SLAC Magnetic Measurements Date: 10-16-2018 Time: 10:43:37 Project: LCLS-II Magnet Type: Dipole Magnet Name: 3D8.8 Serial Number: 17 Run Number: 6 Measurement Device: 10wire Operator: sda Comment: Degauss proceedure 6 Amp max, f = 0.88 with 51 points. 6 A/sec ramp, 2 sec wait, no stdz Test Currents for MAIN (A): 6.00 -5.28 4.65 -4.09 3.60 -3.17 2.79 -2.45 2.16 -1.90 1.67 -1.47 1.29 -1.14 1.00 -0.88 0.78 -0.68 0.60 -0.53 0.47 -0.41 0.36 -0.32 0.28 -0.25 0.22 -0.19 0.17 -0.15 0.13 -0.11 0.10 -0.09 0.08 -0.07 0.06 -0.05 0.05 -0.04 0.04 -0.03 0.03 -0.02 0.02 -0.02 0.02 -0.01 0.01 -0.01 0.00 Integrated Dipole Strength Distance the wire was to be moved = 0.009000 m Number of turns in the wire = 10 Number of measurements for averaging = 4 MAIN +/- sigma BL sigBL BL/I sigBL/I (A) (A) (Tm) (Tm) (Tm/A) (Tm/A) ------------+---------- -------------+------------ -------------+------------- 0.0000 0.0000 0.000033 0.000003 0.000000 0.000000