17:11:12 Magnet Current for MAIN, Imag = 120.0055 A Vtrans = 1.200134 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:11:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012288473 Vs 17:11:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012297857 Vs 17:11:28 Magnet Current for MAIN, Imag = 120.0059 A Vtrans = 1.200138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:11:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012281805 Vs 17:11:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.012302355 Vs 17:11:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.012290947 +- 0.000002782 Vs 17:11:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.012290947 +- 0.000002782 Vs BL = -0.13656608 +- 0.00003092 Tm 17:11:48 Position moved: 0.000000 m 17:11:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.13657 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.13657 0.00003 -0.13657 0.00000 17:11:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.13657 0.00003 SL = -0.1365661 +- 0.0000309 Tm^2/m^n 17:11:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1365661 +- 0.0000309 Tm^2/m^n 17:11:51 Position moved: 0.000000 m 17:11:51 Magnet system MAIN current ramping to 80.0000 A... 17:12:06 Magnet Current for MAIN, Imag = 80.0330 A Vtrans = 0.800408 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:12:06 MAIN (V) Voltage Measurement, V = 1.728005 V 17:12:07 Temperature Measurement, Probe Number = 0, T = 30.511000 C 17:12:08 Temperature Measurement, Probe Number = 1, T = 29.123000 C 17:12:08 Temperature Measurement, Probe Number = 2, T = 29.569000 C 17:12:09 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377877 V 17:12:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377877 (V, A, ohm, ...), Measured Value = 29.137182 (C, atm, Hz, ...) 17:12:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.545737 V 17:12:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.545737 (V, A, ohm, ...), Measured Value = 31.468567 (C, atm, Hz, ...) 17:12:10 Sensor Voltage Measurement, Sensor Number = 2, V = 2.670516 V 17:12:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670516 (V, A, ohm, ...), Measured Value = 125.288678 (C, atm, Hz, ...) 17:12:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104939 V 17:12:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104939 (V, A, ohm, ...), Measured Value = 7.870432 (C, atm, Hz, ...) 17:12:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 80.03 P1 = MAIN (V), Value = 1.73 P2 = Magnet Core, Value = 30.51 P3 = Coil, Value = 29.12 P4 = Ambient Temp (C), Value = 29.57 P5 = Supply Temp(C), Value = 29.14 P6 = Return Temp(C), Value = 31.47 P7 = Supply Pres(psi), Value = 125.29 P8 = Return Pres(psi), Value = 7.87 17:12:11 Magnetic Field Measurement Measuring the magnet strength... 17:12:11 Integrated Voltage Measurement... 17:12:12 Magnet Current for MAIN, Imag = 80.0331 A Vtrans = 0.800409 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:12:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008249625 Vs 17:12:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008249567 Vs 17:12:29 Magnet Current for MAIN, Imag = 80.0331 A Vtrans = 0.800409 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:12:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008249052 Vs 17:12:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008252857 Vs 17:12:45 Magnet Current for MAIN, Imag = 80.0330 A Vtrans = 0.800408 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:12:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008240861 Vs 17:13:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008259136 Vs 17:13:01 Magnet Current for MAIN, Imag = 80.0328 A Vtrans = 0.800407 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:13:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008249001 Vs 17:13:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008257873 Vs 17:13:17 Magnet Current for MAIN, Imag = 80.0328 A Vtrans = 0.800407 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:13:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008252432 Vs 17:13:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.008252780 Vs 17:13:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.008251318 +- 0.000001482 Vs 17:13:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.008251318 +- 0.000001482 Vs BL = -0.09168132 +- 0.00001647 Tm 17:13:37 Position moved: 0.000000 m 17:13:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.09168 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.09168 0.00002 -0.09168 0.00000 17:13:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.09168 0.00002 SL = -0.0916813 +- 0.0000165 Tm^2/m^n 17:13:37 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0916813 +- 0.0000165 Tm^2/m^n 17:13:40 Position moved: 0.000000 m 17:13:40 Magnet system MAIN current ramping to 40.0000 A... 17:13:55 Magnet Current for MAIN, Imag = 39.9730 A Vtrans = 0.399808 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:13:55 MAIN (V) Voltage Measurement, V = 0.862214 V 17:13:56 Temperature Measurement, Probe Number = 0, T = 30.396000 C 17:13:57 Temperature Measurement, Probe Number = 1, T = 29.124000 C 17:13:57 Temperature Measurement, Probe Number = 2, T = 29.561000 C 17:13:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377725 V 17:13:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377725 (V, A, ohm, ...), Measured Value = 29.135064 (C, atm, Hz, ...) 17:13:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.529906 V 17:13:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.529906 (V, A, ohm, ...), Measured Value = 31.248689 (C, atm, Hz, ...) 17:13:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659197 V 17:13:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659197 (V, A, ohm, ...), Measured Value = 124.439760 (C, atm, Hz, ...) 17:14:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104848 V 17:14:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104848 (V, A, ohm, ...), Measured Value = 7.863570 (C, atm, Hz, ...) 17:14:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.97 P1 = MAIN (V), Value = 0.86 P2 = Magnet Core, Value = 30.40 P3 = Coil, Value = 29.12 P4 = Ambient Temp (C), Value = 29.56 P5 = Supply Temp(C), Value = 29.14 P6 = Return Temp(C), Value = 31.25 P7 = Supply Pres(psi), Value = 124.44 P8 = Return Pres(psi), Value = 7.86 17:14:00 Magnetic Field Measurement Measuring the magnet strength... 17:14:00 Integrated Voltage Measurement... 17:14:01 Magnet Current for MAIN, Imag = 39.9731 A Vtrans = 0.399809 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:14:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004190466 Vs 17:14:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.004198514 Vs 17:14:18 Magnet Current for MAIN, Imag = 39.9730 A Vtrans = 0.399809 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:14:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004192887 Vs 17:14:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.004196001 Vs 17:14:34 Magnet Current for MAIN, Imag = 39.9729 A Vtrans = 0.399807 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:14:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004195273 Vs 17:14:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.004197042 Vs 17:14:50 Magnet Current for MAIN, Imag = 39.9731 A Vtrans = 0.399809 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:14:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004190920 Vs 17:15:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.004197140 Vs 17:15:07 Magnet Current for MAIN, Imag = 39.9731 A Vtrans = 0.399810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:15:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004191157 Vs 17:15:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.004199912 Vs 17:15:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.004194931 +- 0.000000789 Vs 17:15:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.004194931 +- 0.000000789 Vs BL = -0.04661035 +- 0.00000876 Tm 17:15:26 Position moved: 0.000000 m 17:15:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04661 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04661 0.00001 -0.04661 0.00000 17:15:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04661 0.00001 SL = -0.0466103 +- 0.0000088 Tm^2/m^n 17:15:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0466103 +- 0.0000088 Tm^2/m^n 17:15:29 Position moved: 0.000000 m 17:15:29 Magnet system MAIN current ramping to 20.0000 A... 17:15:42 Magnet Current for MAIN, Imag = 19.9823 A Vtrans = 0.199902 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:15:43 MAIN (V) Voltage Measurement, V = 0.430786 V 17:15:43 Temperature Measurement, Probe Number = 0, T = 30.289000 C 17:15:44 Temperature Measurement, Probe Number = 1, T = 29.128000 C 17:15:45 Temperature Measurement, Probe Number = 2, T = 29.603000 C 17:15:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377525 V 17:15:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377525 (V, A, ohm, ...), Measured Value = 29.132292 (C, atm, Hz, ...) 17:15:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.514438 V 17:15:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.514438 (V, A, ohm, ...), Measured Value = 31.033856 (C, atm, Hz, ...) 17:15:47 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657342 V 17:15:47 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657342 (V, A, ohm, ...), Measured Value = 124.300672 (C, atm, Hz, ...) 17:15:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104527 V 17:15:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104527 (V, A, ohm, ...), Measured Value = 7.839547 (C, atm, Hz, ...) 17:15:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.98 P1 = MAIN (V), Value = 0.43 P2 = Magnet Core, Value = 30.29 P3 = Coil, Value = 29.13 P4 = Ambient Temp (C), Value = 29.60 P5 = Supply Temp(C), Value = 29.13 P6 = Return Temp(C), Value = 31.03 P7 = Supply Pres(psi), Value = 124.30 P8 = Return Pres(psi), Value = 7.84 17:15:47 Magnetic Field Measurement Measuring the magnet strength... 17:15:47 Integrated Voltage Measurement... 17:15:48 Magnet Current for MAIN, Imag = 19.9823 A Vtrans = 0.199901 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:15:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002169669 Vs 17:16:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002175902 Vs 17:16:06 Magnet Current for MAIN, Imag = 19.9822 A Vtrans = 0.199900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:16:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002170325 Vs 17:16:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002174064 Vs 17:16:22 Magnet Current for MAIN, Imag = 19.9822 A Vtrans = 0.199900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:16:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002171082 Vs 17:16:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002173898 Vs 17:16:38 Magnet Current for MAIN, Imag = 19.9823 A Vtrans = 0.199901 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:16:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002171510 Vs 17:16:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002170452 Vs 17:16:54 Magnet Current for MAIN, Imag = 19.9822 A Vtrans = 0.199900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:17:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002169649 Vs 17:17:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002175001 Vs 17:17:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002172155 +- 0.000000619 Vs 17:17:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.002172155 +- 0.000000619 Vs BL = -0.02413506 +- 0.00000688 Tm 17:17:13 Position moved: 0.000000 m 17:17:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02414 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02414 0.00001 -0.02414 0.00000 17:17:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02414 0.00001 SL = -0.0241351 +- 0.0000069 Tm^2/m^n 17:17:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0241351 +- 0.0000069 Tm^2/m^n Remeasure 17:17:14 Magnetic Field Measurement Measuring the magnet strength... 17:17:14 Integrated Voltage Measurement... 17:17:14 Magnet Current for MAIN, Imag = 19.9824 A Vtrans = 0.199902 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:17:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002167622 Vs 17:17:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002175113 Vs 17:17:32 Magnet Current for MAIN, Imag = 19.9824 A Vtrans = 0.199902 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:17:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002167666 Vs 17:17:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002175377 Vs 17:17:48 Magnet Current for MAIN, Imag = 19.9823 A Vtrans = 0.199901 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:17:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002169021 Vs 17:18:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002173214 Vs 17:18:04 Magnet Current for MAIN, Imag = 19.9821 A Vtrans = 0.199900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:18:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002168329 Vs 17:18:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002174800 Vs 17:18:20 Magnet Current for MAIN, Imag = 19.9821 A Vtrans = 0.199900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:18:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002169836 Vs 17:18:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.002172734 Vs 17:18:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.002171371 +- 0.000000162 Vs 17:18:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.002171371 +- 0.000000162 Vs BL = -0.02412635 +- 0.00000180 Tm 17:18:39 Position moved: 0.000000 m 17:18:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02413 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02413 0.00000 -0.02413 0.00000 17:18:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02413 0.00000 SL = -0.0241263 +- 0.0000018 Tm^2/m^n 17:18:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0241263 +- 0.0000018 Tm^2/m^n 17:18:43 Position moved: 0.000000 m 17:18:43 Magnet system MAIN current ramping to 10.0000 A... 17:18:55 Magnet Current for MAIN, Imag = 9.9936 A Vtrans = 0.100014 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:18:55 MAIN (V) Voltage Measurement, V = 0.215392 V 17:18:56 Temperature Measurement, Probe Number = 0, T = 30.110000 C 17:18:57 Temperature Measurement, Probe Number = 1, T = 29.133000 C 17:18:57 Temperature Measurement, Probe Number = 2, T = 29.575000 C 17:18:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376940 V 17:18:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376940 (V, A, ohm, ...), Measured Value = 29.124171 (C, atm, Hz, ...) 17:18:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.488763 V 17:18:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.488763 (V, A, ohm, ...), Measured Value = 30.677267 (C, atm, Hz, ...) 17:18:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.670281 V 17:18:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670281 (V, A, ohm, ...), Measured Value = 125.271038 (C, atm, Hz, ...) 17:19:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104745 V 17:19:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104745 (V, A, ohm, ...), Measured Value = 7.855852 (C, atm, Hz, ...) 17:19:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 9.99 P1 = MAIN (V), Value = 0.22 P2 = Magnet Core, Value = 30.11 P3 = Coil, Value = 29.13 P4 = Ambient Temp (C), Value = 29.57 P5 = Supply Temp(C), Value = 29.12 P6 = Return Temp(C), Value = 30.68 P7 = Supply Pres(psi), Value = 125.27 P8 = Return Pres(psi), Value = 7.86 17:19:00 Magnetic Field Measurement Measuring the magnet strength... 17:19:00 Integrated Voltage Measurement... 17:19:01 Magnet Current for MAIN, Imag = 9.9935 A Vtrans = 0.100014 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:19:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001159264 Vs 17:19:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001164527 Vs 17:19:18 Magnet Current for MAIN, Imag = 9.9937 A Vtrans = 0.100016 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:19:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001157659 Vs 17:19:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001163119 Vs 17:19:34 Magnet Current for MAIN, Imag = 9.9934 A Vtrans = 0.100012 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:19:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001158464 Vs 17:19:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001162937 Vs 17:19:50 Magnet Current for MAIN, Imag = 9.9934 A Vtrans = 0.100012 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:19:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001158586 Vs 17:20:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001163065 Vs 17:20:06 Magnet Current for MAIN, Imag = 9.9934 A Vtrans = 0.100013 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:20:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001158001 Vs 17:20:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001163450 Vs 17:20:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001160907 +- 0.000000515 Vs 17:20:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.001160907 +- 0.000000515 Vs BL = -0.01289897 +- 0.00000573 Tm 17:20:25 Position moved: 0.000000 m 17:20:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01290 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01290 0.00001 -0.01290 0.00000 17:20:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01290 0.00001 SL = -0.0128990 +- 0.0000057 Tm^2/m^n 17:20:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0128990 +- 0.0000057 Tm^2/m^n Remeasure 17:20:26 Magnetic Field Measurement Measuring the magnet strength... 17:20:26 Integrated Voltage Measurement... 17:20:26 Magnet Current for MAIN, Imag = 9.9935 A Vtrans = 0.100014 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:20:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001159681 Vs 17:20:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001163593 Vs 17:20:44 Magnet Current for MAIN, Imag = 9.9935 A Vtrans = 0.100014 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:20:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001158754 Vs 17:20:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001163476 Vs 17:21:00 Magnet Current for MAIN, Imag = 9.9936 A Vtrans = 0.100015 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:21:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001158192 Vs 17:21:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001164438 Vs 17:21:16 Magnet Current for MAIN, Imag = 9.9933 A Vtrans = 0.100012 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:21:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001159720 Vs 17:21:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001161705 Vs 17:21:32 Magnet Current for MAIN, Imag = 9.9932 A Vtrans = 0.100011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:21:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001160549 Vs 17:21:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001161785 Vs 17:21:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001161189 +- 0.000000300 Vs 17:21:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.001161189 +- 0.000000300 Vs BL = -0.01290210 +- 0.00000333 Tm 17:21:51 Position moved: 0.000000 m 17:21:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01290 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01290 0.00000 -0.01290 0.00000 17:21:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01290 0.00000 SL = -0.0129021 +- 0.0000033 Tm^2/m^n 17:21:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0129021 +- 0.0000033 Tm^2/m^n Remeasure 17:21:52 Magnetic Field Measurement Measuring the magnet strength... 17:21:52 Integrated Voltage Measurement... 17:21:52 Magnet Current for MAIN, Imag = 9.9931 A Vtrans = 0.100009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:22:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001159592 Vs 17:22:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001161134 Vs 17:22:10 Magnet Current for MAIN, Imag = 9.9934 A Vtrans = 0.100012 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:22:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001161112 Vs 17:22:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001161117 Vs 17:22:26 Magnet Current for MAIN, Imag = 9.9934 A Vtrans = 0.100012 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:22:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001160754 Vs 17:22:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001161375 Vs 17:22:42 Magnet Current for MAIN, Imag = 9.9933 A Vtrans = 0.100011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:22:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001161187 Vs 17:22:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001161450 Vs 17:22:58 Magnet Current for MAIN, Imag = 9.9932 A Vtrans = 0.100010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:23:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001159293 Vs 17:23:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.001161531 Vs 17:23:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.001160854 +- 0.000000391 Vs 17:23:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.001160854 +- 0.000000391 Vs BL = -0.01289838 +- 0.00000435 Tm 17:23:17 Position moved: 0.000000 m 17:23:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01290 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01290 0.00000 -0.01290 0.00000 17:23:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01290 0.00000 SL = -0.0128984 +- 0.0000043 Tm^2/m^n 17:23:17 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0128984 +- 0.0000043 Tm^2/m^n 17:23:20 Position moved: 0.000000 m 17:23:20 Magnet system MAIN current ramping to 0.0000 A... 17:23:32 Magnet Current for MAIN, Imag = 0.0060 A Vtrans = 0.000139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:23:33 MAIN (V) Voltage Measurement, V = 0.000122 V 17:23:34 Temperature Measurement, Probe Number = 0, T = 29.931000 C 17:23:34 Temperature Measurement, Probe Number = 1, T = 29.144000 C 17:23:35 Temperature Measurement, Probe Number = 2, T = 29.619000 C 17:23:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376052 V 17:23:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376052 (V, A, ohm, ...), Measured Value = 29.111831 (C, atm, Hz, ...) 17:23:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.464463 V 17:23:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.464463 (V, A, ohm, ...), Measured Value = 30.339761 (C, atm, Hz, ...) 17:23:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657801 V 17:23:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657801 (V, A, ohm, ...), Measured Value = 124.335082 (C, atm, Hz, ...) 17:23:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104268 V 17:23:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104268 (V, A, ohm, ...), Measured Value = 7.820100 (C, atm, Hz, ...) 17:23:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.01 P1 = MAIN (V), Value = 0.00 P2 = Magnet Core, Value = 29.93 P3 = Coil, Value = 29.14 P4 = Ambient Temp (C), Value = 29.62 P5 = Supply Temp(C), Value = 29.11 P6 = Return Temp(C), Value = 30.34 P7 = Supply Pres(psi), Value = 124.34 P8 = Return Pres(psi), Value = 7.82 17:23:38 Magnetic Field Measurement Measuring the magnet strength... 17:23:38 Integrated Voltage Measurement... 17:23:38 Magnet Current for MAIN, Imag = 0.0060 A Vtrans = 0.000138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:23:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000149827 Vs 17:23:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000151721 Vs 17:23:55 Magnet Current for MAIN, Imag = 0.0058 A Vtrans = 0.000136 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:24:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000148951 Vs 17:24:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000150523 Vs 17:24:12 Magnet Current for MAIN, Imag = 0.0058 A Vtrans = 0.000137 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:24:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000149997 Vs 17:24:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000152171 Vs 17:24:28 Magnet Current for MAIN, Imag = 0.0058 A Vtrans = 0.000137 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:24:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000148922 Vs 17:24:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000150721 Vs 17:24:44 Magnet Current for MAIN, Imag = 0.0057 A Vtrans = 0.000136 V, Factor V/A = 0.010000 V/A, Zero Current = 0.007853 A 17:24:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000149035 Vs 17:24:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000150140 Vs 17:24:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000150201 +- 0.000000607 Vs 17:24:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.000150201 +- 0.000000607 Vs BL = -0.00166890 +- 0.00000675 Tm 17:25:03 Position moved: 0.000000 m 17:25:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00167 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00167 0.00001 -0.00167 0.00000 17:25:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00167 0.00001 SL = -0.0016689 +- 0.0000067 Tm^2/m^n 17:25:03 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0016689 +- 0.0000067 Tm^2/m^n 17:25:06 Position moved: 0.000000 m 17:25:09 Position moved: 0.000000 m 17:25:12 Magnet system MAIN current ramping to 0.0000 A...