SLAC Magnetic Measurements Date: 05-30-2019 Time: 08:00:53 Project: LCLS-II Magnet Type: Dipole Magnet Name: 4510 Serial Number: BX31B Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integral field strength vs current from 0 to 200 to 0 amps in 10 amp steps. Standardization for MAIN: 10 cycles from 0.0 A to 200.0 A to 0.0 A Test Currents for MAIN (A): 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 110.00 120.00 130.00 140.00 150.00 160.00 170.00 180.00 190.00 200.00 180.00 160.00 140.00 120.00 100.00 80.00 60.00 40.00 20.00 0.00 08:01:20 Position moved: 0.000000 m 08:02:06 Magnet Current for MAIN, Imag = -0.0063 A Vtrans = -0.000063 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 08:02:07 Magnet Current for MAIN, Imag = -0.0064 A Vtrans = -0.000064 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 08:02:08 Magnet Current for MAIN, Imag = -0.0063 A Vtrans = -0.000063 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 08:02:08 Magnet Current for MAIN, Imag = -0.0063 A Vtrans = -0.000063 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 08:02:08 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0063 +- 0.0000 A 08:02:39 Initial Zero Current Measurement for MAIN, Imag_zero = -0.0063035 A 08:02:39 Ambient Measurement Device(s) Being Used, type = None 08:02:39 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 08:02:39 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 08:02:39 XMAG Device(s) Being Used, type = None 08:02:40 Ambient Measurement Device(s) Being Used, type = HP34970 08:02:40 Magnet system MAIN current ramping to 200.0000 A... 08:04:33 Magnet Current for MAIN, Imag = 199.9875 A Vtrans = 1.999812 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:04:33 MAIN (V) Voltage Measurement, V = 14.225895 V 08:04:34 Temperature Measurement, Probe Number = 0, T = 26.939000 C 08:04:35 Temperature Measurement, Probe Number = 1, T = 25.727000 C 08:04:35 Temperature Measurement, Probe Number = 2, T = 18.728000 C 08:04:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.310408 V 08:04:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310408 (V, A, ohm, ...), Measured Value = 28.200118 (C, atm, Hz, ...) 08:04:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.276970 V 08:04:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.276970 (V, A, ohm, ...), Measured Value = 27.735699 (C, atm, Hz, ...) 08:04:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662063 V 08:04:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662063 (V, A, ohm, ...), Measured Value = 124.654725 (C, atm, Hz, ...) 08:04:38 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092180 V 08:04:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092180 (V, A, ohm, ...), Measured Value = 6.913507 (C, atm, Hz, ...) 08:04:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.23 P2 = Coil, Value = 26.94 P3 = Magnet Core, Value = 25.73 P4 = Ambient Temp (C), Value = 18.73 P5 = Supply Temp(C), Value = 28.20 P6 = Return Temp(C), Value = 27.74 P7 = Supply Pres(psi), Value = 124.65 P8 = Return Pres(psi), Value = 6.91 08:05:39 Magnet Current for MAIN, Imag = 199.9869 A Vtrans = 1.999806 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:05:39 MAIN (V) Voltage Measurement, V = 14.260233 V 08:05:40 Temperature Measurement, Probe Number = 0, T = 27.269000 C 08:05:41 Temperature Measurement, Probe Number = 1, T = 25.740000 C 08:05:41 Temperature Measurement, Probe Number = 2, T = 18.774000 C 08:05:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.310579 V 08:05:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310579 (V, A, ohm, ...), Measured Value = 28.202483 (C, atm, Hz, ...) 08:05:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.278461 V 08:05:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.278461 (V, A, ohm, ...), Measured Value = 27.756406 (C, atm, Hz, ...) 08:05:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.653561 V 08:05:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653561 (V, A, ohm, ...), Measured Value = 124.017060 (C, atm, Hz, ...) 08:05:44 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091962 V 08:05:44 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091962 (V, A, ohm, ...), Measured Value = 6.897113 (C, atm, Hz, ...) 08:05:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.26 P2 = Coil, Value = 27.27 P3 = Magnet Core, Value = 25.74 P4 = Ambient Temp (C), Value = 18.77 P5 = Supply Temp(C), Value = 28.20 P6 = Return Temp(C), Value = 27.76 P7 = Supply Pres(psi), Value = 124.02 P8 = Return Pres(psi), Value = 6.90 08:06:45 Magnet Current for MAIN, Imag = 199.9870 A Vtrans = 1.999807 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:06:45 MAIN (V) Voltage Measurement, V = 14.271960 V 08:06:46 Temperature Measurement, Probe Number = 0, T = 27.505000 C 08:06:47 Temperature Measurement, Probe Number = 1, T = 25.776000 C 08:06:47 Temperature Measurement, Probe Number = 2, T = 18.717000 C 08:06:48 Sensor Voltage Measurement, Sensor Number = 0, V = 2.310573 V 08:06:48 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310573 (V, A, ohm, ...), Measured Value = 28.202396 (C, atm, Hz, ...) 08:06:49 Sensor Voltage Measurement, Sensor Number = 1, V = 2.291424 V 08:06:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.291424 (V, A, ohm, ...), Measured Value = 27.936439 (C, atm, Hz, ...) 08:06:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667278 V 08:06:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667278 (V, A, ohm, ...), Measured Value = 125.045865 (C, atm, Hz, ...) 08:06:50 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091960 V 08:06:50 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091960 (V, A, ohm, ...), Measured Value = 6.897015 (C, atm, Hz, ...) 08:06:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.27 P2 = Coil, Value = 27.50 P3 = Magnet Core, Value = 25.78 P4 = Ambient Temp (C), Value = 18.72 P5 = Supply Temp(C), Value = 28.20 P6 = Return Temp(C), Value = 27.94 P7 = Supply Pres(psi), Value = 125.05 P8 = Return Pres(psi), Value = 6.90 08:07:51 Magnet Current for MAIN, Imag = 199.9866 A Vtrans = 1.999803 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:07:51 MAIN (V) Voltage Measurement, V = 14.276337 V 08:07:52 Temperature Measurement, Probe Number = 0, T = 27.628000 C 08:07:53 Temperature Measurement, Probe Number = 1, T = 25.821000 C 08:07:53 Temperature Measurement, Probe Number = 2, T = 18.745000 C 08:07:54 Sensor Voltage Measurement, Sensor Number = 0, V = 2.310392 V 08:07:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310392 (V, A, ohm, ...), Measured Value = 28.199889 (C, atm, Hz, ...) 08:07:55 Sensor Voltage Measurement, Sensor Number = 1, V = 2.306308 V 08:07:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.306308 (V, A, ohm, ...), Measured Value = 28.143165 (C, atm, Hz, ...) 08:07:55 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663401 V 08:07:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663401 (V, A, ohm, ...), Measured Value = 124.755112 (C, atm, Hz, ...) 08:07:56 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092106 V 08:07:56 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092106 (V, A, ohm, ...), Measured Value = 6.907980 (C, atm, Hz, ...) 08:07:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.63 P3 = Magnet Core, Value = 25.82 P4 = Ambient Temp (C), Value = 18.75 P5 = Supply Temp(C), Value = 28.20 P6 = Return Temp(C), Value = 28.14 P7 = Supply Pres(psi), Value = 124.76 P8 = Return Pres(psi), Value = 6.91 08:08:57 Magnet Current for MAIN, Imag = 199.9863 A Vtrans = 1.999799 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:08:57 MAIN (V) Voltage Measurement, V = 14.278085 V 08:08:58 Temperature Measurement, Probe Number = 0, T = 27.721000 C 08:08:59 Temperature Measurement, Probe Number = 1, T = 25.864000 C 08:08:59 Temperature Measurement, Probe Number = 2, T = 18.874000 C 08:09:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.310294 V 08:09:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310294 (V, A, ohm, ...), Measured Value = 28.198529 (C, atm, Hz, ...) 08:09:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.321343 V 08:09:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321343 (V, A, ohm, ...), Measured Value = 28.351993 (C, atm, Hz, ...) 08:09:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.668815 V 08:09:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.668815 (V, A, ohm, ...), Measured Value = 125.161125 (C, atm, Hz, ...) 08:09:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092110 V 08:09:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092110 (V, A, ohm, ...), Measured Value = 6.908265 (C, atm, Hz, ...) 08:09:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.72 P3 = Magnet Core, Value = 25.86 P4 = Ambient Temp (C), Value = 18.87 P5 = Supply Temp(C), Value = 28.20 P6 = Return Temp(C), Value = 28.35 P7 = Supply Pres(psi), Value = 125.16 P8 = Return Pres(psi), Value = 6.91 08:10:03 Magnet Current for MAIN, Imag = 199.9851 A Vtrans = 1.999788 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:10:03 MAIN (V) Voltage Measurement, V = 14.279029 V 08:10:04 Temperature Measurement, Probe Number = 0, T = 27.784000 C 08:10:05 Temperature Measurement, Probe Number = 1, T = 25.906000 C 08:10:05 Temperature Measurement, Probe Number = 2, T = 18.928000 C 08:10:06 Sensor Voltage Measurement, Sensor Number = 0, V = 2.310335 V 08:10:06 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310335 (V, A, ohm, ...), Measured Value = 28.199094 (C, atm, Hz, ...) 08:10:07 Sensor Voltage Measurement, Sensor Number = 1, V = 2.336701 V 08:10:07 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336701 (V, A, ohm, ...), Measured Value = 28.565288 (C, atm, Hz, ...) 08:10:07 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656919 V 08:10:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656919 (V, A, ohm, ...), Measured Value = 124.268925 (C, atm, Hz, ...) 08:10:08 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092109 V 08:10:08 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092109 (V, A, ohm, ...), Measured Value = 6.908167 (C, atm, Hz, ...) 08:10:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.78 P3 = Magnet Core, Value = 25.91 P4 = Ambient Temp (C), Value = 18.93 P5 = Supply Temp(C), Value = 28.20 P6 = Return Temp(C), Value = 28.57 P7 = Supply Pres(psi), Value = 124.27 P8 = Return Pres(psi), Value = 6.91 08:11:09 Magnet Current for MAIN, Imag = 199.9850 A Vtrans = 1.999787 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:11:09 MAIN (V) Voltage Measurement, V = 14.279578 V 08:11:10 Temperature Measurement, Probe Number = 0, T = 27.817000 C 08:11:11 Temperature Measurement, Probe Number = 1, T = 25.930000 C 08:11:11 Temperature Measurement, Probe Number = 2, T = 18.937000 C 08:11:12 Sensor Voltage Measurement, Sensor Number = 0, V = 2.310370 V 08:11:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310370 (V, A, ohm, ...), Measured Value = 28.199589 (C, atm, Hz, ...) 08:11:13 Sensor Voltage Measurement, Sensor Number = 1, V = 2.352003 V 08:11:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352003 (V, A, ohm, ...), Measured Value = 28.777821 (C, atm, Hz, ...) 08:11:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.653431 V 08:11:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653431 (V, A, ohm, ...), Measured Value = 124.007340 (C, atm, Hz, ...) 08:11:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092145 V 08:11:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092145 (V, A, ohm, ...), Measured Value = 6.910838 (C, atm, Hz, ...) 08:11:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.98 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.82 P3 = Magnet Core, Value = 25.93 P4 = Ambient Temp (C), Value = 18.94 P5 = Supply Temp(C), Value = 28.20 P6 = Return Temp(C), Value = 28.78 P7 = Supply Pres(psi), Value = 124.01 P8 = Return Pres(psi), Value = 6.91 08:12:15 Magnet Current for MAIN, Imag = 199.9856 A Vtrans = 1.999793 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:12:15 MAIN (V) Voltage Measurement, V = 14.279986 V 08:12:16 Temperature Measurement, Probe Number = 0, T = 27.812000 C 08:12:17 Temperature Measurement, Probe Number = 1, T = 25.959000 C 08:12:17 Temperature Measurement, Probe Number = 2, T = 18.929000 C 08:12:18 Sensor Voltage Measurement, Sensor Number = 0, V = 2.310686 V 08:12:18 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310686 (V, A, ohm, ...), Measured Value = 28.203967 (C, atm, Hz, ...) 08:12:19 Sensor Voltage Measurement, Sensor Number = 1, V = 2.366294 V 08:12:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.366294 (V, A, ohm, ...), Measured Value = 28.976303 (C, atm, Hz, ...) 08:12:19 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664521 V 08:12:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664521 (V, A, ohm, ...), Measured Value = 124.839098 (C, atm, Hz, ...) 08:12:20 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092181 V 08:12:20 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092181 (V, A, ohm, ...), Measured Value = 6.913605 (C, atm, Hz, ...) 08:12:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.81 P3 = Magnet Core, Value = 25.96 P4 = Ambient Temp (C), Value = 18.93 P5 = Supply Temp(C), Value = 28.20 P6 = Return Temp(C), Value = 28.98 P7 = Supply Pres(psi), Value = 124.84 P8 = Return Pres(psi), Value = 6.91 08:13:21 Magnet Current for MAIN, Imag = 199.9857 A Vtrans = 1.999794 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:13:21 MAIN (V) Voltage Measurement, V = 14.280407 V 08:13:22 Temperature Measurement, Probe Number = 0, T = 27.843000 C 08:13:23 Temperature Measurement, Probe Number = 1, T = 25.989000 C 08:13:23 Temperature Measurement, Probe Number = 2, T = 18.929000 C 08:13:24 Sensor Voltage Measurement, Sensor Number = 0, V = 2.310996 V 08:13:24 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310996 (V, A, ohm, ...), Measured Value = 28.208274 (C, atm, Hz, ...) 08:13:25 Sensor Voltage Measurement, Sensor Number = 1, V = 2.379701 V 08:13:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.379701 (V, A, ohm, ...), Measured Value = 29.162515 (C, atm, Hz, ...) 08:13:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.670040 V 08:13:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670040 (V, A, ohm, ...), Measured Value = 125.253023 (C, atm, Hz, ...) 08:13:26 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092209 V 08:13:26 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092209 (V, A, ohm, ...), Measured Value = 6.915697 (C, atm, Hz, ...) 08:13:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.84 P3 = Magnet Core, Value = 25.99 P4 = Ambient Temp (C), Value = 18.93 P5 = Supply Temp(C), Value = 28.21 P6 = Return Temp(C), Value = 29.16 P7 = Supply Pres(psi), Value = 125.25 P8 = Return Pres(psi), Value = 6.92 08:14:27 Magnet Current for MAIN, Imag = 199.9860 A Vtrans = 1.999797 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:14:27 MAIN (V) Voltage Measurement, V = 14.280854 V 08:14:28 Temperature Measurement, Probe Number = 0, T = 27.866000 C 08:14:28 Temperature Measurement, Probe Number = 1, T = 26.015000 C 08:14:29 Temperature Measurement, Probe Number = 2, T = 18.890000 C 08:14:30 Sensor Voltage Measurement, Sensor Number = 0, V = 2.311227 V 08:14:30 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.311227 (V, A, ohm, ...), Measured Value = 28.211487 (C, atm, Hz, ...) 08:14:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.391750 V 08:14:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.391750 (V, A, ohm, ...), Measured Value = 29.329856 (C, atm, Hz, ...) 08:14:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661453 V 08:14:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661453 (V, A, ohm, ...), Measured Value = 124.608968 (C, atm, Hz, ...) 08:14:32 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092423 V 08:14:32 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092423 (V, A, ohm, ...), Measured Value = 6.931718 (C, atm, Hz, ...) 08:14:32 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.87 P3 = Magnet Core, Value = 26.02 P4 = Ambient Temp (C), Value = 18.89 P5 = Supply Temp(C), Value = 28.21 P6 = Return Temp(C), Value = 29.33 P7 = Supply Pres(psi), Value = 124.61 P8 = Return Pres(psi), Value = 6.93 08:15:33 Magnet Current for MAIN, Imag = 199.9856 A Vtrans = 1.999793 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:15:33 MAIN (V) Voltage Measurement, V = 14.281326 V 08:15:34 Temperature Measurement, Probe Number = 0, T = 27.919000 C 08:15:34 Temperature Measurement, Probe Number = 1, T = 26.040000 C 08:15:35 Temperature Measurement, Probe Number = 2, T = 18.884000 C 08:15:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.311781 V 08:15:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.311781 (V, A, ohm, ...), Measured Value = 28.219185 (C, atm, Hz, ...) 08:15:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.402283 V 08:15:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.402283 (V, A, ohm, ...), Measured Value = 29.476153 (C, atm, Hz, ...) 08:15:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664861 V 08:15:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664861 (V, A, ohm, ...), Measured Value = 124.864553 (C, atm, Hz, ...) 08:15:38 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092397 V 08:15:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092397 (V, A, ohm, ...), Measured Value = 6.929812 (C, atm, Hz, ...) 08:15:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.92 P3 = Magnet Core, Value = 26.04 P4 = Ambient Temp (C), Value = 18.88 P5 = Supply Temp(C), Value = 28.22 P6 = Return Temp(C), Value = 29.48 P7 = Supply Pres(psi), Value = 124.86 P8 = Return Pres(psi), Value = 6.93 08:16:38 Magnet Current for MAIN, Imag = 199.9864 A Vtrans = 1.999801 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:16:39 MAIN (V) Voltage Measurement, V = 14.281735 V 08:16:40 Temperature Measurement, Probe Number = 0, T = 27.909000 C 08:16:40 Temperature Measurement, Probe Number = 1, T = 26.067000 C 08:16:41 Temperature Measurement, Probe Number = 2, T = 19.025000 C 08:16:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.312114 V 08:16:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.312114 (V, A, ohm, ...), Measured Value = 28.223810 (C, atm, Hz, ...) 08:16:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.411491 V 08:16:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.411491 (V, A, ohm, ...), Measured Value = 29.604036 (C, atm, Hz, ...) 08:16:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664310 V 08:16:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664310 (V, A, ohm, ...), Measured Value = 124.823272 (C, atm, Hz, ...) 08:16:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092531 V 08:16:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092531 (V, A, ohm, ...), Measured Value = 6.939818 (C, atm, Hz, ...) 08:16:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.91 P3 = Magnet Core, Value = 26.07 P4 = Ambient Temp (C), Value = 19.02 P5 = Supply Temp(C), Value = 28.22 P6 = Return Temp(C), Value = 29.60 P7 = Supply Pres(psi), Value = 124.82 P8 = Return Pres(psi), Value = 6.94 08:17:44 Magnet Current for MAIN, Imag = 199.9866 A Vtrans = 1.999803 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:17:45 MAIN (V) Voltage Measurement, V = 14.282296 V 08:17:46 Temperature Measurement, Probe Number = 0, T = 27.851000 C 08:17:46 Temperature Measurement, Probe Number = 1, T = 26.102000 C 08:17:47 Temperature Measurement, Probe Number = 2, T = 19.141000 C 08:17:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.312494 V 08:17:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.312494 (V, A, ohm, ...), Measured Value = 28.229087 (C, atm, Hz, ...) 08:17:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.419528 V 08:17:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.419528 (V, A, ohm, ...), Measured Value = 29.715664 (C, atm, Hz, ...) 08:17:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661186 V 08:17:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661186 (V, A, ohm, ...), Measured Value = 124.588950 (C, atm, Hz, ...) 08:17:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092644 V 08:17:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092644 (V, A, ohm, ...), Measured Value = 6.948308 (C, atm, Hz, ...) 08:17:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.85 P3 = Magnet Core, Value = 26.10 P4 = Ambient Temp (C), Value = 19.14 P5 = Supply Temp(C), Value = 28.23 P6 = Return Temp(C), Value = 29.72 P7 = Supply Pres(psi), Value = 124.59 P8 = Return Pres(psi), Value = 6.95 08:18:50 Magnet Current for MAIN, Imag = 199.9870 A Vtrans = 1.999807 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:18:51 MAIN (V) Voltage Measurement, V = 14.282806 V 08:18:51 Temperature Measurement, Probe Number = 0, T = 27.837000 C 08:18:52 Temperature Measurement, Probe Number = 1, T = 26.128000 C 08:18:53 Temperature Measurement, Probe Number = 2, T = 19.492000 C 08:18:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.312688 V 08:18:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.312688 (V, A, ohm, ...), Measured Value = 28.231771 (C, atm, Hz, ...) 08:18:54 Sensor Voltage Measurement, Sensor Number = 1, V = 2.426642 V 08:18:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.426642 (V, A, ohm, ...), Measured Value = 29.814472 (C, atm, Hz, ...) 08:18:55 Sensor Voltage Measurement, Sensor Number = 2, V = 2.654943 V 08:18:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.654943 (V, A, ohm, ...), Measured Value = 124.120688 (C, atm, Hz, ...) 08:18:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092681 V 08:18:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092681 (V, A, ohm, ...), Measured Value = 6.951067 (C, atm, Hz, ...) 08:18:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.84 P3 = Magnet Core, Value = 26.13 P4 = Ambient Temp (C), Value = 19.49 P5 = Supply Temp(C), Value = 28.23 P6 = Return Temp(C), Value = 29.81 P7 = Supply Pres(psi), Value = 124.12 P8 = Return Pres(psi), Value = 6.95 08:19:56 Magnet Current for MAIN, Imag = 199.9875 A Vtrans = 1.999812 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:19:57 MAIN (V) Voltage Measurement, V = 14.283151 V 08:19:57 Temperature Measurement, Probe Number = 0, T = 27.765000 C 08:19:58 Temperature Measurement, Probe Number = 1, T = 26.149000 C 08:19:59 Temperature Measurement, Probe Number = 2, T = 19.543000 C 08:19:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.313089 V 08:19:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.313089 (V, A, ohm, ...), Measured Value = 28.237350 (C, atm, Hz, ...) 08:20:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.432875 V 08:20:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.432875 (V, A, ohm, ...), Measured Value = 29.901047 (C, atm, Hz, ...) 08:20:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665651 V 08:20:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665651 (V, A, ohm, ...), Measured Value = 124.923847 (C, atm, Hz, ...) 08:20:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092761 V 08:20:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092761 (V, A, ohm, ...), Measured Value = 6.957075 (C, atm, Hz, ...) 08:20:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.77 P3 = Magnet Core, Value = 26.15 P4 = Ambient Temp (C), Value = 19.54 P5 = Supply Temp(C), Value = 28.24 P6 = Return Temp(C), Value = 29.90 P7 = Supply Pres(psi), Value = 124.92 P8 = Return Pres(psi), Value = 6.96 08:21:02 Magnet Current for MAIN, Imag = 199.9882 A Vtrans = 1.999818 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:21:03 MAIN (V) Voltage Measurement, V = 14.283215 V 08:21:03 Temperature Measurement, Probe Number = 0, T = 27.738000 C 08:21:04 Temperature Measurement, Probe Number = 1, T = 26.179000 C 08:21:04 Temperature Measurement, Probe Number = 2, T = 19.560000 C 08:21:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.312637 V 08:21:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.312637 (V, A, ohm, ...), Measured Value = 28.231065 (C, atm, Hz, ...) 08:21:06 Sensor Voltage Measurement, Sensor Number = 1, V = 2.438430 V 08:21:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.438430 (V, A, ohm, ...), Measured Value = 29.978194 (C, atm, Hz, ...) 08:21:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662310 V 08:21:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662310 (V, A, ohm, ...), Measured Value = 124.673220 (C, atm, Hz, ...) 08:21:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092901 V 08:21:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092901 (V, A, ohm, ...), Measured Value = 6.967560 (C, atm, Hz, ...) 08:21:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.74 P3 = Magnet Core, Value = 26.18 P4 = Ambient Temp (C), Value = 19.56 P5 = Supply Temp(C), Value = 28.23 P6 = Return Temp(C), Value = 29.98 P7 = Supply Pres(psi), Value = 124.67 P8 = Return Pres(psi), Value = 6.97 08:22:08 Magnet Current for MAIN, Imag = 199.9883 A Vtrans = 1.999820 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:22:08 MAIN (V) Voltage Measurement, V = 14.283113 V 08:22:09 Temperature Measurement, Probe Number = 0, T = 27.737000 C 08:22:10 Temperature Measurement, Probe Number = 1, T = 26.186000 C 08:22:10 Temperature Measurement, Probe Number = 2, T = 19.423000 C 08:22:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.312375 V 08:22:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.312375 (V, A, ohm, ...), Measured Value = 28.227428 (C, atm, Hz, ...) 08:22:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.443400 V 08:22:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.443400 (V, A, ohm, ...), Measured Value = 30.047219 (C, atm, Hz, ...) 08:22:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667400 V 08:22:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667400 (V, A, ohm, ...), Measured Value = 125.055023 (C, atm, Hz, ...) 08:22:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092893 V 08:22:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092893 (V, A, ohm, ...), Measured Value = 6.966990 (C, atm, Hz, ...) 08:22:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.74 P3 = Magnet Core, Value = 26.19 P4 = Ambient Temp (C), Value = 19.42 P5 = Supply Temp(C), Value = 28.23 P6 = Return Temp(C), Value = 30.05 P7 = Supply Pres(psi), Value = 125.06 P8 = Return Pres(psi), Value = 6.97 08:23:14 Magnet Current for MAIN, Imag = 199.9885 A Vtrans = 1.999822 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:23:14 MAIN (V) Voltage Measurement, V = 14.283164 V 08:23:15 Temperature Measurement, Probe Number = 0, T = 27.731000 C 08:23:16 Temperature Measurement, Probe Number = 1, T = 26.170000 C 08:23:16 Temperature Measurement, Probe Number = 2, T = 19.489000 C 08:23:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.312398 V 08:23:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.312398 (V, A, ohm, ...), Measured Value = 28.227746 (C, atm, Hz, ...) 08:23:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.447963 V 08:23:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.447963 (V, A, ohm, ...), Measured Value = 30.110597 (C, atm, Hz, ...) 08:23:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658395 V 08:23:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658395 (V, A, ohm, ...), Measured Value = 124.379603 (C, atm, Hz, ...) 08:23:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092767 V 08:23:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092767 (V, A, ohm, ...), Measured Value = 6.957547 (C, atm, Hz, ...) 08:23:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.73 P3 = Magnet Core, Value = 26.17 P4 = Ambient Temp (C), Value = 19.49 P5 = Supply Temp(C), Value = 28.23 P6 = Return Temp(C), Value = 30.11 P7 = Supply Pres(psi), Value = 124.38 P8 = Return Pres(psi), Value = 6.96 08:24:20 Magnet Current for MAIN, Imag = 199.9887 A Vtrans = 1.999824 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:24:20 MAIN (V) Voltage Measurement, V = 14.283291 V 08:24:21 Temperature Measurement, Probe Number = 0, T = 27.771000 C 08:24:22 Temperature Measurement, Probe Number = 1, T = 26.167000 C 08:24:22 Temperature Measurement, Probe Number = 2, T = 19.264000 C 08:24:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.312771 V 08:24:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.312771 (V, A, ohm, ...), Measured Value = 28.232936 (C, atm, Hz, ...) 08:24:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.452202 V 08:24:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.452202 (V, A, ohm, ...), Measured Value = 30.169472 (C, atm, Hz, ...) 08:24:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.651883 V 08:24:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.651883 (V, A, ohm, ...), Measured Value = 123.891225 (C, atm, Hz, ...) 08:24:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092861 V 08:24:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092861 (V, A, ohm, ...), Measured Value = 6.964605 (C, atm, Hz, ...) 08:24:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.77 P3 = Magnet Core, Value = 26.17 P4 = Ambient Temp (C), Value = 19.26 P5 = Supply Temp(C), Value = 28.23 P6 = Return Temp(C), Value = 30.17 P7 = Supply Pres(psi), Value = 123.89 P8 = Return Pres(psi), Value = 6.96 08:25:26 Magnet Current for MAIN, Imag = 199.9888 A Vtrans = 1.999825 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:25:26 MAIN (V) Voltage Measurement, V = 14.283432 V 08:25:27 Temperature Measurement, Probe Number = 0, T = 27.874000 C 08:25:28 Temperature Measurement, Probe Number = 1, T = 26.185000 C 08:25:28 Temperature Measurement, Probe Number = 2, T = 19.203000 C 08:25:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.312644 V 08:25:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.312644 (V, A, ohm, ...), Measured Value = 28.231171 (C, atm, Hz, ...) 08:25:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.456009 V 08:25:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.456009 (V, A, ohm, ...), Measured Value = 30.222346 (C, atm, Hz, ...) 08:25:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658512 V 08:25:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658512 (V, A, ohm, ...), Measured Value = 124.388370 (C, atm, Hz, ...) 08:25:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092990 V 08:25:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092990 (V, A, ohm, ...), Measured Value = 6.974235 (C, atm, Hz, ...) 08:25:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.87 P3 = Magnet Core, Value = 26.18 P4 = Ambient Temp (C), Value = 19.20 P5 = Supply Temp(C), Value = 28.23 P6 = Return Temp(C), Value = 30.22 P7 = Supply Pres(psi), Value = 124.39 P8 = Return Pres(psi), Value = 6.97 08:26:32 Magnet Current for MAIN, Imag = 199.9887 A Vtrans = 1.999824 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:26:32 MAIN (V) Voltage Measurement, V = 14.283572 V 08:26:33 Temperature Measurement, Probe Number = 0, T = 27.909000 C 08:26:34 Temperature Measurement, Probe Number = 1, T = 26.216000 C 08:26:34 Temperature Measurement, Probe Number = 2, T = 19.189000 C 08:26:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.312626 V 08:26:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.312626 (V, A, ohm, ...), Measured Value = 28.230924 (C, atm, Hz, ...) 08:26:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.459384 V 08:26:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.459384 (V, A, ohm, ...), Measured Value = 30.269217 (C, atm, Hz, ...) 08:26:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659523 V 08:26:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659523 (V, A, ohm, ...), Measured Value = 124.464255 (C, atm, Hz, ...) 08:26:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093111 V 08:26:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093111 (V, A, ohm, ...), Measured Value = 6.983288 (C, atm, Hz, ...) 08:26:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.91 P3 = Magnet Core, Value = 26.22 P4 = Ambient Temp (C), Value = 19.19 P5 = Supply Temp(C), Value = 28.23 P6 = Return Temp(C), Value = 30.27 P7 = Supply Pres(psi), Value = 124.46 P8 = Return Pres(psi), Value = 6.98 08:27:38 Magnet Current for MAIN, Imag = 199.9889 A Vtrans = 1.999826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:27:38 MAIN (V) Voltage Measurement, V = 14.283623 V 08:27:39 Temperature Measurement, Probe Number = 0, T = 27.874000 C 08:27:40 Temperature Measurement, Probe Number = 1, T = 26.203000 C 08:27:40 Temperature Measurement, Probe Number = 2, T = 19.123000 C 08:27:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.312680 V 08:27:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.312680 (V, A, ohm, ...), Measured Value = 28.231665 (C, atm, Hz, ...) 08:27:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.462379 V 08:27:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.462379 (V, A, ohm, ...), Measured Value = 30.310826 (C, atm, Hz, ...) 08:27:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658348 V 08:27:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658348 (V, A, ohm, ...), Measured Value = 124.376078 (C, atm, Hz, ...) 08:27:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093052 V 08:27:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093052 (V, A, ohm, ...), Measured Value = 6.978907 (C, atm, Hz, ...) 08:27:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.87 P3 = Magnet Core, Value = 26.20 P4 = Ambient Temp (C), Value = 19.12 P5 = Supply Temp(C), Value = 28.23 P6 = Return Temp(C), Value = 30.31 P7 = Supply Pres(psi), Value = 124.38 P8 = Return Pres(psi), Value = 6.98 08:28:44 Magnet Current for MAIN, Imag = 199.9896 A Vtrans = 1.999832 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:28:44 MAIN (V) Voltage Measurement, V = 14.283712 V 08:28:45 Temperature Measurement, Probe Number = 0, T = 27.858000 C 08:28:45 Temperature Measurement, Probe Number = 1, T = 26.184000 C 08:28:46 Temperature Measurement, Probe Number = 2, T = 19.023000 C 08:28:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.312844 V 08:28:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.312844 (V, A, ohm, ...), Measured Value = 28.233943 (C, atm, Hz, ...) 08:28:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.464870 V 08:28:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.464870 (V, A, ohm, ...), Measured Value = 30.345411 (C, atm, Hz, ...) 08:28:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.671451 V 08:28:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.671451 (V, A, ohm, ...), Measured Value = 125.358840 (C, atm, Hz, ...) 08:28:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093032 V 08:28:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093032 (V, A, ohm, ...), Measured Value = 6.977378 (C, atm, Hz, ...) 08:28:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.86 P3 = Magnet Core, Value = 26.18 P4 = Ambient Temp (C), Value = 19.02 P5 = Supply Temp(C), Value = 28.23 P6 = Return Temp(C), Value = 30.35 P7 = Supply Pres(psi), Value = 125.36 P8 = Return Pres(psi), Value = 6.98 08:29:50 Magnet Current for MAIN, Imag = 199.9896 A Vtrans = 1.999832 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:29:50 MAIN (V) Voltage Measurement, V = 14.284070 V 08:29:51 Temperature Measurement, Probe Number = 0, T = 27.853000 C 08:29:51 Temperature Measurement, Probe Number = 1, T = 26.239000 C 08:29:52 Temperature Measurement, Probe Number = 2, T = 19.082000 C 08:29:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.313421 V 08:29:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.313421 (V, A, ohm, ...), Measured Value = 28.241957 (C, atm, Hz, ...) 08:29:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.466978 V 08:29:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.466978 (V, A, ohm, ...), Measured Value = 30.374699 (C, atm, Hz, ...) 08:29:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658622 V 08:29:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658622 (V, A, ohm, ...), Measured Value = 124.396665 (C, atm, Hz, ...) 08:29:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093108 V 08:29:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093108 (V, A, ohm, ...), Measured Value = 6.983100 (C, atm, Hz, ...) 08:29:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.85 P3 = Magnet Core, Value = 26.24 P4 = Ambient Temp (C), Value = 19.08 P5 = Supply Temp(C), Value = 28.24 P6 = Return Temp(C), Value = 30.37 P7 = Supply Pres(psi), Value = 124.40 P8 = Return Pres(psi), Value = 6.98 08:30:55 Magnet Current for MAIN, Imag = 199.9897 A Vtrans = 1.999834 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:30:56 MAIN (V) Voltage Measurement, V = 14.284567 V 08:30:57 Temperature Measurement, Probe Number = 0, T = 27.840000 C 08:30:57 Temperature Measurement, Probe Number = 1, T = 26.285000 C 08:30:58 Temperature Measurement, Probe Number = 2, T = 19.160000 C 08:30:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.313698 V 08:30:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.313698 (V, A, ohm, ...), Measured Value = 28.245806 (C, atm, Hz, ...) 08:30:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.468731 V 08:30:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.468731 (V, A, ohm, ...), Measured Value = 30.399043 (C, atm, Hz, ...) 08:31:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662480 V 08:31:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662480 (V, A, ohm, ...), Measured Value = 124.685993 (C, atm, Hz, ...) 08:31:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092934 V 08:31:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092934 (V, A, ohm, ...), Measured Value = 6.970043 (C, atm, Hz, ...) 08:31:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.84 P3 = Magnet Core, Value = 26.29 P4 = Ambient Temp (C), Value = 19.16 P5 = Supply Temp(C), Value = 28.25 P6 = Return Temp(C), Value = 30.40 P7 = Supply Pres(psi), Value = 124.69 P8 = Return Pres(psi), Value = 6.97 08:32:01 Magnet Current for MAIN, Imag = 199.9901 A Vtrans = 1.999838 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:32:02 MAIN (V) Voltage Measurement, V = 14.284963 V 08:32:03 Temperature Measurement, Probe Number = 0, T = 27.851000 C 08:32:03 Temperature Measurement, Probe Number = 1, T = 26.335000 C 08:32:04 Temperature Measurement, Probe Number = 2, T = 19.074000 C 08:32:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.313927 V 08:32:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.313927 (V, A, ohm, ...), Measured Value = 28.248983 (C, atm, Hz, ...) 08:32:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.470264 V 08:32:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.470264 (V, A, ohm, ...), Measured Value = 30.420333 (C, atm, Hz, ...) 08:32:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660417 V 08:32:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660417 (V, A, ohm, ...), Measured Value = 124.531275 (C, atm, Hz, ...) 08:32:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093104 V 08:32:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093104 (V, A, ohm, ...), Measured Value = 6.982815 (C, atm, Hz, ...) 08:32:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.28 P2 = Coil, Value = 27.85 P3 = Magnet Core, Value = 26.34 P4 = Ambient Temp (C), Value = 19.07 P5 = Supply Temp(C), Value = 28.25 P6 = Return Temp(C), Value = 30.42 P7 = Supply Pres(psi), Value = 124.53 P8 = Return Pres(psi), Value = 6.98 08:33:07 Magnet Current for MAIN, Imag = 199.9903 A Vtrans = 1.999840 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:33:08 MAIN (V) Voltage Measurement, V = 14.285295 V 08:33:09 Temperature Measurement, Probe Number = 0, T = 27.868000 C 08:33:09 Temperature Measurement, Probe Number = 1, T = 26.349000 C 08:33:10 Temperature Measurement, Probe Number = 2, T = 19.104000 C 08:33:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.314276 V 08:33:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.314276 (V, A, ohm, ...), Measured Value = 28.253839 (C, atm, Hz, ...) 08:33:11 Sensor Voltage Measurement, Sensor Number = 1, V = 2.471947 V 08:33:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.471947 (V, A, ohm, ...), Measured Value = 30.443707 (C, atm, Hz, ...) 08:33:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667667 V 08:33:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667667 (V, A, ohm, ...), Measured Value = 125.075040 (C, atm, Hz, ...) 08:33:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092868 V 08:33:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092868 (V, A, ohm, ...), Measured Value = 6.965085 (C, atm, Hz, ...) 08:33:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.29 P2 = Coil, Value = 27.87 P3 = Magnet Core, Value = 26.35 P4 = Ambient Temp (C), Value = 19.10 P5 = Supply Temp(C), Value = 28.25 P6 = Return Temp(C), Value = 30.44 P7 = Supply Pres(psi), Value = 125.08 P8 = Return Pres(psi), Value = 6.97 08:34:13 Magnet Current for MAIN, Imag = 199.9903 A Vtrans = 1.999840 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:34:14 MAIN (V) Voltage Measurement, V = 14.285269 V 08:34:14 Temperature Measurement, Probe Number = 0, T = 27.913000 C 08:34:15 Temperature Measurement, Probe Number = 1, T = 26.369000 C 08:34:16 Temperature Measurement, Probe Number = 2, T = 19.151000 C 08:34:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.313724 V 08:34:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.313724 (V, A, ohm, ...), Measured Value = 28.246160 (C, atm, Hz, ...) 08:34:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.473590 V 08:34:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.473590 (V, A, ohm, ...), Measured Value = 30.466533 (C, atm, Hz, ...) 08:34:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656952 V 08:34:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656952 (V, A, ohm, ...), Measured Value = 124.271400 (C, atm, Hz, ...) 08:34:18 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093084 V 08:34:18 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093084 (V, A, ohm, ...), Measured Value = 6.981285 (C, atm, Hz, ...) 08:34:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.29 P2 = Coil, Value = 27.91 P3 = Magnet Core, Value = 26.37 P4 = Ambient Temp (C), Value = 19.15 P5 = Supply Temp(C), Value = 28.25 P6 = Return Temp(C), Value = 30.47 P7 = Supply Pres(psi), Value = 124.27 P8 = Return Pres(psi), Value = 6.98 08:35:19 Magnet Current for MAIN, Imag = 199.9904 A Vtrans = 1.999841 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 08:35:20 MAIN (V) Voltage Measurement, V = 14.285422 V 08:35:20 Temperature Measurement, Probe Number = 0, T = 27.893000 C 08:35:21 Temperature Measurement, Probe Number = 1, T = 26.392000 C 08:35:22 Temperature Measurement, Probe Number = 2, T = 19.103000 C 08:35:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.314308 V 08:35:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.314308 (V, A, ohm, ...), Measured Value = 28.254281 (C, atm, Hz, ...) 08:35:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.474835 V 08:35:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.474835 (V, A, ohm, ...), Measured Value = 30.483817 (C, atm, Hz, ...) 08:35:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662577 V 08:35:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662577 (V, A, ohm, ...), Measured Value = 124.693238 (C, atm, Hz, ...) 08:35:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092738 V 08:35:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092738 (V, A, ohm, ...), Measured Value = 6.955358 (C, atm, Hz, ...) 08:35:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 199.99 P1 = MAIN (V), Value = 14.29 P2 = Coil, Value = 27.89 P3 = Magnet Core, Value = 26.39 P4 = Ambient Temp (C), Value = 19.10 P5 = Supply Temp(C), Value = 28.25 P6 = Return Temp(C), Value = 30.48 P7 = Supply Pres(psi), Value = 124.69 P8 = Return Pres(psi), Value = 6.96 08:35:24 Magnet system MAIN current ramping to 0.0000 A... 08:37:27 Magnet system MAIN current ramping to 200.0000 A... 08:39:29 Magnet system MAIN current ramping to 0.0000 A... 08:41:31 Magnet system MAIN current ramping to 200.0000 A... 08:43:33 Magnet system MAIN current ramping to 0.0000 A... 08:45:36 Magnet system MAIN current ramping to 200.0000 A... 08:47:38 Magnet system MAIN current ramping to 0.0000 A... 08:49:40 Magnet system MAIN current ramping to 200.0000 A... 08:51:43 Magnet system MAIN current ramping to 0.0000 A... 08:53:45 Magnet system MAIN current ramping to 200.0000 A... 08:55:47 Magnet system MAIN current ramping to 0.0000 A... 08:57:50 Magnet system MAIN current ramping to 200.0000 A... 08:59:52 Magnet system MAIN current ramping to 0.0000 A... 09:01:54 Magnet system MAIN current ramping to 200.0000 A... 09:03:57 Magnet system MAIN current ramping to 0.0000 A... 09:05:59 Magnet system MAIN current ramping to 200.0000 A... 09:08:01 Magnet system MAIN current ramping to 0.0000 A... 09:10:04 Magnet system MAIN current ramping to 200.0000 A... 09:12:06 Magnet system MAIN current ramping to 0.0000 A... 09:14:08 Magnet system MAIN current ramping to 200.0000 A... 09:16:10 Magnet system MAIN current ramping to 0.0000 A... 09:18:16 Position moved: 0.000000 m 09:18:18 Magnet system MAIN current ramping to 0.0000 A... 09:18:29 Magnet Current for MAIN, Imag = 0.0096 A Vtrans = 0.000033 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:18:30 MAIN (V) Voltage Measurement, V = 0.000621 V 09:18:31 Temperature Measurement, Probe Number = 0, T = 27.211000 C 09:18:31 Temperature Measurement, Probe Number = 1, T = 26.360000 C 09:18:32 Temperature Measurement, Probe Number = 2, T = 19.340000 C 09:18:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.316704 V 09:18:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.316704 (V, A, ohm, ...), Measured Value = 28.287557 (C, atm, Hz, ...) 09:18:33 Sensor Voltage Measurement, Sensor Number = 1, V = 2.333393 V 09:18:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333393 (V, A, ohm, ...), Measured Value = 28.519351 (C, atm, Hz, ...) 09:18:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661191 V 09:18:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661191 (V, A, ohm, ...), Measured Value = 124.589332 (C, atm, Hz, ...) 09:18:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092555 V 09:18:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092555 (V, A, ohm, ...), Measured Value = 6.941632 (C, atm, Hz, ...) 09:18:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.01 P1 = MAIN (V), Value = 0.00 P2 = Coil, Value = 27.21 P3 = Magnet Core, Value = 26.36 P4 = Ambient Temp (C), Value = 19.34 P5 = Supply Temp(C), Value = 28.29 P6 = Return Temp(C), Value = 28.52 P7 = Supply Pres(psi), Value = 124.59 P8 = Return Pres(psi), Value = 6.94 09:18:35 Magnetic Field Measurement Measuring the magnet strength... 09:18:35 Integrated Voltage Measurement... 09:18:35 Magnet Current for MAIN, Imag = 0.0100 A Vtrans = 0.000037 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:18:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000502363 Vs 09:18:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000535659 Vs 09:18:53 Magnet Current for MAIN, Imag = 0.0096 A Vtrans = 0.000033 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:19:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000498831 Vs 09:19:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000532693 Vs 09:19:09 Magnet Current for MAIN, Imag = 0.0097 A Vtrans = 0.000034 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:19:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000504099 Vs 09:19:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000528695 Vs 09:19:26 Magnet Current for MAIN, Imag = 0.0098 A Vtrans = 0.000035 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:19:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000507605 Vs 09:19:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000527255 Vs 09:19:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000517150 +- 0.000001228 Vs 09:19:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.000517150 +- 0.000001228 Vs BL = -0.00574611 +- 0.00001365 Tm 09:19:46 Position moved: 0.000000 m 09:19:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00575 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00575 0.00001 -0.00575 0.00000 09:19:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00575 0.00001 SL = -0.0057461 +- 0.0000136 Tm^2/m^n 09:19:46 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0057461 +- 0.0000136 Tm^2/m^n 09:19:49 Position moved: 0.000000 m 09:19:49 Magnet system MAIN current ramping to 10.0000 A... 09:20:05 Magnet Current for MAIN, Imag = 9.9891 A Vtrans = 0.099828 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:20:06 MAIN (V) Voltage Measurement, V = 0.705435 V 09:20:06 Temperature Measurement, Probe Number = 0, T = 26.945000 C 09:20:07 Temperature Measurement, Probe Number = 1, T = 26.374000 C 09:20:08 Temperature Measurement, Probe Number = 2, T = 19.350000 C 09:20:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.316755 V 09:20:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.316755 (V, A, ohm, ...), Measured Value = 28.288264 (C, atm, Hz, ...) 09:20:09 Sensor Voltage Measurement, Sensor Number = 1, V = 2.328969 V 09:20:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328969 (V, A, ohm, ...), Measured Value = 28.457899 (C, atm, Hz, ...) 09:20:10 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662001 V 09:20:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662001 (V, A, ohm, ...), Measured Value = 124.650053 (C, atm, Hz, ...) 09:20:10 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092617 V 09:20:10 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092617 (V, A, ohm, ...), Measured Value = 6.946305 (C, atm, Hz, ...) 09:20:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 9.99 P1 = MAIN (V), Value = 0.71 P2 = Coil, Value = 26.95 P3 = Magnet Core, Value = 26.37 P4 = Ambient Temp (C), Value = 19.35 P5 = Supply Temp(C), Value = 28.29 P6 = Return Temp(C), Value = 28.46 P7 = Supply Pres(psi), Value = 124.65 P8 = Return Pres(psi), Value = 6.95 09:20:10 Magnetic Field Measurement Measuring the magnet strength... 09:20:10 Integrated Voltage Measurement... 09:20:11 Magnet Current for MAIN, Imag = 9.9891 A Vtrans = 0.099828 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:20:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.005044320 Vs 09:20:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.005080869 Vs 09:20:28 Magnet Current for MAIN, Imag = 9.9888 A Vtrans = 0.099825 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:20:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.005042905 Vs 09:20:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.005081844 Vs 09:20:45 Magnet Current for MAIN, Imag = 9.9890 A Vtrans = 0.099827 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:20:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.005047083 Vs 09:21:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.005083216 Vs 09:21:01 Magnet Current for MAIN, Imag = 9.9889 A Vtrans = 0.099826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:21:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.005046982 Vs 09:21:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.005077618 Vs 09:21:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.005063105 +- 0.000001186 Vs 09:21:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.005063105 +- 0.000001186 Vs BL = -0.05625672 +- 0.00001317 Tm 09:21:21 Position moved: 0.000000 m 09:21:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05626 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05626 0.00001 -0.05626 0.00000 09:21:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05626 0.00001 SL = -0.0562567 +- 0.0000132 Tm^2/m^n 09:21:21 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0562567 +- 0.0000132 Tm^2/m^n Remeasure 09:21:21 Magnetic Field Measurement Measuring the magnet strength... 09:21:21 Integrated Voltage Measurement... 09:21:22 Magnet Current for MAIN, Imag = 9.9890 A Vtrans = 0.099827 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:21:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.005043512 Vs 09:21:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.005085323 Vs 09:21:40 Magnet Current for MAIN, Imag = 9.9889 A Vtrans = 0.099826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:21:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.005047006 Vs 09:21:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.005078608 Vs 09:21:57 Magnet Current for MAIN, Imag = 9.9889 A Vtrans = 0.099826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:22:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.005051756 Vs 09:22:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.005069911 Vs 09:22:13 Magnet Current for MAIN, Imag = 9.9888 A Vtrans = 0.099825 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:22:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.005060647 Vs 09:22:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.005064853 Vs 09:22:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.005062702 +- 0.000001270 Vs 09:22:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.005062702 +- 0.000001270 Vs BL = -0.05625224 +- 0.00001411 Tm 09:22:33 Position moved: 0.000000 m 09:22:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05625 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05625 0.00001 -0.05625 0.00000 09:22:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05625 0.00001 SL = -0.0562522 +- 0.0000141 Tm^2/m^n 09:22:33 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0562522 +- 0.0000141 Tm^2/m^n 09:22:35 Position moved: 0.000000 m 09:22:35 Magnet system MAIN current ramping to 20.0000 A... 09:22:52 Magnet Current for MAIN, Imag = 19.9762 A Vtrans = 0.199698 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:22:53 MAIN (V) Voltage Measurement, V = 1.410005 V 09:22:53 Temperature Measurement, Probe Number = 0, T = 26.775000 C 09:22:54 Temperature Measurement, Probe Number = 1, T = 26.330000 C 09:22:55 Temperature Measurement, Probe Number = 2, T = 19.493000 C 09:22:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317457 V 09:22:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317457 (V, A, ohm, ...), Measured Value = 28.298008 (C, atm, Hz, ...) 09:22:56 Sensor Voltage Measurement, Sensor Number = 1, V = 2.299806 V 09:22:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.299806 (V, A, ohm, ...), Measured Value = 28.052867 (C, atm, Hz, ...) 09:22:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664769 V 09:22:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664769 (V, A, ohm, ...), Measured Value = 124.857682 (C, atm, Hz, ...) 09:22:57 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092545 V 09:22:57 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092545 (V, A, ohm, ...), Measured Value = 6.940868 (C, atm, Hz, ...) 09:22:57 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.98 P1 = MAIN (V), Value = 1.41 P2 = Coil, Value = 26.77 P3 = Magnet Core, Value = 26.33 P4 = Ambient Temp (C), Value = 19.49 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 28.05 P7 = Supply Pres(psi), Value = 124.86 P8 = Return Pres(psi), Value = 6.94 09:22:57 Magnetic Field Measurement Measuring the magnet strength... 09:22:57 Integrated Voltage Measurement... 09:22:58 Magnet Current for MAIN, Imag = 19.9764 A Vtrans = 0.199701 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:23:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009669194 Vs 09:23:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009662901 Vs 09:23:16 Magnet Current for MAIN, Imag = 19.9765 A Vtrans = 0.199702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:23:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009661797 Vs 09:23:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009664166 Vs 09:23:32 Magnet Current for MAIN, Imag = 19.9765 A Vtrans = 0.199702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:23:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009651824 Vs 09:23:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009665159 Vs 09:23:49 Magnet Current for MAIN, Imag = 19.9763 A Vtrans = 0.199700 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:23:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009654369 Vs 09:24:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009664808 Vs 09:24:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009661777 +- 0.000002969 Vs 09:24:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.009661777 +- 0.000002969 Vs BL = -0.10735308 +- 0.00003299 Tm 09:24:09 Position moved: 0.000000 m 09:24:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10735 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10735 0.00003 -0.10735 0.00000 09:24:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10735 0.00003 SL = -0.1073531 +- 0.0000330 Tm^2/m^n 09:24:09 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1073531 +- 0.0000330 Tm^2/m^n Remeasure 09:24:09 Magnetic Field Measurement Measuring the magnet strength... 09:24:09 Integrated Voltage Measurement... 09:24:10 Magnet Current for MAIN, Imag = 19.9762 A Vtrans = 0.199699 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:24:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009642847 Vs 09:24:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009672548 Vs 09:24:27 Magnet Current for MAIN, Imag = 19.9761 A Vtrans = 0.199698 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:24:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009650762 Vs 09:24:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009673722 Vs 09:24:44 Magnet Current for MAIN, Imag = 19.9761 A Vtrans = 0.199698 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:24:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009646557 Vs 09:25:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009675989 Vs 09:25:00 Magnet Current for MAIN, Imag = 19.9760 A Vtrans = 0.199697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:25:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009657443 Vs 09:25:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009665269 Vs 09:25:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009660642 +- 0.000001742 Vs 09:25:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.009660642 +- 0.000001742 Vs BL = -0.10734047 +- 0.00001936 Tm 09:25:20 Position moved: 0.000000 m 09:25:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10734 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10734 0.00002 -0.10734 0.00000 09:25:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10734 0.00002 SL = -0.1073405 +- 0.0000194 Tm^2/m^n 09:25:20 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1073405 +- 0.0000194 Tm^2/m^n 09:25:23 Position moved: 0.000000 m 09:25:23 Magnet system MAIN current ramping to 30.0000 A... 09:25:40 Magnet Current for MAIN, Imag = 29.9643 A Vtrans = 0.299580 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:25:40 MAIN (V) Voltage Measurement, V = 2.115068 V 09:25:41 Temperature Measurement, Probe Number = 0, T = 26.777000 C 09:25:41 Temperature Measurement, Probe Number = 1, T = 26.340000 C 09:25:42 Temperature Measurement, Probe Number = 2, T = 19.481000 C 09:25:43 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317724 V 09:25:43 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317724 (V, A, ohm, ...), Measured Value = 28.301715 (C, atm, Hz, ...) 09:25:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.273197 V 09:25:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.273197 (V, A, ohm, ...), Measured Value = 27.683285 (C, atm, Hz, ...) 09:25:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659443 V 09:25:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659443 (V, A, ohm, ...), Measured Value = 124.458247 (C, atm, Hz, ...) 09:25:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092222 V 09:25:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092222 (V, A, ohm, ...), Measured Value = 6.916658 (C, atm, Hz, ...) 09:25:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 29.96 P1 = MAIN (V), Value = 2.12 P2 = Coil, Value = 26.78 P3 = Magnet Core, Value = 26.34 P4 = Ambient Temp (C), Value = 19.48 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 27.68 P7 = Supply Pres(psi), Value = 124.46 P8 = Return Pres(psi), Value = 6.92 09:25:45 Magnetic Field Measurement Measuring the magnet strength... 09:25:45 Integrated Voltage Measurement... 09:25:46 Magnet Current for MAIN, Imag = 29.9643 A Vtrans = 0.299580 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:25:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014283382 Vs 09:26:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014274764 Vs 09:26:03 Magnet Current for MAIN, Imag = 29.9642 A Vtrans = 0.299579 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:26:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014289086 Vs 09:26:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014266204 Vs 09:26:20 Magnet Current for MAIN, Imag = 29.9642 A Vtrans = 0.299579 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:26:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014287211 Vs 09:26:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014274695 Vs 09:26:36 Magnet Current for MAIN, Imag = 29.9644 A Vtrans = 0.299580 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:26:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014278619 Vs 09:26:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014280921 Vs 09:26:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014279360 +- 0.000001197 Vs 09:26:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014279360 +- 0.000001197 Vs BL = -0.15865956 +- 0.00001330 Tm 09:26:56 Position moved: 0.000000 m 09:26:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.15866 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.15866 0.00001 -0.15866 0.00000 09:26:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.15866 0.00001 SL = -0.1586596 +- 0.0000133 Tm^2/m^n 09:26:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1586596 +- 0.0000133 Tm^2/m^n 09:26:59 Position moved: 0.000000 m 09:26:59 Magnet system MAIN current ramping to 40.0000 A... 09:27:15 Magnet Current for MAIN, Imag = 39.9610 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:27:16 MAIN (V) Voltage Measurement, V = 2.821032 V 09:27:17 Temperature Measurement, Probe Number = 0, T = 26.834000 C 09:27:17 Temperature Measurement, Probe Number = 1, T = 26.324000 C 09:27:18 Temperature Measurement, Probe Number = 2, T = 19.436000 C 09:27:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317507 V 09:27:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317507 (V, A, ohm, ...), Measured Value = 28.298714 (C, atm, Hz, ...) 09:27:19 Sensor Voltage Measurement, Sensor Number = 1, V = 2.263088 V 09:27:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.263088 (V, A, ohm, ...), Measured Value = 27.542883 (C, atm, Hz, ...) 09:27:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658518 V 09:27:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658518 (V, A, ohm, ...), Measured Value = 124.388850 (C, atm, Hz, ...) 09:27:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092270 V 09:27:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092270 (V, A, ohm, ...), Measured Value = 6.920280 (C, atm, Hz, ...) 09:27:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.96 P1 = MAIN (V), Value = 2.82 P2 = Coil, Value = 26.83 P3 = Magnet Core, Value = 26.32 P4 = Ambient Temp (C), Value = 19.44 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 27.54 P7 = Supply Pres(psi), Value = 124.39 P8 = Return Pres(psi), Value = 6.92 09:27:21 Magnetic Field Measurement Measuring the magnet strength... 09:27:21 Integrated Voltage Measurement... 09:27:21 Magnet Current for MAIN, Imag = 39.9609 A Vtrans = 0.399546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:27:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018912538 Vs 09:27:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018921322 Vs 09:27:39 Magnet Current for MAIN, Imag = 39.9610 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:27:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018908420 Vs 09:27:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018917090 Vs 09:27:56 Magnet Current for MAIN, Imag = 39.9608 A Vtrans = 0.399545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:28:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018911974 Vs 09:28:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018917577 Vs 09:28:12 Magnet Current for MAIN, Imag = 39.9608 A Vtrans = 0.399545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:28:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018915779 Vs 09:28:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018896608 Vs 09:28:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018912664 +- 0.000004017 Vs 09:28:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.018912664 +- 0.000004017 Vs BL = -0.21014071 +- 0.00004463 Tm 09:28:32 Position moved: 0.000000 m 09:28:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.21014 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.21014 0.00004 -0.21014 0.00000 09:28:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.21014 0.00004 SL = -0.2101407 +- 0.0000446 Tm^2/m^n 09:28:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2101407 +- 0.0000446 Tm^2/m^n Remeasure 09:28:32 Magnetic Field Measurement Measuring the magnet strength... 09:28:32 Integrated Voltage Measurement... 09:28:33 Magnet Current for MAIN, Imag = 39.9611 A Vtrans = 0.399548 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:28:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018941096 Vs 09:28:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018900737 Vs 09:28:50 Magnet Current for MAIN, Imag = 39.9611 A Vtrans = 0.399548 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:28:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018931411 Vs 09:29:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018903343 Vs 09:29:06 Magnet Current for MAIN, Imag = 39.9612 A Vtrans = 0.399549 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:29:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018925184 Vs 09:29:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018914002 Vs 09:29:23 Magnet Current for MAIN, Imag = 39.9612 A Vtrans = 0.399549 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:29:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018929431 Vs 09:29:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.018912150 Vs 09:29:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.018919669 +- 0.000001421 Vs 09:29:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.018919669 +- 0.000001421 Vs BL = -0.21021855 +- 0.00001579 Tm 09:29:43 Position moved: 0.000000 m 09:29:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.21022 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.21022 0.00002 -0.21022 0.00000 09:29:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.21022 0.00002 SL = -0.2102185 +- 0.0000158 Tm^2/m^n 09:29:43 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2102185 +- 0.0000158 Tm^2/m^n 09:29:46 Position moved: 0.000000 m 09:29:46 Magnet system MAIN current ramping to 50.0000 A... 09:30:03 Magnet Current for MAIN, Imag = 49.9470 A Vtrans = 0.499407 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:30:03 MAIN (V) Voltage Measurement, V = 3.526706 V 09:30:04 Temperature Measurement, Probe Number = 0, T = 26.856000 C 09:30:04 Temperature Measurement, Probe Number = 1, T = 26.295000 C 09:30:05 Temperature Measurement, Probe Number = 2, T = 19.470000 C 09:30:06 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317666 V 09:30:06 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317666 (V, A, ohm, ...), Measured Value = 28.300921 (C, atm, Hz, ...) 09:30:06 Sensor Voltage Measurement, Sensor Number = 1, V = 2.252298 V 09:30:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.252298 (V, A, ohm, ...), Measured Value = 27.393021 (C, atm, Hz, ...) 09:30:07 Sensor Voltage Measurement, Sensor Number = 2, V = 2.666891 V 09:30:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666891 (V, A, ohm, ...), Measured Value = 125.016795 (C, atm, Hz, ...) 09:30:08 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092221 V 09:30:08 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092221 (V, A, ohm, ...), Measured Value = 6.916560 (C, atm, Hz, ...) 09:30:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 49.95 P1 = MAIN (V), Value = 3.53 P2 = Coil, Value = 26.86 P3 = Magnet Core, Value = 26.30 P4 = Ambient Temp (C), Value = 19.47 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 27.39 P7 = Supply Pres(psi), Value = 125.02 P8 = Return Pres(psi), Value = 6.92 09:30:08 Magnetic Field Measurement Measuring the magnet strength... 09:30:08 Integrated Voltage Measurement... 09:30:09 Magnet Current for MAIN, Imag = 49.9471 A Vtrans = 0.499408 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:30:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023573104 Vs 09:30:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023545446 Vs 09:30:26 Magnet Current for MAIN, Imag = 49.9471 A Vtrans = 0.499408 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:30:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023565117 Vs 09:30:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023543980 Vs 09:30:43 Magnet Current for MAIN, Imag = 49.9472 A Vtrans = 0.499409 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:30:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023585915 Vs 09:30:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023541620 Vs 09:30:59 Magnet Current for MAIN, Imag = 49.9472 A Vtrans = 0.499409 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:31:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023583685 Vs 09:31:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023529971 Vs 09:31:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023558605 +- 0.000003418 Vs 09:31:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.023558605 +- 0.000003418 Vs BL = -0.26176228 +- 0.00003797 Tm 09:31:19 Position moved: 0.000000 m 09:31:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.26176 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.26176 0.00004 -0.26176 0.00000 09:31:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.26176 0.00004 SL = -0.2617623 +- 0.0000380 Tm^2/m^n 09:31:19 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2617623 +- 0.0000380 Tm^2/m^n 09:31:22 Position moved: 0.000000 m 09:31:22 Magnet system MAIN current ramping to 60.0000 A... 09:31:38 Magnet Current for MAIN, Imag = 59.9373 A Vtrans = 0.599310 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:31:39 MAIN (V) Voltage Measurement, V = 4.233007 V 09:31:40 Temperature Measurement, Probe Number = 0, T = 26.877000 C 09:31:40 Temperature Measurement, Probe Number = 1, T = 26.268000 C 09:31:41 Temperature Measurement, Probe Number = 2, T = 19.482000 C 09:31:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317987 V 09:31:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317987 (V, A, ohm, ...), Measured Value = 28.305369 (C, atm, Hz, ...) 09:31:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.247724 V 09:31:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.247724 (V, A, ohm, ...), Measured Value = 27.329501 (C, atm, Hz, ...) 09:31:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661599 V 09:31:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661599 (V, A, ohm, ...), Measured Value = 124.619933 (C, atm, Hz, ...) 09:31:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092364 V 09:31:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092364 (V, A, ohm, ...), Measured Value = 6.927330 (C, atm, Hz, ...) 09:31:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 59.94 P1 = MAIN (V), Value = 4.23 P2 = Coil, Value = 26.88 P3 = Magnet Core, Value = 26.27 P4 = Ambient Temp (C), Value = 19.48 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 27.33 P7 = Supply Pres(psi), Value = 124.62 P8 = Return Pres(psi), Value = 6.93 09:31:44 Magnetic Field Measurement Measuring the magnet strength... 09:31:44 Integrated Voltage Measurement... 09:31:44 Magnet Current for MAIN, Imag = 59.9372 A Vtrans = 0.599309 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:31:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028221249 Vs 09:32:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028214231 Vs 09:32:02 Magnet Current for MAIN, Imag = 59.9373 A Vtrans = 0.599310 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:32:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028212863 Vs 09:32:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028214933 Vs 09:32:18 Magnet Current for MAIN, Imag = 59.9373 A Vtrans = 0.599310 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:32:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028252056 Vs 09:32:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028215073 Vs 09:32:35 Magnet Current for MAIN, Imag = 59.9373 A Vtrans = 0.599310 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:32:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028250811 Vs 09:32:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028217223 Vs 09:32:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028224805 +- 0.000009089 Vs 09:32:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.028224805 +- 0.000009089 Vs BL = -0.31360894 +- 0.00010099 Tm 09:32:55 Position moved: 0.000000 m 09:32:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.31361 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.31361 0.00010 -0.31361 0.00000 09:32:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.31361 0.00010 SL = -0.3136089 +- 0.0001010 Tm^2/m^n 09:32:55 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3136089 +- 0.0001010 Tm^2/m^n Remeasure 09:32:55 Magnetic Field Measurement Measuring the magnet strength... 09:32:55 Integrated Voltage Measurement... 09:32:56 Magnet Current for MAIN, Imag = 59.9374 A Vtrans = 0.599311 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:33:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028223801 Vs 09:33:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028185366 Vs 09:33:13 Magnet Current for MAIN, Imag = 59.9373 A Vtrans = 0.599310 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:33:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028215570 Vs 09:33:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028225669 Vs 09:33:29 Magnet Current for MAIN, Imag = 59.9374 A Vtrans = 0.599311 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:33:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028238684 Vs 09:33:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028194871 Vs 09:33:46 Magnet Current for MAIN, Imag = 59.9376 A Vtrans = 0.599313 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:33:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028229284 Vs 09:34:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028206099 Vs 09:34:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028214918 +- 0.000006133 Vs 09:34:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.028214918 +- 0.000006133 Vs BL = -0.31349909 +- 0.00006814 Tm 09:34:06 Position moved: 0.000000 m 09:34:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.31350 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.31350 0.00007 -0.31350 0.00000 09:34:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.31350 0.00007 SL = -0.3134991 +- 0.0000681 Tm^2/m^n 09:34:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3134991 +- 0.0000681 Tm^2/m^n Remeasure 09:34:06 Magnetic Field Measurement Measuring the magnet strength... 09:34:06 Integrated Voltage Measurement... 09:34:06 Magnet Current for MAIN, Imag = 59.9377 A Vtrans = 0.599314 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:34:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028230773 Vs 09:34:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028226424 Vs 09:34:24 Magnet Current for MAIN, Imag = 59.9377 A Vtrans = 0.599314 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:34:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028228594 Vs 09:34:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028224116 Vs 09:34:41 Magnet Current for MAIN, Imag = 59.9377 A Vtrans = 0.599314 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:34:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028212148 Vs 09:34:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028238229 Vs 09:34:57 Magnet Current for MAIN, Imag = 59.9374 A Vtrans = 0.599311 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:35:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028205293 Vs 09:35:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028221960 Vs 09:35:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028223442 +- 0.000005798 Vs 09:35:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.028223442 +- 0.000005798 Vs BL = -0.31359380 +- 0.00006442 Tm 09:35:17 Position moved: 0.000000 m 09:35:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.31359 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.31359 0.00006 -0.31359 0.00000 09:35:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.31359 0.00006 SL = -0.3135938 +- 0.0000644 Tm^2/m^n 09:35:17 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3135938 +- 0.0000644 Tm^2/m^n 09:35:20 Position moved: 0.000000 m 09:35:20 Magnet system MAIN current ramping to 70.0000 A... 09:35:36 Magnet Current for MAIN, Imag = 69.9286 A Vtrans = 0.699223 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:35:37 MAIN (V) Voltage Measurement, V = 4.940406 V 09:35:38 Temperature Measurement, Probe Number = 0, T = 26.938000 C 09:35:38 Temperature Measurement, Probe Number = 1, T = 26.247000 C 09:35:39 Temperature Measurement, Probe Number = 2, T = 19.501000 C 09:35:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318754 V 09:35:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318754 (V, A, ohm, ...), Measured Value = 28.316033 (C, atm, Hz, ...) 09:35:40 Sensor Voltage Measurement, Sensor Number = 1, V = 2.240582 V 09:35:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.240582 (V, A, ohm, ...), Measured Value = 27.230306 (C, atm, Hz, ...) 09:35:41 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665720 V 09:35:41 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665720 (V, A, ohm, ...), Measured Value = 124.928993 (C, atm, Hz, ...) 09:35:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092377 V 09:35:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092377 (V, A, ohm, ...), Measured Value = 6.928282 (C, atm, Hz, ...) 09:35:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 69.93 P1 = MAIN (V), Value = 4.94 P2 = Coil, Value = 26.94 P3 = Magnet Core, Value = 26.25 P4 = Ambient Temp (C), Value = 19.50 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 27.23 P7 = Supply Pres(psi), Value = 124.93 P8 = Return Pres(psi), Value = 6.93 09:35:42 Magnetic Field Measurement Measuring the magnet strength... 09:35:42 Integrated Voltage Measurement... 09:35:43 Magnet Current for MAIN, Imag = 69.9285 A Vtrans = 0.699222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:35:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.032872723 Vs 09:35:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.032924173 Vs 09:36:00 Magnet Current for MAIN, Imag = 69.9285 A Vtrans = 0.699222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:36:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.032891623 Vs 09:36:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.032885087 Vs 09:36:17 Magnet Current for MAIN, Imag = 69.9287 A Vtrans = 0.699224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:36:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.032881209 Vs 09:36:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.032883706 Vs 09:36:33 Magnet Current for MAIN, Imag = 69.9287 A Vtrans = 0.699224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:36:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.032877897 Vs 09:36:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.032920999 Vs 09:36:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.032892177 +- 0.000007094 Vs 09:36:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.032892177 +- 0.000007094 Vs BL = -0.36546863 +- 0.00007882 Tm 09:36:53 Position moved: 0.000000 m 09:36:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.36547 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.36547 0.00008 -0.36547 0.00000 09:36:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.36547 0.00008 SL = -0.3654686 +- 0.0000788 Tm^2/m^n 09:36:53 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3654686 +- 0.0000788 Tm^2/m^n Remeasure 09:36:53 Magnetic Field Measurement Measuring the magnet strength... 09:36:53 Integrated Voltage Measurement... 09:36:54 Magnet Current for MAIN, Imag = 69.9288 A Vtrans = 0.699225 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:37:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.032873130 Vs 09:37:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.032898794 Vs 09:37:12 Magnet Current for MAIN, Imag = 69.9289 A Vtrans = 0.699226 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:37:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.032880353 Vs 09:37:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.032886125 Vs 09:37:28 Magnet Current for MAIN, Imag = 69.9292 A Vtrans = 0.699229 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:37:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.032921167 Vs 09:37:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.032867522 Vs 09:37:45 Magnet Current for MAIN, Imag = 69.9291 A Vtrans = 0.699228 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:37:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.032901880 Vs 09:38:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.032843787 Vs 09:38:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.032884095 +- 0.000007683 Vs 09:38:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.032884095 +- 0.000007683 Vs BL = -0.36537883 +- 0.00008536 Tm 09:38:04 Position moved: 0.000000 m 09:38:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.36538 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.36538 0.00009 -0.36538 0.00000 09:38:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.36538 0.00009 SL = -0.3653788 +- 0.0000854 Tm^2/m^n 09:38:05 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3653788 +- 0.0000854 Tm^2/m^n 09:38:07 Position moved: 0.000000 m 09:38:07 Magnet system MAIN current ramping to 80.0000 A... 09:38:24 Magnet Current for MAIN, Imag = 79.9343 A Vtrans = 0.799280 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:38:25 MAIN (V) Voltage Measurement, V = 5.649596 V 09:38:25 Temperature Measurement, Probe Number = 0, T = 26.909000 C 09:38:26 Temperature Measurement, Probe Number = 1, T = 26.193000 C 09:38:27 Temperature Measurement, Probe Number = 2, T = 19.726000 C 09:38:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318571 V 09:38:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318571 (V, A, ohm, ...), Measured Value = 28.313490 (C, atm, Hz, ...) 09:38:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.238912 V 09:38:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.238912 (V, A, ohm, ...), Measured Value = 27.207108 (C, atm, Hz, ...) 09:38:28 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660047 V 09:38:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660047 (V, A, ohm, ...), Measured Value = 124.503532 (C, atm, Hz, ...) 09:38:29 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092148 V 09:38:29 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092148 (V, A, ohm, ...), Measured Value = 6.911123 (C, atm, Hz, ...) 09:38:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 79.93 P1 = MAIN (V), Value = 5.65 P2 = Coil, Value = 26.91 P3 = Magnet Core, Value = 26.19 P4 = Ambient Temp (C), Value = 19.73 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 27.21 P7 = Supply Pres(psi), Value = 124.50 P8 = Return Pres(psi), Value = 6.91 09:38:29 Magnetic Field Measurement Measuring the magnet strength... 09:38:29 Integrated Voltage Measurement... 09:38:30 Magnet Current for MAIN, Imag = 79.9343 A Vtrans = 0.799280 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:38:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037561650 Vs 09:38:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037560015 Vs 09:38:47 Magnet Current for MAIN, Imag = 79.9343 A Vtrans = 0.799280 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:38:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037604375 Vs 09:39:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037589460 Vs 09:39:04 Magnet Current for MAIN, Imag = 79.9341 A Vtrans = 0.799278 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:39:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037599820 Vs 09:39:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037590359 Vs 09:39:20 Magnet Current for MAIN, Imag = 79.9340 A Vtrans = 0.799277 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:39:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037559443 Vs 09:39:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037596152 Vs 09:39:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037582659 +- 0.000014645 Vs 09:39:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.037582659 +- 0.000014645 Vs BL = -0.41758510 +- 0.00016272 Tm 09:39:40 Position moved: 0.000000 m 09:39:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.41759 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.41759 0.00016 -0.41759 0.00000 09:39:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.41759 0.00016 SL = -0.4175851 +- 0.0001627 Tm^2/m^n 09:39:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4175851 +- 0.0001627 Tm^2/m^n Remeasure 09:39:40 Magnetic Field Measurement Measuring the magnet strength... 09:39:40 Integrated Voltage Measurement... 09:39:41 Magnet Current for MAIN, Imag = 79.9341 A Vtrans = 0.799278 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:39:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037562343 Vs 09:39:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037593174 Vs 09:39:59 Magnet Current for MAIN, Imag = 79.9341 A Vtrans = 0.799278 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:40:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037571783 Vs 09:40:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037620749 Vs 09:40:15 Magnet Current for MAIN, Imag = 79.9341 A Vtrans = 0.799278 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:40:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037520941 Vs 09:40:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037571927 Vs 09:40:32 Magnet Current for MAIN, Imag = 79.9339 A Vtrans = 0.799276 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:40:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037535087 Vs 09:40:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037576323 Vs 09:40:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037569041 +- 0.000019404 Vs 09:40:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.037569041 +- 0.000019404 Vs BL = -0.41743379 +- 0.00021560 Tm 09:40:52 Position moved: 0.000000 m 09:40:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.41743 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.41743 0.00022 -0.41743 0.00000 09:40:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.41743 0.00022 SL = -0.4174338 +- 0.0002156 Tm^2/m^n 09:40:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4174338 +- 0.0002156 Tm^2/m^n Remeasure 09:40:52 Magnetic Field Measurement Measuring the magnet strength... 09:40:52 Integrated Voltage Measurement... 09:40:52 Magnet Current for MAIN, Imag = 79.9338 A Vtrans = 0.799275 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:41:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037536124 Vs 09:41:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037563992 Vs 09:41:10 Magnet Current for MAIN, Imag = 79.9341 A Vtrans = 0.799278 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:41:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037565912 Vs 09:41:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037589396 Vs 09:41:27 Magnet Current for MAIN, Imag = 79.9337 A Vtrans = 0.799274 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:41:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037573327 Vs 09:41:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037590550 Vs 09:41:43 Magnet Current for MAIN, Imag = 79.9337 A Vtrans = 0.799274 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:41:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037578391 Vs 09:41:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037597620 Vs 09:41:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037574414 +- 0.000014535 Vs 09:41:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.037574414 +- 0.000014535 Vs BL = -0.41749349 +- 0.00016150 Tm 09:42:03 Position moved: 0.000000 m 09:42:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.41749 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.41749 0.00016 -0.41749 0.00000 09:42:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.41749 0.00016 SL = -0.4174935 +- 0.0001615 Tm^2/m^n 09:42:03 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4174935 +- 0.0001615 Tm^2/m^n Remeasure 09:42:03 Magnetic Field Measurement Measuring the magnet strength... 09:42:03 Integrated Voltage Measurement... 09:42:04 Magnet Current for MAIN, Imag = 79.9340 A Vtrans = 0.799277 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:42:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037579766 Vs 09:42:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037593920 Vs 09:42:22 Magnet Current for MAIN, Imag = 79.9341 A Vtrans = 0.799278 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:42:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037579959 Vs 09:42:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037579036 Vs 09:42:38 Magnet Current for MAIN, Imag = 79.9341 A Vtrans = 0.799278 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:42:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037573554 Vs 09:42:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037587455 Vs 09:42:55 Magnet Current for MAIN, Imag = 79.9342 A Vtrans = 0.799279 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:43:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037584572 Vs 09:43:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.037578201 Vs 09:43:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.037582058 +- 0.000002842 Vs 09:43:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.037582058 +- 0.000002842 Vs BL = -0.41757842 +- 0.00003158 Tm 09:43:14 Position moved: 0.000000 m 09:43:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.41758 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.41758 0.00003 -0.41758 0.00000 09:43:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.41758 0.00003 SL = -0.4175784 +- 0.0000316 Tm^2/m^n 09:43:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4175784 +- 0.0000316 Tm^2/m^n 09:43:18 Position moved: 0.000000 m 09:43:18 Magnet system MAIN current ramping to 90.0000 A... 09:43:34 Magnet Current for MAIN, Imag = 89.9978 A Vtrans = 0.899915 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:43:35 MAIN (V) Voltage Measurement, V = 6.364092 V 09:43:35 Temperature Measurement, Probe Number = 0, T = 26.940000 C 09:43:36 Temperature Measurement, Probe Number = 1, T = 26.197000 C 09:43:37 Temperature Measurement, Probe Number = 2, T = 19.388000 C 09:43:37 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318932 V 09:43:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318932 (V, A, ohm, ...), Measured Value = 28.318504 (C, atm, Hz, ...) 09:43:38 Sensor Voltage Measurement, Sensor Number = 1, V = 2.244962 V 09:43:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.244962 (V, A, ohm, ...), Measured Value = 27.291140 (C, atm, Hz, ...) 09:43:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.666723 V 09:43:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666723 (V, A, ohm, ...), Measured Value = 125.004210 (C, atm, Hz, ...) 09:43:39 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092404 V 09:43:39 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092404 (V, A, ohm, ...), Measured Value = 6.930285 (C, atm, Hz, ...) 09:43:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 90.00 P1 = MAIN (V), Value = 6.36 P2 = Coil, Value = 26.94 P3 = Magnet Core, Value = 26.20 P4 = Ambient Temp (C), Value = 19.39 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 27.29 P7 = Supply Pres(psi), Value = 125.00 P8 = Return Pres(psi), Value = 6.93 09:43:39 Magnetic Field Measurement Measuring the magnet strength... 09:43:39 Integrated Voltage Measurement... 09:43:40 Magnet Current for MAIN, Imag = 89.9980 A Vtrans = 0.899917 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:43:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042285173 Vs 09:43:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042308516 Vs 09:43:58 Magnet Current for MAIN, Imag = 89.9983 A Vtrans = 0.899920 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:44:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042284248 Vs 09:44:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042264422 Vs 09:44:14 Magnet Current for MAIN, Imag = 89.9985 A Vtrans = 0.899921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:44:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042301922 Vs 09:44:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042306946 Vs 09:44:31 Magnet Current for MAIN, Imag = 89.9981 A Vtrans = 0.899918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:44:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042274123 Vs 09:44:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042314321 Vs 09:44:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042292459 +- 0.000011116 Vs 09:44:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.042292459 +- 0.000011116 Vs BL = -0.46991621 +- 0.00012351 Tm 09:44:50 Position moved: 0.000000 m 09:44:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.46992 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.46992 0.00012 -0.46992 0.00000 09:44:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.46992 0.00012 SL = -0.4699162 +- 0.0001235 Tm^2/m^n 09:44:50 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4699162 +- 0.0001235 Tm^2/m^n Remeasure 09:44:50 Magnetic Field Measurement Measuring the magnet strength... 09:44:50 Integrated Voltage Measurement... 09:44:51 Magnet Current for MAIN, Imag = 89.9982 A Vtrans = 0.899919 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:45:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042308433 Vs 09:45:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042305027 Vs 09:45:09 Magnet Current for MAIN, Imag = 89.9981 A Vtrans = 0.899918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:45:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042267948 Vs 09:45:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042289208 Vs 09:45:26 Magnet Current for MAIN, Imag = 89.9983 A Vtrans = 0.899920 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:45:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042272328 Vs 09:45:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042304162 Vs 09:45:42 Magnet Current for MAIN, Imag = 89.9984 A Vtrans = 0.899921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:45:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042256305 Vs 09:45:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042305331 Vs 09:45:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042288593 +- 0.000011066 Vs 09:45:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.042288593 +- 0.000011066 Vs BL = -0.46987325 +- 0.00012296 Tm 09:46:02 Position moved: 0.000000 m 09:46:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.46987 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.46987 0.00012 -0.46987 0.00000 09:46:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.46987 0.00012 SL = -0.4698733 +- 0.0001230 Tm^2/m^n 09:46:02 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4698733 +- 0.0001230 Tm^2/m^n Remeasure 09:46:02 Magnetic Field Measurement Measuring the magnet strength... 09:46:02 Integrated Voltage Measurement... 09:46:03 Magnet Current for MAIN, Imag = 89.9984 A Vtrans = 0.899921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:46:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042282245 Vs 09:46:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042266954 Vs 09:46:20 Magnet Current for MAIN, Imag = 89.9985 A Vtrans = 0.899922 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:46:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042298213 Vs 09:46:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042294972 Vs 09:46:37 Magnet Current for MAIN, Imag = 89.9982 A Vtrans = 0.899919 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:46:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042292780 Vs 09:46:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042311761 Vs 09:46:53 Magnet Current for MAIN, Imag = 89.9986 A Vtrans = 0.899923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:47:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042304395 Vs 09:47:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042318121 Vs 09:47:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042296180 +- 0.000013512 Vs 09:47:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.042296180 +- 0.000013512 Vs BL = -0.46995756 +- 0.00015014 Tm 09:47:13 Position moved: 0.000000 m 09:47:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.46996 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.46996 0.00015 -0.46996 0.00000 09:47:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.46996 0.00015 SL = -0.4699576 +- 0.0001501 Tm^2/m^n 09:47:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4699576 +- 0.0001501 Tm^2/m^n 09:47:16 Position moved: 0.000000 m 09:47:16 Magnet system MAIN current ramping to 100.0000 A... 09:47:33 Magnet Current for MAIN, Imag = 99.9886 A Vtrans = 0.999823 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:47:33 MAIN (V) Voltage Measurement, V = 7.073717 V 09:47:34 Temperature Measurement, Probe Number = 0, T = 27.030000 C 09:47:35 Temperature Measurement, Probe Number = 1, T = 26.144000 C 09:47:35 Temperature Measurement, Probe Number = 2, T = 19.185000 C 09:47:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317736 V 09:47:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317736 (V, A, ohm, ...), Measured Value = 28.301892 (C, atm, Hz, ...) 09:47:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.250171 V 09:47:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.250171 (V, A, ohm, ...), Measured Value = 27.363486 (C, atm, Hz, ...) 09:47:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.669663 V 09:47:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669663 (V, A, ohm, ...), Measured Value = 125.224710 (C, atm, Hz, ...) 09:47:38 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092333 V 09:47:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092333 (V, A, ohm, ...), Measured Value = 6.924945 (C, atm, Hz, ...) 09:47:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 99.99 P1 = MAIN (V), Value = 7.07 P2 = Coil, Value = 27.03 P3 = Magnet Core, Value = 26.14 P4 = Ambient Temp (C), Value = 19.18 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 27.36 P7 = Supply Pres(psi), Value = 125.22 P8 = Return Pres(psi), Value = 6.92 09:47:38 Magnetic Field Measurement Measuring the magnet strength... 09:47:38 Integrated Voltage Measurement... 09:47:39 Magnet Current for MAIN, Imag = 99.9885 A Vtrans = 0.999822 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:47:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046924717 Vs 09:47:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046992497 Vs 09:47:56 Magnet Current for MAIN, Imag = 99.9885 A Vtrans = 0.999822 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:48:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046970790 Vs 09:48:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047008435 Vs 09:48:13 Magnet Current for MAIN, Imag = 99.9883 A Vtrans = 0.999820 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:48:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046932057 Vs 09:48:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047001665 Vs 09:48:29 Magnet Current for MAIN, Imag = 99.9884 A Vtrans = 0.999821 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:48:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046948030 Vs 09:48:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046987429 Vs 09:48:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046970703 +- 0.000011483 Vs 09:48:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.046970703 +- 0.000011483 Vs BL = -0.52189670 +- 0.00012759 Tm 09:48:49 Position moved: 0.000000 m 09:48:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.52190 0.00013 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.52190 0.00013 -0.52190 0.00000 09:48:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.52190 0.00013 SL = -0.5218967 +- 0.0001276 Tm^2/m^n 09:48:49 Magnet Strength Measurement Harmonic Number = 1 SL = -0.5218967 +- 0.0001276 Tm^2/m^n Remeasure 09:48:49 Magnetic Field Measurement Measuring the magnet strength... 09:48:49 Integrated Voltage Measurement... 09:48:50 Magnet Current for MAIN, Imag = 99.9884 A Vtrans = 0.999821 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:48:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046969468 Vs 09:49:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046972429 Vs 09:49:08 Magnet Current for MAIN, Imag = 99.9889 A Vtrans = 0.999826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:49:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046954729 Vs 09:49:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046983106 Vs 09:49:24 Magnet Current for MAIN, Imag = 99.9885 A Vtrans = 0.999822 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:49:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046966941 Vs 09:49:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047000428 Vs 09:49:41 Magnet Current for MAIN, Imag = 99.9881 A Vtrans = 0.999818 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:49:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046922922 Vs 09:49:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046946934 Vs 09:49:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046964620 +- 0.000018053 Vs 09:49:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.046964620 +- 0.000018053 Vs BL = -0.52182911 +- 0.00020059 Tm 09:50:00 Position moved: 0.000000 m 09:50:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.52183 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.52183 0.00020 -0.52183 0.00000 09:50:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.52183 0.00020 SL = -0.5218291 +- 0.0002006 Tm^2/m^n 09:50:00 Magnet Strength Measurement Harmonic Number = 1 SL = -0.5218291 +- 0.0002006 Tm^2/m^n Remeasure 09:50:00 Magnetic Field Measurement Measuring the magnet strength... 09:50:01 Integrated Voltage Measurement... 09:50:01 Magnet Current for MAIN, Imag = 99.9882 A Vtrans = 0.999819 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:50:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046920094 Vs 09:50:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046991140 Vs 09:50:19 Magnet Current for MAIN, Imag = 99.9882 A Vtrans = 0.999819 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:50:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046960181 Vs 09:50:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046983598 Vs 09:50:36 Magnet Current for MAIN, Imag = 99.9881 A Vtrans = 0.999818 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:50:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046943190 Vs 09:50:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047004619 Vs 09:50:52 Magnet Current for MAIN, Imag = 99.9881 A Vtrans = 0.999818 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:51:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046957692 Vs 09:51:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046976146 Vs 09:51:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046967083 +- 0.000007091 Vs 09:51:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.046967083 +- 0.000007091 Vs BL = -0.52185647 +- 0.00007879 Tm 09:51:12 Position moved: 0.000000 m 09:51:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.52186 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.52186 0.00008 -0.52186 0.00000 09:51:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.52186 0.00008 SL = -0.5218565 +- 0.0000788 Tm^2/m^n 09:51:12 Magnet Strength Measurement Harmonic Number = 1 SL = -0.5218565 +- 0.0000788 Tm^2/m^n 09:51:15 Position moved: 0.000000 m 09:51:15 Magnet system MAIN current ramping to 110.0000 A... 09:51:31 Magnet Current for MAIN, Imag = 109.9746 A Vtrans = 1.099683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:51:32 MAIN (V) Voltage Measurement, V = 7.784935 V 09:51:33 Temperature Measurement, Probe Number = 0, T = 27.079000 C 09:51:33 Temperature Measurement, Probe Number = 1, T = 26.236000 C 09:51:34 Temperature Measurement, Probe Number = 2, T = 19.324000 C 09:51:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317632 V 09:51:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317632 (V, A, ohm, ...), Measured Value = 28.300444 (C, atm, Hz, ...) 09:51:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.256220 V 09:51:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.256220 (V, A, ohm, ...), Measured Value = 27.447500 (C, atm, Hz, ...) 09:51:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662311 V 09:51:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662311 (V, A, ohm, ...), Measured Value = 124.673317 (C, atm, Hz, ...) 09:51:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092597 V 09:51:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092597 (V, A, ohm, ...), Measured Value = 6.944775 (C, atm, Hz, ...) 09:51:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 109.97 P1 = MAIN (V), Value = 7.78 P2 = Coil, Value = 27.08 P3 = Magnet Core, Value = 26.24 P4 = Ambient Temp (C), Value = 19.32 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 27.45 P7 = Supply Pres(psi), Value = 124.67 P8 = Return Pres(psi), Value = 6.94 09:51:37 Magnetic Field Measurement Measuring the magnet strength... 09:51:37 Integrated Voltage Measurement... 09:51:38 Magnet Current for MAIN, Imag = 109.9748 A Vtrans = 1.099685 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:51:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.051585498 Vs 09:51:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.051653855 Vs 09:51:55 Magnet Current for MAIN, Imag = 109.9747 A Vtrans = 1.099684 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:52:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.051648348 Vs 09:52:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.051624648 Vs 09:52:12 Magnet Current for MAIN, Imag = 109.9749 A Vtrans = 1.099686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:52:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.051620954 Vs 09:52:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.051660526 Vs 09:52:28 Magnet Current for MAIN, Imag = 109.9746 A Vtrans = 1.099683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:52:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.051656009 Vs 09:52:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.051648194 Vs 09:52:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.051637254 +- 0.000011642 Vs 09:52:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.051637254 +- 0.000011642 Vs BL = -0.57374727 +- 0.00012935 Tm 09:52:48 Position moved: 0.000000 m 09:52:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.57375 0.00013 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.57375 0.00013 -0.57375 0.00000 09:52:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.57375 0.00013 SL = -0.5737473 +- 0.0001294 Tm^2/m^n 09:52:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.5737473 +- 0.0001294 Tm^2/m^n Remeasure 09:52:48 Magnetic Field Measurement Measuring the magnet strength... 09:52:48 Integrated Voltage Measurement... 09:52:49 Magnet Current for MAIN, Imag = 109.9745 A Vtrans = 1.099682 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:52:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.051622478 Vs 09:53:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.051662089 Vs 09:53:07 Magnet Current for MAIN, Imag = 109.9748 A Vtrans = 1.099685 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:53:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.051628916 Vs 09:53:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.051675622 Vs 09:53:23 Magnet Current for MAIN, Imag = 109.9747 A Vtrans = 1.099684 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:53:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.051618450 Vs 09:53:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.051658765 Vs 09:53:40 Magnet Current for MAIN, Imag = 109.9748 A Vtrans = 1.099685 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:53:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.051627803 Vs 09:53:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.051645433 Vs 09:53:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.051642445 +- 0.000006025 Vs 09:53:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.051642445 +- 0.000006025 Vs BL = -0.57380494 +- 0.00006695 Tm 09:53:59 Position moved: 0.000000 m 09:53:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.57380 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.57380 0.00007 -0.57380 0.00000 09:53:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.57380 0.00007 SL = -0.5738049 +- 0.0000669 Tm^2/m^n 09:53:59 Magnet Strength Measurement Harmonic Number = 1 SL = -0.5738049 +- 0.0000669 Tm^2/m^n 09:54:02 Position moved: 0.000000 m 09:54:02 Magnet system MAIN current ramping to 120.0000 A... 09:54:19 Magnet Current for MAIN, Imag = 119.9746 A Vtrans = 1.199683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:54:20 MAIN (V) Voltage Measurement, V = 8.498206 V 09:54:20 Temperature Measurement, Probe Number = 0, T = 27.078000 C 09:54:21 Temperature Measurement, Probe Number = 1, T = 26.222000 C 09:54:21 Temperature Measurement, Probe Number = 2, T = 19.474000 C 09:54:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317795 V 09:54:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317795 (V, A, ohm, ...), Measured Value = 28.302704 (C, atm, Hz, ...) 09:54:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.263295 V 09:54:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.263295 (V, A, ohm, ...), Measured Value = 27.545761 (C, atm, Hz, ...) 09:54:23 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663030 V 09:54:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663030 (V, A, ohm, ...), Measured Value = 124.727272 (C, atm, Hz, ...) 09:54:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092648 V 09:54:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092648 (V, A, ohm, ...), Measured Value = 6.948593 (C, atm, Hz, ...) 09:54:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 119.97 P1 = MAIN (V), Value = 8.50 P2 = Coil, Value = 27.08 P3 = Magnet Core, Value = 26.22 P4 = Ambient Temp (C), Value = 19.47 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 27.55 P7 = Supply Pres(psi), Value = 124.73 P8 = Return Pres(psi), Value = 6.95 09:54:24 Magnetic Field Measurement Measuring the magnet strength... 09:54:24 Integrated Voltage Measurement... 09:54:25 Magnet Current for MAIN, Imag = 119.9749 A Vtrans = 1.199685 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:54:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056329416 Vs 09:54:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056338459 Vs 09:54:42 Magnet Current for MAIN, Imag = 119.9749 A Vtrans = 1.199686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:54:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056316726 Vs 09:54:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056306147 Vs 09:54:59 Magnet Current for MAIN, Imag = 119.9745 A Vtrans = 1.199682 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:55:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056332633 Vs 09:55:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056291471 Vs 09:55:15 Magnet Current for MAIN, Imag = 119.9747 A Vtrans = 1.199683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:55:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056350773 Vs 09:55:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056303578 Vs 09:55:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056321150 +- 0.000009708 Vs 09:55:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.056321150 +- 0.000009708 Vs BL = -0.62579056 +- 0.00010786 Tm 09:55:35 Position moved: 0.000000 m 09:55:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.62579 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.62579 0.00011 -0.62579 0.00000 09:55:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.62579 0.00011 SL = -0.6257906 +- 0.0001079 Tm^2/m^n 09:55:35 Magnet Strength Measurement Harmonic Number = 1 SL = -0.6257906 +- 0.0001079 Tm^2/m^n 09:55:38 Position moved: 0.000000 m 09:55:38 Magnet system MAIN current ramping to 130.0000 A... 09:55:54 Magnet Current for MAIN, Imag = 129.9627 A Vtrans = 1.299564 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:55:55 MAIN (V) Voltage Measurement, V = 9.211165 V 09:55:56 Temperature Measurement, Probe Number = 0, T = 27.128000 C 09:55:56 Temperature Measurement, Probe Number = 1, T = 26.227000 C 09:55:57 Temperature Measurement, Probe Number = 2, T = 19.489000 C 09:55:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317542 V 09:55:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317542 (V, A, ohm, ...), Measured Value = 28.299192 (C, atm, Hz, ...) 09:55:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.268130 V 09:55:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.268130 (V, A, ohm, ...), Measured Value = 27.612917 (C, atm, Hz, ...) 09:55:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662770 V 09:55:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662770 (V, A, ohm, ...), Measured Value = 124.707728 (C, atm, Hz, ...) 09:56:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092544 V 09:56:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092544 (V, A, ohm, ...), Measured Value = 6.940770 (C, atm, Hz, ...) 09:56:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 129.96 P1 = MAIN (V), Value = 9.21 P2 = Coil, Value = 27.13 P3 = Magnet Core, Value = 26.23 P4 = Ambient Temp (C), Value = 19.49 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 27.61 P7 = Supply Pres(psi), Value = 124.71 P8 = Return Pres(psi), Value = 6.94 09:56:00 Magnetic Field Measurement Measuring the magnet strength... 09:56:00 Integrated Voltage Measurement... 09:56:00 Magnet Current for MAIN, Imag = 129.9623 A Vtrans = 1.299560 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:56:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.060990633 Vs 09:56:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061010232 Vs 09:56:18 Magnet Current for MAIN, Imag = 129.9627 A Vtrans = 1.299564 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:56:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.060983077 Vs 09:56:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.060999958 Vs 09:56:35 Magnet Current for MAIN, Imag = 129.9625 A Vtrans = 1.299562 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:56:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061016737 Vs 09:56:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.060977215 Vs 09:56:51 Magnet Current for MAIN, Imag = 129.9623 A Vtrans = 1.299560 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:56:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.060992476 Vs 09:57:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061032819 Vs 09:57:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061000393 +- 0.000007756 Vs 09:57:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.061000393 +- 0.000007756 Vs BL = -0.67778215 +- 0.00008618 Tm 09:57:11 Position moved: 0.000000 m 09:57:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.67778 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.67778 0.00009 -0.67778 0.00000 09:57:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.67778 0.00009 SL = -0.6777821 +- 0.0000862 Tm^2/m^n 09:57:11 Magnet Strength Measurement Harmonic Number = 1 SL = -0.6777821 +- 0.0000862 Tm^2/m^n 09:57:14 Position moved: 0.000000 m 09:57:14 Magnet system MAIN current ramping to 140.0000 A... 09:57:31 Magnet Current for MAIN, Imag = 139.9537 A Vtrans = 1.399474 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:57:31 MAIN (V) Voltage Measurement, V = 9.926443 V 09:57:32 Temperature Measurement, Probe Number = 0, T = 27.217000 C 09:57:32 Temperature Measurement, Probe Number = 1, T = 26.180000 C 09:57:33 Temperature Measurement, Probe Number = 2, T = 19.543000 C 09:57:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317157 V 09:57:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317157 (V, A, ohm, ...), Measured Value = 28.293842 (C, atm, Hz, ...) 09:57:34 Sensor Voltage Measurement, Sensor Number = 1, V = 2.273457 V 09:57:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.273457 (V, A, ohm, ...), Measured Value = 27.686903 (C, atm, Hz, ...) 09:57:35 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662929 V 09:57:35 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662929 (V, A, ohm, ...), Measured Value = 124.719645 (C, atm, Hz, ...) 09:57:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092580 V 09:57:36 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092580 (V, A, ohm, ...), Measured Value = 6.943537 (C, atm, Hz, ...) 09:57:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 139.95 P1 = MAIN (V), Value = 9.93 P2 = Coil, Value = 27.22 P3 = Magnet Core, Value = 26.18 P4 = Ambient Temp (C), Value = 19.54 P5 = Supply Temp(C), Value = 28.29 P6 = Return Temp(C), Value = 27.69 P7 = Supply Pres(psi), Value = 124.72 P8 = Return Pres(psi), Value = 6.94 09:57:36 Magnetic Field Measurement Measuring the magnet strength... 09:57:36 Integrated Voltage Measurement... 09:57:37 Magnet Current for MAIN, Imag = 139.9542 A Vtrans = 1.399479 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:57:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.065706762 Vs 09:57:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.065641424 Vs 09:57:54 Magnet Current for MAIN, Imag = 139.9540 A Vtrans = 1.399477 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:58:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.065664340 Vs 09:58:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.065663991 Vs 09:58:11 Magnet Current for MAIN, Imag = 139.9540 A Vtrans = 1.399477 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:58:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.065676082 Vs 09:58:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.065658844 Vs 09:58:27 Magnet Current for MAIN, Imag = 139.9533 A Vtrans = 1.399470 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:58:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.065648411 Vs 09:58:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.065643140 Vs 09:58:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.065662874 +- 0.000010500 Vs 09:58:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.065662874 +- 0.000010500 Vs BL = -0.72958749 +- 0.00011666 Tm 09:58:47 Position moved: 0.000000 m 09:58:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.72959 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.72959 0.00012 -0.72959 0.00000 09:58:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.72959 0.00012 SL = -0.7295875 +- 0.0001167 Tm^2/m^n 09:58:47 Magnet Strength Measurement Harmonic Number = 1 SL = -0.7295875 +- 0.0001167 Tm^2/m^n 09:58:50 Position moved: 0.000000 m 09:58:50 Magnet system MAIN current ramping to 150.0000 A... 09:59:07 Magnet Current for MAIN, Imag = 149.9388 A Vtrans = 1.499325 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:59:07 MAIN (V) Voltage Measurement, V = 10.643190 V 09:59:08 Temperature Measurement, Probe Number = 0, T = 27.300000 C 09:59:08 Temperature Measurement, Probe Number = 1, T = 26.214000 C 09:59:09 Temperature Measurement, Probe Number = 2, T = 19.691000 C 09:59:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317224 V 09:59:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317224 (V, A, ohm, ...), Measured Value = 28.294778 (C, atm, Hz, ...) 09:59:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.280117 V 09:59:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.280117 (V, A, ohm, ...), Measured Value = 27.779408 (C, atm, Hz, ...) 09:59:11 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659132 V 09:59:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659132 (V, A, ohm, ...), Measured Value = 124.434893 (C, atm, Hz, ...) 09:59:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092652 V 09:59:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092652 (V, A, ohm, ...), Measured Value = 6.948878 (C, atm, Hz, ...) 09:59:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.94 P1 = MAIN (V), Value = 10.64 P2 = Coil, Value = 27.30 P3 = Magnet Core, Value = 26.21 P4 = Ambient Temp (C), Value = 19.69 P5 = Supply Temp(C), Value = 28.29 P6 = Return Temp(C), Value = 27.78 P7 = Supply Pres(psi), Value = 124.43 P8 = Return Pres(psi), Value = 6.95 09:59:12 Magnetic Field Measurement Measuring the magnet strength... 09:59:12 Integrated Voltage Measurement... 09:59:13 Magnet Current for MAIN, Imag = 149.9385 A Vtrans = 1.499322 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:59:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070368597 Vs 09:59:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070298310 Vs 09:59:30 Magnet Current for MAIN, Imag = 149.9383 A Vtrans = 1.499319 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:59:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070302667 Vs 09:59:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070335408 Vs 09:59:47 Magnet Current for MAIN, Imag = 149.9389 A Vtrans = 1.499326 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 09:59:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070349401 Vs 10:00:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070394565 Vs 10:00:03 Magnet Current for MAIN, Imag = 149.9385 A Vtrans = 1.499322 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:00:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070343674 Vs 10:00:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070381086 Vs 10:00:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070346714 +- 0.000021365 Vs 10:00:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.070346714 +- 0.000021365 Vs BL = -0.78163015 +- 0.00023738 Tm 10:00:23 Position moved: 0.000000 m 10:00:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.78163 0.00024 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.78163 0.00024 -0.78163 0.00000 10:00:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.78163 0.00024 SL = -0.7816302 +- 0.0002374 Tm^2/m^n 10:00:23 Magnet Strength Measurement Harmonic Number = 1 SL = -0.7816302 +- 0.0002374 Tm^2/m^n Remeasure 10:00:23 Magnetic Field Measurement Measuring the magnet strength... 10:00:23 Integrated Voltage Measurement... 10:00:24 Magnet Current for MAIN, Imag = 149.9384 A Vtrans = 1.499321 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:00:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070365707 Vs 10:00:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070359229 Vs 10:00:41 Magnet Current for MAIN, Imag = 149.9383 A Vtrans = 1.499319 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:00:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070351493 Vs 10:00:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070304821 Vs 10:00:58 Magnet Current for MAIN, Imag = 149.9383 A Vtrans = 1.499319 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:01:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070315637 Vs 10:01:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070349789 Vs 10:01:14 Magnet Current for MAIN, Imag = 149.9376 A Vtrans = 1.499313 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:01:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070327487 Vs 10:01:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070300539 Vs 10:01:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070334338 +- 0.000017644 Vs 10:01:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.070334338 +- 0.000017644 Vs BL = -0.78149264 +- 0.00019605 Tm 10:01:34 Position moved: 0.000000 m 10:01:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.78149 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.78149 0.00020 -0.78149 0.00000 10:01:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.78149 0.00020 SL = -0.7814926 +- 0.0001960 Tm^2/m^n 10:01:34 Magnet Strength Measurement Harmonic Number = 1 SL = -0.7814926 +- 0.0001960 Tm^2/m^n Remeasure 10:01:34 Magnetic Field Measurement Measuring the magnet strength... 10:01:34 Integrated Voltage Measurement... 10:01:35 Magnet Current for MAIN, Imag = 149.9379 A Vtrans = 1.499316 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:01:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070406535 Vs 10:01:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070306303 Vs 10:01:52 Magnet Current for MAIN, Imag = 149.9378 A Vtrans = 1.499315 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:02:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070293917 Vs 10:02:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070316258 Vs 10:02:09 Magnet Current for MAIN, Imag = 149.9376 A Vtrans = 1.499313 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:02:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070313891 Vs 10:02:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070331723 Vs 10:02:25 Magnet Current for MAIN, Imag = 149.9376 A Vtrans = 1.499313 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:02:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070375092 Vs 10:02:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.070361989 Vs 10:02:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.070338214 +- 0.000025426 Vs 10:02:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.070338214 +- 0.000025426 Vs BL = -0.78153571 +- 0.00028251 Tm 10:02:45 Position moved: 0.000000 m 10:02:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.78154 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.78154 0.00028 -0.78154 0.00000 10:02:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.78154 0.00028 SL = -0.7815357 +- 0.0002825 Tm^2/m^n 10:02:45 Magnet Strength Measurement Harmonic Number = 1 SL = -0.7815357 +- 0.0002825 Tm^2/m^n 10:02:48 Position moved: 0.000000 m 10:02:48 Magnet system MAIN current ramping to 160.0000 A... 10:03:04 Magnet Current for MAIN, Imag = 159.9582 A Vtrans = 1.599519 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:03:05 MAIN (V) Voltage Measurement, V = 11.366937 V 10:03:05 Temperature Measurement, Probe Number = 0, T = 27.471000 C 10:03:06 Temperature Measurement, Probe Number = 1, T = 26.218000 C 10:03:07 Temperature Measurement, Probe Number = 2, T = 19.751000 C 10:03:07 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318259 V 10:03:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318259 (V, A, ohm, ...), Measured Value = 28.309147 (C, atm, Hz, ...) 10:03:08 Sensor Voltage Measurement, Sensor Number = 1, V = 2.300647 V 10:03:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.300647 (V, A, ohm, ...), Measured Value = 28.064536 (C, atm, Hz, ...) 10:03:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664242 V 10:03:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664242 (V, A, ohm, ...), Measured Value = 124.818120 (C, atm, Hz, ...) 10:03:09 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092767 V 10:03:09 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092767 (V, A, ohm, ...), Measured Value = 6.957547 (C, atm, Hz, ...) 10:03:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 159.96 P1 = MAIN (V), Value = 11.37 P2 = Coil, Value = 27.47 P3 = Magnet Core, Value = 26.22 P4 = Ambient Temp (C), Value = 19.75 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 28.06 P7 = Supply Pres(psi), Value = 124.82 P8 = Return Pres(psi), Value = 6.96 10:03:09 Magnetic Field Measurement Measuring the magnet strength... 10:03:09 Integrated Voltage Measurement... 10:03:10 Magnet Current for MAIN, Imag = 159.9580 A Vtrans = 1.599517 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:03:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075047293 Vs 10:03:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075010114 Vs 10:03:28 Magnet Current for MAIN, Imag = 159.9580 A Vtrans = 1.599517 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:03:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075003989 Vs 10:03:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075017263 Vs 10:03:44 Magnet Current for MAIN, Imag = 159.9584 A Vtrans = 1.599521 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:03:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075046641 Vs 10:04:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075003573 Vs 10:04:01 Magnet Current for MAIN, Imag = 159.9583 A Vtrans = 1.599520 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:04:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.074990996 Vs 10:04:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075024264 Vs 10:04:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075018017 +- 0.000009041 Vs 10:04:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.075018017 +- 0.000009041 Vs BL = -0.83353352 +- 0.00010046 Tm 10:04:21 Position moved: 0.000000 m 10:04:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.83353 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.83353 0.00010 -0.83353 0.00000 10:04:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.83353 0.00010 SL = -0.8335335 +- 0.0001005 Tm^2/m^n 10:04:21 Magnet Strength Measurement Harmonic Number = 1 SL = -0.8335335 +- 0.0001005 Tm^2/m^n 10:04:23 Position moved: 0.000000 m 10:04:23 Magnet system MAIN current ramping to 170.0000 A... 10:04:40 Magnet Current for MAIN, Imag = 169.9450 A Vtrans = 1.699387 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:04:41 MAIN (V) Voltage Measurement, V = 12.087259 V 10:04:41 Temperature Measurement, Probe Number = 0, T = 27.580000 C 10:04:42 Temperature Measurement, Probe Number = 1, T = 26.277000 C 10:04:43 Temperature Measurement, Probe Number = 2, T = 19.696000 C 10:04:43 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319054 V 10:04:43 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319054 (V, A, ohm, ...), Measured Value = 28.320199 (C, atm, Hz, ...) 10:04:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.310584 V 10:04:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310584 (V, A, ohm, ...), Measured Value = 28.202554 (C, atm, Hz, ...) 10:04:45 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662668 V 10:04:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662668 (V, A, ohm, ...), Measured Value = 124.700107 (C, atm, Hz, ...) 10:04:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093000 V 10:04:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093000 (V, A, ohm, ...), Measured Value = 6.975000 (C, atm, Hz, ...) 10:04:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 169.94 P1 = MAIN (V), Value = 12.09 P2 = Coil, Value = 27.58 P3 = Magnet Core, Value = 26.28 P4 = Ambient Temp (C), Value = 19.70 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 28.20 P7 = Supply Pres(psi), Value = 124.70 P8 = Return Pres(psi), Value = 6.97 10:04:45 Magnetic Field Measurement Measuring the magnet strength... 10:04:45 Integrated Voltage Measurement... 10:04:46 Magnet Current for MAIN, Imag = 169.9451 A Vtrans = 1.699388 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:04:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.079716776 Vs 10:05:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.079682862 Vs 10:05:04 Magnet Current for MAIN, Imag = 169.9451 A Vtrans = 1.699388 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:05:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.079695252 Vs 10:05:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.079645927 Vs 10:05:20 Magnet Current for MAIN, Imag = 169.9453 A Vtrans = 1.699390 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:05:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.079688183 Vs 10:05:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.079650622 Vs 10:05:37 Magnet Current for MAIN, Imag = 169.9453 A Vtrans = 1.699390 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:05:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.079651007 Vs 10:05:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.079726956 Vs 10:05:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.079682198 +- 0.000012796 Vs 10:05:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.079682198 +- 0.000012796 Vs BL = -0.88535776 +- 0.00014218 Tm 10:05:57 Position moved: 0.000000 m 10:05:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.88536 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.88536 0.00014 -0.88536 0.00000 10:05:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.88536 0.00014 SL = -0.8853578 +- 0.0001422 Tm^2/m^n 10:05:57 Magnet Strength Measurement Harmonic Number = 1 SL = -0.8853578 +- 0.0001422 Tm^2/m^n 10:06:00 Position moved: 0.000000 m 10:06:00 Magnet system MAIN current ramping to 180.0000 A... 10:06:16 Magnet Current for MAIN, Imag = 180.0053 A Vtrans = 1.799990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:06:17 MAIN (V) Voltage Measurement, V = 12.816055 V 10:06:17 Temperature Measurement, Probe Number = 0, T = 27.604000 C 10:06:18 Temperature Measurement, Probe Number = 1, T = 26.304000 C 10:06:19 Temperature Measurement, Probe Number = 2, T = 19.778000 C 10:06:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319456 V 10:06:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319456 (V, A, ohm, ...), Measured Value = 28.325778 (C, atm, Hz, ...) 10:06:20 Sensor Voltage Measurement, Sensor Number = 1, V = 2.321692 V 10:06:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321692 (V, A, ohm, ...), Measured Value = 28.356831 (C, atm, Hz, ...) 10:06:21 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667918 V 10:06:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667918 (V, A, ohm, ...), Measured Value = 125.093820 (C, atm, Hz, ...) 10:06:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093074 V 10:06:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093074 (V, A, ohm, ...), Measured Value = 6.980527 (C, atm, Hz, ...) 10:06:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.01 P1 = MAIN (V), Value = 12.82 P2 = Coil, Value = 27.60 P3 = Magnet Core, Value = 26.30 P4 = Ambient Temp (C), Value = 19.78 P5 = Supply Temp(C), Value = 28.33 P6 = Return Temp(C), Value = 28.36 P7 = Supply Pres(psi), Value = 125.09 P8 = Return Pres(psi), Value = 6.98 10:06:21 Magnetic Field Measurement Measuring the magnet strength... 10:06:21 Integrated Voltage Measurement... 10:06:22 Magnet Current for MAIN, Imag = 180.0058 A Vtrans = 1.799995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:06:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.084407875 Vs 10:06:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.084333311 Vs 10:06:39 Magnet Current for MAIN, Imag = 180.0058 A Vtrans = 1.799995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:06:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.084378582 Vs 10:06:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.084413386 Vs 10:06:56 Magnet Current for MAIN, Imag = 180.0057 A Vtrans = 1.799994 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:07:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.084389274 Vs 10:07:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.084386295 Vs 10:07:12 Magnet Current for MAIN, Imag = 180.0061 A Vtrans = 1.799998 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:07:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.084396737 Vs 10:07:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.084355538 Vs 10:07:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.084382625 +- 0.000009899 Vs 10:07:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.084382625 +- 0.000009899 Vs BL = -0.93758472 +- 0.00010998 Tm 10:07:32 Position moved: 0.000000 m 10:07:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.93758 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.93758 0.00011 -0.93758 0.00000 10:07:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.93758 0.00011 SL = -0.9375847 +- 0.0001100 Tm^2/m^n 10:07:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.9375847 +- 0.0001100 Tm^2/m^n 10:07:35 Position moved: 0.000000 m 10:07:35 Magnet system MAIN current ramping to 190.0000 A... 10:07:51 Magnet Current for MAIN, Imag = 189.9995 A Vtrans = 1.899932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:07:52 MAIN (V) Voltage Measurement, V = 13.541875 V 10:07:53 Temperature Measurement, Probe Number = 0, T = 27.711000 C 10:07:53 Temperature Measurement, Probe Number = 1, T = 26.338000 C 10:07:54 Temperature Measurement, Probe Number = 2, T = 19.800000 C 10:07:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318968 V 10:07:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318968 (V, A, ohm, ...), Measured Value = 28.318999 (C, atm, Hz, ...) 10:07:55 Sensor Voltage Measurement, Sensor Number = 1, V = 2.333940 V 10:07:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333940 (V, A, ohm, ...), Measured Value = 28.526943 (C, atm, Hz, ...) 10:07:56 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657335 V 10:07:56 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657335 (V, A, ohm, ...), Measured Value = 124.300095 (C, atm, Hz, ...) 10:07:56 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093017 V 10:07:57 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093017 (V, A, ohm, ...), Measured Value = 6.976238 (C, atm, Hz, ...) 10:07:57 Magnet Test Parameter Measurements P0 = MAIN, Value = 190.00 P1 = MAIN (V), Value = 13.54 P2 = Coil, Value = 27.71 P3 = Magnet Core, Value = 26.34 P4 = Ambient Temp (C), Value = 19.80 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 28.53 P7 = Supply Pres(psi), Value = 124.30 P8 = Return Pres(psi), Value = 6.98 10:07:57 Magnetic Field Measurement Measuring the magnet strength... 10:07:57 Integrated Voltage Measurement... 10:07:57 Magnet Current for MAIN, Imag = 189.9995 A Vtrans = 1.899932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:08:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.089004233 Vs 10:08:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.089003898 Vs 10:08:15 Magnet Current for MAIN, Imag = 189.9998 A Vtrans = 1.899935 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:08:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.088989933 Vs 10:08:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.089075415 Vs 10:08:31 Magnet Current for MAIN, Imag = 189.9994 A Vtrans = 1.899931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:08:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.088991600 Vs 10:08:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.089111026 Vs 10:08:48 Magnet Current for MAIN, Imag = 189.9995 A Vtrans = 1.899932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:08:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.089012489 Vs 10:09:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.089017919 Vs 10:09:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.089025814 +- 0.000017908 Vs 10:09:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.089025814 +- 0.000017908 Vs BL = -0.98917571 +- 0.00019898 Tm 10:09:08 Position moved: 0.000000 m 10:09:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.98918 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.98918 0.00020 -0.98918 0.00000 10:09:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.98918 0.00020 SL = -0.9891757 +- 0.0001990 Tm^2/m^n 10:09:08 Magnet Strength Measurement Harmonic Number = 1 SL = -0.9891757 +- 0.0001990 Tm^2/m^n Remeasure 10:09:08 Magnetic Field Measurement Measuring the magnet strength... 10:09:08 Integrated Voltage Measurement... 10:09:09 Magnet Current for MAIN, Imag = 189.9995 A Vtrans = 1.899932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:09:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.089037372 Vs 10:09:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.089005018 Vs 10:09:26 Magnet Current for MAIN, Imag = 189.9993 A Vtrans = 1.899930 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:09:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.089033992 Vs 10:09:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.089061285 Vs 10:09:43 Magnet Current for MAIN, Imag = 189.9995 A Vtrans = 1.899932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:09:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.089058278 Vs 10:09:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.089049413 Vs 10:09:59 Magnet Current for MAIN, Imag = 189.9999 A Vtrans = 1.899936 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:10:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.089064741 Vs 10:10:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.089037949 Vs 10:10:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.089043506 +- 0.000013069 Vs 10:10:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.089043506 +- 0.000013069 Vs BL = -0.98937229 +- 0.00014521 Tm 10:10:19 Position moved: 0.000000 m 10:10:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.98937 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.98937 0.00015 -0.98937 0.00000 10:10:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.98937 0.00015 SL = -0.9893723 +- 0.0001452 Tm^2/m^n 10:10:19 Magnet Strength Measurement Harmonic Number = 1 SL = -0.9893723 +- 0.0001452 Tm^2/m^n 10:10:22 Position moved: 0.000000 m 10:10:22 Magnet system MAIN current ramping to 200.0000 A... 10:10:38 Magnet Current for MAIN, Imag = 199.9981 A Vtrans = 1.999918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:10:39 MAIN (V) Voltage Measurement, V = 14.273364 V 10:10:40 Temperature Measurement, Probe Number = 0, T = 27.848000 C 10:10:40 Temperature Measurement, Probe Number = 1, T = 26.425000 C 10:10:41 Temperature Measurement, Probe Number = 2, T = 19.917000 C 10:10:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318861 V 10:10:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318861 (V, A, ohm, ...), Measured Value = 28.317515 (C, atm, Hz, ...) 10:10:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.359500 V 10:10:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359500 (V, A, ohm, ...), Measured Value = 28.881943 (C, atm, Hz, ...) 10:10:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662194 V 10:10:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662194 (V, A, ohm, ...), Measured Value = 124.664543 (C, atm, Hz, ...) 10:10:44 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093119 V 10:10:44 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093119 (V, A, ohm, ...), Measured Value = 6.983955 (C, atm, Hz, ...) 10:10:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.00 P1 = MAIN (V), Value = 14.27 P2 = Coil, Value = 27.85 P3 = Magnet Core, Value = 26.43 P4 = Ambient Temp (C), Value = 19.92 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 28.88 P7 = Supply Pres(psi), Value = 124.66 P8 = Return Pres(psi), Value = 6.98 10:10:44 Magnetic Field Measurement Measuring the magnet strength... 10:10:44 Integrated Voltage Measurement... 10:10:44 Magnet Current for MAIN, Imag = 199.9991 A Vtrans = 1.999928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:10:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.093732283 Vs 10:11:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.093656934 Vs 10:11:02 Magnet Current for MAIN, Imag = 199.9991 A Vtrans = 1.999928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:11:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.093750703 Vs 10:11:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.093721211 Vs 10:11:18 Magnet Current for MAIN, Imag = 199.9991 A Vtrans = 1.999928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:11:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.093671690 Vs 10:11:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.093677781 Vs 10:11:35 Magnet Current for MAIN, Imag = 199.9992 A Vtrans = 1.999929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:11:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.093668189 Vs 10:11:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.093733668 Vs 10:11:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.093701557 +- 0.000022088 Vs 10:11:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.093701557 +- 0.000022088 Vs BL = -1.04112842 +- 0.00024542 Tm 10:11:54 Position moved: 0.000000 m 10:11:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -1.04113 0.00025 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -1.04113 0.00025 -1.04113 0.00000 10:11:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -1.04113 0.00025 SL = -1.0411284 +- 0.0002454 Tm^2/m^n 10:11:54 Magnet Strength Measurement Harmonic Number = 1 SL = -1.0411284 +- 0.0002454 Tm^2/m^n Remeasure 10:11:54 Magnetic Field Measurement Measuring the magnet strength... 10:11:54 Integrated Voltage Measurement... 10:11:55 Magnet Current for MAIN, Imag = 199.9987 A Vtrans = 1.999924 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:12:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.093767271 Vs 10:12:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.093748741 Vs 10:12:13 Magnet Current for MAIN, Imag = 199.9991 A Vtrans = 1.999928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:12:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.093694741 Vs 10:12:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.093758257 Vs 10:12:29 Magnet Current for MAIN, Imag = 199.9991 A Vtrans = 1.999928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:12:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.093724150 Vs 10:12:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.093708144 Vs 10:12:46 Magnet Current for MAIN, Imag = 199.9988 A Vtrans = 1.999925 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:12:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.093760756 Vs 10:13:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.093764375 Vs 10:13:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.093740805 +- 0.000019888 Vs 10:13:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.093740805 +- 0.000019888 Vs BL = -1.04156449 +- 0.00022097 Tm 10:13:05 Position moved: 0.000000 m 10:13:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -1.04156 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -1.04156 0.00022 -1.04156 0.00000 10:13:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -1.04156 0.00022 SL = -1.0415645 +- 0.0002210 Tm^2/m^n 10:13:06 Magnet Strength Measurement Harmonic Number = 1 SL = -1.0415645 +- 0.0002210 Tm^2/m^n 10:13:08 Position moved: 0.000000 m 10:13:08 Magnet system MAIN current ramping to 180.0000 A... 10:13:31 Magnet Current for MAIN, Imag = 180.0071 A Vtrans = 1.800008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:13:31 MAIN (V) Voltage Measurement, V = 12.852677 V 10:13:32 Temperature Measurement, Probe Number = 0, T = 27.990000 C 10:13:32 Temperature Measurement, Probe Number = 1, T = 26.466000 C 10:13:33 Temperature Measurement, Probe Number = 2, T = 19.878000 C 10:13:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319231 V 10:13:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319231 (V, A, ohm, ...), Measured Value = 28.322653 (C, atm, Hz, ...) 10:13:34 Sensor Voltage Measurement, Sensor Number = 1, V = 2.389840 V 10:13:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.389840 (V, A, ohm, ...), Measured Value = 29.303339 (C, atm, Hz, ...) 10:13:35 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664468 V 10:13:35 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664468 (V, A, ohm, ...), Measured Value = 124.835093 (C, atm, Hz, ...) 10:13:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093283 V 10:13:36 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093283 (V, A, ohm, ...), Measured Value = 6.996255 (C, atm, Hz, ...) 10:13:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.01 P1 = MAIN (V), Value = 12.85 P2 = Coil, Value = 27.99 P3 = Magnet Core, Value = 26.47 P4 = Ambient Temp (C), Value = 19.88 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 29.30 P7 = Supply Pres(psi), Value = 124.84 P8 = Return Pres(psi), Value = 7.00 10:13:36 Magnetic Field Measurement Measuring the magnet strength... 10:13:36 Integrated Voltage Measurement... 10:13:37 Magnet Current for MAIN, Imag = 180.0081 A Vtrans = 1.800018 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:13:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.084683671 Vs 10:13:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.084627529 Vs 10:13:54 Magnet Current for MAIN, Imag = 180.0082 A Vtrans = 1.800019 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:14:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.084661853 Vs 10:14:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.084604065 Vs 10:14:11 Magnet Current for MAIN, Imag = 180.0082 A Vtrans = 1.800019 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:14:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.084647821 Vs 10:14:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.084615458 Vs 10:14:27 Magnet Current for MAIN, Imag = 180.0085 A Vtrans = 1.800022 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:14:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.084686136 Vs 10:14:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.084622267 Vs 10:14:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.084643600 +- 0.000011321 Vs 10:14:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.084643600 +- 0.000011321 Vs BL = -0.94048444 +- 0.00012579 Tm 10:14:47 Position moved: 0.000000 m 10:14:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.94048 0.00013 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.94048 0.00013 -0.94048 0.00000 10:14:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.94048 0.00013 SL = -0.9404844 +- 0.0001258 Tm^2/m^n 10:14:47 Magnet Strength Measurement Harmonic Number = 1 SL = -0.9404844 +- 0.0001258 Tm^2/m^n 10:14:50 Position moved: 0.000000 m 10:14:50 Magnet system MAIN current ramping to 160.0000 A... 10:15:12 Magnet Current for MAIN, Imag = 159.9594 A Vtrans = 1.599531 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:15:13 MAIN (V) Voltage Measurement, V = 11.400357 V 10:15:14 Temperature Measurement, Probe Number = 0, T = 27.915000 C 10:15:14 Temperature Measurement, Probe Number = 1, T = 26.497000 C 10:15:15 Temperature Measurement, Probe Number = 2, T = 20.012000 C 10:15:15 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319272 V 10:15:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319272 (V, A, ohm, ...), Measured Value = 28.323218 (C, atm, Hz, ...) 10:15:16 Sensor Voltage Measurement, Sensor Number = 1, V = 2.406485 V 10:15:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.406485 (V, A, ohm, ...), Measured Value = 29.534515 (C, atm, Hz, ...) 10:15:17 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660575 V 10:15:17 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660575 (V, A, ohm, ...), Measured Value = 124.543095 (C, atm, Hz, ...) 10:15:17 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093318 V 10:15:17 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093318 (V, A, ohm, ...), Measured Value = 6.998828 (C, atm, Hz, ...) 10:15:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 159.96 P1 = MAIN (V), Value = 11.40 P2 = Coil, Value = 27.91 P3 = Magnet Core, Value = 26.50 P4 = Ambient Temp (C), Value = 20.01 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 29.53 P7 = Supply Pres(psi), Value = 124.54 P8 = Return Pres(psi), Value = 7.00 10:15:18 Magnetic Field Measurement Measuring the magnet strength... 10:15:18 Integrated Voltage Measurement... 10:15:18 Magnet Current for MAIN, Imag = 159.9594 A Vtrans = 1.599531 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:15:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075423722 Vs 10:15:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075418506 Vs 10:15:36 Magnet Current for MAIN, Imag = 159.9592 A Vtrans = 1.599529 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:15:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075435931 Vs 10:15:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075440709 Vs 10:15:52 Magnet Current for MAIN, Imag = 159.9589 A Vtrans = 1.599526 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:16:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075447533 Vs 10:16:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075375071 Vs 10:16:09 Magnet Current for MAIN, Imag = 159.9593 A Vtrans = 1.599530 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:16:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075441758 Vs 10:16:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075454044 Vs 10:16:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075429659 +- 0.000014298 Vs 10:16:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.075429659 +- 0.000014298 Vs BL = -0.83810733 +- 0.00015887 Tm 10:16:28 Position moved: 0.000000 m 10:16:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.83811 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.83811 0.00016 -0.83811 0.00000 10:16:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.83811 0.00016 SL = -0.8381073 +- 0.0001589 Tm^2/m^n 10:16:28 Magnet Strength Measurement Harmonic Number = 1 SL = -0.8381073 +- 0.0001589 Tm^2/m^n Remeasure 10:16:29 Magnetic Field Measurement Measuring the magnet strength... 10:16:29 Integrated Voltage Measurement... 10:16:29 Magnet Current for MAIN, Imag = 159.9589 A Vtrans = 1.599526 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:16:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075448676 Vs 10:16:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075430268 Vs 10:16:47 Magnet Current for MAIN, Imag = 159.9591 A Vtrans = 1.599527 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:16:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075409318 Vs 10:17:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075396025 Vs 10:17:03 Magnet Current for MAIN, Imag = 159.9588 A Vtrans = 1.599525 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:17:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075460819 Vs 10:17:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075428193 Vs 10:17:20 Magnet Current for MAIN, Imag = 159.9591 A Vtrans = 1.599527 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:17:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075418843 Vs 10:17:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075411353 Vs 10:17:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075425437 +- 0.000017218 Vs 10:17:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.075425437 +- 0.000017218 Vs BL = -0.83806041 +- 0.00019131 Tm 10:17:40 Position moved: 0.000000 m 10:17:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.83806 0.00019 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.83806 0.00019 -0.83806 0.00000 10:17:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.83806 0.00019 SL = -0.8380604 +- 0.0001913 Tm^2/m^n 10:17:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.8380604 +- 0.0001913 Tm^2/m^n 10:17:43 Position moved: 0.000000 m 10:17:43 Magnet system MAIN current ramping to 140.0000 A... 10:18:05 Magnet Current for MAIN, Imag = 139.9542 A Vtrans = 1.399479 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:18:05 MAIN (V) Voltage Measurement, V = 9.952898 V 10:18:06 Temperature Measurement, Probe Number = 0, T = 27.751000 C 10:18:07 Temperature Measurement, Probe Number = 1, T = 26.542000 C 10:18:07 Temperature Measurement, Probe Number = 2, T = 20.099000 C 10:18:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320600 V 10:18:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320600 (V, A, ohm, ...), Measured Value = 28.341667 (C, atm, Hz, ...) 10:18:09 Sensor Voltage Measurement, Sensor Number = 1, V = 2.419388 V 10:18:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.419388 (V, A, ohm, ...), Measured Value = 29.713722 (C, atm, Hz, ...) 10:18:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.677112 V 10:18:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.677112 (V, A, ohm, ...), Measured Value = 125.783437 (C, atm, Hz, ...) 10:18:10 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093613 V 10:18:10 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093613 (V, A, ohm, ...), Measured Value = 7.020945 (C, atm, Hz, ...) 10:18:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 139.95 P1 = MAIN (V), Value = 9.95 P2 = Coil, Value = 27.75 P3 = Magnet Core, Value = 26.54 P4 = Ambient Temp (C), Value = 20.10 P5 = Supply Temp(C), Value = 28.34 P6 = Return Temp(C), Value = 29.71 P7 = Supply Pres(psi), Value = 125.78 P8 = Return Pres(psi), Value = 7.02 10:18:10 Magnetic Field Measurement Measuring the magnet strength... 10:18:10 Integrated Voltage Measurement... 10:18:11 Magnet Current for MAIN, Imag = 139.9545 A Vtrans = 1.399482 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:18:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.066161558 Vs 10:18:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.066166350 Vs 10:18:28 Magnet Current for MAIN, Imag = 139.9541 A Vtrans = 1.399478 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:18:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.066117518 Vs 10:18:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.066162897 Vs 10:18:45 Magnet Current for MAIN, Imag = 139.9546 A Vtrans = 1.399483 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:18:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.066140527 Vs 10:19:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.066182156 Vs 10:19:02 Magnet Current for MAIN, Imag = 139.9538 A Vtrans = 1.399475 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:19:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.066127919 Vs 10:19:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.066142176 Vs 10:19:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.066150138 +- 0.000012676 Vs 10:19:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.066150138 +- 0.000012676 Vs BL = -0.73500153 +- 0.00014084 Tm 10:19:21 Position moved: 0.000000 m 10:19:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.73500 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.73500 0.00014 -0.73500 0.00000 10:19:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.73500 0.00014 SL = -0.7350015 +- 0.0001408 Tm^2/m^n 10:19:21 Magnet Strength Measurement Harmonic Number = 1 SL = -0.7350015 +- 0.0001408 Tm^2/m^n Remeasure 10:19:21 Magnetic Field Measurement Measuring the magnet strength... 10:19:21 Integrated Voltage Measurement... 10:19:22 Magnet Current for MAIN, Imag = 139.9541 A Vtrans = 1.399478 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:19:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.066162981 Vs 10:19:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.066161233 Vs 10:19:40 Magnet Current for MAIN, Imag = 139.9542 A Vtrans = 1.399479 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:19:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.066143998 Vs 10:19:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.066143665 Vs 10:19:56 Magnet Current for MAIN, Imag = 139.9540 A Vtrans = 1.399477 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:20:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.066110322 Vs 10:20:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.066180975 Vs 10:20:12 Magnet Current for MAIN, Imag = 139.9540 A Vtrans = 1.399477 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:20:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.066146048 Vs 10:20:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.066166717 Vs 10:20:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.066151992 +- 0.000007557 Vs 10:20:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.066151992 +- 0.000007557 Vs BL = -0.73502214 +- 0.00008396 Tm 10:20:32 Position moved: 0.000000 m 10:20:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.73502 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.73502 0.00008 -0.73502 0.00000 10:20:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.73502 0.00008 SL = -0.7350221 +- 0.0000840 Tm^2/m^n 10:20:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.7350221 +- 0.0000840 Tm^2/m^n 10:20:35 Position moved: 0.000000 m 10:20:35 Magnet system MAIN current ramping to 120.0000 A... 10:20:57 Magnet Current for MAIN, Imag = 119.9754 A Vtrans = 1.199691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:20:58 MAIN (V) Voltage Measurement, V = 8.517386 V 10:20:58 Temperature Measurement, Probe Number = 0, T = 27.537000 C 10:20:59 Temperature Measurement, Probe Number = 1, T = 26.566000 C 10:21:00 Temperature Measurement, Probe Number = 2, T = 19.952000 C 10:21:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321340 V 10:21:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321340 (V, A, ohm, ...), Measured Value = 28.351940 (C, atm, Hz, ...) 10:21:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.415331 V 10:21:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.415331 (V, A, ohm, ...), Measured Value = 29.657371 (C, atm, Hz, ...) 10:21:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658968 V 10:21:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658968 (V, A, ohm, ...), Measured Value = 124.422600 (C, atm, Hz, ...) 10:21:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093494 V 10:21:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093494 (V, A, ohm, ...), Measured Value = 7.012080 (C, atm, Hz, ...) 10:21:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 119.98 P1 = MAIN (V), Value = 8.52 P2 = Coil, Value = 27.54 P3 = Magnet Core, Value = 26.57 P4 = Ambient Temp (C), Value = 19.95 P5 = Supply Temp(C), Value = 28.35 P6 = Return Temp(C), Value = 29.66 P7 = Supply Pres(psi), Value = 124.42 P8 = Return Pres(psi), Value = 7.01 10:21:02 Magnetic Field Measurement Measuring the magnet strength... 10:21:02 Integrated Voltage Measurement... 10:21:03 Magnet Current for MAIN, Imag = 119.9756 A Vtrans = 1.199693 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:21:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056866001 Vs 10:21:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056831707 Vs 10:21:21 Magnet Current for MAIN, Imag = 119.9751 A Vtrans = 1.199688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:21:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056786425 Vs 10:21:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056813852 Vs 10:21:37 Magnet Current for MAIN, Imag = 119.9751 A Vtrans = 1.199688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:21:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056799904 Vs 10:21:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056802601 Vs 10:21:54 Magnet Current for MAIN, Imag = 119.9751 A Vtrans = 1.199688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:22:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056842813 Vs 10:22:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056823031 Vs 10:22:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056820792 +- 0.000020874 Vs 10:22:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.056820792 +- 0.000020874 Vs BL = -0.63134213 +- 0.00023194 Tm 10:22:13 Position moved: 0.000000 m 10:22:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.63134 0.00023 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.63134 0.00023 -0.63134 0.00000 10:22:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.63134 0.00023 SL = -0.6313421 +- 0.0002319 Tm^2/m^n 10:22:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.6313421 +- 0.0002319 Tm^2/m^n Remeasure 10:22:14 Magnetic Field Measurement Measuring the magnet strength... 10:22:14 Integrated Voltage Measurement... 10:22:14 Magnet Current for MAIN, Imag = 119.9754 A Vtrans = 1.199691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:22:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056840261 Vs 10:22:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056827061 Vs 10:22:32 Magnet Current for MAIN, Imag = 119.9751 A Vtrans = 1.199688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:22:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056822611 Vs 10:22:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056802335 Vs 10:22:49 Magnet Current for MAIN, Imag = 119.9749 A Vtrans = 1.199686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:22:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056830941 Vs 10:23:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056806685 Vs 10:23:05 Magnet Current for MAIN, Imag = 119.9749 A Vtrans = 1.199686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:23:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056822187 Vs 10:23:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.056800163 Vs 10:23:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.056819030 +- 0.000008928 Vs 10:23:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.056819030 +- 0.000008928 Vs BL = -0.63132256 +- 0.00009920 Tm 10:23:25 Position moved: 0.000000 m 10:23:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.63132 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.63132 0.00010 -0.63132 0.00000 10:23:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.63132 0.00010 SL = -0.6313226 +- 0.0000992 Tm^2/m^n 10:23:25 Magnet Strength Measurement Harmonic Number = 1 SL = -0.6313226 +- 0.0000992 Tm^2/m^n 10:23:28 Position moved: 0.000000 m 10:23:28 Magnet system MAIN current ramping to 100.0000 A... 10:23:50 Magnet Current for MAIN, Imag = 99.9889 A Vtrans = 0.999826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:23:50 MAIN (V) Voltage Measurement, V = 7.087757 V 10:23:51 Temperature Measurement, Probe Number = 0, T = 27.471000 C 10:23:52 Temperature Measurement, Probe Number = 1, T = 26.521000 C 10:23:52 Temperature Measurement, Probe Number = 2, T = 19.930000 C 10:23:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321594 V 10:23:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321594 (V, A, ohm, ...), Measured Value = 28.355471 (C, atm, Hz, ...) 10:23:54 Sensor Voltage Measurement, Sensor Number = 1, V = 2.397830 V 10:23:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.397830 (V, A, ohm, ...), Measured Value = 29.414311 (C, atm, Hz, ...) 10:23:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662386 V 10:23:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662386 (V, A, ohm, ...), Measured Value = 124.678942 (C, atm, Hz, ...) 10:23:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093554 V 10:23:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093554 (V, A, ohm, ...), Measured Value = 7.016557 (C, atm, Hz, ...) 10:23:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 99.99 P1 = MAIN (V), Value = 7.09 P2 = Coil, Value = 27.47 P3 = Magnet Core, Value = 26.52 P4 = Ambient Temp (C), Value = 19.93 P5 = Supply Temp(C), Value = 28.36 P6 = Return Temp(C), Value = 29.41 P7 = Supply Pres(psi), Value = 124.68 P8 = Return Pres(psi), Value = 7.02 10:23:55 Magnetic Field Measurement Measuring the magnet strength... 10:23:55 Integrated Voltage Measurement... 10:23:56 Magnet Current for MAIN, Imag = 99.9889 A Vtrans = 0.999826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:24:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047499963 Vs 10:24:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047497599 Vs 10:24:13 Magnet Current for MAIN, Imag = 99.9887 A Vtrans = 0.999824 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:24:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047509170 Vs 10:24:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047467300 Vs 10:24:30 Magnet Current for MAIN, Imag = 99.9889 A Vtrans = 0.999826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:24:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047447601 Vs 10:24:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047473702 Vs 10:24:46 Magnet Current for MAIN, Imag = 99.9888 A Vtrans = 0.999825 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:24:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047492491 Vs 10:25:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047490892 Vs 10:25:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047484840 +- 0.000014473 Vs 10:25:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.047484840 +- 0.000014473 Vs BL = -0.52760933 +- 0.00016081 Tm 10:25:06 Position moved: 0.000000 m 10:25:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.52761 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.52761 0.00016 -0.52761 0.00000 10:25:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.52761 0.00016 SL = -0.5276093 +- 0.0001608 Tm^2/m^n 10:25:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.5276093 +- 0.0001608 Tm^2/m^n Remeasure 10:25:06 Magnetic Field Measurement Measuring the magnet strength... 10:25:06 Integrated Voltage Measurement... 10:25:07 Magnet Current for MAIN, Imag = 99.9892 A Vtrans = 0.999829 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:25:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047476238 Vs 10:25:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047505414 Vs 10:25:24 Magnet Current for MAIN, Imag = 99.9891 A Vtrans = 0.999828 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:25:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047475108 Vs 10:25:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047510664 Vs 10:25:41 Magnet Current for MAIN, Imag = 99.9889 A Vtrans = 0.999826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:25:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047459330 Vs 10:25:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047474130 Vs 10:25:57 Magnet Current for MAIN, Imag = 99.9889 A Vtrans = 0.999826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:26:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047485734 Vs 10:26:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047520163 Vs 10:26:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047488348 +- 0.000013297 Vs 10:26:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.047488348 +- 0.000013297 Vs BL = -0.52764831 +- 0.00014775 Tm 10:26:17 Position moved: 0.000000 m 10:26:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.52765 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.52765 0.00015 -0.52765 0.00000 10:26:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.52765 0.00015 SL = -0.5276483 +- 0.0001477 Tm^2/m^n 10:26:17 Magnet Strength Measurement Harmonic Number = 1 SL = -0.5276483 +- 0.0001477 Tm^2/m^n Remeasure 10:26:17 Magnetic Field Measurement Measuring the magnet strength... 10:26:17 Integrated Voltage Measurement... 10:26:18 Magnet Current for MAIN, Imag = 99.9888 A Vtrans = 0.999825 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:26:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047440203 Vs 10:26:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047455681 Vs 10:26:36 Magnet Current for MAIN, Imag = 99.9888 A Vtrans = 0.999825 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:26:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047462854 Vs 10:26:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047478683 Vs 10:26:52 Magnet Current for MAIN, Imag = 99.9889 A Vtrans = 0.999826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:27:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047457873 Vs 10:27:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047516845 Vs 10:27:09 Magnet Current for MAIN, Imag = 99.9891 A Vtrans = 0.999828 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:27:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047447619 Vs 10:27:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.047451028 Vs 10:27:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.047463848 +- 0.000016314 Vs 10:27:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.047463848 +- 0.000016314 Vs BL = -0.52737609 +- 0.00018127 Tm 10:27:28 Position moved: 0.000000 m 10:27:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.52738 0.00018 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.52738 0.00018 -0.52738 0.00000 10:27:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.52738 0.00018 SL = -0.5273761 +- 0.0001813 Tm^2/m^n 10:27:28 Magnet Strength Measurement Harmonic Number = 1 SL = -0.5273761 +- 0.0001813 Tm^2/m^n 10:27:31 Position moved: 0.000000 m 10:27:31 Magnet system MAIN current ramping to 80.0000 A... 10:27:53 Magnet Current for MAIN, Imag = 79.9358 A Vtrans = 0.799295 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:27:54 MAIN (V) Voltage Measurement, V = 5.658666 V 10:27:55 Temperature Measurement, Probe Number = 0, T = 27.238000 C 10:27:55 Temperature Measurement, Probe Number = 1, T = 26.528000 C 10:27:56 Temperature Measurement, Probe Number = 2, T = 19.900000 C 10:27:57 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322064 V 10:27:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322064 (V, A, ohm, ...), Measured Value = 28.362003 (C, atm, Hz, ...) 10:27:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.361354 V 10:27:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361354 (V, A, ohm, ...), Measured Value = 28.907700 (C, atm, Hz, ...) 10:27:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660539 V 10:27:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660539 (V, A, ohm, ...), Measured Value = 124.540425 (C, atm, Hz, ...) 10:27:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093544 V 10:27:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093544 (V, A, ohm, ...), Measured Value = 7.015800 (C, atm, Hz, ...) 10:27:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 79.94 P1 = MAIN (V), Value = 5.66 P2 = Coil, Value = 27.24 P3 = Magnet Core, Value = 26.53 P4 = Ambient Temp (C), Value = 19.90 P5 = Supply Temp(C), Value = 28.36 P6 = Return Temp(C), Value = 28.91 P7 = Supply Pres(psi), Value = 124.54 P8 = Return Pres(psi), Value = 7.02 10:27:59 Magnetic Field Measurement Measuring the magnet strength... 10:27:59 Integrated Voltage Measurement... 10:28:00 Magnet Current for MAIN, Imag = 79.9358 A Vtrans = 0.799295 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:28:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038059253 Vs 10:28:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038103312 Vs 10:28:17 Magnet Current for MAIN, Imag = 79.9357 A Vtrans = 0.799294 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:28:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038069862 Vs 10:28:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038104428 Vs 10:28:34 Magnet Current for MAIN, Imag = 79.9357 A Vtrans = 0.799294 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:28:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038075297 Vs 10:28:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038106283 Vs 10:28:50 Magnet Current for MAIN, Imag = 79.9356 A Vtrans = 0.799293 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:28:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038062514 Vs 10:29:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038073160 Vs 10:29:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038081763 +- 0.000008727 Vs 10:29:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.038081763 +- 0.000008727 Vs BL = -0.42313071 +- 0.00009696 Tm 10:29:10 Position moved: 0.000000 m 10:29:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.42313 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.42313 0.00010 -0.42313 0.00000 10:29:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.42313 0.00010 SL = -0.4231307 +- 0.0000970 Tm^2/m^n 10:29:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4231307 +- 0.0000970 Tm^2/m^n Remeasure 10:29:10 Magnetic Field Measurement Measuring the magnet strength... 10:29:10 Integrated Voltage Measurement... 10:29:11 Magnet Current for MAIN, Imag = 79.9357 A Vtrans = 0.799294 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:29:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038078704 Vs 10:29:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038063271 Vs 10:29:28 Magnet Current for MAIN, Imag = 79.9353 A Vtrans = 0.799290 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:29:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038048884 Vs 10:29:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038054960 Vs 10:29:44 Magnet Current for MAIN, Imag = 79.9351 A Vtrans = 0.799288 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:29:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038055111 Vs 10:30:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038078965 Vs 10:30:01 Magnet Current for MAIN, Imag = 79.9352 A Vtrans = 0.799289 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:30:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038076200 Vs 10:30:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038101519 Vs 10:30:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038069702 +- 0.000013152 Vs 10:30:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.038069702 +- 0.000013152 Vs BL = -0.42299669 +- 0.00014613 Tm 10:30:21 Position moved: 0.000000 m 10:30:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.42300 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.42300 0.00015 -0.42300 0.00000 10:30:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.42300 0.00015 SL = -0.4229967 +- 0.0001461 Tm^2/m^n 10:30:21 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4229967 +- 0.0001461 Tm^2/m^n Remeasure 10:30:21 Magnetic Field Measurement Measuring the magnet strength... 10:30:21 Integrated Voltage Measurement... 10:30:22 Magnet Current for MAIN, Imag = 79.9351 A Vtrans = 0.799288 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:30:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038083313 Vs 10:30:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038084981 Vs 10:30:40 Magnet Current for MAIN, Imag = 79.9353 A Vtrans = 0.799289 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:30:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038068173 Vs 10:30:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038064846 Vs 10:30:56 Magnet Current for MAIN, Imag = 79.9352 A Vtrans = 0.799289 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:31:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038069055 Vs 10:31:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038076868 Vs 10:31:13 Magnet Current for MAIN, Imag = 79.9355 A Vtrans = 0.799292 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:31:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038071381 Vs 10:31:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038088261 Vs 10:31:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038075860 +- 0.000006712 Vs 10:31:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.038075860 +- 0.000006712 Vs BL = -0.42306511 +- 0.00007458 Tm 10:31:33 Position moved: 0.000000 m 10:31:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.42307 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.42307 0.00007 -0.42307 0.00000 10:31:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.42307 0.00007 SL = -0.4230651 +- 0.0000746 Tm^2/m^n 10:31:33 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4230651 +- 0.0000746 Tm^2/m^n 10:31:36 Position moved: 0.000000 m 10:31:36 Magnet system MAIN current ramping to 60.0000 A... 10:31:58 Magnet Current for MAIN, Imag = 59.9384 A Vtrans = 0.599321 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:31:59 MAIN (V) Voltage Measurement, V = 4.238659 V 10:31:59 Temperature Measurement, Probe Number = 0, T = 27.116000 C 10:32:00 Temperature Measurement, Probe Number = 1, T = 26.487000 C 10:32:00 Temperature Measurement, Probe Number = 2, T = 19.801000 C 10:32:01 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322232 V 10:32:01 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322232 (V, A, ohm, ...), Measured Value = 28.364333 (C, atm, Hz, ...) 10:32:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.329009 V 10:32:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329009 (V, A, ohm, ...), Measured Value = 28.458464 (C, atm, Hz, ...) 10:32:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658742 V 10:32:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658742 (V, A, ohm, ...), Measured Value = 124.405628 (C, atm, Hz, ...) 10:32:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093291 V 10:32:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093291 (V, A, ohm, ...), Measured Value = 6.996825 (C, atm, Hz, ...) 10:32:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 59.94 P1 = MAIN (V), Value = 4.24 P2 = Coil, Value = 27.12 P3 = Magnet Core, Value = 26.49 P4 = Ambient Temp (C), Value = 19.80 P5 = Supply Temp(C), Value = 28.36 P6 = Return Temp(C), Value = 28.46 P7 = Supply Pres(psi), Value = 124.41 P8 = Return Pres(psi), Value = 7.00 10:32:03 Magnetic Field Measurement Measuring the magnet strength... 10:32:03 Integrated Voltage Measurement... 10:32:04 Magnet Current for MAIN, Imag = 59.9382 A Vtrans = 0.599319 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:32:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028656431 Vs 10:32:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028706095 Vs 10:32:21 Magnet Current for MAIN, Imag = 59.9381 A Vtrans = 0.599318 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:32:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028658026 Vs 10:32:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028687471 Vs 10:32:38 Magnet Current for MAIN, Imag = 59.9383 A Vtrans = 0.599320 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:32:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028649087 Vs 10:32:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028701382 Vs 10:32:55 Magnet Current for MAIN, Imag = 59.9382 A Vtrans = 0.599318 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:33:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028659802 Vs 10:33:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.028707041 Vs 10:33:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.028678167 +- 0.000004335 Vs 10:33:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.028678167 +- 0.000004335 Vs BL = -0.31864630 +- 0.00004816 Tm 10:33:14 Position moved: 0.000000 m 10:33:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.31865 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.31865 0.00005 -0.31865 0.00000 10:33:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.31865 0.00005 SL = -0.3186463 +- 0.0000482 Tm^2/m^n 10:33:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3186463 +- 0.0000482 Tm^2/m^n 10:33:17 Position moved: 0.000000 m 10:33:17 Magnet system MAIN current ramping to 40.0000 A... 10:33:40 Magnet Current for MAIN, Imag = 39.9616 A Vtrans = 0.399553 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:33:40 MAIN (V) Voltage Measurement, V = 2.824142 V 10:33:41 Temperature Measurement, Probe Number = 0, T = 27.084000 C 10:33:41 Temperature Measurement, Probe Number = 1, T = 26.494000 C 10:33:42 Temperature Measurement, Probe Number = 2, T = 19.733000 C 10:33:43 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322205 V 10:33:43 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322205 (V, A, ohm, ...), Measured Value = 28.363962 (C, atm, Hz, ...) 10:33:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.316952 V 10:33:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.316952 (V, A, ohm, ...), Measured Value = 28.291000 (C, atm, Hz, ...) 10:33:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662029 V 10:33:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662029 (V, A, ohm, ...), Measured Value = 124.652152 (C, atm, Hz, ...) 10:33:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093236 V 10:33:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093236 (V, A, ohm, ...), Measured Value = 6.992730 (C, atm, Hz, ...) 10:33:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.96 P1 = MAIN (V), Value = 2.82 P2 = Coil, Value = 27.08 P3 = Magnet Core, Value = 26.49 P4 = Ambient Temp (C), Value = 19.73 P5 = Supply Temp(C), Value = 28.36 P6 = Return Temp(C), Value = 28.29 P7 = Supply Pres(psi), Value = 124.65 P8 = Return Pres(psi), Value = 6.99 10:33:45 Magnetic Field Measurement Measuring the magnet strength... 10:33:45 Integrated Voltage Measurement... 10:33:46 Magnet Current for MAIN, Imag = 39.9618 A Vtrans = 0.399555 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:33:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.019291771 Vs 10:34:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.019290268 Vs 10:34:03 Magnet Current for MAIN, Imag = 39.9618 A Vtrans = 0.399555 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:34:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.019283478 Vs 10:34:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.019276963 Vs 10:34:19 Magnet Current for MAIN, Imag = 39.9618 A Vtrans = 0.399555 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:34:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.019291156 Vs 10:34:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.019282957 Vs 10:34:36 Magnet Current for MAIN, Imag = 39.9619 A Vtrans = 0.399556 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:34:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.019276072 Vs 10:34:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.019281591 Vs 10:34:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.019284282 +- 0.000004982 Vs 10:34:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.019284282 +- 0.000004982 Vs BL = -0.21426980 +- 0.00005536 Tm 10:34:55 Position moved: 0.000000 m 10:34:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.21427 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.21427 0.00006 -0.21427 0.00000 10:34:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.21427 0.00006 SL = -0.2142698 +- 0.0000554 Tm^2/m^n 10:34:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2142698 +- 0.0000554 Tm^2/m^n Remeasure 10:34:56 Magnetic Field Measurement Measuring the magnet strength... 10:34:56 Integrated Voltage Measurement... 10:34:56 Magnet Current for MAIN, Imag = 39.9619 A Vtrans = 0.399556 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:35:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.019290579 Vs 10:35:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.019275125 Vs 10:35:14 Magnet Current for MAIN, Imag = 39.9619 A Vtrans = 0.399556 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:35:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.019273700 Vs 10:35:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.019294193 Vs 10:35:30 Magnet Current for MAIN, Imag = 39.9618 A Vtrans = 0.399555 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:35:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.019274459 Vs 10:35:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.019294313 Vs 10:35:47 Magnet Current for MAIN, Imag = 39.9617 A Vtrans = 0.399554 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:35:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.019259265 Vs 10:36:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.019308362 Vs 10:36:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.019283750 +- 0.000000560 Vs 10:36:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.019283750 +- 0.000000560 Vs BL = -0.21426388 +- 0.00000622 Tm 10:36:07 Position moved: 0.000000 m 10:36:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.21426 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.21426 0.00001 -0.21426 0.00000 10:36:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.21426 0.00001 SL = -0.2142639 +- 0.0000062 Tm^2/m^n 10:36:07 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2142639 +- 0.0000062 Tm^2/m^n 10:36:10 Position moved: 0.000000 m 10:36:10 Magnet system MAIN current ramping to 20.0000 A... 10:36:32 Magnet Current for MAIN, Imag = 19.9764 A Vtrans = 0.199701 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:36:32 MAIN (V) Voltage Measurement, V = 1.410904 V 10:36:33 Temperature Measurement, Probe Number = 0, T = 27.024000 C 10:36:34 Temperature Measurement, Probe Number = 1, T = 26.468000 C 10:36:34 Temperature Measurement, Probe Number = 2, T = 19.772000 C 10:36:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322580 V 10:36:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322580 (V, A, ohm, ...), Measured Value = 28.369171 (C, atm, Hz, ...) 10:36:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.297462 V 10:36:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.297462 (V, A, ohm, ...), Measured Value = 28.020313 (C, atm, Hz, ...) 10:36:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664467 V 10:36:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664467 (V, A, ohm, ...), Measured Value = 124.834995 (C, atm, Hz, ...) 10:36:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093077 V 10:36:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093077 (V, A, ohm, ...), Measured Value = 6.980812 (C, atm, Hz, ...) 10:36:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.98 P1 = MAIN (V), Value = 1.41 P2 = Coil, Value = 27.02 P3 = Magnet Core, Value = 26.47 P4 = Ambient Temp (C), Value = 19.77 P5 = Supply Temp(C), Value = 28.37 P6 = Return Temp(C), Value = 28.02 P7 = Supply Pres(psi), Value = 124.83 P8 = Return Pres(psi), Value = 6.98 10:36:37 Magnetic Field Measurement Measuring the magnet strength... 10:36:37 Integrated Voltage Measurement... 10:36:38 Magnet Current for MAIN, Imag = 19.9767 A Vtrans = 0.199704 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:36:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009875505 Vs 10:36:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009904372 Vs 10:36:55 Magnet Current for MAIN, Imag = 19.9766 A Vtrans = 0.199703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:37:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009874927 Vs 10:37:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009893941 Vs 10:37:12 Magnet Current for MAIN, Imag = 19.9766 A Vtrans = 0.199703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:37:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009874897 Vs 10:37:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009884742 Vs 10:37:28 Magnet Current for MAIN, Imag = 19.9765 A Vtrans = 0.199702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:37:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009883507 Vs 10:37:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009887270 Vs 10:37:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009884895 +- 0.000003594 Vs 10:37:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.009884895 +- 0.000003594 Vs BL = -0.10983217 +- 0.00003993 Tm 10:37:48 Position moved: 0.000000 m 10:37:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10983 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10983 0.00004 -0.10983 0.00000 10:37:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10983 0.00004 SL = -0.1098322 +- 0.0000399 Tm^2/m^n 10:37:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1098322 +- 0.0000399 Tm^2/m^n Remeasure 10:37:48 Magnetic Field Measurement Measuring the magnet strength... 10:37:48 Integrated Voltage Measurement... 10:37:49 Magnet Current for MAIN, Imag = 19.9765 A Vtrans = 0.199702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:37:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009882184 Vs 10:38:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009899672 Vs 10:38:06 Magnet Current for MAIN, Imag = 19.9767 A Vtrans = 0.199704 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:38:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009876655 Vs 10:38:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009889921 Vs 10:38:23 Magnet Current for MAIN, Imag = 19.9766 A Vtrans = 0.199703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:38:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009871064 Vs 10:38:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009890791 Vs 10:38:39 Magnet Current for MAIN, Imag = 19.9766 A Vtrans = 0.199703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:38:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009871638 Vs 10:38:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009894396 Vs 10:38:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009884540 +- 0.000003799 Vs 10:38:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.009884540 +- 0.000003799 Vs BL = -0.10982822 +- 0.00004222 Tm 10:38:59 Position moved: 0.000000 m 10:38:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10983 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10983 0.00004 -0.10983 0.00000 10:38:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10983 0.00004 SL = -0.1098282 +- 0.0000422 Tm^2/m^n 10:38:59 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1098282 +- 0.0000422 Tm^2/m^n Remeasure 10:38:59 Magnetic Field Measurement Measuring the magnet strength... 10:38:59 Integrated Voltage Measurement... 10:39:00 Magnet Current for MAIN, Imag = 19.9766 A Vtrans = 0.199703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:39:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009881259 Vs 10:39:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009896134 Vs 10:39:17 Magnet Current for MAIN, Imag = 19.9765 A Vtrans = 0.199702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:39:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009868536 Vs 10:39:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009897289 Vs 10:39:34 Magnet Current for MAIN, Imag = 19.9766 A Vtrans = 0.199703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:39:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009875572 Vs 10:39:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009900031 Vs 10:39:50 Magnet Current for MAIN, Imag = 19.9763 A Vtrans = 0.199700 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:39:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009872031 Vs 10:40:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009890509 Vs 10:40:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009885170 +- 0.000003149 Vs 10:40:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.009885170 +- 0.000003149 Vs BL = -0.10983522 +- 0.00003499 Tm 10:40:10 Position moved: 0.000000 m 10:40:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10984 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10984 0.00003 -0.10984 0.00000 10:40:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10984 0.00003 SL = -0.1098352 +- 0.0000350 Tm^2/m^n 10:40:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1098352 +- 0.0000350 Tm^2/m^n Remeasure 10:40:10 Magnetic Field Measurement Measuring the magnet strength... 10:40:10 Integrated Voltage Measurement... 10:40:11 Magnet Current for MAIN, Imag = 19.9765 A Vtrans = 0.199702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:40:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009877125 Vs 10:40:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009898818 Vs 10:40:28 Magnet Current for MAIN, Imag = 19.9765 A Vtrans = 0.199702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:40:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009876517 Vs 10:40:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009894079 Vs 10:40:45 Magnet Current for MAIN, Imag = 19.9765 A Vtrans = 0.199702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:40:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009889253 Vs 10:41:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009884894 Vs 10:41:02 Magnet Current for MAIN, Imag = 19.9765 A Vtrans = 0.199702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:41:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009890857 Vs 10:41:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.009875133 Vs 10:41:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.009885835 +- 0.000001901 Vs 10:41:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.009885835 +- 0.000001901 Vs BL = -0.10984261 +- 0.00002112 Tm 10:41:21 Position moved: 0.000000 m 10:41:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10984 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10984 0.00002 -0.10984 0.00000 10:41:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10984 0.00002 SL = -0.1098426 +- 0.0000211 Tm^2/m^n 10:41:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1098426 +- 0.0000211 Tm^2/m^n 10:41:24 Position moved: 0.000000 m 10:41:24 Magnet system MAIN current ramping to 0.0000 A... 10:41:47 Magnet Current for MAIN, Imag = 0.0090 A Vtrans = 0.000026 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:41:47 MAIN (V) Voltage Measurement, V = 0.000561 V 10:41:48 Temperature Measurement, Probe Number = 0, T = 26.925000 C 10:41:49 Temperature Measurement, Probe Number = 1, T = 26.390000 C 10:41:49 Temperature Measurement, Probe Number = 2, T = 19.773000 C 10:41:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321997 V 10:41:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321997 (V, A, ohm, ...), Measured Value = 28.361068 (C, atm, Hz, ...) 10:41:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.267080 V 10:41:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.267080 (V, A, ohm, ...), Measured Value = 27.598333 (C, atm, Hz, ...) 10:41:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657989 V 10:41:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657989 (V, A, ohm, ...), Measured Value = 124.349190 (C, atm, Hz, ...) 10:41:52 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092929 V 10:41:52 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092929 (V, A, ohm, ...), Measured Value = 6.969660 (C, atm, Hz, ...) 10:41:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.01 P1 = MAIN (V), Value = 0.00 P2 = Coil, Value = 26.93 P3 = Magnet Core, Value = 26.39 P4 = Ambient Temp (C), Value = 19.77 P5 = Supply Temp(C), Value = 28.36 P6 = Return Temp(C), Value = 27.60 P7 = Supply Pres(psi), Value = 124.35 P8 = Return Pres(psi), Value = 6.97 10:41:52 Magnetic Field Measurement Measuring the magnet strength... 10:41:52 Integrated Voltage Measurement... 10:41:53 Magnet Current for MAIN, Imag = 0.0089 A Vtrans = 0.000026 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:42:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000493403 Vs 10:42:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000497701 Vs 10:42:10 Magnet Current for MAIN, Imag = 0.0092 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:42:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000489479 Vs 10:42:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000503297 Vs 10:42:27 Magnet Current for MAIN, Imag = 0.0089 A Vtrans = 0.000026 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:42:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000484065 Vs 10:42:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000508006 Vs 10:42:43 Magnet Current for MAIN, Imag = 0.0089 A Vtrans = 0.000026 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006304 A 10:42:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000479790 Vs 10:42:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000508241 Vs 10:42:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000495498 +- 0.000000906 Vs 10:42:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.000495498 +- 0.000000906 Vs BL = -0.00550553 +- 0.00001007 Tm 10:43:03 Position moved: 0.000000 m 10:43:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00551 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00551 0.00001 -0.00551 0.00000 10:43:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00551 0.00001 SL = -0.0055055 +- 0.0000101 Tm^2/m^n 10:43:03 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0055055 +- 0.0000101 Tm^2/m^n 10:43:06 Position moved: 0.000000 m 10:43:09 Position moved: 0.000000 m 10:43:12 Magnet system MAIN current ramping to 0.0000 A...