SLAC Magnetic Measurements Date: 09-12-2016 Time: 17:47:24 Project: LCLS2 Magnet Type: Dipole Magnet Name: BX31b Serial Number: 16102 Run Number: 4 Measurement Device: 1wire Operator: sda Comment: Integrated strength vs trim current. Trim currents from 0 to -6 to 6 to 0 amps in 1 A steps. Main standardized then set to zero for the measurements. Standardization for Main : 3 cycles from 0.0 A to 170.0 A to 0.0 A Test Currents for Main (A): 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Test Currents for HTrim (A): 0.00 -1.00 -2.00 -3.00 -4.00 -5.00 -6.00 -5.00 -4.00 -3.00 -2.00 -1.00 0.00 1.00 2.00 3.00 4.00 5.00 6.00 5.00 4.00 3.00 2.00 1.00 0.00 17:47:50 Position moved: 0.000000 m 17:47:53 Magnet Current for Main , Imag = 0.0230 A Vtrans = 0.000230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:47:53 Magnet Current for Main , Imag = 0.0230 A Vtrans = 0.000230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:47:54 Magnet Current for Main , Imag = 0.0230 A Vtrans = 0.000230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:47:54 Magnet Current for Main , Imag = 0.0231 A Vtrans = 0.000231 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:47:54 Magnet Avgerage Current Measurement for Main : Imag = 0.0230 +- 0.0000 A 17:47:56 Initial Zero Current Measurement for Main , Imag_zero = 0.023031 A 17:47:59 Magnet Current for HTrim , Imag = 0.0020 A Vtrans = 0.000332 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 17:47:59 Magnet Current for HTrim , Imag = 0.0020 A Vtrans = 0.000332 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 17:48:00 Magnet Current for HTrim , Imag = 0.0020 A Vtrans = 0.000332 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 17:48:01 Magnet Current for HTrim , Imag = 0.0020 A Vtrans = 0.000332 V, Factor V/A = 0.166667 V/A, Zero Current = 0.000000 A 17:48:01 Magnet Avgerage Current Measurement for HTrim : Imag = 0.0020 +- 0.0000 A 17:48:38 Initial Zero Current Measurement for HTrim , Imag_zero = 0.00199198 A 17:48:38 Ambient Measurement Device(s) Being Used, type = None 17:48:38 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 17:48:39 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 17:48:39 XMAG Device(s) Being Used, type = None 17:48:39 Ambient Measurement Device(s) Being Used, type = None 17:48:39 Magnet system Main current ramping to 170.0000 A... 17:49:37 Magnet system Main current ramping to 0.0000 A... 17:50:34 Magnet system Main current ramping to 170.0000 A... 17:51:32 Magnet system Main current ramping to 0.0000 A... 17:52:30 Magnet system Main current ramping to 170.0000 A... 17:53:28 Magnet system Main current ramping to 0.0000 A... 17:54:29 Position moved: 0.000000 m 17:54:31 Magnet system Main current ramping to 0.0000 A... 17:54:42 Magnet system HTrim current ramping to 0.0000 A... 17:54:45 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:54:45 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000314 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:54:46 MAIN Voltage Measurement, V = 0.000593 V 17:54:47 Temperature Measurement, Probe Number = 0, T = 28.109000 C 17:54:47 Temperature Measurement, Probe Number = 1, T = 28.956000 C 17:54:48 Temperature Measurement, Probe Number = 2, T = 25.043000 C 17:54:48 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -0.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.11 P4 = Coil, Value = 28.96 P5 = Ambient Temp, Value = 25.04 17:54:48 Magnetic Field Measurement Measuring the magnet strength... 17:54:48 Integrated Voltage Measurement... 17:54:49 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:54:49 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000315 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:54:57 Voltage Offset Correction: v_off_ini = -0.000001696 V, v_off_fin = -0.000000996 V 17:54:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035350 Vs 17:55:04 Voltage Offset Correction: v_off_ini = -0.000001268 V, v_off_fin = -0.000001700 V 17:55:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035551 Vs 17:55:04 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:55:05 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000315 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:55:12 Voltage Offset Correction: v_off_ini = -0.000001529 V, v_off_fin = -0.000001367 V 17:55:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035511 Vs 17:55:18 Voltage Offset Correction: v_off_ini = -0.000001501 V, v_off_fin = -0.000002273 V 17:55:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035178 Vs 17:55:19 Magnet Current for Main , Imag = 0.0083 A Vtrans = 0.000313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:55:19 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000315 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:55:26 Voltage Offset Correction: v_off_ini = -0.000001536 V, v_off_fin = -0.000001336 V 17:55:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035541 Vs 17:55:33 Voltage Offset Correction: v_off_ini = -0.000001461 V, v_off_fin = -0.000000896 V 17:55:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035924 Vs 17:55:33 Magnet Current for Main , Imag = 0.0084 A Vtrans = 0.000314 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:55:34 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000309 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:55:41 Voltage Offset Correction: v_off_ini = -0.000001542 V, v_off_fin = -0.000001961 V 17:55:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035567 Vs 17:55:47 Voltage Offset Correction: v_off_ini = -0.000001661 V, v_off_fin = -0.000001020 V 17:55:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035916 Vs 17:55:48 Magnet Current for Main , Imag = 0.0086 A Vtrans = 0.000316 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:55:48 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000313 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:55:55 Voltage Offset Correction: v_off_ini = -0.000001770 V, v_off_fin = -0.000001976 V 17:55:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035797 Vs 17:56:02 Voltage Offset Correction: v_off_ini = -0.000001849 V, v_off_fin = -0.000001844 V 17:56:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035564 Vs 17:56:02 Magnet Current for Main , Imag = 0.0090 A Vtrans = 0.000320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:56:03 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000313 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:56:09 Voltage Offset Correction: v_off_ini = -0.000001630 V, v_off_fin = -0.000001639 V 17:56:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035574 Vs 17:56:16 Voltage Offset Correction: v_off_ini = -0.000001686 V, v_off_fin = -0.000001793 V 17:56:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035389 Vs 17:56:17 Magnet Current for Main , Imag = 0.0089 A Vtrans = 0.000319 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:56:17 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000314 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:56:24 Voltage Offset Correction: v_off_ini = -0.000001208 V, v_off_fin = -0.000002124 V 17:56:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035645 Vs 17:56:30 Voltage Offset Correction: v_off_ini = -0.000001738 V, v_off_fin = -0.000001010 V 17:56:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035629 Vs 17:56:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035581 +- 0.000000144 Vs 17:56:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000035581 +- 0.000000144 Vs BL = 0.00355810 +- 0.00001437 Tm 17:56:34 Position moved: 0.000000 m 17:56:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00356 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00356 0.00001 0.00356 0.00000 17:56:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00356 0.00001 SL = 0.0035581 +- 0.0000144 Tm^2/m^n 17:56:34 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0035581 +- 0.0000144 Tm^2/m^n 17:56:37 Position moved: 0.000000 m 17:56:37 Magnet system Main current ramping to 0.0000 A... 17:56:47 Magnet system HTrim current ramping to -1.0000 A... 17:56:51 Magnet Current for Main , Imag = 0.0089 A Vtrans = 0.000319 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:56:52 Magnet Current for HTrim , Imag = -1.0003 A Vtrans = -0.166378 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:56:52 MAIN Voltage Measurement, V = 0.000561 V 17:56:53 Temperature Measurement, Probe Number = 0, T = 28.092000 C 17:56:54 Temperature Measurement, Probe Number = 1, T = 28.635000 C 17:56:54 Temperature Measurement, Probe Number = 2, T = 24.989000 C 17:56:54 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -1.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.09 P4 = Coil, Value = 28.64 P5 = Ambient Temp, Value = 24.99 17:56:54 Magnetic Field Measurement Measuring the magnet strength... 17:56:54 Integrated Voltage Measurement... 17:56:55 Magnet Current for Main , Imag = 0.0091 A Vtrans = 0.000321 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:56:56 Magnet Current for HTrim , Imag = -1.0003 A Vtrans = -0.166379 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:57:03 Voltage Offset Correction: v_off_ini = -0.000001675 V, v_off_fin = -0.000001562 V 17:57:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000006740 Vs 17:57:10 Voltage Offset Correction: v_off_ini = -0.000001797 V, v_off_fin = -0.000001948 V 17:57:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006657 Vs 17:57:10 Magnet Current for Main , Imag = 0.0089 A Vtrans = 0.000319 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:57:11 Magnet Current for HTrim , Imag = -1.0002 A Vtrans = -0.166376 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:57:18 Voltage Offset Correction: v_off_ini = -0.000001715 V, v_off_fin = -0.000001527 V 17:57:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000006756 Vs 17:57:24 Voltage Offset Correction: v_off_ini = -0.000001631 V, v_off_fin = -0.000001695 V 17:57:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006776 Vs 17:57:25 Magnet Current for Main , Imag = 0.0086 A Vtrans = 0.000316 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:57:26 Magnet Current for HTrim , Imag = -1.0003 A Vtrans = -0.166380 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:57:32 Voltage Offset Correction: v_off_ini = -0.000001747 V, v_off_fin = -0.000001781 V 17:57:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000006652 Vs 17:57:39 Voltage Offset Correction: v_off_ini = -0.000001673 V, v_off_fin = -0.000002073 V 17:57:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006638 Vs 17:57:39 Magnet Current for Main , Imag = 0.0084 A Vtrans = 0.000315 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:57:40 Magnet Current for HTrim , Imag = -1.0003 A Vtrans = -0.166379 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:57:47 Voltage Offset Correction: v_off_ini = -0.000002121 V, v_off_fin = -0.000002149 V 17:57:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000006765 Vs 17:57:53 Voltage Offset Correction: v_off_ini = -0.000001609 V, v_off_fin = -0.000001755 V 17:57:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006698 Vs 17:57:54 Magnet Current for Main , Imag = 0.0084 A Vtrans = 0.000314 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:57:55 Magnet Current for HTrim , Imag = -1.0003 A Vtrans = -0.166378 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:58:01 Voltage Offset Correction: v_off_ini = -0.000001819 V, v_off_fin = -0.000001913 V 17:58:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000006758 Vs 17:58:08 Voltage Offset Correction: v_off_ini = -0.000001633 V, v_off_fin = -0.000001833 V 17:58:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006696 Vs 17:58:08 Magnet Current for Main , Imag = 0.0086 A Vtrans = 0.000316 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:58:09 Magnet Current for HTrim , Imag = -1.0003 A Vtrans = -0.166378 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:58:16 Voltage Offset Correction: v_off_ini = -0.000001700 V, v_off_fin = -0.000001881 V 17:58:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000006713 Vs 17:58:22 Voltage Offset Correction: v_off_ini = -0.000001901 V, v_off_fin = -0.000001598 V 17:58:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006711 Vs 17:58:23 Magnet Current for Main , Imag = 0.0088 A Vtrans = 0.000318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:58:23 Magnet Current for HTrim , Imag = -1.0003 A Vtrans = -0.166377 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:58:30 Voltage Offset Correction: v_off_ini = -0.000001720 V, v_off_fin = -0.000001793 V 17:58:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000006777 Vs 17:58:36 Voltage Offset Correction: v_off_ini = -0.000001511 V, v_off_fin = -0.000001640 V 17:58:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000006665 Vs 17:58:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000006714 +- 0.000000034 Vs 17:58:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000006714 +- 0.000000034 Vs BL = 0.00067145 +- 0.00000343 Tm 17:58:40 Position moved: 0.000000 m 17:58:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00067 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00067 0.00000 0.00067 0.00000 17:58:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00067 0.00000 SL = 0.0006714 +- 0.0000034 Tm^2/m^n 17:58:40 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0006714 +- 0.0000034 Tm^2/m^n 17:58:43 Position moved: 0.000000 m 17:58:43 Magnet system Main current ramping to 0.0000 A... 17:58:53 Magnet system HTrim current ramping to -2.0000 A... 17:58:57 Magnet Current for Main , Imag = 0.0091 A Vtrans = 0.000321 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:58:58 Magnet Current for HTrim , Imag = -2.0017 A Vtrans = -0.333282 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:58:58 MAIN Voltage Measurement, V = 0.000568 V 17:58:59 Temperature Measurement, Probe Number = 0, T = 28.083000 C 17:59:00 Temperature Measurement, Probe Number = 1, T = 28.552000 C 17:59:00 Temperature Measurement, Probe Number = 2, T = 24.971000 C 17:59:00 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -2.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.08 P4 = Coil, Value = 28.55 P5 = Ambient Temp, Value = 24.97 17:59:00 Magnetic Field Measurement Measuring the magnet strength... 17:59:00 Integrated Voltage Measurement... 17:59:01 Magnet Current for Main , Imag = 0.0093 A Vtrans = 0.000323 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:59:02 Magnet Current for HTrim , Imag = -2.0017 A Vtrans = -0.333284 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:59:09 Voltage Offset Correction: v_off_ini = -0.000001620 V, v_off_fin = -0.000001512 V 17:59:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022209 Vs 17:59:16 Voltage Offset Correction: v_off_ini = -0.000001500 V, v_off_fin = -0.000001187 V 17:59:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000021941 Vs 17:59:16 Magnet Current for Main , Imag = 0.0091 A Vtrans = 0.000322 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:59:17 Magnet Current for HTrim , Imag = -2.0017 A Vtrans = -0.333282 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:59:24 Voltage Offset Correction: v_off_ini = -0.000001687 V, v_off_fin = -0.000001692 V 17:59:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022140 Vs 17:59:30 Voltage Offset Correction: v_off_ini = -0.000001628 V, v_off_fin = -0.000002063 V 17:59:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022243 Vs 17:59:31 Magnet Current for Main , Imag = 0.0089 A Vtrans = 0.000319 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:59:32 Magnet Current for HTrim , Imag = -2.0017 A Vtrans = -0.333282 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:59:38 Voltage Offset Correction: v_off_ini = -0.000001738 V, v_off_fin = -0.000001873 V 17:59:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022226 Vs 17:59:45 Voltage Offset Correction: v_off_ini = -0.000001637 V, v_off_fin = -0.000001371 V 17:59:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022097 Vs 17:59:46 Magnet Current for Main , Imag = 0.0084 A Vtrans = 0.000314 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 17:59:46 Magnet Current for HTrim , Imag = -2.0017 A Vtrans = -0.333283 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 17:59:53 Voltage Offset Correction: v_off_ini = -0.000001627 V, v_off_fin = -0.000001673 V 17:59:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022132 Vs 17:59:59 Voltage Offset Correction: v_off_ini = -0.000001647 V, v_off_fin = -0.000001379 V 17:59:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022006 Vs 18:00:00 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:00:01 Magnet Current for HTrim , Imag = -2.0017 A Vtrans = -0.333281 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:00:07 Voltage Offset Correction: v_off_ini = -0.000001848 V, v_off_fin = -0.000001959 V 18:00:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022289 Vs 18:00:14 Voltage Offset Correction: v_off_ini = -0.000001600 V, v_off_fin = -0.000001934 V 18:00:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022299 Vs 18:00:14 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:00:15 Magnet Current for HTrim , Imag = -2.0017 A Vtrans = -0.333282 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:00:22 Voltage Offset Correction: v_off_ini = -0.000001800 V, v_off_fin = -0.000001808 V 18:00:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022380 Vs 18:00:28 Voltage Offset Correction: v_off_ini = -0.000001661 V, v_off_fin = -0.000001921 V 18:00:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022410 Vs 18:00:29 Magnet Current for Main , Imag = 0.0083 A Vtrans = 0.000313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:00:29 Magnet Current for HTrim , Imag = -2.0017 A Vtrans = -0.333280 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:00:36 Voltage Offset Correction: v_off_ini = -0.000001590 V, v_off_fin = -0.000001575 V 18:00:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022202 Vs 18:00:43 Voltage Offset Correction: v_off_ini = -0.000001803 V, v_off_fin = -0.000002162 V 18:00:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000022301 Vs 18:00:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022205 +- 0.000000109 Vs 18:00:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000022205 +- 0.000000109 Vs BL = -0.00222054 +- 0.00001092 Tm 18:00:46 Position moved: 0.000000 m 18:00:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00222 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00222 0.00001 -0.00222 0.00000 18:00:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00222 0.00001 SL = -0.0022205 +- 0.0000109 Tm^2/m^n 18:00:46 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0022205 +- 0.0000109 Tm^2/m^n 18:00:49 Position moved: 0.000000 m 18:00:49 Magnet system Main current ramping to 0.0000 A... 18:00:59 Magnet system HTrim current ramping to -3.0000 A... 18:01:03 Magnet Current for Main , Imag = 0.0089 A Vtrans = 0.000320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:01:04 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500188 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:01:05 MAIN Voltage Measurement, V = 0.000557 V 18:01:05 Temperature Measurement, Probe Number = 0, T = 28.092000 C 18:01:06 Temperature Measurement, Probe Number = 1, T = 28.511000 C 18:01:06 Temperature Measurement, Probe Number = 2, T = 24.926000 C 18:01:06 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -3.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.09 P4 = Coil, Value = 28.51 P5 = Ambient Temp, Value = 24.93 18:01:06 Magnetic Field Measurement Measuring the magnet strength... 18:01:06 Integrated Voltage Measurement... 18:01:07 Magnet Current for Main , Imag = 0.0090 A Vtrans = 0.000321 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:01:08 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500186 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:01:15 Voltage Offset Correction: v_off_ini = -0.000001348 V, v_off_fin = -0.000001454 V 18:01:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000051022 Vs 18:01:22 Voltage Offset Correction: v_off_ini = -0.000001589 V, v_off_fin = -0.000000952 V 18:01:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000050608 Vs 18:01:22 Magnet Current for Main , Imag = 0.0089 A Vtrans = 0.000319 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:01:23 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500188 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:01:30 Voltage Offset Correction: v_off_ini = -0.000001670 V, v_off_fin = -0.000001716 V 18:01:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000050964 Vs 18:01:37 Voltage Offset Correction: v_off_ini = -0.000001589 V, v_off_fin = -0.000000651 V 18:01:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000050693 Vs 18:01:37 Magnet Current for Main , Imag = 0.0084 A Vtrans = 0.000315 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:01:38 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500186 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:01:44 Voltage Offset Correction: v_off_ini = -0.000001717 V, v_off_fin = -0.000001514 V 18:01:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000051048 Vs 18:01:51 Voltage Offset Correction: v_off_ini = -0.000001673 V, v_off_fin = -0.000002717 V 18:01:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000051609 Vs 18:01:52 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:01:52 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500184 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:01:59 Voltage Offset Correction: v_off_ini = -0.000001780 V, v_off_fin = -0.000001462 V 18:01:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000051226 Vs 18:02:06 Voltage Offset Correction: v_off_ini = -0.000001749 V, v_off_fin = -0.000002728 V 18:02:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000051588 Vs 18:02:06 Magnet Current for Main , Imag = 0.0084 A Vtrans = 0.000315 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:02:07 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500186 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:02:13 Voltage Offset Correction: v_off_ini = -0.000001933 V, v_off_fin = -0.000001975 V 18:02:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000050961 Vs 18:02:20 Voltage Offset Correction: v_off_ini = -0.000001631 V, v_off_fin = -0.000002609 V 18:02:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000051514 Vs 18:02:20 Magnet Current for Main , Imag = 0.0085 A Vtrans = 0.000315 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:02:21 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500183 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:02:28 Voltage Offset Correction: v_off_ini = -0.000001575 V, v_off_fin = -0.000001228 V 18:02:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000051040 Vs 18:02:34 Voltage Offset Correction: v_off_ini = -0.000001622 V, v_off_fin = -0.000001993 V 18:02:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000051180 Vs 18:02:35 Magnet Current for Main , Imag = 0.0087 A Vtrans = 0.000317 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:02:36 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500186 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:02:42 Voltage Offset Correction: v_off_ini = -0.000001601 V, v_off_fin = -0.000001739 V 18:02:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000050954 Vs 18:02:49 Voltage Offset Correction: v_off_ini = -0.000001771 V, v_off_fin = -0.000001138 V 18:02:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000050661 Vs 18:02:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000051076 +- 0.000000240 Vs 18:02:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000051076 +- 0.000000240 Vs BL = -0.00510762 +- 0.00002397 Tm 18:02:52 Position moved: 0.000000 m 18:02:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00511 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00511 0.00002 -0.00511 0.00000 18:02:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00511 0.00002 SL = -0.0051076 +- 0.0000240 Tm^2/m^n 18:02:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0051076 +- 0.0000240 Tm^2/m^n 18:02:55 Position moved: 0.000000 m 18:02:55 Magnet system Main current ramping to 0.0000 A... 18:03:05 Magnet system HTrim current ramping to -4.0000 A... 18:03:09 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:03:10 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666872 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:03:11 MAIN Voltage Measurement, V = 0.000551 V 18:03:11 Temperature Measurement, Probe Number = 0, T = 28.083000 C 18:03:12 Temperature Measurement, Probe Number = 1, T = 28.502000 C 18:03:12 Temperature Measurement, Probe Number = 2, T = 24.951000 C 18:03:12 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -4.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.08 P4 = Coil, Value = 28.50 P5 = Ambient Temp, Value = 24.95 18:03:12 Magnetic Field Measurement Measuring the magnet strength... 18:03:12 Integrated Voltage Measurement... 18:03:13 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:03:14 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666874 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:03:21 Voltage Offset Correction: v_off_ini = -0.000001810 V, v_off_fin = -0.000002187 V 18:03:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000079652 Vs 18:03:28 Voltage Offset Correction: v_off_ini = -0.000001599 V, v_off_fin = -0.000003030 V 18:03:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000080652 Vs 18:03:29 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:03:29 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666875 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:03:36 Voltage Offset Correction: v_off_ini = -0.000001651 V, v_off_fin = -0.000002590 V 18:03:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000079548 Vs 18:03:42 Voltage Offset Correction: v_off_ini = -0.000002015 V, v_off_fin = -0.000001249 V 18:03:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000079510 Vs 18:03:43 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:03:44 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666874 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:03:50 Voltage Offset Correction: v_off_ini = -0.000001847 V, v_off_fin = -0.000002023 V 18:03:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000079830 Vs 18:03:57 Voltage Offset Correction: v_off_ini = -0.000001835 V, v_off_fin = -0.000002610 V 18:03:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000080372 Vs 18:03:57 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:03:58 Magnet Current for HTrim , Imag = -4.0033 A Vtrans = -0.666876 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:04:05 Voltage Offset Correction: v_off_ini = -0.000001739 V, v_off_fin = -0.000001434 V 18:04:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000080092 Vs 18:04:11 Voltage Offset Correction: v_off_ini = -0.000001613 V, v_off_fin = -0.000001907 V 18:04:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000080089 Vs 18:04:12 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:04:12 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666876 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:04:19 Voltage Offset Correction: v_off_ini = -0.000001690 V, v_off_fin = -0.000001479 V 18:04:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000079955 Vs 18:04:26 Voltage Offset Correction: v_off_ini = -0.000001662 V, v_off_fin = -0.000002947 V 18:04:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000080533 Vs 18:04:26 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:04:27 Magnet Current for HTrim , Imag = -4.0033 A Vtrans = -0.666878 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:04:33 Voltage Offset Correction: v_off_ini = -0.000001616 V, v_off_fin = -0.000001545 V 18:04:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000080000 Vs 18:04:40 Voltage Offset Correction: v_off_ini = -0.000001752 V, v_off_fin = -0.000002393 V 18:04:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000080318 Vs 18:04:40 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:04:41 Magnet Current for HTrim , Imag = -4.0033 A Vtrans = -0.666877 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:04:48 Voltage Offset Correction: v_off_ini = -0.000001745 V, v_off_fin = -0.000002233 V 18:04:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000079697 Vs 18:04:54 Voltage Offset Correction: v_off_ini = -0.000001728 V, v_off_fin = -0.000003039 V 18:04:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000080697 Vs 18:04:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000080068 +- 0.000000225 Vs 18:04:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000080068 +- 0.000000225 Vs BL = -0.00800675 +- 0.00002252 Tm 18:04:58 Position moved: 0.000000 m 18:04:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00801 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00801 0.00002 -0.00801 0.00000 18:04:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00801 0.00002 SL = -0.0080068 +- 0.0000225 Tm^2/m^n 18:04:58 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0080068 +- 0.0000225 Tm^2/m^n 18:05:01 Position moved: 0.000000 m 18:05:01 Magnet system Main current ramping to 0.0000 A... 18:05:11 Magnet system HTrim current ramping to -5.0000 A... 18:05:15 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:05:16 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833765 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:05:16 MAIN Voltage Measurement, V = 0.000561 V 18:05:17 Temperature Measurement, Probe Number = 0, T = 28.065000 C 18:05:18 Temperature Measurement, Probe Number = 1, T = 28.487000 C 18:05:18 Temperature Measurement, Probe Number = 2, T = 24.960000 C 18:05:18 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -5.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.07 P4 = Coil, Value = 28.49 P5 = Ambient Temp, Value = 24.96 18:05:18 Magnetic Field Measurement Measuring the magnet strength... 18:05:18 Integrated Voltage Measurement... 18:05:19 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:05:20 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833767 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:05:27 Voltage Offset Correction: v_off_ini = -0.000001374 V, v_off_fin = -0.000000575 V 18:05:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000109299 Vs 18:05:34 Voltage Offset Correction: v_off_ini = -0.000001663 V, v_off_fin = 0.000000288 V 18:05:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000107881 Vs 18:05:34 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:05:35 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833769 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:05:42 Voltage Offset Correction: v_off_ini = -0.000001650 V, v_off_fin = -0.000002119 V 18:05:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000108769 Vs 18:05:48 Voltage Offset Correction: v_off_ini = -0.000001829 V, v_off_fin = -0.000003569 V 18:05:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000109754 Vs 18:05:49 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:05:49 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833770 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:05:56 Voltage Offset Correction: v_off_ini = -0.000001657 V, v_off_fin = -0.000001811 V 18:05:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000108725 Vs 18:06:03 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = 0.000000180 V 18:06:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000108054 Vs 18:06:03 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:06:04 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833768 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:06:10 Voltage Offset Correction: v_off_ini = -0.000001600 V, v_off_fin = -0.000002535 V 18:06:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000108421 Vs 18:06:17 Voltage Offset Correction: v_off_ini = -0.000001616 V, v_off_fin = -0.000000009 V 18:06:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000107955 Vs 18:06:18 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:06:18 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833769 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:06:25 Voltage Offset Correction: v_off_ini = -0.000001557 V, v_off_fin = -0.000001191 V 18:06:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000108979 Vs 18:06:31 Voltage Offset Correction: v_off_ini = -0.000001684 V, v_off_fin = -0.000003613 V 18:06:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000109677 Vs 18:06:32 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:06:33 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833770 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:06:39 Voltage Offset Correction: v_off_ini = -0.000001962 V, v_off_fin = -0.000002548 V 18:06:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000108410 Vs 18:06:46 Voltage Offset Correction: v_off_ini = -0.000001743 V, v_off_fin = -0.000004289 V 18:06:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000109932 Vs 18:06:47 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:06:47 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833770 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:06:54 Voltage Offset Correction: v_off_ini = -0.000001665 V, v_off_fin = -0.000001459 V 18:06:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000108931 Vs 18:07:00 Voltage Offset Correction: v_off_ini = -0.000001618 V, v_off_fin = -0.000000610 V 18:07:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000108340 Vs 18:07:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000108795 +- 0.000000421 Vs 18:07:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000108795 +- 0.000000421 Vs BL = -0.01087947 +- 0.00004214 Tm 18:07:04 Position moved: 0.000000 m 18:07:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01088 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01088 0.00004 -0.01088 0.00000 18:07:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01088 0.00004 SL = -0.0108795 +- 0.0000421 Tm^2/m^n 18:07:04 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0108795 +- 0.0000421 Tm^2/m^n 18:07:07 Position moved: 0.000000 m 18:07:07 Magnet system Main current ramping to 0.0000 A... 18:07:17 Magnet system HTrim current ramping to -6.0000 A... 18:07:21 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:07:22 Magnet Current for HTrim , Imag = -6.0059 A Vtrans = -1.000644 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:07:23 MAIN Voltage Measurement, V = 0.000553 V 18:07:23 Temperature Measurement, Probe Number = 0, T = 28.049000 C 18:07:24 Temperature Measurement, Probe Number = 1, T = 28.474000 C 18:07:24 Temperature Measurement, Probe Number = 2, T = 25.189000 C 18:07:24 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -6.01 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.05 P4 = Coil, Value = 28.47 P5 = Ambient Temp, Value = 25.19 18:07:24 Magnetic Field Measurement Measuring the magnet strength... 18:07:24 Integrated Voltage Measurement... 18:07:25 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:07:26 Magnet Current for HTrim , Imag = -6.0059 A Vtrans = -1.000645 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:07:33 Voltage Offset Correction: v_off_ini = -0.000001482 V, v_off_fin = -0.000000363 V 18:07:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000138454 Vs 18:07:40 Voltage Offset Correction: v_off_ini = -0.000001751 V, v_off_fin = -0.000004402 V 18:07:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000138861 Vs 18:07:41 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:07:41 Magnet Current for HTrim , Imag = -6.0059 A Vtrans = -1.000643 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:07:48 Voltage Offset Correction: v_off_ini = -0.000001894 V, v_off_fin = -0.000001741 V 18:07:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000137715 Vs 18:07:54 Voltage Offset Correction: v_off_ini = -0.000001994 V, v_off_fin = -0.000004187 V 18:07:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000139010 Vs 18:07:55 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:07:56 Magnet Current for HTrim , Imag = -6.0059 A Vtrans = -1.000648 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:08:02 Voltage Offset Correction: v_off_ini = -0.000001674 V, v_off_fin = -0.000001627 V 18:08:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000137832 Vs 18:08:09 Voltage Offset Correction: v_off_ini = -0.000001710 V, v_off_fin = -0.000000993 V 18:08:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000137329 Vs 18:08:10 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:08:10 Magnet Current for HTrim , Imag = -6.0059 A Vtrans = -1.000649 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:08:17 Voltage Offset Correction: v_off_ini = -0.000001814 V, v_off_fin = -0.000002124 V 18:08:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000137601 Vs 18:08:23 Voltage Offset Correction: v_off_ini = -0.000001783 V, v_off_fin = 0.000000904 V 18:08:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000136430 Vs 18:08:24 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:08:24 Magnet Current for HTrim , Imag = -6.0059 A Vtrans = -1.000648 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:08:31 Voltage Offset Correction: v_off_ini = -0.000001680 V, v_off_fin = -0.000000567 V 18:08:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000138312 Vs 18:08:37 Voltage Offset Correction: v_off_ini = -0.000001811 V, v_off_fin = 0.000000561 V 18:08:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000136591 Vs 18:08:38 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:08:39 Magnet Current for HTrim , Imag = -6.0059 A Vtrans = -1.000651 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:08:45 Voltage Offset Correction: v_off_ini = -0.000001893 V, v_off_fin = -0.000003047 V 18:08:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000137159 Vs 18:08:52 Voltage Offset Correction: v_off_ini = -0.000001792 V, v_off_fin = -0.000003943 V 18:08:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000139009 Vs 18:08:52 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:08:53 Magnet Current for HTrim , Imag = -6.0059 A Vtrans = -1.000653 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:09:00 Voltage Offset Correction: v_off_ini = -0.000001902 V, v_off_fin = -0.000002308 V 18:09:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000137304 Vs 18:09:06 Voltage Offset Correction: v_off_ini = -0.000002035 V, v_off_fin = -0.000001983 V 18:09:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000137910 Vs 18:09:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000137823 +- 0.000000528 Vs 18:09:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000137823 +- 0.000000528 Vs BL = -0.01378226 +- 0.00005280 Tm 18:09:10 Position moved: 0.000000 m 18:09:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01378 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01378 0.00005 -0.01378 0.00000 18:09:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01378 0.00005 SL = -0.0137823 +- 0.0000528 Tm^2/m^n 18:09:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0137823 +- 0.0000528 Tm^2/m^n 18:09:13 Position moved: 0.000000 m 18:09:13 Magnet system Main current ramping to 0.0000 A... 18:09:23 Magnet system HTrim current ramping to -5.0000 A... 18:09:27 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:09:28 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833771 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:09:28 MAIN Voltage Measurement, V = 0.000575 V 18:09:29 Temperature Measurement, Probe Number = 0, T = 28.062000 C 18:09:30 Temperature Measurement, Probe Number = 1, T = 28.452000 C 18:09:30 Temperature Measurement, Probe Number = 2, T = 25.236000 C 18:09:30 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -5.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.06 P4 = Coil, Value = 28.45 P5 = Ambient Temp, Value = 25.24 18:09:30 Magnetic Field Measurement Measuring the magnet strength... 18:09:30 Integrated Voltage Measurement... 18:09:31 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:09:31 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833770 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:09:39 Voltage Offset Correction: v_off_ini = -0.000001829 V, v_off_fin = -0.000001702 V 18:09:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000110029 Vs 18:09:46 Voltage Offset Correction: v_off_ini = -0.000001905 V, v_off_fin = -0.000002022 V 18:09:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000110187 Vs 18:09:46 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:09:47 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833770 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:09:53 Voltage Offset Correction: v_off_ini = -0.000001894 V, v_off_fin = -0.000001092 V 18:09:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000110408 Vs 18:10:00 Voltage Offset Correction: v_off_ini = -0.000001921 V, v_off_fin = -0.000003401 V 18:10:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000110734 Vs 18:10:01 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:10:01 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833771 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:10:08 Voltage Offset Correction: v_off_ini = -0.000001896 V, v_off_fin = -0.000001028 V 18:10:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000110339 Vs 18:10:15 Voltage Offset Correction: v_off_ini = -0.000001939 V, v_off_fin = -0.000001922 V 18:10:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000110000 Vs 18:10:15 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:10:16 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833769 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:10:22 Voltage Offset Correction: v_off_ini = -0.000002177 V, v_off_fin = -0.000002984 V 18:10:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000109570 Vs 18:10:29 Voltage Offset Correction: v_off_ini = -0.000002035 V, v_off_fin = -0.000001578 V 18:10:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000109860 Vs 18:10:30 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:10:30 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833770 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:10:37 Voltage Offset Correction: v_off_ini = -0.000001875 V, v_off_fin = -0.000000879 V 18:10:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000110503 Vs 18:10:43 Voltage Offset Correction: v_off_ini = -0.000001961 V, v_off_fin = -0.000001288 V 18:10:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000109560 Vs 18:10:44 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:10:45 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833770 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:10:51 Voltage Offset Correction: v_off_ini = -0.000001686 V, v_off_fin = -0.000000550 V 18:10:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000110526 Vs 18:10:58 Voltage Offset Correction: v_off_ini = -0.000002081 V, v_off_fin = -0.000003892 V 18:10:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000110956 Vs 18:10:58 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:10:59 Magnet Current for HTrim , Imag = -5.0046 A Vtrans = -0.833766 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:11:06 Voltage Offset Correction: v_off_ini = -0.000002004 V, v_off_fin = -0.000002980 V 18:11:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000109515 Vs 18:11:12 Voltage Offset Correction: v_off_ini = -0.000002125 V, v_off_fin = -0.000003958 V 18:11:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000111021 Vs 18:11:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000110229 +- 0.000000317 Vs 18:11:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000110229 +- 0.000000317 Vs BL = -0.01102292 +- 0.00003168 Tm 18:11:16 Position moved: 0.000000 m 18:11:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01102 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01102 0.00003 -0.01102 0.00000 18:11:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01102 0.00003 SL = -0.0110229 +- 0.0000317 Tm^2/m^n 18:11:16 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0110229 +- 0.0000317 Tm^2/m^n 18:11:19 Position moved: 0.000000 m 18:11:19 Magnet system Main current ramping to 0.0000 A... 18:11:29 Magnet system HTrim current ramping to -4.0000 A... 18:11:33 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:11:34 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666874 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:11:34 MAIN Voltage Measurement, V = 0.000575 V 18:11:35 Temperature Measurement, Probe Number = 0, T = 28.049000 C 18:11:36 Temperature Measurement, Probe Number = 1, T = 28.448000 C 18:11:36 Temperature Measurement, Probe Number = 2, T = 25.343000 C 18:11:36 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -4.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.05 P4 = Coil, Value = 28.45 P5 = Ambient Temp, Value = 25.34 18:11:36 Magnetic Field Measurement Measuring the magnet strength... 18:11:36 Integrated Voltage Measurement... 18:11:37 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:11:38 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666871 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:11:45 Voltage Offset Correction: v_off_ini = -0.000002062 V, v_off_fin = -0.000001492 V 18:11:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000082396 Vs 18:11:52 Voltage Offset Correction: v_off_ini = -0.000002150 V, v_off_fin = -0.000001475 V 18:11:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000081711 Vs 18:11:53 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:11:53 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666875 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:12:00 Voltage Offset Correction: v_off_ini = -0.000002067 V, v_off_fin = -0.000001536 V 18:12:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000082366 Vs 18:12:06 Voltage Offset Correction: v_off_ini = -0.000001945 V, v_off_fin = -0.000001664 V 18:12:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000081864 Vs 18:12:07 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:12:07 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666872 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:12:14 Voltage Offset Correction: v_off_ini = -0.000001926 V, v_off_fin = -0.000000955 V 18:12:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000082341 Vs 18:12:21 Voltage Offset Correction: v_off_ini = -0.000002080 V, v_off_fin = -0.000001151 V 18:12:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000081571 Vs 18:12:21 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:12:22 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666875 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:12:29 Voltage Offset Correction: v_off_ini = -0.000002358 V, v_off_fin = -0.000001880 V 18:12:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000082294 Vs 18:12:35 Voltage Offset Correction: v_off_ini = -0.000002224 V, v_off_fin = -0.000002474 V 18:12:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000082293 Vs 18:12:36 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:12:37 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666872 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:12:43 Voltage Offset Correction: v_off_ini = -0.000001957 V, v_off_fin = -0.000002230 V 18:12:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000082004 Vs 18:12:50 Voltage Offset Correction: v_off_ini = -0.000002151 V, v_off_fin = -0.000003728 V 18:12:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000082778 Vs 18:12:50 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:12:51 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666870 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:12:57 Voltage Offset Correction: v_off_ini = -0.000001957 V, v_off_fin = -0.000001550 V 18:12:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000082374 Vs 18:13:04 Voltage Offset Correction: v_off_ini = -0.000001889 V, v_off_fin = -0.000001733 V 18:13:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000082110 Vs 18:13:04 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:13:05 Magnet Current for HTrim , Imag = -4.0032 A Vtrans = -0.666871 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:13:12 Voltage Offset Correction: v_off_ini = -0.000002072 V, v_off_fin = -0.000001844 V 18:13:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000082150 Vs 18:13:18 Voltage Offset Correction: v_off_ini = -0.000002059 V, v_off_fin = -0.000002157 V 18:13:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000082046 Vs 18:13:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000082164 +- 0.000000140 Vs 18:13:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000082164 +- 0.000000140 Vs BL = -0.00821641 +- 0.00001397 Tm 18:13:22 Position moved: 0.000000 m 18:13:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00822 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00822 0.00001 -0.00822 0.00000 18:13:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00822 0.00001 SL = -0.0082164 +- 0.0000140 Tm^2/m^n 18:13:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0082164 +- 0.0000140 Tm^2/m^n 18:13:25 Position moved: 0.000000 m 18:13:25 Magnet system Main current ramping to 0.0000 A... 18:13:35 Magnet system HTrim current ramping to -3.0000 A... 18:13:39 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:13:40 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500177 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:13:40 MAIN Voltage Measurement, V = 0.000586 V 18:13:41 Temperature Measurement, Probe Number = 0, T = 28.039000 C 18:13:42 Temperature Measurement, Probe Number = 1, T = 28.460000 C 18:13:42 Temperature Measurement, Probe Number = 2, T = 25.216000 C 18:13:42 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -3.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.04 P4 = Coil, Value = 28.46 P5 = Ambient Temp, Value = 25.22 18:13:42 Magnetic Field Measurement Measuring the magnet strength... 18:13:42 Integrated Voltage Measurement... 18:13:43 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:13:44 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500179 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:13:51 Voltage Offset Correction: v_off_ini = -0.000002132 V, v_off_fin = -0.000001869 V 18:13:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000054235 Vs 18:13:58 Voltage Offset Correction: v_off_ini = -0.000002034 V, v_off_fin = -0.000001174 V 18:13:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000053660 Vs 18:13:58 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:13:59 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500178 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:14:05 Voltage Offset Correction: v_off_ini = -0.000002006 V, v_off_fin = -0.000002468 V 18:14:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000053878 Vs 18:14:12 Voltage Offset Correction: v_off_ini = -0.000002080 V, v_off_fin = -0.000001680 V 18:14:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000053805 Vs 18:14:13 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:14:13 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500180 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:14:20 Voltage Offset Correction: v_off_ini = -0.000001955 V, v_off_fin = -0.000002059 V 18:14:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000053869 Vs 18:14:26 Voltage Offset Correction: v_off_ini = -0.000002010 V, v_off_fin = -0.000002139 V 18:14:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000054102 Vs 18:14:27 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:14:28 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500177 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:14:34 Voltage Offset Correction: v_off_ini = -0.000001952 V, v_off_fin = -0.000001654 V 18:14:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000054088 Vs 18:14:41 Voltage Offset Correction: v_off_ini = -0.000001788 V, v_off_fin = -0.000001864 V 18:14:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000054052 Vs 18:14:42 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:14:42 Magnet Current for HTrim , Imag = -3.0030 A Vtrans = -0.500171 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:14:49 Voltage Offset Correction: v_off_ini = -0.000001672 V, v_off_fin = -0.000001585 V 18:14:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000054154 Vs 18:14:55 Voltage Offset Correction: v_off_ini = -0.000001871 V, v_off_fin = -0.000002629 V 18:14:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000054448 Vs 18:14:56 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:14:57 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500176 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:15:03 Voltage Offset Correction: v_off_ini = -0.000002088 V, v_off_fin = -0.000001984 V 18:15:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000054346 Vs 18:15:10 Voltage Offset Correction: v_off_ini = -0.000001860 V, v_off_fin = -0.000000618 V 18:15:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000053680 Vs 18:15:10 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:15:11 Magnet Current for HTrim , Imag = -3.0031 A Vtrans = -0.500176 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:15:18 Voltage Offset Correction: v_off_ini = -0.000001942 V, v_off_fin = -0.000001309 V 18:15:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000054077 Vs 18:15:24 Voltage Offset Correction: v_off_ini = -0.000001686 V, v_off_fin = -0.000001971 V 18:15:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000054078 Vs 18:15:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000054034 +- 0.000000132 Vs 18:15:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000054034 +- 0.000000132 Vs BL = -0.00540338 +- 0.00001319 Tm 18:15:28 Position moved: 0.000000 m 18:15:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00540 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00540 0.00001 -0.00540 0.00000 18:15:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00540 0.00001 SL = -0.0054034 +- 0.0000132 Tm^2/m^n 18:15:28 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0054034 +- 0.0000132 Tm^2/m^n 18:15:31 Position moved: 0.000000 m 18:15:31 Magnet system Main current ramping to 0.0000 A... 18:15:41 Magnet system HTrim current ramping to -2.0000 A... 18:15:45 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:15:46 Magnet Current for HTrim , Imag = -2.0016 A Vtrans = -0.333271 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:15:46 MAIN Voltage Measurement, V = 0.000575 V 18:15:47 Temperature Measurement, Probe Number = 0, T = 28.040000 C 18:15:48 Temperature Measurement, Probe Number = 1, T = 28.460000 C 18:15:48 Temperature Measurement, Probe Number = 2, T = 25.059000 C 18:15:48 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -2.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.04 P4 = Coil, Value = 28.46 P5 = Ambient Temp, Value = 25.06 18:15:48 Magnetic Field Measurement Measuring the magnet strength... 18:15:48 Integrated Voltage Measurement... 18:15:49 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:15:50 Magnet Current for HTrim , Imag = -2.0016 A Vtrans = -0.333273 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:15:57 Voltage Offset Correction: v_off_ini = -0.000001869 V, v_off_fin = -0.000001551 V 18:15:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000025992 Vs 18:16:04 Voltage Offset Correction: v_off_ini = -0.000002117 V, v_off_fin = -0.000002416 V 18:16:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000026002 Vs 18:16:05 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:16:05 Magnet Current for HTrim , Imag = -2.0016 A Vtrans = -0.333273 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:16:12 Voltage Offset Correction: v_off_ini = -0.000001711 V, v_off_fin = -0.000001538 V 18:16:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000025967 Vs 18:16:18 Voltage Offset Correction: v_off_ini = -0.000002024 V, v_off_fin = -0.000001942 V 18:16:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000025555 Vs 18:16:19 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:16:20 Magnet Current for HTrim , Imag = -2.0016 A Vtrans = -0.333272 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:16:26 Voltage Offset Correction: v_off_ini = -0.000001826 V, v_off_fin = -0.000001964 V 18:16:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000025832 Vs 18:16:33 Voltage Offset Correction: v_off_ini = -0.000001742 V, v_off_fin = -0.000002127 V 18:16:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000026035 Vs 18:16:33 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:16:34 Magnet Current for HTrim , Imag = -2.0016 A Vtrans = -0.333272 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:16:41 Voltage Offset Correction: v_off_ini = -0.000001744 V, v_off_fin = -0.000001418 V 18:16:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000025902 Vs 18:16:47 Voltage Offset Correction: v_off_ini = -0.000001645 V, v_off_fin = -0.000001891 V 18:16:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000025877 Vs 18:16:48 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:16:49 Magnet Current for HTrim , Imag = -2.0016 A Vtrans = -0.333272 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:16:55 Voltage Offset Correction: v_off_ini = -0.000001986 V, v_off_fin = -0.000002033 V 18:16:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000025902 Vs 18:17:02 Voltage Offset Correction: v_off_ini = -0.000001827 V, v_off_fin = -0.000001467 V 18:17:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000025625 Vs 18:17:02 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:17:03 Magnet Current for HTrim , Imag = -2.0016 A Vtrans = -0.333271 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:17:10 Voltage Offset Correction: v_off_ini = -0.000002032 V, v_off_fin = -0.000001911 V 18:17:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000025865 Vs 18:17:16 Voltage Offset Correction: v_off_ini = -0.000001936 V, v_off_fin = -0.000002000 V 18:17:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000025904 Vs 18:17:17 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:17:18 Magnet Current for HTrim , Imag = -2.0016 A Vtrans = -0.333271 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:17:24 Voltage Offset Correction: v_off_ini = -0.000001869 V, v_off_fin = -0.000001584 V 18:17:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000026005 Vs 18:17:31 Voltage Offset Correction: v_off_ini = -0.000001917 V, v_off_fin = -0.000002573 V 18:17:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000026092 Vs 18:17:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000025897 +- 0.000000101 Vs 18:17:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000025897 +- 0.000000101 Vs BL = -0.00258968 +- 0.00001005 Tm 18:17:34 Position moved: 0.000000 m 18:17:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00259 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00259 0.00001 -0.00259 0.00000 18:17:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00259 0.00001 SL = -0.0025897 +- 0.0000101 Tm^2/m^n 18:17:34 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0025897 +- 0.0000101 Tm^2/m^n 18:17:37 Position moved: 0.000000 m 18:17:37 Magnet system Main current ramping to 0.0000 A... 18:17:47 Magnet system HTrim current ramping to -1.0000 A... 18:17:51 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:17:52 Magnet Current for HTrim , Imag = -1.0002 A Vtrans = -0.166364 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:17:53 MAIN Voltage Measurement, V = 0.000588 V 18:17:53 Temperature Measurement, Probe Number = 0, T = 28.025000 C 18:17:54 Temperature Measurement, Probe Number = 1, T = 28.466000 C 18:17:54 Temperature Measurement, Probe Number = 2, T = 25.094000 C 18:17:54 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -1.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.02 P4 = Coil, Value = 28.47 P5 = Ambient Temp, Value = 25.09 18:17:54 Magnetic Field Measurement Measuring the magnet strength... 18:17:54 Integrated Voltage Measurement... 18:17:55 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:17:56 Magnet Current for HTrim , Imag = -1.0002 A Vtrans = -0.166365 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:18:03 Voltage Offset Correction: v_off_ini = -0.000002059 V, v_off_fin = -0.000001947 V 18:18:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002363 Vs 18:18:10 Voltage Offset Correction: v_off_ini = -0.000001858 V, v_off_fin = -0.000001845 V 18:18:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002386 Vs 18:18:10 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:18:11 Magnet Current for HTrim , Imag = -1.0002 A Vtrans = -0.166365 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:18:18 Voltage Offset Correction: v_off_ini = -0.000001786 V, v_off_fin = -0.000001925 V 18:18:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002332 Vs 18:18:24 Voltage Offset Correction: v_off_ini = -0.000001865 V, v_off_fin = -0.000001750 V 18:18:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002270 Vs 18:18:25 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:18:26 Magnet Current for HTrim , Imag = -1.0002 A Vtrans = -0.166368 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:18:32 Voltage Offset Correction: v_off_ini = -0.000001874 V, v_off_fin = -0.000001674 V 18:18:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002323 Vs 18:18:39 Voltage Offset Correction: v_off_ini = -0.000002080 V, v_off_fin = -0.000001991 V 18:18:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002311 Vs 18:18:40 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:18:40 Magnet Current for HTrim , Imag = -1.0002 A Vtrans = -0.166367 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:18:47 Voltage Offset Correction: v_off_ini = -0.000002099 V, v_off_fin = -0.000002164 V 18:18:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002432 Vs 18:18:53 Voltage Offset Correction: v_off_ini = -0.000001866 V, v_off_fin = -0.000001920 V 18:18:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002364 Vs 18:18:54 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:18:55 Magnet Current for HTrim , Imag = -1.0002 A Vtrans = -0.166364 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:19:01 Voltage Offset Correction: v_off_ini = -0.000001907 V, v_off_fin = -0.000002186 V 18:19:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002201 Vs 18:19:08 Voltage Offset Correction: v_off_ini = -0.000001939 V, v_off_fin = -0.000001775 V 18:19:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002361 Vs 18:19:09 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:19:09 Magnet Current for HTrim , Imag = -1.0002 A Vtrans = -0.166365 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:19:16 Voltage Offset Correction: v_off_ini = -0.000001952 V, v_off_fin = -0.000001861 V 18:19:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002325 Vs 18:19:22 Voltage Offset Correction: v_off_ini = -0.000001771 V, v_off_fin = -0.000001708 V 18:19:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002333 Vs 18:19:23 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:19:24 Magnet Current for HTrim , Imag = -1.0002 A Vtrans = -0.166366 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:19:30 Voltage Offset Correction: v_off_ini = -0.000002035 V, v_off_fin = -0.000002312 V 18:19:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002397 Vs 18:19:37 Voltage Offset Correction: v_off_ini = -0.000002191 V, v_off_fin = -0.000002149 V 18:19:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002467 Vs 18:19:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002348 +- 0.000000051 Vs 18:19:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000002348 +- 0.000000051 Vs BL = 0.00023475 +- 0.00000511 Tm 18:19:41 Position moved: 0.000000 m 18:19:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00023 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00023 0.00001 0.00023 0.00000 18:19:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00023 0.00001 SL = 0.0002348 +- 0.0000051 Tm^2/m^n 18:19:41 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0002348 +- 0.0000051 Tm^2/m^n 18:19:44 Position moved: 0.000000 m 18:19:44 Magnet system Main current ramping to 0.0000 A... 18:19:54 Magnet system HTrim current ramping to 0.0000 A... 18:19:58 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:19:58 Magnet Current for HTrim , Imag = -0.0000 A Vtrans = 0.000324 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:19:59 MAIN Voltage Measurement, V = 0.000564 V 18:20:00 Temperature Measurement, Probe Number = 0, T = 28.024000 C 18:20:00 Temperature Measurement, Probe Number = 1, T = 28.452000 C 18:20:01 Temperature Measurement, Probe Number = 2, T = 25.049000 C 18:20:01 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -0.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.02 P4 = Coil, Value = 28.45 P5 = Ambient Temp, Value = 25.05 18:20:01 Magnetic Field Measurement Measuring the magnet strength... 18:20:01 Integrated Voltage Measurement... 18:20:02 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:20:02 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000322 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:20:10 Voltage Offset Correction: v_off_ini = -0.000001970 V, v_off_fin = -0.000002090 V 18:20:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030592 Vs 18:20:16 Voltage Offset Correction: v_off_ini = -0.000001859 V, v_off_fin = -0.000002591 V 18:20:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000030482 Vs 18:20:17 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:20:18 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000318 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:20:24 Voltage Offset Correction: v_off_ini = -0.000002013 V, v_off_fin = -0.000002216 V 18:20:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030464 Vs 18:20:31 Voltage Offset Correction: v_off_ini = -0.000002127 V, v_off_fin = -0.000002748 V 18:20:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000030329 Vs 18:20:31 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:20:32 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000318 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:20:39 Voltage Offset Correction: v_off_ini = -0.000001927 V, v_off_fin = -0.000002405 V 18:20:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030689 Vs 18:20:45 Voltage Offset Correction: v_off_ini = -0.000002171 V, v_off_fin = -0.000002343 V 18:20:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000030772 Vs 18:20:46 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:20:47 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000316 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:20:53 Voltage Offset Correction: v_off_ini = -0.000001802 V, v_off_fin = -0.000002453 V 18:20:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030577 Vs 18:21:00 Voltage Offset Correction: v_off_ini = -0.000001731 V, v_off_fin = -0.000001485 V 18:21:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000030839 Vs 18:21:00 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:21:01 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000319 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:21:07 Voltage Offset Correction: v_off_ini = -0.000001966 V, v_off_fin = -0.000001982 V 18:21:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030470 Vs 18:21:14 Voltage Offset Correction: v_off_ini = -0.000001990 V, v_off_fin = -0.000002250 V 18:21:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000030354 Vs 18:21:15 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:21:15 Magnet Current for HTrim , Imag = -0.0000 A Vtrans = 0.000330 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:21:22 Voltage Offset Correction: v_off_ini = -0.000002281 V, v_off_fin = -0.000001852 V 18:21:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030284 Vs 18:21:28 Voltage Offset Correction: v_off_ini = -0.000002113 V, v_off_fin = -0.000002353 V 18:21:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000030312 Vs 18:21:29 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:21:30 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000314 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:21:36 Voltage Offset Correction: v_off_ini = -0.000002078 V, v_off_fin = -0.000001785 V 18:21:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030665 Vs 18:21:43 Voltage Offset Correction: v_off_ini = -0.000002351 V, v_off_fin = -0.000001906 V 18:21:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000030389 Vs 18:21:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000030516 +- 0.000000149 Vs 18:21:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000030516 +- 0.000000149 Vs BL = 0.00305156 +- 0.00001493 Tm 18:21:47 Position moved: 0.000000 m 18:21:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00305 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00305 0.00001 0.00305 0.00000 18:21:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00305 0.00001 SL = 0.0030516 +- 0.0000149 Tm^2/m^n 18:21:47 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0030516 +- 0.0000149 Tm^2/m^n 18:21:49 Position moved: 0.000000 m 18:21:49 Magnet system Main current ramping to 0.0000 A... 18:22:00 Magnet system HTrim current ramping to 1.0000 A... 18:22:04 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:22:04 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166920 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:22:05 MAIN Voltage Measurement, V = 0.000563 V 18:22:06 Temperature Measurement, Probe Number = 0, T = 28.032000 C 18:22:06 Temperature Measurement, Probe Number = 1, T = 28.450000 C 18:22:07 Temperature Measurement, Probe Number = 2, T = 25.005000 C 18:22:07 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = 1.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.03 P4 = Coil, Value = 28.45 P5 = Ambient Temp, Value = 25.00 18:22:07 Magnetic Field Measurement Measuring the magnet strength... 18:22:07 Integrated Voltage Measurement... 18:22:07 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:22:08 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166919 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:22:16 Voltage Offset Correction: v_off_ini = -0.000002097 V, v_off_fin = -0.000001613 V 18:22:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000058539 Vs 18:22:22 Voltage Offset Correction: v_off_ini = -0.000001966 V, v_off_fin = -0.000001269 V 18:22:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000059242 Vs 18:22:23 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:22:24 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166919 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:22:30 Voltage Offset Correction: v_off_ini = -0.000001955 V, v_off_fin = -0.000002148 V 18:22:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000058772 Vs 18:22:37 Voltage Offset Correction: v_off_ini = -0.000002064 V, v_off_fin = -0.000002529 V 18:22:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000058531 Vs 18:22:37 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:22:38 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166917 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:22:45 Voltage Offset Correction: v_off_ini = -0.000002091 V, v_off_fin = -0.000001491 V 18:22:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000058476 Vs 18:22:51 Voltage Offset Correction: v_off_ini = -0.000002036 V, v_off_fin = -0.000000893 V 18:22:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000059268 Vs 18:22:52 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:22:53 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166915 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:22:59 Voltage Offset Correction: v_off_ini = -0.000002050 V, v_off_fin = -0.000001453 V 18:22:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000058546 Vs 18:23:06 Voltage Offset Correction: v_off_ini = -0.000002050 V, v_off_fin = -0.000000962 V 18:23:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000059189 Vs 18:23:06 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:23:07 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166914 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:23:14 Voltage Offset Correction: v_off_ini = -0.000001915 V, v_off_fin = -0.000002171 V 18:23:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000058943 Vs 18:23:20 Voltage Offset Correction: v_off_ini = -0.000002151 V, v_off_fin = -0.000001284 V 18:23:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000059206 Vs 18:23:21 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:23:22 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166917 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:23:28 Voltage Offset Correction: v_off_ini = -0.000001546 V, v_off_fin = -0.000002463 V 18:23:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000059006 Vs 18:23:35 Voltage Offset Correction: v_off_ini = -0.000001881 V, v_off_fin = -0.000000437 V 18:23:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000059411 Vs 18:23:35 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:23:36 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166917 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:23:42 Voltage Offset Correction: v_off_ini = -0.000001856 V, v_off_fin = -0.000001412 V 18:23:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000058465 Vs 18:23:49 Voltage Offset Correction: v_off_ini = -0.000001754 V, v_off_fin = -0.000000932 V 18:23:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000059348 Vs 18:23:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000058924 +- 0.000000163 Vs 18:23:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000058924 +- 0.000000163 Vs BL = 0.00589244 +- 0.00001627 Tm 18:23:53 Position moved: 0.000000 m 18:23:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00589 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00589 0.00002 0.00589 0.00000 18:23:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00589 0.00002 SL = 0.0058924 +- 0.0000163 Tm^2/m^n 18:23:53 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0058924 +- 0.0000163 Tm^2/m^n 18:23:55 Position moved: 0.000000 m 18:23:55 Magnet system Main current ramping to 0.0000 A... 18:24:06 Magnet system HTrim current ramping to 2.0000 A... 18:24:10 Magnet Current for Main , Imag = 0.0083 A Vtrans = 0.000313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:24:10 Magnet Current for HTrim , Imag = 2.0007 A Vtrans = 0.333777 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:24:11 MAIN Voltage Measurement, V = 0.000588 V 18:24:12 Temperature Measurement, Probe Number = 0, T = 28.369000 C 18:24:12 Temperature Measurement, Probe Number = 1, T = 28.472000 C 18:24:13 Temperature Measurement, Probe Number = 2, T = 24.869000 C 18:24:13 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = 2.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.37 P4 = Coil, Value = 28.47 P5 = Ambient Temp, Value = 24.87 18:24:13 Magnetic Field Measurement Measuring the magnet strength... 18:24:13 Integrated Voltage Measurement... 18:24:13 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:24:14 Magnet Current for HTrim , Imag = 2.0007 A Vtrans = 0.333776 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:24:22 Voltage Offset Correction: v_off_ini = -0.000001656 V, v_off_fin = -0.000002707 V 18:24:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000087558 Vs 18:24:28 Voltage Offset Correction: v_off_ini = -0.000001699 V, v_off_fin = -0.000001879 V 18:24:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000087038 Vs 18:24:29 Magnet Current for Main , Imag = 0.0083 A Vtrans = 0.000313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:24:30 Magnet Current for HTrim , Imag = 2.0007 A Vtrans = 0.333775 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:24:36 Voltage Offset Correction: v_off_ini = -0.000001842 V, v_off_fin = -0.000002629 V 18:24:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000087447 Vs 18:24:43 Voltage Offset Correction: v_off_ini = -0.000001671 V, v_off_fin = 0.000000094 V 18:24:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000088004 Vs 18:24:43 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:24:44 Magnet Current for HTrim , Imag = 2.0007 A Vtrans = 0.333775 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:24:51 Voltage Offset Correction: v_off_ini = -0.000001527 V, v_off_fin = -0.000001615 V 18:24:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000087087 Vs 18:24:57 Voltage Offset Correction: v_off_ini = -0.000001889 V, v_off_fin = -0.000003475 V 18:24:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000086375 Vs 18:24:58 Magnet Current for Main , Imag = 0.0083 A Vtrans = 0.000313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:24:59 Magnet Current for HTrim , Imag = 2.0006 A Vtrans = 0.333773 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:25:05 Voltage Offset Correction: v_off_ini = -0.000001815 V, v_off_fin = -0.000001863 V 18:25:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000086990 Vs 18:25:12 Voltage Offset Correction: v_off_ini = -0.000001651 V, v_off_fin = -0.000000983 V 18:25:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000087497 Vs 18:25:12 Magnet Current for Main , Imag = 0.0085 A Vtrans = 0.000315 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:25:13 Magnet Current for HTrim , Imag = 2.0007 A Vtrans = 0.333774 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:25:19 Voltage Offset Correction: v_off_ini = -0.000001887 V, v_off_fin = -0.000002386 V 18:25:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000087452 Vs 18:25:26 Voltage Offset Correction: v_off_ini = -0.000001688 V, v_off_fin = -0.000001337 V 18:25:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000087371 Vs 18:25:27 Magnet Current for Main , Imag = 0.0085 A Vtrans = 0.000316 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:25:27 Magnet Current for HTrim , Imag = 2.0006 A Vtrans = 0.333771 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:25:34 Voltage Offset Correction: v_off_ini = -0.000001846 V, v_off_fin = -0.000000727 V 18:25:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000086636 Vs 18:25:41 Voltage Offset Correction: v_off_ini = -0.000001848 V, v_off_fin = -0.000000661 V 18:25:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000087739 Vs 18:25:41 Magnet Current for Main , Imag = 0.0087 A Vtrans = 0.000317 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:25:42 Magnet Current for HTrim , Imag = 2.0006 A Vtrans = 0.333773 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:25:48 Voltage Offset Correction: v_off_ini = -0.000001734 V, v_off_fin = -0.000002158 V 18:25:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000087331 Vs 18:25:55 Voltage Offset Correction: v_off_ini = -0.000001692 V, v_off_fin = -0.000001161 V 18:25:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000087314 Vs 18:25:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000087274 +- 0.000000275 Vs 18:25:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000087274 +- 0.000000275 Vs BL = 0.00872743 +- 0.00002750 Tm 18:25:59 Position moved: 0.000000 m 18:25:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00873 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00873 0.00003 0.00873 0.00000 18:25:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00873 0.00003 SL = 0.0087274 +- 0.0000275 Tm^2/m^n 18:25:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0087274 +- 0.0000275 Tm^2/m^n 18:26:02 Position moved: 0.000000 m 18:26:02 Magnet system Main current ramping to 0.0000 A... 18:26:12 Magnet system HTrim current ramping to 3.0000 A... 18:26:16 Magnet Current for Main , Imag = 0.0085 A Vtrans = 0.000316 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:26:17 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500668 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:26:17 MAIN Voltage Measurement, V = 0.000571 V 18:26:18 Temperature Measurement, Probe Number = 0, T = 28.833000 C 18:26:18 Temperature Measurement, Probe Number = 1, T = 28.776000 C 18:26:19 Temperature Measurement, Probe Number = 2, T = 24.845000 C 18:26:19 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = 3.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.83 P4 = Coil, Value = 28.78 P5 = Ambient Temp, Value = 24.84 18:26:19 Magnetic Field Measurement Measuring the magnet strength... 18:26:19 Integrated Voltage Measurement... 18:26:20 Magnet Current for Main , Imag = 0.0088 A Vtrans = 0.000318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:26:20 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500669 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:26:28 Voltage Offset Correction: v_off_ini = -0.000001729 V, v_off_fin = -0.000000469 V 18:26:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000114699 Vs 18:26:35 Voltage Offset Correction: v_off_ini = -0.000001695 V, v_off_fin = -0.000000066 V 18:26:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000116203 Vs 18:26:35 Magnet Current for Main , Imag = 0.0083 A Vtrans = 0.000313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:26:36 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500667 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:26:43 Voltage Offset Correction: v_off_ini = -0.000001552 V, v_off_fin = -0.000002392 V 18:26:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000115911 Vs 18:26:49 Voltage Offset Correction: v_off_ini = -0.000001694 V, v_off_fin = -0.000001471 V 18:26:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000115585 Vs 18:26:50 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:26:50 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500668 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:26:57 Voltage Offset Correction: v_off_ini = -0.000001663 V, v_off_fin = -0.000000808 V 18:26:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000114979 Vs 18:27:04 Voltage Offset Correction: v_off_ini = -0.000001963 V, v_off_fin = -0.000001250 V 18:27:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000116235 Vs 18:27:04 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:27:05 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500667 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:27:12 Voltage Offset Correction: v_off_ini = -0.000001802 V, v_off_fin = -0.000001147 V 18:27:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000114911 Vs 18:27:18 Voltage Offset Correction: v_off_ini = -0.000001844 V, v_off_fin = -0.000002310 V 18:27:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000115076 Vs 18:27:19 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:27:19 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500669 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:27:26 Voltage Offset Correction: v_off_ini = -0.000001901 V, v_off_fin = -0.000000899 V 18:27:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000114944 Vs 18:27:33 Voltage Offset Correction: v_off_ini = -0.000001898 V, v_off_fin = -0.000001425 V 18:27:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000115712 Vs 18:27:33 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:27:34 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500666 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:27:41 Voltage Offset Correction: v_off_ini = -0.000001983 V, v_off_fin = -0.000001974 V 18:27:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000115291 Vs 18:27:47 Voltage Offset Correction: v_off_ini = -0.000001994 V, v_off_fin = -0.000001402 V 18:27:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000115976 Vs 18:27:48 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:27:48 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500669 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:27:55 Voltage Offset Correction: v_off_ini = -0.000001972 V, v_off_fin = -0.000001817 V 18:27:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000115382 Vs 18:28:01 Voltage Offset Correction: v_off_ini = -0.000002008 V, v_off_fin = -0.000001620 V 18:28:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000115416 Vs 18:28:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000115451 +- 0.000000231 Vs 18:28:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000115451 +- 0.000000231 Vs BL = 0.01154514 +- 0.00002308 Tm 18:28:05 Position moved: 0.000000 m 18:28:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01155 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.01155 0.00002 0.01155 0.00000 18:28:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01155 0.00002 SL = 0.0115451 +- 0.0000231 Tm^2/m^n 18:28:05 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0115451 +- 0.0000231 Tm^2/m^n 18:28:08 Position moved: 0.000000 m 18:28:08 Magnet system Main current ramping to 0.0000 A... 18:28:18 Magnet system HTrim current ramping to 4.0000 A... 18:28:22 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:28:23 Magnet Current for HTrim , Imag = 4.0017 A Vtrans = 0.667287 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:28:24 MAIN Voltage Measurement, V = 0.000566 V 18:28:24 Temperature Measurement, Probe Number = 0, T = 28.181000 C 18:28:25 Temperature Measurement, Probe Number = 1, T = 28.565000 C 18:28:25 Temperature Measurement, Probe Number = 2, T = 24.872000 C 18:28:25 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = 4.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.18 P4 = Coil, Value = 28.57 P5 = Ambient Temp, Value = 24.87 18:28:25 Magnetic Field Measurement Measuring the magnet strength... 18:28:25 Integrated Voltage Measurement... 18:28:26 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:28:27 Magnet Current for HTrim , Imag = 4.0017 A Vtrans = 0.667287 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:28:34 Voltage Offset Correction: v_off_ini = -0.000001841 V, v_off_fin = -0.000000683 V 18:28:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000142993 Vs 18:28:41 Voltage Offset Correction: v_off_ini = -0.000002031 V, v_off_fin = -0.000002641 V 18:28:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000143504 Vs 18:28:41 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:28:42 Magnet Current for HTrim , Imag = 4.0017 A Vtrans = 0.667286 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:28:49 Voltage Offset Correction: v_off_ini = -0.000001916 V, v_off_fin = -0.000003495 V 18:28:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000144537 Vs 18:28:55 Voltage Offset Correction: v_off_ini = -0.000001956 V, v_off_fin = -0.000004018 V 18:28:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000142666 Vs 18:28:56 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:28:57 Magnet Current for HTrim , Imag = 4.0017 A Vtrans = 0.667288 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:29:03 Voltage Offset Correction: v_off_ini = -0.000002024 V, v_off_fin = -0.000000539 V 18:29:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000143074 Vs 18:29:10 Voltage Offset Correction: v_off_ini = -0.000001810 V, v_off_fin = 0.000000108 V 18:29:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000144736 Vs 18:29:10 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:29:11 Magnet Current for HTrim , Imag = 4.0017 A Vtrans = 0.667283 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:29:18 Voltage Offset Correction: v_off_ini = -0.000001785 V, v_off_fin = -0.000000596 V 18:29:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000143073 Vs 18:29:24 Voltage Offset Correction: v_off_ini = -0.000001900 V, v_off_fin = -0.000003386 V 18:29:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000143012 Vs 18:29:25 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:29:25 Magnet Current for HTrim , Imag = 4.0017 A Vtrans = 0.667287 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:29:32 Voltage Offset Correction: v_off_ini = -0.000001937 V, v_off_fin = -0.000000960 V 18:29:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000143093 Vs 18:29:39 Voltage Offset Correction: v_off_ini = -0.000002127 V, v_off_fin = -0.000000065 V 18:29:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000144950 Vs 18:29:39 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:29:40 Magnet Current for HTrim , Imag = 4.0017 A Vtrans = 0.667285 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:29:46 Voltage Offset Correction: v_off_ini = -0.000002089 V, v_off_fin = -0.000003409 V 18:29:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000144253 Vs 18:29:53 Voltage Offset Correction: v_off_ini = -0.000001833 V, v_off_fin = -0.000003451 V 18:29:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000143161 Vs 18:29:54 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:29:54 Magnet Current for HTrim , Imag = 4.0017 A Vtrans = 0.667284 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:30:01 Voltage Offset Correction: v_off_ini = -0.000001917 V, v_off_fin = -0.000003787 V 18:30:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000144734 Vs 18:30:08 Voltage Offset Correction: v_off_ini = -0.000001995 V, v_off_fin = -0.000004348 V 18:30:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000142491 Vs 18:30:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000143591 +- 0.000000320 Vs 18:30:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000143591 +- 0.000000320 Vs BL = 0.01435911 +- 0.00003198 Tm 18:30:12 Position moved: 0.000000 m 18:30:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01436 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.01436 0.00003 0.01436 0.00000 18:30:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01436 0.00003 SL = 0.0143591 +- 0.0000320 Tm^2/m^n 18:30:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0143591 +- 0.0000320 Tm^2/m^n 18:30:14 Position moved: 0.000000 m 18:30:14 Magnet system Main current ramping to 0.0000 A... 18:30:25 Magnet system HTrim current ramping to 5.0000 A... 18:30:29 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:30:29 Magnet Current for HTrim , Imag = 5.0029 A Vtrans = 0.834150 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:30:30 MAIN Voltage Measurement, V = 0.000577 V 18:30:31 Temperature Measurement, Probe Number = 0, T = 28.089000 C 18:30:31 Temperature Measurement, Probe Number = 1, T = 28.452000 C 18:30:32 Temperature Measurement, Probe Number = 2, T = 24.856000 C 18:30:32 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = 5.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.09 P4 = Coil, Value = 28.45 P5 = Ambient Temp, Value = 24.86 18:30:32 Magnetic Field Measurement Measuring the magnet strength... 18:30:32 Integrated Voltage Measurement... 18:30:32 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:30:33 Magnet Current for HTrim , Imag = 5.0029 A Vtrans = 0.834151 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:30:41 Voltage Offset Correction: v_off_ini = -0.000002057 V, v_off_fin = -0.000003918 V 18:30:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000173254 Vs 18:30:47 Voltage Offset Correction: v_off_ini = -0.000001965 V, v_off_fin = -0.000000231 V 18:30:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000173175 Vs 18:30:48 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:30:49 Magnet Current for HTrim , Imag = 5.0029 A Vtrans = 0.834151 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:30:55 Voltage Offset Correction: v_off_ini = -0.000002022 V, v_off_fin = 0.000000191 V 18:30:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000170989 Vs 18:31:02 Voltage Offset Correction: v_off_ini = -0.000002094 V, v_off_fin = -0.000005145 V 18:31:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000170695 Vs 18:31:02 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:31:03 Magnet Current for HTrim , Imag = 5.0029 A Vtrans = 0.834151 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:31:10 Voltage Offset Correction: v_off_ini = -0.000001960 V, v_off_fin = -0.000000043 V 18:31:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000171131 Vs 18:31:16 Voltage Offset Correction: v_off_ini = -0.000002059 V, v_off_fin = 0.000000640 V 18:31:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000173768 Vs 18:31:17 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:31:17 Magnet Current for HTrim , Imag = 5.0029 A Vtrans = 0.834152 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:31:24 Voltage Offset Correction: v_off_ini = -0.000002150 V, v_off_fin = -0.000001103 V 18:31:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000171521 Vs 18:31:30 Voltage Offset Correction: v_off_ini = -0.000001990 V, v_off_fin = -0.000001396 V 18:31:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000172120 Vs 18:31:31 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:31:32 Magnet Current for HTrim , Imag = 5.0029 A Vtrans = 0.834154 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:31:38 Voltage Offset Correction: v_off_ini = -0.000002155 V, v_off_fin = -0.000002903 V 18:31:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000172574 Vs 18:31:45 Voltage Offset Correction: v_off_ini = -0.000001981 V, v_off_fin = -0.000004875 V 18:31:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000170574 Vs 18:31:45 Magnet Current for Main , Imag = 0.0076 A Vtrans = 0.000306 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:31:46 Magnet Current for HTrim , Imag = 5.0029 A Vtrans = 0.834155 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:31:53 Voltage Offset Correction: v_off_ini = -0.000002028 V, v_off_fin = -0.000000367 V 18:31:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000171313 Vs 18:31:59 Voltage Offset Correction: v_off_ini = -0.000002190 V, v_off_fin = 0.000000465 V 18:31:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000173346 Vs 18:32:00 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:32:01 Magnet Current for HTrim , Imag = 5.0029 A Vtrans = 0.834155 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:32:07 Voltage Offset Correction: v_off_ini = -0.000001907 V, v_off_fin = -0.000002727 V 18:32:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000172515 Vs 18:32:14 Voltage Offset Correction: v_off_ini = -0.000002079 V, v_off_fin = 0.000001081 V 18:32:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000173859 Vs 18:32:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000172203 +- 0.000000798 Vs 18:32:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000172203 +- 0.000000798 Vs BL = 0.01722025 +- 0.00007984 Tm 18:32:18 Position moved: 0.000000 m 18:32:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01722 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.01722 0.00008 0.01722 0.00000 18:32:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01722 0.00008 SL = 0.0172203 +- 0.0000798 Tm^2/m^n 18:32:18 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0172203 +- 0.0000798 Tm^2/m^n 18:32:21 Position moved: 0.000000 m 18:32:21 Magnet system Main current ramping to 0.0000 A... 18:32:31 Magnet system HTrim current ramping to 6.0000 A... 18:32:35 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:32:35 Magnet Current for HTrim , Imag = 6.0040 A Vtrans = 1.000995 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:32:36 MAIN Voltage Measurement, V = 0.000553 V 18:32:37 Temperature Measurement, Probe Number = 0, T = 28.044000 C 18:32:37 Temperature Measurement, Probe Number = 1, T = 28.435000 C 18:32:38 Temperature Measurement, Probe Number = 2, T = 24.938000 C 18:32:38 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = 6.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.04 P4 = Coil, Value = 28.43 P5 = Ambient Temp, Value = 24.94 18:32:38 Magnetic Field Measurement Measuring the magnet strength... 18:32:38 Integrated Voltage Measurement... 18:32:38 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:32:39 Magnet Current for HTrim , Imag = 6.0040 A Vtrans = 1.000997 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:32:47 Voltage Offset Correction: v_off_ini = -0.000002216 V, v_off_fin = 0.000000662 V 18:32:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000199223 Vs 18:32:53 Voltage Offset Correction: v_off_ini = -0.000001979 V, v_off_fin = -0.000004470 V 18:32:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000199241 Vs 18:32:54 Magnet Current for Main , Imag = 0.0076 A Vtrans = 0.000306 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:32:55 Magnet Current for HTrim , Imag = 6.0040 A Vtrans = 1.000998 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:33:01 Voltage Offset Correction: v_off_ini = -0.000002121 V, v_off_fin = -0.000000655 V 18:33:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000199780 Vs 18:33:08 Voltage Offset Correction: v_off_ini = -0.000001831 V, v_off_fin = 0.000001882 V 18:33:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000202255 Vs 18:33:08 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:33:09 Magnet Current for HTrim , Imag = 6.0040 A Vtrans = 1.000998 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:33:16 Voltage Offset Correction: v_off_ini = -0.000002004 V, v_off_fin = -0.000003971 V 18:33:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000201453 Vs 18:33:22 Voltage Offset Correction: v_off_ini = -0.000002176 V, v_off_fin = 0.000002043 V 18:33:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000202201 Vs 18:33:23 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:33:23 Magnet Current for HTrim , Imag = 6.0040 A Vtrans = 1.000996 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:33:30 Voltage Offset Correction: v_off_ini = -0.000002312 V, v_off_fin = -0.000001803 V 18:33:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000200247 Vs 18:33:37 Voltage Offset Correction: v_off_ini = -0.000002131 V, v_off_fin = 0.000000895 V 18:33:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000202203 Vs 18:33:37 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:33:38 Magnet Current for HTrim , Imag = 6.0040 A Vtrans = 1.000997 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:33:44 Voltage Offset Correction: v_off_ini = -0.000002086 V, v_off_fin = 0.000000059 V 18:33:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000199300 Vs 18:33:51 Voltage Offset Correction: v_off_ini = -0.000002234 V, v_off_fin = -0.000000066 V 18:33:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000201675 Vs 18:33:52 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:33:52 Magnet Current for HTrim , Imag = 6.0040 A Vtrans = 1.000999 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:33:59 Voltage Offset Correction: v_off_ini = -0.000002120 V, v_off_fin = -0.000004419 V 18:33:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000201671 Vs 18:34:06 Voltage Offset Correction: v_off_ini = -0.000002062 V, v_off_fin = 0.000001687 V 18:34:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000202524 Vs 18:34:06 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:34:07 Magnet Current for HTrim , Imag = 6.0040 A Vtrans = 1.001001 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:34:13 Voltage Offset Correction: v_off_ini = -0.000001866 V, v_off_fin = 0.000000559 V 18:34:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000199265 Vs 18:34:20 Voltage Offset Correction: v_off_ini = -0.000002084 V, v_off_fin = 0.000001259 V 18:34:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000202279 Vs 18:34:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000200951 +- 0.000000875 Vs 18:34:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000200951 +- 0.000000875 Vs BL = 0.02009512 +- 0.00008753 Tm 18:34:24 Position moved: 0.000000 m 18:34:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02010 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.02010 0.00009 0.02010 0.00000 18:34:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02010 0.00009 SL = 0.0200951 +- 0.0000875 Tm^2/m^n 18:34:24 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0200951 +- 0.0000875 Tm^2/m^n 18:34:27 Position moved: 0.000000 m 18:34:27 Magnet system Main current ramping to 0.0000 A... 18:34:37 Magnet system HTrim current ramping to 5.0000 A... 18:34:41 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:34:41 Magnet Current for HTrim , Imag = 5.0030 A Vtrans = 0.834159 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:34:42 MAIN Voltage Measurement, V = 0.000565 V 18:34:43 Temperature Measurement, Probe Number = 0, T = 28.018000 C 18:34:43 Temperature Measurement, Probe Number = 1, T = 28.393000 C 18:34:44 Temperature Measurement, Probe Number = 2, T = 24.871000 C 18:34:44 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = 5.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.02 P4 = Coil, Value = 28.39 P5 = Ambient Temp, Value = 24.87 18:34:44 Magnetic Field Measurement Measuring the magnet strength... 18:34:44 Integrated Voltage Measurement... 18:34:45 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:34:45 Magnet Current for HTrim , Imag = 5.0030 A Vtrans = 0.834159 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:34:53 Voltage Offset Correction: v_off_ini = -0.000002093 V, v_off_fin = -0.000004132 V 18:34:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000173694 Vs 18:35:00 Voltage Offset Correction: v_off_ini = -0.000002198 V, v_off_fin = -0.000002422 V 18:35:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000172675 Vs 18:35:00 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:35:01 Magnet Current for HTrim , Imag = 5.0030 A Vtrans = 0.834158 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:35:08 Voltage Offset Correction: v_off_ini = -0.000002098 V, v_off_fin = -0.000000128 V 18:35:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000171868 Vs 18:35:14 Voltage Offset Correction: v_off_ini = -0.000002172 V, v_off_fin = 0.000000985 V 18:35:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000174467 Vs 18:35:15 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:35:15 Magnet Current for HTrim , Imag = 5.0029 A Vtrans = 0.834157 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:35:22 Voltage Offset Correction: v_off_ini = -0.000002026 V, v_off_fin = -0.000003050 V 18:35:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000173282 Vs 18:35:29 Voltage Offset Correction: v_off_ini = -0.000001919 V, v_off_fin = -0.000001180 V 18:35:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000173245 Vs 18:35:29 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:35:30 Magnet Current for HTrim , Imag = 5.0030 A Vtrans = 0.834157 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:35:37 Voltage Offset Correction: v_off_ini = -0.000001622 V, v_off_fin = -0.000000441 V 18:35:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000172588 Vs 18:35:43 Voltage Offset Correction: v_off_ini = -0.000001857 V, v_off_fin = 0.000001290 V 18:35:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000174347 Vs 18:35:44 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:35:45 Magnet Current for HTrim , Imag = 5.0030 A Vtrans = 0.834158 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:35:51 Voltage Offset Correction: v_off_ini = -0.000001680 V, v_off_fin = -0.000003137 V 18:35:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000173581 Vs 18:35:58 Voltage Offset Correction: v_off_ini = -0.000001868 V, v_off_fin = -0.000002216 V 18:35:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000172696 Vs 18:35:58 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:35:59 Magnet Current for HTrim , Imag = 5.0029 A Vtrans = 0.834156 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:36:06 Voltage Offset Correction: v_off_ini = -0.000001886 V, v_off_fin = 0.000000395 V 18:36:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000171593 Vs 18:36:12 Voltage Offset Correction: v_off_ini = -0.000001940 V, v_off_fin = 0.000001323 V 18:36:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000174560 Vs 18:36:13 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:36:14 Magnet Current for HTrim , Imag = 5.0029 A Vtrans = 0.834156 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:36:20 Voltage Offset Correction: v_off_ini = -0.000001910 V, v_off_fin = -0.000002623 V 18:36:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000173177 Vs 18:36:27 Voltage Offset Correction: v_off_ini = -0.000001896 V, v_off_fin = 0.000001511 V 18:36:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000174571 Vs 18:36:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000173310 +- 0.000000258 Vs 18:36:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000173310 +- 0.000000258 Vs BL = 0.01733103 +- 0.00002577 Tm 18:36:31 Position moved: 0.000000 m 18:36:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01733 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.01733 0.00003 0.01733 0.00000 18:36:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01733 0.00003 SL = 0.0173310 +- 0.0000258 Tm^2/m^n 18:36:31 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0173310 +- 0.0000258 Tm^2/m^n 18:36:33 Position moved: 0.000000 m 18:36:33 Magnet system Main current ramping to 0.0000 A... 18:36:44 Magnet system HTrim current ramping to 4.0000 A... 18:36:48 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:36:48 Magnet Current for HTrim , Imag = 4.0018 A Vtrans = 0.667292 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:36:49 MAIN Voltage Measurement, V = 0.000582 V 18:36:49 Temperature Measurement, Probe Number = 0, T = 28.004000 C 18:36:50 Temperature Measurement, Probe Number = 1, T = 28.379000 C 18:36:51 Temperature Measurement, Probe Number = 2, T = 24.751000 C 18:36:51 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = 4.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 28.00 P4 = Coil, Value = 28.38 P5 = Ambient Temp, Value = 24.75 18:36:51 Magnetic Field Measurement Measuring the magnet strength... 18:36:51 Integrated Voltage Measurement... 18:36:51 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:36:52 Magnet Current for HTrim , Imag = 4.0018 A Vtrans = 0.667293 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:37:00 Voltage Offset Correction: v_off_ini = -0.000001713 V, v_off_fin = -0.000000503 V 18:37:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000144430 Vs 18:37:06 Voltage Offset Correction: v_off_ini = -0.000001935 V, v_off_fin = -0.000002178 V 18:37:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000144834 Vs 18:37:07 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:37:08 Magnet Current for HTrim , Imag = 4.0017 A Vtrans = 0.667289 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:37:14 Voltage Offset Correction: v_off_ini = -0.000001941 V, v_off_fin = -0.000003425 V 18:37:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000145809 Vs 18:37:21 Voltage Offset Correction: v_off_ini = -0.000001878 V, v_off_fin = -0.000004403 V 18:37:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000143798 Vs 18:37:21 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:37:22 Magnet Current for HTrim , Imag = 4.0018 A Vtrans = 0.667292 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:37:28 Voltage Offset Correction: v_off_ini = -0.000001739 V, v_off_fin = -0.000002621 V 18:37:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000145355 Vs 18:37:35 Voltage Offset Correction: v_off_ini = -0.000001762 V, v_off_fin = -0.000001641 V 18:37:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000145052 Vs 18:37:36 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:37:36 Magnet Current for HTrim , Imag = 4.0018 A Vtrans = 0.667292 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:37:43 Voltage Offset Correction: v_off_ini = -0.000002003 V, v_off_fin = -0.000001139 V 18:37:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000144570 Vs 18:37:49 Voltage Offset Correction: v_off_ini = -0.000002016 V, v_off_fin = -0.000003788 V 18:37:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000144007 Vs 18:37:50 Magnet Current for Main , Imag = 0.0081 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:37:51 Magnet Current for HTrim , Imag = 4.0018 A Vtrans = 0.667293 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:37:57 Voltage Offset Correction: v_off_ini = -0.000001819 V, v_off_fin = -0.000002865 V 18:37:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000145515 Vs 18:38:04 Voltage Offset Correction: v_off_ini = -0.000002030 V, v_off_fin = 0.000000414 V 18:38:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000146306 Vs 18:38:04 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:38:05 Magnet Current for HTrim , Imag = 4.0018 A Vtrans = 0.667292 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:38:12 Voltage Offset Correction: v_off_ini = -0.000002003 V, v_off_fin = -0.000001835 V 18:38:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000144972 Vs 18:38:18 Voltage Offset Correction: v_off_ini = -0.000001679 V, v_off_fin = -0.000001579 V 18:38:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000145260 Vs 18:38:19 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:38:19 Magnet Current for HTrim , Imag = 4.0017 A Vtrans = 0.667288 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:38:26 Voltage Offset Correction: v_off_ini = -0.000001950 V, v_off_fin = -0.000003721 V 18:38:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000145756 Vs 18:38:32 Voltage Offset Correction: v_off_ini = -0.000001986 V, v_off_fin = -0.000002412 V 18:38:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000144725 Vs 18:38:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000145028 +- 0.000000481 Vs 18:38:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000145028 +- 0.000000481 Vs BL = 0.01450277 +- 0.00004806 Tm 18:38:36 Position moved: 0.000000 m 18:38:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01450 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.01450 0.00005 0.01450 0.00000 18:38:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01450 0.00005 SL = 0.0145028 +- 0.0000481 Tm^2/m^n 18:38:36 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0145028 +- 0.0000481 Tm^2/m^n 18:38:39 Position moved: 0.000000 m 18:38:39 Magnet system Main current ramping to 0.0000 A... 18:38:49 Magnet system HTrim current ramping to 3.0000 A... 18:38:53 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:38:54 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500670 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:38:55 MAIN Voltage Measurement, V = 0.000551 V 18:38:55 Temperature Measurement, Probe Number = 0, T = 27.981000 C 18:38:56 Temperature Measurement, Probe Number = 1, T = 28.375000 C 18:38:57 Temperature Measurement, Probe Number = 2, T = 24.714000 C 18:38:57 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = 3.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 27.98 P4 = Coil, Value = 28.38 P5 = Ambient Temp, Value = 24.71 18:38:57 Magnetic Field Measurement Measuring the magnet strength... 18:38:57 Integrated Voltage Measurement... 18:38:57 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:38:58 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500673 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:39:06 Voltage Offset Correction: v_off_ini = -0.000001691 V, v_off_fin = -0.000003060 V 18:39:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000117798 Vs 18:39:12 Voltage Offset Correction: v_off_ini = -0.000002013 V, v_off_fin = -0.000001056 V 18:39:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000117491 Vs 18:39:13 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:39:13 Magnet Current for HTrim , Imag = 3.0021 A Vtrans = 0.500674 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:39:20 Voltage Offset Correction: v_off_ini = -0.000002073 V, v_off_fin = -0.000002754 V 18:39:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000117426 Vs 18:39:27 Voltage Offset Correction: v_off_ini = -0.000001894 V, v_off_fin = -0.000001782 V 18:39:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000117233 Vs 18:39:27 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:39:28 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500671 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:39:35 Voltage Offset Correction: v_off_ini = -0.000001973 V, v_off_fin = -0.000002999 V 18:39:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000117473 Vs 18:39:41 Voltage Offset Correction: v_off_ini = -0.000001851 V, v_off_fin = -0.000000488 V 18:39:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000118125 Vs 18:39:42 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:39:42 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500669 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:39:49 Voltage Offset Correction: v_off_ini = -0.000001878 V, v_off_fin = -0.000001099 V 18:39:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000116615 Vs 18:39:56 Voltage Offset Correction: v_off_ini = -0.000001914 V, v_off_fin = -0.000001902 V 18:39:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000117014 Vs 18:39:56 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:39:57 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500667 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:40:03 Voltage Offset Correction: v_off_ini = -0.000002073 V, v_off_fin = -0.000000832 V 18:40:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000116256 Vs 18:40:10 Voltage Offset Correction: v_off_ini = -0.000002140 V, v_off_fin = -0.000000534 V 18:40:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000117667 Vs 18:40:10 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:40:11 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500669 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:40:18 Voltage Offset Correction: v_off_ini = -0.000002257 V, v_off_fin = -0.000003102 V 18:40:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000117598 Vs 18:40:25 Voltage Offset Correction: v_off_ini = -0.000001950 V, v_off_fin = 0.000000018 V 18:40:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000118154 Vs 18:40:25 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:40:26 Magnet Current for HTrim , Imag = 3.0020 A Vtrans = 0.500670 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:40:32 Voltage Offset Correction: v_off_ini = -0.000002187 V, v_off_fin = -0.000002207 V 18:40:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000116941 Vs 18:40:39 Voltage Offset Correction: v_off_ini = -0.000001958 V, v_off_fin = -0.000003263 V 18:40:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000116363 Vs 18:40:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000117297 +- 0.000000458 Vs 18:40:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000117297 +- 0.000000458 Vs BL = 0.01172966 +- 0.00004583 Tm 18:40:43 Position moved: 0.000000 m 18:40:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01173 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.01173 0.00005 0.01173 0.00000 18:40:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01173 0.00005 SL = 0.0117297 +- 0.0000458 Tm^2/m^n 18:40:43 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0117297 +- 0.0000458 Tm^2/m^n 18:40:45 Position moved: 0.000000 m 18:40:45 Magnet system Main current ramping to 0.0000 A... 18:40:56 Magnet system HTrim current ramping to 2.0000 A... 18:41:00 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:41:00 Magnet Current for HTrim , Imag = 2.0007 A Vtrans = 0.333775 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:41:01 MAIN Voltage Measurement, V = 0.000567 V 18:41:02 Temperature Measurement, Probe Number = 0, T = 27.962000 C 18:41:02 Temperature Measurement, Probe Number = 1, T = 28.354000 C 18:41:03 Temperature Measurement, Probe Number = 2, T = 24.805000 C 18:41:03 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = 2.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 27.96 P4 = Coil, Value = 28.35 P5 = Ambient Temp, Value = 24.80 18:41:03 Magnetic Field Measurement Measuring the magnet strength... 18:41:03 Integrated Voltage Measurement... 18:41:03 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:41:04 Magnet Current for HTrim , Imag = 2.0007 A Vtrans = 0.333776 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:41:12 Voltage Offset Correction: v_off_ini = -0.000001867 V, v_off_fin = -0.000001475 V 18:41:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000088555 Vs 18:41:18 Voltage Offset Correction: v_off_ini = -0.000001906 V, v_off_fin = -0.000002004 V 18:41:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000088839 Vs 18:41:19 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:41:20 Magnet Current for HTrim , Imag = 2.0007 A Vtrans = 0.333774 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:41:26 Voltage Offset Correction: v_off_ini = -0.000002216 V, v_off_fin = -0.000003228 V 18:41:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000089385 Vs 18:41:33 Voltage Offset Correction: v_off_ini = -0.000002076 V, v_off_fin = -0.000000525 V 18:41:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000089723 Vs 18:41:33 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:41:34 Magnet Current for HTrim , Imag = 2.0007 A Vtrans = 0.333774 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:41:40 Voltage Offset Correction: v_off_ini = -0.000002092 V, v_off_fin = -0.000003215 V 18:41:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000089459 Vs 18:41:47 Voltage Offset Correction: v_off_ini = -0.000002233 V, v_off_fin = -0.000004057 V 18:41:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000088082 Vs 18:41:48 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:41:48 Magnet Current for HTrim , Imag = 2.0007 A Vtrans = 0.333774 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:41:55 Voltage Offset Correction: v_off_ini = -0.000002193 V, v_off_fin = -0.000002314 V 18:41:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000088867 Vs 18:42:01 Voltage Offset Correction: v_off_ini = -0.000002194 V, v_off_fin = -0.000003588 V 18:42:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000088092 Vs 18:42:02 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:42:03 Magnet Current for HTrim , Imag = 2.0006 A Vtrans = 0.333771 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:42:09 Voltage Offset Correction: v_off_ini = -0.000002129 V, v_off_fin = -0.000001341 V 18:42:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000088442 Vs 18:42:16 Voltage Offset Correction: v_off_ini = -0.000002234 V, v_off_fin = -0.000003556 V 18:42:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000088212 Vs 18:42:17 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:42:17 Magnet Current for HTrim , Imag = 2.0006 A Vtrans = 0.333773 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:42:24 Voltage Offset Correction: v_off_ini = -0.000002144 V, v_off_fin = -0.000001233 V 18:42:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000088501 Vs 18:42:30 Voltage Offset Correction: v_off_ini = -0.000002243 V, v_off_fin = -0.000000704 V 18:42:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000089677 Vs 18:42:31 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:42:32 Magnet Current for HTrim , Imag = 2.0007 A Vtrans = 0.333774 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:42:38 Voltage Offset Correction: v_off_ini = -0.000002195 V, v_off_fin = -0.000002442 V 18:42:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000089413 Vs 18:42:45 Voltage Offset Correction: v_off_ini = -0.000002208 V, v_off_fin = -0.000003589 V 18:42:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000088271 Vs 18:42:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000088823 +- 0.000000376 Vs 18:42:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000088823 +- 0.000000376 Vs BL = 0.00888227 +- 0.00003757 Tm 18:42:49 Position moved: 0.000000 m 18:42:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00888 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00888 0.00004 0.00888 0.00000 18:42:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00888 0.00004 SL = 0.0088823 +- 0.0000376 Tm^2/m^n 18:42:49 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0088823 +- 0.0000376 Tm^2/m^n 18:42:51 Position moved: 0.000000 m 18:42:51 Magnet system Main current ramping to 0.0000 A... 18:43:02 Magnet system HTrim current ramping to 1.0000 A... 18:43:06 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:43:06 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166915 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:43:07 MAIN Voltage Measurement, V = 0.000555 V 18:43:08 Temperature Measurement, Probe Number = 0, T = 27.968000 C 18:43:08 Temperature Measurement, Probe Number = 1, T = 28.363000 C 18:43:09 Temperature Measurement, Probe Number = 2, T = 24.818000 C 18:43:09 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = 1.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 27.97 P4 = Coil, Value = 28.36 P5 = Ambient Temp, Value = 24.82 18:43:09 Magnetic Field Measurement Measuring the magnet strength... 18:43:09 Integrated Voltage Measurement... 18:43:09 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:43:10 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166914 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:43:18 Voltage Offset Correction: v_off_ini = -0.000002183 V, v_off_fin = -0.000001705 V 18:43:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000060609 Vs 18:43:24 Voltage Offset Correction: v_off_ini = -0.000002170 V, v_off_fin = -0.000002963 V 18:43:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000060414 Vs 18:43:25 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:43:26 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166916 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:43:32 Voltage Offset Correction: v_off_ini = -0.000002242 V, v_off_fin = -0.000001832 V 18:43:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000060668 Vs 18:43:39 Voltage Offset Correction: v_off_ini = -0.000002142 V, v_off_fin = -0.000003091 V 18:43:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000060286 Vs 18:43:39 Magnet Current for Main , Imag = 0.0076 A Vtrans = 0.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:43:40 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166916 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:43:47 Voltage Offset Correction: v_off_ini = -0.000002304 V, v_off_fin = -0.000002747 V 18:43:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000061138 Vs 18:43:53 Voltage Offset Correction: v_off_ini = -0.000002335 V, v_off_fin = -0.000003269 V 18:43:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000060334 Vs 18:43:54 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:43:54 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166912 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:44:01 Voltage Offset Correction: v_off_ini = -0.000002365 V, v_off_fin = -0.000002377 V 18:44:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000060742 Vs 18:44:08 Voltage Offset Correction: v_off_ini = -0.000002151 V, v_off_fin = -0.000001448 V 18:44:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000061100 Vs 18:44:08 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:44:09 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166910 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:44:15 Voltage Offset Correction: v_off_ini = -0.000002213 V, v_off_fin = -0.000002044 V 18:44:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000060633 Vs 18:44:22 Voltage Offset Correction: v_off_ini = -0.000002102 V, v_off_fin = -0.000001345 V 18:44:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000061422 Vs 18:44:22 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:44:23 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166913 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:44:30 Voltage Offset Correction: v_off_ini = -0.000002239 V, v_off_fin = -0.000001897 V 18:44:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000060520 Vs 18:44:36 Voltage Offset Correction: v_off_ini = -0.000002368 V, v_off_fin = -0.000003492 V 18:44:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000060268 Vs 18:44:37 Magnet Current for Main , Imag = 0.0076 A Vtrans = 0.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:44:38 Magnet Current for HTrim , Imag = 0.9995 A Vtrans = 0.166910 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:44:44 Voltage Offset Correction: v_off_ini = -0.000002234 V, v_off_fin = -0.000002473 V 18:44:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000060949 Vs 18:44:51 Voltage Offset Correction: v_off_ini = -0.000002291 V, v_off_fin = -0.000001671 V 18:44:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000061115 Vs 18:44:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000060728 +- 0.000000251 Vs 18:44:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000060728 +- 0.000000251 Vs BL = 0.00607284 +- 0.00002509 Tm 18:44:54 Position moved: 0.000000 m 18:44:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00607 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00607 0.00003 0.00607 0.00000 18:44:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00607 0.00003 SL = 0.0060728 +- 0.0000251 Tm^2/m^n 18:44:54 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0060728 +- 0.0000251 Tm^2/m^n 18:44:57 Position moved: 0.000000 m 18:44:57 Magnet system Main current ramping to 0.0000 A... 18:45:07 Magnet system HTrim current ramping to 0.0000 A... 18:45:11 Magnet Current for Main , Imag = 0.0076 A Vtrans = 0.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:45:12 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000311 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:45:13 MAIN Voltage Measurement, V = 0.000565 V 18:45:13 Temperature Measurement, Probe Number = 0, T = 27.941000 C 18:45:14 Temperature Measurement, Probe Number = 1, T = 28.358000 C 18:45:14 Temperature Measurement, Probe Number = 2, T = 24.726000 C 18:45:14 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = HTrim , Value = -0.00 P2 = MAIN, Value = 0.00 P3 = Steel, Value = 27.94 P4 = Coil, Value = 28.36 P5 = Ambient Temp, Value = 24.73 18:45:14 Magnetic Field Measurement Measuring the magnet strength... 18:45:14 Integrated Voltage Measurement... 18:45:15 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:45:16 Magnet Current for HTrim , Imag = -0.0002 A Vtrans = 0.000303 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:45:23 Voltage Offset Correction: v_off_ini = -0.000002196 V, v_off_fin = -0.000002678 V 18:45:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032657 Vs 18:45:30 Voltage Offset Correction: v_off_ini = -0.000002239 V, v_off_fin = -0.000002933 V 18:45:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000032342 Vs 18:45:31 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:45:31 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000312 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:45:38 Voltage Offset Correction: v_off_ini = -0.000002408 V, v_off_fin = -0.000002119 V 18:45:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032487 Vs 18:45:44 Voltage Offset Correction: v_off_ini = -0.000002265 V, v_off_fin = -0.000002046 V 18:45:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000032928 Vs 18:45:45 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:45:46 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000320 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:45:52 Voltage Offset Correction: v_off_ini = -0.000002106 V, v_off_fin = -0.000002379 V 18:45:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032687 Vs 18:45:59 Voltage Offset Correction: v_off_ini = -0.000001886 V, v_off_fin = -0.000001341 V 18:45:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000033160 Vs 18:45:59 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:46:00 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000310 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:46:07 Voltage Offset Correction: v_off_ini = -0.000002039 V, v_off_fin = -0.000001629 V 18:46:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032459 Vs 18:46:13 Voltage Offset Correction: v_off_ini = -0.000001786 V, v_off_fin = -0.000001969 V 18:46:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000032735 Vs 18:46:14 Magnet Current for Main , Imag = 0.0078 A Vtrans = 0.000308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:46:14 Magnet Current for HTrim , Imag = -0.0000 A Vtrans = 0.000325 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:46:21 Voltage Offset Correction: v_off_ini = -0.000001869 V, v_off_fin = -0.000001869 V 18:46:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032453 Vs 18:46:28 Voltage Offset Correction: v_off_ini = -0.000002418 V, v_off_fin = -0.000001638 V 18:46:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000032634 Vs 18:46:28 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:46:29 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000311 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:46:35 Voltage Offset Correction: v_off_ini = -0.000002296 V, v_off_fin = -0.000002216 V 18:46:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032927 Vs 18:46:42 Voltage Offset Correction: v_off_ini = -0.000002170 V, v_off_fin = -0.000002157 V 18:46:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000032399 Vs 18:46:42 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023031 A 18:46:43 Magnet Current for HTrim , Imag = -0.0001 A Vtrans = 0.000308 V, Factor V/A = 0.166667 V/A, Zero Current = 0.001992 A 18:46:50 Voltage Offset Correction: v_off_ini = -0.000002103 V, v_off_fin = -0.000002652 V 18:46:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032979 Vs 18:46:56 Voltage Offset Correction: v_off_ini = -0.000002197 V, v_off_fin = -0.000002996 V 18:46:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000032204 Vs 18:46:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000032646 +- 0.000000130 Vs 18:46:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000032646 +- 0.000000130 Vs BL = 0.00326464 +- 0.00001302 Tm 18:47:00 Position moved: 0.000000 m 18:47:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00326 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00326 0.00001 0.00326 0.00000 18:47:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00326 0.00001 SL = 0.0032646 +- 0.0000130 Tm^2/m^n 18:47:00 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0032646 +- 0.0000130 Tm^2/m^n 18:47:03 Position moved: 0.000000 m 18:47:06 Position moved: 0.000000 m 18:47:08 Magnet system Main current ramping to 0.0000 A... 18:47:09 Magnet system HTrim current ramping to 0.0000 A...