SLAC Magnetic Measurements Date: 09-13-2016 Time: 18:30:37 Project: LCLS2 Magnet Type: Dipole Magnet Name: BX31b Serial Number: 16102 Run Number: 8 Measurement Device: 1wire Operator: sda Comment: Integral strength vs current from 0 to 170 to 0 amps for Main. Wire move = 1 cm. Standardization for Main : 3 cycles from 0.0 A to 170.0 A to 0.0 A Test Currents for Main (A): 0.00 15.00 30.00 45.00 60.00 75.00 90.00 105.00 120.00 135.00 150.00 165.00 170.00 165.00 150.00 135.00 120.00 105.00 90.00 75.00 60.00 45.00 30.00 15.00 0.00 18:31:03 Position moved: 0.000000 m 18:31:07 Magnet Current for Main , Imag = 0.0236 A Vtrans = 0.000236 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:31:08 Magnet Current for Main , Imag = 0.0236 A Vtrans = 0.000236 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:31:08 Magnet Current for Main , Imag = 0.0236 A Vtrans = 0.000236 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:31:09 Magnet Current for Main , Imag = 0.0236 A Vtrans = 0.000236 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 18:31:09 Magnet Avgerage Current Measurement for Main : Imag = 0.0236 +- 0.0000 A 18:31:22 Initial Zero Current Measurement for Main , Imag_zero = 0.0235723 A 18:31:22 Ambient Measurement Device(s) Being Used, type = None 18:31:22 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 18:31:23 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 18:31:23 XMAG Device(s) Being Used, type = None 18:31:23 Ambient Measurement Device(s) Being Used, type = None 18:31:23 Magnet system Main current ramping to 170.0000 A... 18:32:20 Magnet system Main current ramping to 0.0000 A... 18:33:18 Magnet system Main current ramping to 170.0000 A... 18:34:16 Magnet system Main current ramping to 0.0000 A... 18:35:14 Magnet system Main current ramping to 170.0000 A... 18:36:12 Magnet system Main current ramping to 0.0000 A... 18:37:13 Position moved: 0.000000 m 18:37:15 Magnet system Main current ramping to 0.0000 A... 18:37:26 Magnet Current for Main , Imag = 0.0079 A Vtrans = 0.000315 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:37:27 MAIN Voltage Measurement, V = 0.000653 V 18:37:28 Temperature Measurement, Probe Number = 0, T = 29.146000 C 18:37:28 Temperature Measurement, Probe Number = 1, T = 29.495000 C 18:37:29 Temperature Measurement, Probe Number = 2, T = 26.513000 C 18:37:29 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = MAIN, Value = 0.00 P2 = Steel, Value = 29.15 P3 = Coil, Value = 29.50 P4 = Ambient Temp, Value = 26.51 18:37:29 Magnetic Field Measurement Measuring the magnet strength... 18:37:29 Integrated Voltage Measurement... 18:37:30 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000316 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:37:37 Voltage Offset Correction: v_off_ini = -0.000001519 V, v_off_fin = -0.000002185 V 18:37:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035859 Vs 18:37:44 Voltage Offset Correction: v_off_ini = -0.000001452 V, v_off_fin = -0.000002238 V 18:37:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035389 Vs 18:37:45 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:37:51 Voltage Offset Correction: v_off_ini = -0.000001593 V, v_off_fin = -0.000001743 V 18:37:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035903 Vs 18:37:58 Voltage Offset Correction: v_off_ini = -0.000001472 V, v_off_fin = -0.000001858 V 18:37:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035508 Vs 18:37:58 Magnet Current for Main , Imag = 0.0077 A Vtrans = 0.000313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:38:05 Voltage Offset Correction: v_off_ini = -0.000001355 V, v_off_fin = -0.000001911 V 18:38:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035806 Vs 18:38:12 Voltage Offset Correction: v_off_ini = -0.000001338 V, v_off_fin = -0.000001447 V 18:38:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035720 Vs 18:38:12 Magnet Current for Main , Imag = 0.0076 A Vtrans = 0.000312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:38:19 Voltage Offset Correction: v_off_ini = -0.000001326 V, v_off_fin = -0.000001629 V 18:38:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035793 Vs 18:38:26 Voltage Offset Correction: v_off_ini = -0.000001272 V, v_off_fin = -0.000002087 V 18:38:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035395 Vs 18:38:26 Magnet Current for Main , Imag = 0.0076 A Vtrans = 0.000311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:38:33 Voltage Offset Correction: v_off_ini = -0.000001330 V, v_off_fin = -0.000000763 V 18:38:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035475 Vs 18:38:40 Voltage Offset Correction: v_off_ini = -0.000001249 V, v_off_fin = -0.000000979 V 18:38:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035911 Vs 18:38:40 Magnet Current for Main , Imag = 0.0074 A Vtrans = 0.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:38:47 Voltage Offset Correction: v_off_ini = -0.000001331 V, v_off_fin = -0.000001104 V 18:38:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035730 Vs 18:38:53 Voltage Offset Correction: v_off_ini = -0.000001086 V, v_off_fin = -0.000001441 V 18:38:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000035627 Vs 18:38:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000035676 +- 0.000000055 Vs 18:38:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000035676 +- 0.000000055 Vs BL = 0.00356765 +- 0.00000549 Tm 18:38:57 Position moved: 0.000000 m 18:38:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00357 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00357 0.00001 0.00357 0.00000 18:38:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00357 0.00001 SL = 0.0035676 +- 0.0000055 Tm^2/m^n 18:38:57 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0035676 +- 0.0000055 Tm^2/m^n 18:39:00 Position moved: 0.000000 m 18:39:00 Magnet system Main current ramping to 15.0000 A... 18:39:15 Magnet Current for Main , Imag = 14.9652 A Vtrans = 0.149887 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:39:16 MAIN Voltage Measurement, V = 1.059435 V 18:39:16 Temperature Measurement, Probe Number = 0, T = 29.111000 C 18:39:17 Temperature Measurement, Probe Number = 1, T = 29.132000 C 18:39:18 Temperature Measurement, Probe Number = 2, T = 26.516000 C 18:39:18 Magnet Test Parameter Measurements P0 = Main , Value = 14.97 P1 = MAIN, Value = 1.06 P2 = Steel, Value = 29.11 P3 = Coil, Value = 29.13 P4 = Ambient Temp, Value = 26.52 18:39:18 Magnetic Field Measurement Measuring the magnet strength... 18:39:18 Integrated Voltage Measurement... 18:39:18 Magnet Current for Main , Imag = 14.9654 A Vtrans = 0.149889 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:39:26 Voltage Offset Correction: v_off_ini = -0.000000826 V, v_off_fin = -0.000001591 V 18:39:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000641310 Vs 18:39:33 Voltage Offset Correction: v_off_ini = -0.000001106 V, v_off_fin = -0.000006645 V 18:39:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000638765 Vs 18:39:33 Magnet Current for Main , Imag = 14.9650 A Vtrans = 0.149886 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:39:40 Voltage Offset Correction: v_off_ini = -0.000001536 V, v_off_fin = 0.000003490 V 18:39:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000638969 Vs 18:39:47 Voltage Offset Correction: v_off_ini = -0.000001384 V, v_off_fin = -0.000000813 V 18:39:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000641916 Vs 18:39:47 Magnet Current for Main , Imag = 14.9649 A Vtrans = 0.149885 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:39:54 Voltage Offset Correction: v_off_ini = -0.000001234 V, v_off_fin = -0.000002407 V 18:39:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000642067 Vs 18:40:00 Voltage Offset Correction: v_off_ini = -0.000001219 V, v_off_fin = 0.000006751 V 18:40:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000645672 Vs 18:40:01 Magnet Current for Main , Imag = 14.9648 A Vtrans = 0.149884 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:40:08 Voltage Offset Correction: v_off_ini = -0.000001406 V, v_off_fin = -0.000008305 V 18:40:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000645310 Vs 18:40:14 Voltage Offset Correction: v_off_ini = -0.000001206 V, v_off_fin = -0.000001277 V 18:40:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000641634 Vs 18:40:15 Magnet Current for Main , Imag = 14.9647 A Vtrans = 0.149883 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:40:22 Voltage Offset Correction: v_off_ini = -0.000001503 V, v_off_fin = -0.000001163 V 18:40:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000641344 Vs 18:40:28 Voltage Offset Correction: v_off_ini = -0.000001448 V, v_off_fin = 0.000010862 V 18:40:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000648097 Vs 18:40:29 Magnet Current for Main , Imag = 14.9644 A Vtrans = 0.149880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:40:35 Voltage Offset Correction: v_off_ini = -0.000001573 V, v_off_fin = -0.000000850 V 18:40:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000641216 Vs 18:40:42 Voltage Offset Correction: v_off_ini = -0.000001618 V, v_off_fin = -0.000002468 V 18:40:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000640997 Vs 18:40:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000642275 +- 0.000001811 Vs 18:40:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000642275 +- 0.000001811 Vs BL = 0.06422748 +- 0.00018114 Tm 18:40:46 Position moved: 0.000000 m 18:40:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.06423 0.00018 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.06423 0.00018 0.06423 0.00000 18:40:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.06423 0.00018 SL = 0.0642275 +- 0.0001811 Tm^2/m^n 18:40:46 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0642275 +- 0.0001811 Tm^2/m^n 18:40:49 Position moved: 0.000000 m 18:40:49 Magnet system Main current ramping to 30.0000 A... 18:41:04 Magnet Current for Main , Imag = 29.9867 A Vtrans = 0.300102 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:41:04 MAIN Voltage Measurement, V = 2.122353 V 18:41:05 Temperature Measurement, Probe Number = 0, T = 29.082000 C 18:41:06 Temperature Measurement, Probe Number = 1, T = 29.043000 C 18:41:06 Temperature Measurement, Probe Number = 2, T = 26.529000 C 18:41:06 Magnet Test Parameter Measurements P0 = Main , Value = 29.99 P1 = MAIN, Value = 2.12 P2 = Steel, Value = 29.08 P3 = Coil, Value = 29.04 P4 = Ambient Temp, Value = 26.53 18:41:06 Magnetic Field Measurement Measuring the magnet strength... 18:41:06 Integrated Voltage Measurement... 18:41:07 Magnet Current for Main , Imag = 29.9869 A Vtrans = 0.300105 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:41:15 Voltage Offset Correction: v_off_ini = -0.000001576 V, v_off_fin = -0.000015395 V 18:41:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001262282 Vs 18:41:21 Voltage Offset Correction: v_off_ini = -0.000001662 V, v_off_fin = 0.000005411 V 18:41:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001258625 Vs 18:41:22 Magnet Current for Main , Imag = 29.9869 A Vtrans = 0.300105 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:41:28 Voltage Offset Correction: v_off_ini = -0.000001510 V, v_off_fin = 0.000000447 V 18:41:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001254103 Vs 18:41:35 Voltage Offset Correction: v_off_ini = -0.000001690 V, v_off_fin = -0.000015984 V 18:41:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001247232 Vs 18:41:36 Magnet Current for Main , Imag = 29.9869 A Vtrans = 0.300105 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:41:42 Voltage Offset Correction: v_off_ini = -0.000001594 V, v_off_fin = 0.000001345 V 18:41:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001253285 Vs 18:41:49 Voltage Offset Correction: v_off_ini = -0.000001496 V, v_off_fin = -0.000002958 V 18:41:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001253805 Vs 18:41:49 Magnet Current for Main , Imag = 29.9868 A Vtrans = 0.300104 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:41:56 Voltage Offset Correction: v_off_ini = -0.000001604 V, v_off_fin = 0.000004020 V 18:41:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001251652 Vs 18:42:02 Voltage Offset Correction: v_off_ini = -0.000001635 V, v_off_fin = 0.000022197 V 18:42:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001267136 Vs 18:42:03 Magnet Current for Main , Imag = 29.9867 A Vtrans = 0.300103 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:42:10 Voltage Offset Correction: v_off_ini = -0.000001292 V, v_off_fin = -0.000009339 V 18:42:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001258909 Vs 18:42:16 Voltage Offset Correction: v_off_ini = -0.000001339 V, v_off_fin = -0.000007701 V 18:42:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001251377 Vs 18:42:17 Magnet Current for Main , Imag = 29.9868 A Vtrans = 0.300103 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:42:24 Voltage Offset Correction: v_off_ini = -0.000001863 V, v_off_fin = -0.000002315 V 18:42:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001254962 Vs 18:42:30 Voltage Offset Correction: v_off_ini = -0.000001641 V, v_off_fin = -0.000003095 V 18:42:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001253817 Vs 18:42:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001255599 +- 0.000003371 Vs 18:42:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001255599 +- 0.000003371 Vs BL = 0.12555986 +- 0.00033709 Tm 18:42:34 Position moved: 0.000000 m 18:42:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.12556 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.12556 0.00034 0.12556 0.00000 18:42:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12556 0.00034 SL = 0.1255599 +- 0.0003371 Tm^2/m^n 18:42:34 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1255599 +- 0.0003371 Tm^2/m^n 18:42:37 Position moved: 0.000000 m 18:42:37 Magnet system Main current ramping to 45.0000 A... 18:42:52 Magnet Current for Main , Imag = 45.0115 A Vtrans = 0.450351 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:42:52 MAIN Voltage Measurement, V = 3.186025 V 18:42:53 Temperature Measurement, Probe Number = 0, T = 29.068000 C 18:42:54 Temperature Measurement, Probe Number = 1, T = 29.027000 C 18:42:54 Temperature Measurement, Probe Number = 2, T = 26.486000 C 18:42:54 Magnet Test Parameter Measurements P0 = Main , Value = 45.01 P1 = MAIN, Value = 3.19 P2 = Steel, Value = 29.07 P3 = Coil, Value = 29.03 P4 = Ambient Temp, Value = 26.49 18:42:54 Magnetic Field Measurement Measuring the magnet strength... 18:42:54 Integrated Voltage Measurement... 18:42:55 Magnet Current for Main , Imag = 45.0117 A Vtrans = 0.450353 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:43:03 Voltage Offset Correction: v_off_ini = -0.000001541 V, v_off_fin = -0.000013059 V 18:43:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001876646 Vs 18:43:09 Voltage Offset Correction: v_off_ini = -0.000001708 V, v_off_fin = 0.000006577 V 18:43:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001874875 Vs 18:43:10 Magnet Current for Main , Imag = 45.0115 A Vtrans = 0.450351 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:43:17 Voltage Offset Correction: v_off_ini = -0.000001648 V, v_off_fin = -0.000001016 V 18:43:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001870545 Vs 18:43:23 Voltage Offset Correction: v_off_ini = -0.000001435 V, v_off_fin = 0.000031845 V 18:43:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001887972 Vs 18:43:24 Magnet Current for Main , Imag = 45.0115 A Vtrans = 0.450350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:43:30 Voltage Offset Correction: v_off_ini = -0.000001728 V, v_off_fin = 0.000002909 V 18:43:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001867828 Vs 18:43:37 Voltage Offset Correction: v_off_ini = -0.000001800 V, v_off_fin = -0.000017037 V 18:43:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001861762 Vs 18:43:38 Magnet Current for Main , Imag = 45.0113 A Vtrans = 0.450349 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:43:44 Voltage Offset Correction: v_off_ini = -0.000001607 V, v_off_fin = -0.000002687 V 18:43:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001870865 Vs 18:43:51 Voltage Offset Correction: v_off_ini = -0.000001237 V, v_off_fin = -0.000011857 V 18:43:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001864415 Vs 18:43:52 Magnet Current for Main , Imag = 45.0113 A Vtrans = 0.450348 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:43:58 Voltage Offset Correction: v_off_ini = -0.000001540 V, v_off_fin = -0.000022397 V 18:43:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001881379 Vs 18:44:05 Voltage Offset Correction: v_off_ini = -0.000001351 V, v_off_fin = 0.000032435 V 18:44:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001888157 Vs 18:44:05 Magnet Current for Main , Imag = 45.0114 A Vtrans = 0.450350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:44:12 Voltage Offset Correction: v_off_ini = -0.000001674 V, v_off_fin = 0.000016745 V 18:44:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001860737 Vs 18:44:18 Voltage Offset Correction: v_off_ini = -0.000001330 V, v_off_fin = -0.000032015 V 18:44:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001854050 Vs 18:44:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001871603 +- 0.000009248 Vs 18:44:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001871603 +- 0.000009248 Vs BL = 0.18716025 +- 0.00092483 Tm 18:44:22 Position moved: 0.000000 m 18:44:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.18716 0.00092 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.18716 0.00092 0.18716 0.00000 18:44:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.18716 0.00092 SL = 0.1871603 +- 0.0009248 Tm^2/m^n 18:44:22 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1871603 +- 0.0009248 Tm^2/m^n 18:44:25 Position moved: 0.000000 m 18:44:25 Magnet system Main current ramping to 60.0000 A... 18:44:40 Magnet Current for Main , Imag = 60.0330 A Vtrans = 0.600566 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:44:41 MAIN Voltage Measurement, V = 4.250444 V 18:44:41 Temperature Measurement, Probe Number = 0, T = 29.056000 C 18:44:42 Temperature Measurement, Probe Number = 1, T = 29.047000 C 18:44:43 Temperature Measurement, Probe Number = 2, T = 26.522000 C 18:44:43 Magnet Test Parameter Measurements P0 = Main , Value = 60.03 P1 = MAIN, Value = 4.25 P2 = Steel, Value = 29.06 P3 = Coil, Value = 29.05 P4 = Ambient Temp, Value = 26.52 18:44:43 Magnetic Field Measurement Measuring the magnet strength... 18:44:43 Integrated Voltage Measurement... 18:44:43 Magnet Current for Main , Imag = 60.0330 A Vtrans = 0.600566 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:44:51 Voltage Offset Correction: v_off_ini = -0.000004155 V, v_off_fin = 0.000007349 V 18:44:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002484140 Vs 18:44:57 Voltage Offset Correction: v_off_ini = -0.000001128 V, v_off_fin = 0.000049683 V 18:44:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002514365 Vs 18:44:58 Magnet Current for Main , Imag = 60.0329 A Vtrans = 0.600564 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:45:05 Voltage Offset Correction: v_off_ini = -0.000001618 V, v_off_fin = 0.000005031 V 18:45:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002484848 Vs 18:45:11 Voltage Offset Correction: v_off_ini = -0.000000918 V, v_off_fin = -0.000009438 V 18:45:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002483015 Vs 18:45:12 Magnet Current for Main , Imag = 60.0330 A Vtrans = 0.600565 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:45:18 Voltage Offset Correction: v_off_ini = -0.000001517 V, v_off_fin = 0.000025412 V 18:45:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002473992 Vs 18:45:25 Voltage Offset Correction: v_off_ini = -0.000001482 V, v_off_fin = 0.000035535 V 18:45:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002507125 Vs 18:45:26 Magnet Current for Main , Imag = 60.0329 A Vtrans = 0.600564 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:45:32 Voltage Offset Correction: v_off_ini = -0.000001216 V, v_off_fin = -0.000028918 V 18:45:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002502050 Vs 18:45:39 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = -0.000011891 V 18:45:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002482081 Vs 18:45:39 Magnet Current for Main , Imag = 60.0330 A Vtrans = 0.600566 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:45:46 Voltage Offset Correction: v_off_ini = -0.000002167 V, v_off_fin = -0.000029716 V 18:45:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002502693 Vs 18:45:53 Voltage Offset Correction: v_off_ini = -0.000001439 V, v_off_fin = 0.000048565 V 18:45:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002513937 Vs 18:45:53 Magnet Current for Main , Imag = 60.0330 A Vtrans = 0.600566 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:46:00 Voltage Offset Correction: v_off_ini = -0.000001714 V, v_off_fin = 0.000004727 V 18:46:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002483831 Vs 18:46:06 Voltage Offset Correction: v_off_ini = -0.000000951 V, v_off_fin = -0.000024081 V 18:46:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002475319 Vs 18:46:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002492283 +- 0.000009486 Vs 18:46:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.002492283 +- 0.000009486 Vs BL = 0.24922830 +- 0.00094855 Tm 18:46:10 Position moved: 0.000000 m 18:46:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.24923 0.00095 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.24923 0.00095 0.24923 0.00000 18:46:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.24923 0.00095 SL = 0.2492283 +- 0.0009486 Tm^2/m^n 18:46:10 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2492283 +- 0.0009486 Tm^2/m^n 18:46:13 Position moved: 0.000000 m 18:46:13 Magnet system Main current ramping to 75.0000 A... 18:46:28 Magnet Current for Main , Imag = 74.9842 A Vtrans = 0.750078 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:46:29 MAIN Voltage Measurement, V = 5.311344 V 18:46:29 Temperature Measurement, Probe Number = 0, T = 29.030000 C 18:46:30 Temperature Measurement, Probe Number = 1, T = 29.098000 C 18:46:30 Temperature Measurement, Probe Number = 2, T = 26.541000 C 18:46:30 Magnet Test Parameter Measurements P0 = Main , Value = 74.98 P1 = MAIN, Value = 5.31 P2 = Steel, Value = 29.03 P3 = Coil, Value = 29.10 P4 = Ambient Temp, Value = 26.54 18:46:30 Magnetic Field Measurement Measuring the magnet strength... 18:46:30 Integrated Voltage Measurement... 18:46:31 Magnet Current for Main , Imag = 74.9845 A Vtrans = 0.750080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:46:39 Voltage Offset Correction: v_off_ini = -0.000002765 V, v_off_fin = 0.000027514 V 18:46:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003089182 Vs 18:46:45 Voltage Offset Correction: v_off_ini = -0.000001409 V, v_off_fin = -0.000060140 V 18:46:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003072986 Vs 18:46:46 Magnet Current for Main , Imag = 74.9843 A Vtrans = 0.750078 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:46:53 Voltage Offset Correction: v_off_ini = -0.000001272 V, v_off_fin = -0.000005454 V 18:46:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003104770 Vs 18:46:59 Voltage Offset Correction: v_off_ini = -0.000001134 V, v_off_fin = -0.000066654 V 18:46:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003068900 Vs 18:47:00 Magnet Current for Main , Imag = 74.9845 A Vtrans = 0.750081 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:47:07 Voltage Offset Correction: v_off_ini = -0.000001691 V, v_off_fin = -0.000020858 V 18:47:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003113421 Vs 18:47:13 Voltage Offset Correction: v_off_ini = -0.000001279 V, v_off_fin = -0.000057511 V 18:47:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003073453 Vs 18:47:14 Magnet Current for Main , Imag = 74.9846 A Vtrans = 0.750082 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:47:20 Voltage Offset Correction: v_off_ini = -0.000001849 V, v_off_fin = 0.000014087 V 18:47:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003095238 Vs 18:47:27 Voltage Offset Correction: v_off_ini = -0.000001261 V, v_off_fin = 0.000052254 V 18:47:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003131652 Vs 18:47:28 Magnet Current for Main , Imag = 74.9846 A Vtrans = 0.750082 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:47:34 Voltage Offset Correction: v_off_ini = -0.000001531 V, v_off_fin = 0.000027126 V 18:47:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003088621 Vs 18:47:41 Voltage Offset Correction: v_off_ini = -0.000001450 V, v_off_fin = -0.000063786 V 18:47:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003070512 Vs 18:47:42 Magnet Current for Main , Imag = 74.9846 A Vtrans = 0.750081 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:47:48 Voltage Offset Correction: v_off_ini = -0.000001507 V, v_off_fin = -0.000028571 V 18:47:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003117456 Vs 18:47:55 Voltage Offset Correction: v_off_ini = -0.000001391 V, v_off_fin = 0.000026584 V 18:47:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003118197 Vs 18:47:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003095366 +- 0.000015063 Vs 18:47:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003095366 +- 0.000015063 Vs BL = 0.30953657 +- 0.00150634 Tm 18:47:59 Position moved: 0.000000 m 18:47:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.30954 0.00151 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.30954 0.00151 0.30954 0.00000 18:47:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.30954 0.00151 SL = 0.3095366 +- 0.0015063 Tm^2/m^n 18:47:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3095366 +- 0.0015063 Tm^2/m^n 18:48:01 Position moved: 0.000000 m 18:48:01 Magnet system Main current ramping to 90.0000 A... 18:48:16 Magnet Current for Main , Imag = 90.0019 A Vtrans = 0.900254 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:48:17 MAIN Voltage Measurement, V = 6.378846 V 18:48:18 Temperature Measurement, Probe Number = 0, T = 29.009000 C 18:48:18 Temperature Measurement, Probe Number = 1, T = 29.174000 C 18:48:19 Temperature Measurement, Probe Number = 2, T = 26.510000 C 18:48:19 Magnet Test Parameter Measurements P0 = Main , Value = 90.00 P1 = MAIN, Value = 6.38 P2 = Steel, Value = 29.01 P3 = Coil, Value = 29.17 P4 = Ambient Temp, Value = 26.51 18:48:19 Magnetic Field Measurement Measuring the magnet strength... 18:48:19 Integrated Voltage Measurement... 18:48:20 Magnet Current for Main , Imag = 90.0021 A Vtrans = 0.900257 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:48:27 Voltage Offset Correction: v_off_ini = -0.000004817 V, v_off_fin = -0.000038978 V 18:48:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003744200 Vs 18:48:34 Voltage Offset Correction: v_off_ini = -0.000000980 V, v_off_fin = 0.000024890 V 18:48:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003735864 Vs 18:48:35 Magnet Current for Main , Imag = 90.0018 A Vtrans = 0.900254 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:48:41 Voltage Offset Correction: v_off_ini = -0.000001395 V, v_off_fin = -0.000032837 V 18:48:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003738875 Vs 18:48:48 Voltage Offset Correction: v_off_ini = -0.000001006 V, v_off_fin = -0.000067250 V 18:48:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003687932 Vs 18:48:49 Magnet Current for Main , Imag = 90.0018 A Vtrans = 0.900254 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:48:55 Voltage Offset Correction: v_off_ini = -0.000000550 V, v_off_fin = -0.000047708 V 18:48:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003746287 Vs 18:49:02 Voltage Offset Correction: v_off_ini = -0.000001325 V, v_off_fin = -0.000022553 V 18:49:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003711477 Vs 18:49:02 Magnet Current for Main , Imag = 90.0016 A Vtrans = 0.900252 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:49:09 Voltage Offset Correction: v_off_ini = -0.000000802 V, v_off_fin = -0.000012328 V 18:49:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003727651 Vs 18:49:15 Voltage Offset Correction: v_off_ini = -0.000001485 V, v_off_fin = 0.000055297 V 18:49:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003750961 Vs 18:49:16 Magnet Current for Main , Imag = 90.0015 A Vtrans = 0.900251 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:49:23 Voltage Offset Correction: v_off_ini = -0.000000590 V, v_off_fin = -0.000002616 V 18:49:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003723117 Vs 18:49:29 Voltage Offset Correction: v_off_ini = -0.000000713 V, v_off_fin = -0.000066985 V 18:49:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003688009 Vs 18:49:30 Magnet Current for Main , Imag = 90.0017 A Vtrans = 0.900253 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:49:37 Voltage Offset Correction: v_off_ini = -0.000001459 V, v_off_fin = 0.000000703 V 18:49:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003721840 Vs 18:49:43 Voltage Offset Correction: v_off_ini = -0.000001174 V, v_off_fin = -0.000077753 V 18:49:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003682468 Vs 18:49:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003721557 +- 0.000015323 Vs 18:49:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003721557 +- 0.000015323 Vs BL = 0.37215569 +- 0.00153231 Tm 18:49:47 Position moved: 0.000000 m 18:49:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.37216 0.00153 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.37216 0.00153 0.37216 0.00000 18:49:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.37216 0.00153 SL = 0.3721557 +- 0.0015323 Tm^2/m^n 18:49:47 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3721557 +- 0.0015323 Tm^2/m^n 18:49:50 Position moved: 0.000000 m 18:49:50 Magnet system Main current ramping to 105.0000 A... 18:50:05 Magnet Current for Main , Imag = 105.0298 A Vtrans = 1.050534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:50:06 MAIN Voltage Measurement, V = 7.449563 V 18:50:06 Temperature Measurement, Probe Number = 0, T = 28.990000 C 18:50:07 Temperature Measurement, Probe Number = 1, T = 29.271000 C 18:50:07 Temperature Measurement, Probe Number = 2, T = 26.448000 C 18:50:07 Magnet Test Parameter Measurements P0 = Main , Value = 105.03 P1 = MAIN, Value = 7.45 P2 = Steel, Value = 28.99 P3 = Coil, Value = 29.27 P4 = Ambient Temp, Value = 26.45 18:50:07 Magnetic Field Measurement Measuring the magnet strength... 18:50:07 Integrated Voltage Measurement... 18:50:08 Magnet Current for Main , Imag = 105.0300 A Vtrans = 1.050536 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:50:16 Voltage Offset Correction: v_off_ini = -0.000005442 V, v_off_fin = -0.000038753 V 18:50:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004363626 Vs 18:50:22 Voltage Offset Correction: v_off_ini = -0.000000692 V, v_off_fin = 0.000000329 V 18:50:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004341877 Vs 18:50:23 Magnet Current for Main , Imag = 105.0298 A Vtrans = 1.050534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:50:30 Voltage Offset Correction: v_off_ini = -0.000001547 V, v_off_fin = 0.000039398 V 18:50:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004320938 Vs 18:50:36 Voltage Offset Correction: v_off_ini = -0.000001176 V, v_off_fin = 0.000010120 V 18:50:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004347355 Vs 18:50:37 Magnet Current for Main , Imag = 105.0300 A Vtrans = 1.050536 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:50:43 Voltage Offset Correction: v_off_ini = -0.000001360 V, v_off_fin = -0.000008995 V 18:50:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004345591 Vs 18:50:50 Voltage Offset Correction: v_off_ini = -0.000000744 V, v_off_fin = 0.000066918 V 18:50:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004377260 Vs 18:50:51 Magnet Current for Main , Imag = 105.0300 A Vtrans = 1.050535 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:50:57 Voltage Offset Correction: v_off_ini = -0.000001240 V, v_off_fin = -0.000015145 V 18:50:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004349572 Vs 18:51:04 Voltage Offset Correction: v_off_ini = -0.000001299 V, v_off_fin = 0.000023736 V 18:51:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004354068 Vs 18:51:05 Magnet Current for Main , Imag = 105.0298 A Vtrans = 1.050534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:51:11 Voltage Offset Correction: v_off_ini = -0.000001671 V, v_off_fin = 0.000043938 V 18:51:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004318502 Vs 18:51:18 Voltage Offset Correction: v_off_ini = -0.000001839 V, v_off_fin = -0.000016069 V 18:51:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004334485 Vs 18:51:18 Magnet Current for Main , Imag = 105.0297 A Vtrans = 1.050533 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:51:25 Voltage Offset Correction: v_off_ini = -0.000001651 V, v_off_fin = -0.000020931 V 18:51:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004352017 Vs 18:51:32 Voltage Offset Correction: v_off_ini = -0.000000929 V, v_off_fin = 0.000075504 V 18:51:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004382370 Vs 18:51:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004348972 +- 0.000014344 Vs 18:51:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004348972 +- 0.000014344 Vs BL = 0.43489717 +- 0.00143444 Tm 18:51:35 Position moved: 0.000000 m 18:51:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.43490 0.00143 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.43490 0.00143 0.43490 0.00000 18:51:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.43490 0.00143 SL = 0.4348972 +- 0.0014344 Tm^2/m^n 18:51:35 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4348972 +- 0.0014344 Tm^2/m^n 18:51:38 Position moved: 0.000000 m 18:51:38 Magnet system Main current ramping to 120.0000 A... 18:51:53 Magnet Current for Main , Imag = 120.0457 A Vtrans = 1.200693 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:51:54 MAIN Voltage Measurement, V = 8.522299 V 18:51:54 Temperature Measurement, Probe Number = 0, T = 28.977000 C 18:51:55 Temperature Measurement, Probe Number = 1, T = 29.383000 C 18:51:56 Temperature Measurement, Probe Number = 2, T = 26.345000 C 18:51:56 Magnet Test Parameter Measurements P0 = Main , Value = 120.05 P1 = MAIN, Value = 8.52 P2 = Steel, Value = 28.98 P3 = Coil, Value = 29.38 P4 = Ambient Temp, Value = 26.34 18:51:56 Magnetic Field Measurement Measuring the magnet strength... 18:51:56 Integrated Voltage Measurement... 18:51:56 Magnet Current for Main , Imag = 120.0461 A Vtrans = 1.200697 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:52:04 Voltage Offset Correction: v_off_ini = -0.000000305 V, v_off_fin = 0.000017038 V 18:52:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004950358 Vs 18:52:11 Voltage Offset Correction: v_off_ini = -0.000000483 V, v_off_fin = -0.000092098 V 18:52:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004914322 Vs 18:52:11 Magnet Current for Main , Imag = 120.0457 A Vtrans = 1.200693 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:52:18 Voltage Offset Correction: v_off_ini = -0.000001647 V, v_off_fin = 0.000045097 V 18:52:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004936869 Vs 18:52:25 Voltage Offset Correction: v_off_ini = -0.000000963 V, v_off_fin = -0.000056965 V 18:52:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004931094 Vs 18:52:25 Magnet Current for Main , Imag = 120.0459 A Vtrans = 1.200695 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:52:32 Voltage Offset Correction: v_off_ini = -0.000001438 V, v_off_fin = -0.000034527 V 18:52:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004978090 Vs 18:52:38 Voltage Offset Correction: v_off_ini = -0.000001615 V, v_off_fin = -0.000053117 V 18:52:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004933001 Vs 18:52:39 Magnet Current for Main , Imag = 120.0461 A Vtrans = 1.200697 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:52:46 Voltage Offset Correction: v_off_ini = -0.000001060 V, v_off_fin = 0.000056330 V 18:52:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004930526 Vs 18:52:52 Voltage Offset Correction: v_off_ini = -0.000001208 V, v_off_fin = -0.000011488 V 18:52:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004955856 Vs 18:52:53 Magnet Current for Main , Imag = 120.0459 A Vtrans = 1.200695 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:53:00 Voltage Offset Correction: v_off_ini = -0.000001170 V, v_off_fin = 0.000000246 V 18:53:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004959656 Vs 18:53:06 Voltage Offset Correction: v_off_ini = -0.000001730 V, v_off_fin = -0.000052348 V 18:53:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004933262 Vs 18:53:07 Magnet Current for Main , Imag = 120.0459 A Vtrans = 1.200695 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:53:13 Voltage Offset Correction: v_off_ini = -0.000001834 V, v_off_fin = 0.000045497 V 18:53:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004936737 Vs 18:53:20 Voltage Offset Correction: v_off_ini = -0.000001611 V, v_off_fin = 0.000036373 V 18:53:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004979509 Vs 18:53:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004944940 +- 0.000009751 Vs 18:53:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004944940 +- 0.000009751 Vs BL = 0.49449400 +- 0.00097508 Tm 18:53:24 Position moved: 0.000000 m 18:53:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.49449 0.00098 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.49449 0.00098 0.49449 0.00000 18:53:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.49449 0.00098 SL = 0.4944940 +- 0.0009751 Tm^2/m^n 18:53:24 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4944940 +- 0.0009751 Tm^2/m^n 18:53:26 Position moved: 0.000000 m 18:53:26 Magnet system Main current ramping to 135.0000 A... 18:53:41 Magnet Current for Main , Imag = 134.9986 A Vtrans = 1.350222 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:53:42 MAIN Voltage Measurement, V = 9.593608 V 18:53:43 Temperature Measurement, Probe Number = 0, T = 28.952000 C 18:53:43 Temperature Measurement, Probe Number = 1, T = 29.542000 C 18:53:44 Temperature Measurement, Probe Number = 2, T = 26.320000 C 18:53:44 Magnet Test Parameter Measurements P0 = Main , Value = 135.00 P1 = MAIN, Value = 9.59 P2 = Steel, Value = 28.95 P3 = Coil, Value = 29.54 P4 = Ambient Temp, Value = 26.32 18:53:44 Magnetic Field Measurement Measuring the magnet strength... 18:53:44 Integrated Voltage Measurement... 18:53:45 Magnet Current for Main , Imag = 134.9990 A Vtrans = 1.350225 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:53:52 Voltage Offset Correction: v_off_ini = 0.000002175 V, v_off_fin = -0.000066170 V 18:53:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005609787 Vs 18:53:59 Voltage Offset Correction: v_off_ini = -0.000001773 V, v_off_fin = -0.000086777 V 18:53:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005533357 Vs 18:54:00 Magnet Current for Main , Imag = 134.9987 A Vtrans = 1.350223 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:54:06 Voltage Offset Correction: v_off_ini = -0.000000343 V, v_off_fin = 0.000015589 V 18:54:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005567584 Vs 18:54:13 Voltage Offset Correction: v_off_ini = -0.000001258 V, v_off_fin = 0.000102494 V 18:54:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005632059 Vs 18:54:13 Magnet Current for Main , Imag = 134.9987 A Vtrans = 1.350223 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:54:20 Voltage Offset Correction: v_off_ini = -0.000001827 V, v_off_fin = 0.000006456 V 18:54:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005572737 Vs 18:54:27 Voltage Offset Correction: v_off_ini = -0.000000757 V, v_off_fin = -0.000003112 V 18:54:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005575396 Vs 18:54:27 Magnet Current for Main , Imag = 134.9987 A Vtrans = 1.350223 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:54:34 Voltage Offset Correction: v_off_ini = -0.000000587 V, v_off_fin = 0.000022984 V 18:54:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005565201 Vs 18:54:40 Voltage Offset Correction: v_off_ini = -0.000000734 V, v_off_fin = -0.000102713 V 18:54:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005524005 Vs 18:54:41 Magnet Current for Main , Imag = 134.9986 A Vtrans = 1.350222 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:54:48 Voltage Offset Correction: v_off_ini = -0.000001304 V, v_off_fin = -0.000034756 V 18:54:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005595544 Vs 18:54:54 Voltage Offset Correction: v_off_ini = -0.000000983 V, v_off_fin = -0.000036576 V 18:54:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005559973 Vs 18:54:55 Magnet Current for Main , Imag = 134.9985 A Vtrans = 1.350220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:55:01 Voltage Offset Correction: v_off_ini = -0.000000261 V, v_off_fin = 0.000015907 V 18:55:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005567051 Vs 18:55:08 Voltage Offset Correction: v_off_ini = -0.000000779 V, v_off_fin = 0.000098230 V 18:55:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005629569 Vs 18:55:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005577688 +- 0.000018531 Vs 18:55:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.005577688 +- 0.000018531 Vs BL = 0.55776885 +- 0.00185306 Tm 18:55:12 Position moved: 0.000000 m 18:55:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.55777 0.00185 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.55777 0.00185 0.55777 0.00000 18:55:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.55777 0.00185 SL = 0.5577688 +- 0.0018531 Tm^2/m^n 18:55:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5577688 +- 0.0018531 Tm^2/m^n 18:55:15 Position moved: 0.000000 m 18:55:15 Magnet system Main current ramping to 150.0000 A... 18:55:30 Magnet Current for Main , Imag = 150.0221 A Vtrans = 1.500457 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:55:30 MAIN Voltage Measurement, V = 10.673674 V 18:55:31 Temperature Measurement, Probe Number = 0, T = 28.947000 C 18:55:32 Temperature Measurement, Probe Number = 1, T = 29.727000 C 18:55:32 Temperature Measurement, Probe Number = 2, T = 26.309000 C 18:55:32 Magnet Test Parameter Measurements P0 = Main , Value = 150.02 P1 = MAIN, Value = 10.67 P2 = Steel, Value = 28.95 P3 = Coil, Value = 29.73 P4 = Ambient Temp, Value = 26.31 18:55:32 Magnetic Field Measurement Measuring the magnet strength... 18:55:32 Integrated Voltage Measurement... 18:55:33 Magnet Current for Main , Imag = 150.0223 A Vtrans = 1.500458 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:55:41 Voltage Offset Correction: v_off_ini = 0.000004459 V, v_off_fin = -0.000067689 V 18:55:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006228374 Vs 18:55:47 Voltage Offset Correction: v_off_ini = -0.000002210 V, v_off_fin = -0.000118813 V 18:55:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006133956 Vs 18:55:48 Magnet Current for Main , Imag = 150.0223 A Vtrans = 1.500458 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:55:55 Voltage Offset Correction: v_off_ini = -0.000000909 V, v_off_fin = -0.000058680 V 18:55:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006226246 Vs 18:56:01 Voltage Offset Correction: v_off_ini = -0.000001605 V, v_off_fin = -0.000125152 V 18:56:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006131962 Vs 18:56:02 Magnet Current for Main , Imag = 150.0219 A Vtrans = 1.500455 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:56:08 Voltage Offset Correction: v_off_ini = -0.000002320 V, v_off_fin = -0.000035705 V 18:56:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006215256 Vs 18:56:15 Voltage Offset Correction: v_off_ini = -0.000001015 V, v_off_fin = -0.000110414 V 18:56:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006138695 Vs 18:56:16 Magnet Current for Main , Imag = 150.0220 A Vtrans = 1.500456 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:56:22 Voltage Offset Correction: v_off_ini = -0.000001357 V, v_off_fin = -0.000003399 V 18:56:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006197079 Vs 18:56:29 Voltage Offset Correction: v_off_ini = -0.000000802 V, v_off_fin = -0.000041573 V 18:56:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006174616 Vs 18:56:29 Magnet Current for Main , Imag = 150.0214 A Vtrans = 1.500449 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:56:36 Voltage Offset Correction: v_off_ini = -0.000001138 V, v_off_fin = 0.000027068 V 18:56:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006180783 Vs 18:56:43 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000069696 V 18:56:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006159424 Vs 18:56:43 Magnet Current for Main , Imag = 150.0220 A Vtrans = 1.500456 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:56:50 Voltage Offset Correction: v_off_ini = -0.000000877 V, v_off_fin = -0.000019973 V 18:56:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006205310 Vs 18:56:56 Voltage Offset Correction: v_off_ini = -0.000001381 V, v_off_fin = 0.000073919 V 18:56:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006236628 Vs 18:56:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006185694 +- 0.000016469 Vs 18:56:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006185694 +- 0.000016469 Vs BL = 0.61856943 +- 0.00164690 Tm 18:57:00 Position moved: 0.000000 m 18:57:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.61857 0.00165 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.61857 0.00165 0.61857 0.00000 18:57:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.61857 0.00165 SL = 0.6185694 +- 0.0016469 Tm^2/m^n 18:57:00 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6185694 +- 0.0016469 Tm^2/m^n 18:57:03 Position moved: 0.000000 m 18:57:03 Magnet system Main current ramping to 165.0000 A... 18:57:18 Magnet Current for Main , Imag = 165.0474 A Vtrans = 1.650710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:57:19 MAIN Voltage Measurement, V = 11.758128 V 18:57:19 Temperature Measurement, Probe Number = 0, T = 28.950000 C 18:57:20 Temperature Measurement, Probe Number = 1, T = 29.906000 C 18:57:21 Temperature Measurement, Probe Number = 2, T = 26.256000 C 18:57:21 Magnet Test Parameter Measurements P0 = Main , Value = 165.05 P1 = MAIN, Value = 11.76 P2 = Steel, Value = 28.95 P3 = Coil, Value = 29.91 P4 = Ambient Temp, Value = 26.26 18:57:21 Magnetic Field Measurement Measuring the magnet strength... 18:57:21 Integrated Voltage Measurement... 18:57:21 Magnet Current for Main , Imag = 165.0480 A Vtrans = 1.650716 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:57:29 Voltage Offset Correction: v_off_ini = -0.000003628 V, v_off_fin = -0.000037820 V 18:57:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006834724 Vs 18:57:36 Voltage Offset Correction: v_off_ini = -0.000000355 V, v_off_fin = 0.000101429 V 18:57:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006868248 Vs 18:57:36 Magnet Current for Main , Imag = 165.0478 A Vtrans = 1.650713 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:57:43 Voltage Offset Correction: v_off_ini = -0.000001519 V, v_off_fin = -0.000062758 V 18:57:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006847304 Vs 18:57:49 Voltage Offset Correction: v_off_ini = -0.000001916 V, v_off_fin = 0.000095533 V 18:57:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006864214 Vs 18:57:50 Magnet Current for Main , Imag = 165.0478 A Vtrans = 1.650713 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:57:57 Voltage Offset Correction: v_off_ini = -0.000001272 V, v_off_fin = 0.000073570 V 18:57:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006776070 Vs 18:58:03 Voltage Offset Correction: v_off_ini = -0.000001742 V, v_off_fin = -0.000018674 V 18:58:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006804891 Vs 18:58:04 Magnet Current for Main , Imag = 165.0479 A Vtrans = 1.650715 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:58:11 Voltage Offset Correction: v_off_ini = -0.000001257 V, v_off_fin = 0.000071691 V 18:58:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006776383 Vs 18:58:17 Voltage Offset Correction: v_off_ini = -0.000000717 V, v_off_fin = 0.000132894 V 18:58:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006885960 Vs 18:58:18 Magnet Current for Main , Imag = 165.0475 A Vtrans = 1.650711 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:58:24 Voltage Offset Correction: v_off_ini = -0.000000508 V, v_off_fin = -0.000039116 V 18:58:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006834199 Vs 18:58:31 Voltage Offset Correction: v_off_ini = -0.000002293 V, v_off_fin = -0.000001693 V 18:58:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006815307 Vs 18:58:32 Magnet Current for Main , Imag = 165.0476 A Vtrans = 1.650712 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:58:38 Voltage Offset Correction: v_off_ini = -0.000001999 V, v_off_fin = -0.000030266 V 18:58:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006829926 Vs 18:58:45 Voltage Offset Correction: v_off_ini = -0.000001528 V, v_off_fin = -0.000009371 V 18:58:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006810692 Vs 18:58:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006828993 +- 0.000021617 Vs 18:58:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006828993 +- 0.000021617 Vs BL = 0.68289931 +- 0.00216168 Tm 18:58:49 Position moved: 0.000000 m 18:58:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.68290 0.00216 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.68290 0.00216 0.68290 0.00000 18:58:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.68290 0.00216 SL = 0.6828993 +- 0.0021617 Tm^2/m^n 18:58:49 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6828993 +- 0.0021617 Tm^2/m^n 18:58:51 Position moved: 0.000000 m 18:58:51 Magnet system Main current ramping to 170.0000 A... 18:59:04 Magnet Current for Main , Imag = 170.0848 A Vtrans = 1.701084 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:59:04 MAIN Voltage Measurement, V = 12.132073 V 18:59:05 Temperature Measurement, Probe Number = 0, T = 28.945000 C 18:59:06 Temperature Measurement, Probe Number = 1, T = 30.115000 C 18:59:06 Temperature Measurement, Probe Number = 2, T = 26.270000 C 18:59:06 Magnet Test Parameter Measurements P0 = Main , Value = 170.08 P1 = MAIN, Value = 12.13 P2 = Steel, Value = 28.95 P3 = Coil, Value = 30.11 P4 = Ambient Temp, Value = 26.27 18:59:06 Magnetic Field Measurement Measuring the magnet strength... 18:59:06 Integrated Voltage Measurement... 18:59:07 Magnet Current for Main , Imag = 170.0852 A Vtrans = 1.701088 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:59:15 Voltage Offset Correction: v_off_ini = -0.000002339 V, v_off_fin = -0.000002389 V 18:59:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007024252 Vs 18:59:21 Voltage Offset Correction: v_off_ini = -0.000001520 V, v_off_fin = -0.000019858 V 18:59:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007012254 Vs 18:59:22 Magnet Current for Main , Imag = 170.0849 A Vtrans = 1.701085 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:59:29 Voltage Offset Correction: v_off_ini = -0.000000695 V, v_off_fin = 0.000080002 V 18:59:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006978775 Vs 18:59:35 Voltage Offset Correction: v_off_ini = -0.000001301 V, v_off_fin = -0.000022277 V 18:59:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007009748 Vs 18:59:36 Magnet Current for Main , Imag = 170.0851 A Vtrans = 1.701086 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:59:42 Voltage Offset Correction: v_off_ini = -0.000001615 V, v_off_fin = 0.000067214 V 18:59:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006986383 Vs 18:59:49 Voltage Offset Correction: v_off_ini = -0.000001109 V, v_off_fin = -0.000020724 V 18:59:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007012301 Vs 18:59:50 Magnet Current for Main , Imag = 170.0848 A Vtrans = 1.701084 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 18:59:56 Voltage Offset Correction: v_off_ini = -0.000002197 V, v_off_fin = -0.000016123 V 18:59:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007029451 Vs 19:00:03 Voltage Offset Correction: v_off_ini = -0.000001216 V, v_off_fin = -0.000092152 V 19:00:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006974625 Vs 19:00:03 Magnet Current for Main , Imag = 170.0849 A Vtrans = 1.701085 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:00:10 Voltage Offset Correction: v_off_ini = -0.000001955 V, v_off_fin = 0.000084088 V 19:00:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006977310 Vs 19:00:16 Voltage Offset Correction: v_off_ini = -0.000001731 V, v_off_fin = 0.000056715 V 19:00:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007052942 Vs 19:00:17 Magnet Current for Main , Imag = 170.0851 A Vtrans = 1.701086 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:00:23 Voltage Offset Correction: v_off_ini = -0.000000492 V, v_off_fin = -0.000044669 V 19:00:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007044580 Vs 19:00:30 Voltage Offset Correction: v_off_ini = -0.000001793 V, v_off_fin = -0.000056108 V 19:00:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006993273 Vs 19:00:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007007991 +- 0.000009786 Vs 19:00:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007007991 +- 0.000009786 Vs BL = 0.70079911 +- 0.00097855 Tm 19:00:34 Position moved: 0.000000 m 19:00:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.70080 0.00098 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.70080 0.00098 0.70080 0.00000 19:00:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.70080 0.00098 SL = 0.7007991 +- 0.0009786 Tm^2/m^n 19:00:34 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7007991 +- 0.0009786 Tm^2/m^n 19:00:37 Position moved: 0.000000 m 19:00:37 Magnet system Main current ramping to 165.0000 A... 19:00:49 Magnet Current for Main , Imag = 165.0476 A Vtrans = 1.650712 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:00:49 MAIN Voltage Measurement, V = 11.778735 V 19:00:50 Temperature Measurement, Probe Number = 0, T = 28.945000 C 19:00:51 Temperature Measurement, Probe Number = 1, T = 30.244000 C 19:00:51 Temperature Measurement, Probe Number = 2, T = 26.311000 C 19:00:51 Magnet Test Parameter Measurements P0 = Main , Value = 165.05 P1 = MAIN, Value = 11.78 P2 = Steel, Value = 28.95 P3 = Coil, Value = 30.24 P4 = Ambient Temp, Value = 26.31 19:00:51 Magnetic Field Measurement Measuring the magnet strength... 19:00:51 Integrated Voltage Measurement... 19:00:52 Magnet Current for Main , Imag = 165.0478 A Vtrans = 1.650713 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:01:00 Voltage Offset Correction: v_off_ini = -0.000002905 V, v_off_fin = -0.000085128 V 19:01:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006864307 Vs 19:01:06 Voltage Offset Correction: v_off_ini = -0.000002047 V, v_off_fin = -0.000133183 V 19:01:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006750126 Vs 19:01:07 Magnet Current for Main , Imag = 165.0478 A Vtrans = 1.650713 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:01:14 Voltage Offset Correction: v_off_ini = -0.000001937 V, v_off_fin = -0.000047348 V 19:01:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006843512 Vs 19:01:20 Voltage Offset Correction: v_off_ini = -0.000001443 V, v_off_fin = 0.000122838 V 19:01:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006884349 Vs 19:01:21 Magnet Current for Main , Imag = 165.0479 A Vtrans = 1.650715 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:01:28 Voltage Offset Correction: v_off_ini = -0.000002132 V, v_off_fin = -0.000073259 V 19:01:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006857263 Vs 19:01:34 Voltage Offset Correction: v_off_ini = -0.000002153 V, v_off_fin = 0.000116976 V 19:01:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006880090 Vs 19:01:35 Magnet Current for Main , Imag = 165.0476 A Vtrans = 1.650712 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:01:41 Voltage Offset Correction: v_off_ini = -0.000001167 V, v_off_fin = 0.000051771 V 19:01:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006790865 Vs 19:01:48 Voltage Offset Correction: v_off_ini = -0.000000558 V, v_off_fin = 0.000043713 V 19:01:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006842587 Vs 19:01:49 Magnet Current for Main , Imag = 165.0479 A Vtrans = 1.650715 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:01:55 Voltage Offset Correction: v_off_ini = -0.000001058 V, v_off_fin = -0.000085866 V 19:01:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006864398 Vs 19:02:02 Voltage Offset Correction: v_off_ini = -0.000000209 V, v_off_fin = -0.000067584 V 19:02:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006785728 Vs 19:02:03 Magnet Current for Main , Imag = 165.0478 A Vtrans = 1.650713 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:02:09 Voltage Offset Correction: v_off_ini = -0.000001053 V, v_off_fin = -0.000022489 V 19:02:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006830836 Vs 19:02:15 Voltage Offset Correction: v_off_ini = -0.000001458 V, v_off_fin = -0.000121372 V 19:02:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006755789 Vs 19:02:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006829154 +- 0.000028013 Vs 19:02:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006829154 +- 0.000028013 Vs BL = 0.68291542 +- 0.00280133 Tm 19:02:19 Position moved: 0.000000 m 19:02:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.68292 0.00280 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.68292 0.00280 0.68292 0.00000 19:02:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.68292 0.00280 SL = 0.6829154 +- 0.0028013 Tm^2/m^n 19:02:19 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6829154 +- 0.0028013 Tm^2/m^n 19:02:22 Position moved: 0.000000 m 19:02:22 Magnet system Main current ramping to 150.0000 A... 19:02:37 Magnet Current for Main , Imag = 150.0223 A Vtrans = 1.500458 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:02:38 MAIN Voltage Measurement, V = 10.701032 V 19:02:38 Temperature Measurement, Probe Number = 0, T = 28.960000 C 19:02:39 Temperature Measurement, Probe Number = 1, T = 30.224000 C 19:02:40 Temperature Measurement, Probe Number = 2, T = 26.313000 C 19:02:40 Magnet Test Parameter Measurements P0 = Main , Value = 150.02 P1 = MAIN, Value = 10.70 P2 = Steel, Value = 28.96 P3 = Coil, Value = 30.22 P4 = Ambient Temp, Value = 26.31 19:02:40 Magnetic Field Measurement Measuring the magnet strength... 19:02:40 Integrated Voltage Measurement... 19:02:40 Magnet Current for Main , Imag = 150.0229 A Vtrans = 1.500465 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:02:48 Voltage Offset Correction: v_off_ini = 0.000003119 V, v_off_fin = 0.000044959 V 19:02:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006184599 Vs 19:02:55 Voltage Offset Correction: v_off_ini = -0.000001984 V, v_off_fin = 0.000027484 V 19:02:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006224738 Vs 19:02:55 Magnet Current for Main , Imag = 150.0223 A Vtrans = 1.500458 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:03:02 Voltage Offset Correction: v_off_ini = -0.000001213 V, v_off_fin = 0.000020840 V 19:03:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006198056 Vs 19:03:08 Voltage Offset Correction: v_off_ini = -0.000000353 V, v_off_fin = -0.000094581 V 19:03:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006162300 Vs 19:03:09 Magnet Current for Main , Imag = 150.0227 A Vtrans = 1.500462 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:03:16 Voltage Offset Correction: v_off_ini = -0.000000545 V, v_off_fin = -0.000084628 V 19:03:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006253571 Vs 19:03:22 Voltage Offset Correction: v_off_ini = -0.000002187 V, v_off_fin = -0.000019757 V 19:03:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006200529 Vs 19:03:23 Magnet Current for Main , Imag = 150.0225 A Vtrans = 1.500461 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:03:30 Voltage Offset Correction: v_off_ini = -0.000001378 V, v_off_fin = -0.000007393 V 19:03:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006213146 Vs 19:03:36 Voltage Offset Correction: v_off_ini = -0.000002036 V, v_off_fin = -0.000102667 V 19:03:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006156187 Vs 19:03:37 Magnet Current for Main , Imag = 150.0229 A Vtrans = 1.500465 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:03:43 Voltage Offset Correction: v_off_ini = -0.000000801 V, v_off_fin = 0.000064914 V 19:03:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006175754 Vs 19:03:50 Voltage Offset Correction: v_off_ini = -0.000001681 V, v_off_fin = 0.000103969 V 19:03:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006264926 Vs 19:03:50 Magnet Current for Main , Imag = 150.0225 A Vtrans = 1.500461 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:03:57 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000066727 V 19:03:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006244982 Vs 19:04:03 Voltage Offset Correction: v_off_ini = -0.000001814 V, v_off_fin = -0.000032434 V 19:04:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006194820 Vs 19:04:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006206134 +- 0.000018099 Vs 19:04:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006206134 +- 0.000018099 Vs BL = 0.62061340 +- 0.00180994 Tm 19:04:07 Position moved: 0.000000 m 19:04:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.62061 0.00181 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.62061 0.00181 0.62061 0.00000 19:04:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.62061 0.00181 SL = 0.6206134 +- 0.0018099 Tm^2/m^n 19:04:07 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6206134 +- 0.0018099 Tm^2/m^n 19:04:10 Position moved: 0.000000 m 19:04:10 Magnet system Main current ramping to 135.0000 A... 19:04:25 Magnet Current for Main , Imag = 134.9988 A Vtrans = 1.350224 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:04:26 MAIN Voltage Measurement, V = 9.617434 V 19:04:27 Temperature Measurement, Probe Number = 0, T = 28.976000 C 19:04:27 Temperature Measurement, Probe Number = 1, T = 30.056000 C 19:04:28 Temperature Measurement, Probe Number = 2, T = 26.154000 C 19:04:28 Magnet Test Parameter Measurements P0 = Main , Value = 135.00 P1 = MAIN, Value = 9.62 P2 = Steel, Value = 28.98 P3 = Coil, Value = 30.06 P4 = Ambient Temp, Value = 26.15 19:04:28 Magnetic Field Measurement Measuring the magnet strength... 19:04:28 Integrated Voltage Measurement... 19:04:29 Magnet Current for Main , Imag = 134.9992 A Vtrans = 1.350228 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:04:36 Voltage Offset Correction: v_off_ini = 0.000004861 V, v_off_fin = -0.000056444 V 19:04:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005623953 Vs 19:04:43 Voltage Offset Correction: v_off_ini = -0.000000381 V, v_off_fin = 0.000108449 V 19:04:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005655744 Vs 19:04:43 Magnet Current for Main , Imag = 134.9994 A Vtrans = 1.350229 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:04:50 Voltage Offset Correction: v_off_ini = -0.000001203 V, v_off_fin = -0.000073723 V 19:04:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005636257 Vs 19:04:57 Voltage Offset Correction: v_off_ini = -0.000001352 V, v_off_fin = -0.000006969 V 19:04:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005595949 Vs 19:04:57 Magnet Current for Main , Imag = 134.9985 A Vtrans = 1.350220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:05:04 Voltage Offset Correction: v_off_ini = -0.000001640 V, v_off_fin = -0.000050002 V 19:05:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005624330 Vs 19:05:10 Voltage Offset Correction: v_off_ini = -0.000001952 V, v_off_fin = 0.000102981 V 19:05:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005652242 Vs 19:05:11 Magnet Current for Main , Imag = 134.9987 A Vtrans = 1.350223 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:05:17 Voltage Offset Correction: v_off_ini = -0.000001673 V, v_off_fin = 0.000057846 V 19:05:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005566830 Vs 19:05:24 Voltage Offset Correction: v_off_ini = -0.000001981 V, v_off_fin = 0.000107184 V 19:05:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005654052 Vs 19:05:25 Magnet Current for Main , Imag = 134.9990 A Vtrans = 1.350225 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:05:31 Voltage Offset Correction: v_off_ini = -0.000001461 V, v_off_fin = -0.000062365 V 19:05:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005630149 Vs 19:05:38 Voltage Offset Correction: v_off_ini = -0.000000714 V, v_off_fin = -0.000076793 V 19:05:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005559937 Vs 19:05:39 Magnet Current for Main , Imag = 134.9988 A Vtrans = 1.350224 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:05:45 Voltage Offset Correction: v_off_ini = -0.000000499 V, v_off_fin = 0.000019991 V 19:05:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005585771 Vs 19:05:52 Voltage Offset Correction: v_off_ini = -0.000000191 V, v_off_fin = 0.000073824 V 19:05:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005636776 Vs 19:05:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005618499 +- 0.000015918 Vs 19:05:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.005618499 +- 0.000015918 Vs BL = 0.56184991 +- 0.00159185 Tm 19:05:56 Position moved: 0.000000 m 19:05:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.56185 0.00159 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.56185 0.00159 0.56185 0.00000 19:05:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.56185 0.00159 SL = 0.5618499 +- 0.0015918 Tm^2/m^n 19:05:56 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5618499 +- 0.0015918 Tm^2/m^n 19:05:59 Position moved: 0.000000 m 19:05:59 Magnet system Main current ramping to 120.0000 A... 19:06:14 Magnet Current for Main , Imag = 120.0462 A Vtrans = 1.200698 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:06:14 MAIN Voltage Measurement, V = 8.541149 V 19:06:15 Temperature Measurement, Probe Number = 0, T = 28.987000 C 19:06:15 Temperature Measurement, Probe Number = 1, T = 29.858000 C 19:06:16 Temperature Measurement, Probe Number = 2, T = 26.177000 C 19:06:16 Magnet Test Parameter Measurements P0 = Main , Value = 120.05 P1 = MAIN, Value = 8.54 P2 = Steel, Value = 28.99 P3 = Coil, Value = 29.86 P4 = Ambient Temp, Value = 26.18 19:06:16 Magnetic Field Measurement Measuring the magnet strength... 19:06:16 Integrated Voltage Measurement... 19:06:17 Magnet Current for Main , Imag = 120.0465 A Vtrans = 1.200700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:06:25 Voltage Offset Correction: v_off_ini = 0.000002642 V, v_off_fin = 0.000000706 V 19:06:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004982356 Vs 19:06:31 Voltage Offset Correction: v_off_ini = -0.000001010 V, v_off_fin = -0.000040786 V 19:06:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004966025 Vs 19:06:32 Magnet Current for Main , Imag = 120.0461 A Vtrans = 1.200697 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:06:38 Voltage Offset Correction: v_off_ini = -0.000000726 V, v_off_fin = -0.000006466 V 19:06:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004988119 Vs 19:06:45 Voltage Offset Correction: v_off_ini = -0.000001667 V, v_off_fin = 0.000041916 V 19:06:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005009189 Vs 19:06:46 Magnet Current for Main , Imag = 120.0465 A Vtrans = 1.200700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:06:52 Voltage Offset Correction: v_off_ini = -0.000000682 V, v_off_fin = -0.000056110 V 19:06:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005014682 Vs 19:06:59 Voltage Offset Correction: v_off_ini = -0.000001476 V, v_off_fin = 0.000034613 V 19:06:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005003523 Vs 19:06:59 Magnet Current for Main , Imag = 120.0461 A Vtrans = 1.200697 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:07:06 Voltage Offset Correction: v_off_ini = -0.000000720 V, v_off_fin = -0.000002586 V 19:07:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004986335 Vs 19:07:13 Voltage Offset Correction: v_off_ini = -0.000001005 V, v_off_fin = 0.000016893 V 19:07:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004995039 Vs 19:07:13 Magnet Current for Main , Imag = 120.0457 A Vtrans = 1.200693 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:07:20 Voltage Offset Correction: v_off_ini = -0.000001234 V, v_off_fin = -0.000015155 V 19:07:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004993211 Vs 19:07:26 Voltage Offset Correction: v_off_ini = -0.000000515 V, v_off_fin = 0.000031022 V 19:07:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.005003884 Vs 19:07:27 Magnet Current for Main , Imag = 120.0461 A Vtrans = 1.200697 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:07:34 Voltage Offset Correction: v_off_ini = -0.000001028 V, v_off_fin = -0.000035979 V 19:07:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005004602 Vs 19:07:40 Voltage Offset Correction: v_off_ini = -0.000001359 V, v_off_fin = 0.000004789 V 19:07:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004987942 Vs 19:07:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004994576 +- 0.000010622 Vs 19:07:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004994576 +- 0.000010622 Vs BL = 0.49945756 +- 0.00106222 Tm 19:07:44 Position moved: 0.000000 m 19:07:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.49946 0.00106 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.49946 0.00106 0.49946 0.00000 19:07:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.49946 0.00106 SL = 0.4994576 +- 0.0010622 Tm^2/m^n 19:07:44 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4994576 +- 0.0010622 Tm^2/m^n 19:07:47 Position moved: 0.000000 m 19:07:47 Magnet system Main current ramping to 105.0000 A... 19:08:02 Magnet Current for Main , Imag = 105.0285 A Vtrans = 1.050520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:08:02 MAIN Voltage Measurement, V = 7.463682 V 19:08:03 Temperature Measurement, Probe Number = 0, T = 28.970000 C 19:08:04 Temperature Measurement, Probe Number = 1, T = 29.662000 C 19:08:04 Temperature Measurement, Probe Number = 2, T = 26.208000 C 19:08:04 Magnet Test Parameter Measurements P0 = Main , Value = 105.03 P1 = MAIN, Value = 7.46 P2 = Steel, Value = 28.97 P3 = Coil, Value = 29.66 P4 = Ambient Temp, Value = 26.21 19:08:04 Magnetic Field Measurement Measuring the magnet strength... 19:08:04 Integrated Voltage Measurement... 19:08:05 Magnet Current for Main , Imag = 105.0290 A Vtrans = 1.050526 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:08:12 Voltage Offset Correction: v_off_ini = -0.000005282 V, v_off_fin = 0.000039595 V 19:08:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004350586 Vs 19:08:19 Voltage Offset Correction: v_off_ini = -0.000001222 V, v_off_fin = 0.000018918 V 19:08:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004381058 Vs 19:08:20 Magnet Current for Main , Imag = 105.0287 A Vtrans = 1.050523 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:08:26 Voltage Offset Correction: v_off_ini = -0.000000808 V, v_off_fin = -0.000020643 V 19:08:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004380621 Vs 19:08:33 Voltage Offset Correction: v_off_ini = -0.000000610 V, v_off_fin = 0.000049192 V 19:08:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004396891 Vs 19:08:34 Magnet Current for Main , Imag = 105.0286 A Vtrans = 1.050522 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:08:40 Voltage Offset Correction: v_off_ini = -0.000000835 V, v_off_fin = -0.000051372 V 19:08:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004395972 Vs 19:08:47 Voltage Offset Correction: v_off_ini = -0.000000681 V, v_off_fin = 0.000076078 V 19:08:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004410268 Vs 19:08:47 Magnet Current for Main , Imag = 105.0286 A Vtrans = 1.050522 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:08:54 Voltage Offset Correction: v_off_ini = -0.000000657 V, v_off_fin = -0.000023740 V 19:08:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004381253 Vs 19:09:01 Voltage Offset Correction: v_off_ini = -0.000001812 V, v_off_fin = -0.000006315 V 19:09:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004366275 Vs 19:09:01 Magnet Current for Main , Imag = 105.0286 A Vtrans = 1.050522 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:09:08 Voltage Offset Correction: v_off_ini = -0.000001271 V, v_off_fin = 0.000025242 V 19:09:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004355042 Vs 19:09:15 Voltage Offset Correction: v_off_ini = -0.000001497 V, v_off_fin = 0.000050216 V 19:09:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004395590 Vs 19:09:15 Magnet Current for Main , Imag = 105.0285 A Vtrans = 1.050520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:09:22 Voltage Offset Correction: v_off_ini = -0.000001546 V, v_off_fin = 0.000042781 V 19:09:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004346528 Vs 19:09:28 Voltage Offset Correction: v_off_ini = -0.000001177 V, v_off_fin = -0.000067113 V 19:09:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004334486 Vs 19:09:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004374547 +- 0.000019384 Vs 19:09:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004374547 +- 0.000019384 Vs BL = 0.43745475 +- 0.00193838 Tm 19:09:32 Position moved: 0.000000 m 19:09:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.43745 0.00194 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.43745 0.00194 0.43745 0.00000 19:09:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.43745 0.00194 SL = 0.4374547 +- 0.0019384 Tm^2/m^n 19:09:32 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4374547 +- 0.0019384 Tm^2/m^n 19:09:35 Position moved: 0.000000 m 19:09:35 Magnet system Main current ramping to 90.0000 A... 19:09:50 Magnet Current for Main , Imag = 90.0022 A Vtrans = 0.900258 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:09:51 MAIN Voltage Measurement, V = 6.389053 V 19:09:51 Temperature Measurement, Probe Number = 0, T = 28.970000 C 19:09:52 Temperature Measurement, Probe Number = 1, T = 29.472000 C 19:09:53 Temperature Measurement, Probe Number = 2, T = 26.194000 C 19:09:53 Magnet Test Parameter Measurements P0 = Main , Value = 90.00 P1 = MAIN, Value = 6.39 P2 = Steel, Value = 28.97 P3 = Coil, Value = 29.47 P4 = Ambient Temp, Value = 26.19 19:09:53 Magnetic Field Measurement Measuring the magnet strength... 19:09:53 Integrated Voltage Measurement... 19:09:53 Magnet Current for Main , Imag = 90.0025 A Vtrans = 0.900261 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:10:01 Voltage Offset Correction: v_off_ini = -0.000001606 V, v_off_fin = 0.000018435 V 19:10:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003740739 Vs 19:10:08 Voltage Offset Correction: v_off_ini = -0.000001132 V, v_off_fin = 0.000033614 V 19:10:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003768636 Vs 19:10:08 Magnet Current for Main , Imag = 90.0024 A Vtrans = 0.900259 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:10:15 Voltage Offset Correction: v_off_ini = -0.000001062 V, v_off_fin = 0.000005887 V 19:10:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003746907 Vs 19:10:21 Voltage Offset Correction: v_off_ini = -0.000000653 V, v_off_fin = 0.000060577 V 19:10:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003784167 Vs 19:10:22 Magnet Current for Main , Imag = 90.0022 A Vtrans = 0.900258 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:10:29 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = 0.000045506 V 19:10:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003727044 Vs 19:10:35 Voltage Offset Correction: v_off_ini = -0.000000437 V, v_off_fin = 0.000047176 V 19:10:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003777252 Vs 19:10:36 Magnet Current for Main , Imag = 90.0022 A Vtrans = 0.900258 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:10:43 Voltage Offset Correction: v_off_ini = -0.000001511 V, v_off_fin = -0.000046709 V 19:10:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003775715 Vs 19:10:49 Voltage Offset Correction: v_off_ini = -0.000000741 V, v_off_fin = 0.000001088 V 19:10:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003752586 Vs 19:10:50 Magnet Current for Main , Imag = 90.0021 A Vtrans = 0.900257 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:10:56 Voltage Offset Correction: v_off_ini = -0.000001431 V, v_off_fin = 0.000047320 V 19:10:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003726244 Vs 19:11:03 Voltage Offset Correction: v_off_ini = -0.000001077 V, v_off_fin = -0.000033943 V 19:11:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003733449 Vs 19:11:04 Magnet Current for Main , Imag = 90.0022 A Vtrans = 0.900258 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:11:10 Voltage Offset Correction: v_off_ini = -0.000001023 V, v_off_fin = 0.000024970 V 19:11:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003737627 Vs 19:11:17 Voltage Offset Correction: v_off_ini = -0.000001161 V, v_off_fin = -0.000060579 V 19:11:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003720428 Vs 19:11:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003749233 +- 0.000014780 Vs 19:11:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003749233 +- 0.000014780 Vs BL = 0.37492328 +- 0.00147799 Tm 19:11:21 Position moved: 0.000000 m 19:11:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.37492 0.00148 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.37492 0.00148 0.37492 0.00000 19:11:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.37492 0.00148 SL = 0.3749233 +- 0.0014780 Tm^2/m^n 19:11:21 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3749233 +- 0.0014780 Tm^2/m^n 19:11:24 Position moved: 0.000000 m 19:11:24 Magnet system Main current ramping to 75.0000 A... 19:11:39 Magnet Current for Main , Imag = 74.9850 A Vtrans = 0.750086 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:11:39 MAIN Voltage Measurement, V = 5.318494 V 19:11:40 Temperature Measurement, Probe Number = 0, T = 28.920000 C 19:11:41 Temperature Measurement, Probe Number = 1, T = 29.330000 C 19:11:41 Temperature Measurement, Probe Number = 2, T = 26.235000 C 19:11:41 Magnet Test Parameter Measurements P0 = Main , Value = 74.99 P1 = MAIN, Value = 5.32 P2 = Steel, Value = 28.92 P3 = Coil, Value = 29.33 P4 = Ambient Temp, Value = 26.23 19:11:41 Magnetic Field Measurement Measuring the magnet strength... 19:11:41 Integrated Voltage Measurement... 19:11:42 Magnet Current for Main , Imag = 74.9852 A Vtrans = 0.750088 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:11:50 Voltage Offset Correction: v_off_ini = -0.000000037 V, v_off_fin = -0.000032271 V 19:11:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003147919 Vs 19:11:56 Voltage Offset Correction: v_off_ini = -0.000001697 V, v_off_fin = 0.000011942 V 19:11:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003139613 Vs 19:11:57 Magnet Current for Main , Imag = 74.9853 A Vtrans = 0.750089 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:12:03 Voltage Offset Correction: v_off_ini = -0.000001020 V, v_off_fin = 0.000022766 V 19:12:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003119153 Vs 19:12:10 Voltage Offset Correction: v_off_ini = -0.000000849 V, v_off_fin = -0.000004086 V 19:12:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003130901 Vs 19:12:11 Magnet Current for Main , Imag = 74.9850 A Vtrans = 0.750085 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:12:17 Voltage Offset Correction: v_off_ini = -0.000001209 V, v_off_fin = -0.000041840 V 19:12:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003153682 Vs 19:12:24 Voltage Offset Correction: v_off_ini = -0.000000724 V, v_off_fin = -0.000021430 V 19:12:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003122296 Vs 19:12:25 Magnet Current for Main , Imag = 74.9849 A Vtrans = 0.750085 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:12:31 Voltage Offset Correction: v_off_ini = -0.000000674 V, v_off_fin = -0.000033507 V 19:12:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003149217 Vs 19:12:38 Voltage Offset Correction: v_off_ini = -0.000000959 V, v_off_fin = -0.000005934 V 19:12:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003129469 Vs 19:12:38 Magnet Current for Main , Imag = 74.9849 A Vtrans = 0.750085 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:12:45 Voltage Offset Correction: v_off_ini = -0.000000790 V, v_off_fin = 0.000025642 V 19:12:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003117706 Vs 19:12:51 Voltage Offset Correction: v_off_ini = -0.000000739 V, v_off_fin = 0.000030131 V 19:12:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003148214 Vs 19:12:52 Magnet Current for Main , Imag = 74.9849 A Vtrans = 0.750085 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:12:59 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000029547 V 19:12:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003147524 Vs 19:13:05 Voltage Offset Correction: v_off_ini = -0.000001587 V, v_off_fin = -0.000021890 V 19:13:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003120731 Vs 19:13:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003135536 +- 0.000005878 Vs 19:13:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003135536 +- 0.000005878 Vs BL = 0.31355355 +- 0.00058779 Tm 19:13:09 Position moved: 0.000000 m 19:13:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31355 0.00059 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.31355 0.00059 0.31355 0.00000 19:13:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31355 0.00059 SL = 0.3135536 +- 0.0005878 Tm^2/m^n 19:13:09 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3135536 +- 0.0005878 Tm^2/m^n 19:13:12 Position moved: 0.000000 m 19:13:12 Magnet system Main current ramping to 60.0000 A... 19:13:27 Magnet Current for Main , Imag = 60.0338 A Vtrans = 0.600573 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:13:27 MAIN Voltage Measurement, V = 4.254976 V 19:13:28 Temperature Measurement, Probe Number = 0, T = 28.940000 C 19:13:29 Temperature Measurement, Probe Number = 1, T = 29.208000 C 19:13:29 Temperature Measurement, Probe Number = 2, T = 26.128000 C 19:13:29 Magnet Test Parameter Measurements P0 = Main , Value = 60.03 P1 = MAIN, Value = 4.25 P2 = Steel, Value = 28.94 P3 = Coil, Value = 29.21 P4 = Ambient Temp, Value = 26.13 19:13:29 Magnetic Field Measurement Measuring the magnet strength... 19:13:29 Integrated Voltage Measurement... 19:13:30 Magnet Current for Main , Imag = 60.0340 A Vtrans = 0.600576 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:13:38 Voltage Offset Correction: v_off_ini = 0.000001206 V, v_off_fin = -0.000026729 V 19:13:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002527201 Vs 19:13:44 Voltage Offset Correction: v_off_ini = -0.000001483 V, v_off_fin = -0.000008040 V 19:13:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002510878 Vs 19:13:45 Magnet Current for Main , Imag = 60.0337 A Vtrans = 0.600572 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:13:52 Voltage Offset Correction: v_off_ini = -0.000001435 V, v_off_fin = 0.000027514 V 19:13:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002500170 Vs 19:13:58 Voltage Offset Correction: v_off_ini = -0.000001243 V, v_off_fin = 0.000038699 V 19:13:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002535865 Vs 19:13:59 Magnet Current for Main , Imag = 60.0336 A Vtrans = 0.600572 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:14:05 Voltage Offset Correction: v_off_ini = -0.000000810 V, v_off_fin = -0.000021880 V 19:14:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002526174 Vs 19:14:12 Voltage Offset Correction: v_off_ini = -0.000000628 V, v_off_fin = 0.000018601 V 19:14:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002525739 Vs 19:14:12 Magnet Current for Main , Imag = 60.0337 A Vtrans = 0.600573 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:14:19 Voltage Offset Correction: v_off_ini = -0.000000977 V, v_off_fin = -0.000004379 V 19:14:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002517113 Vs 19:14:25 Voltage Offset Correction: v_off_ini = -0.000001105 V, v_off_fin = 0.000027794 V 19:14:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002529841 Vs 19:14:26 Magnet Current for Main , Imag = 60.0336 A Vtrans = 0.600571 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:14:33 Voltage Offset Correction: v_off_ini = -0.000001342 V, v_off_fin = -0.000014642 V 19:14:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002521975 Vs 19:14:39 Voltage Offset Correction: v_off_ini = -0.000001107 V, v_off_fin = -0.000010107 V 19:14:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002509945 Vs 19:14:40 Magnet Current for Main , Imag = 60.0335 A Vtrans = 0.600571 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:14:47 Voltage Offset Correction: v_off_ini = -0.000000939 V, v_off_fin = -0.000030723 V 19:14:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002530551 Vs 19:14:53 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = 0.000042135 V 19:14:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002537597 Vs 19:14:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002522754 +- 0.000006073 Vs 19:14:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.002522754 +- 0.000006073 Vs BL = 0.25227541 +- 0.00060733 Tm 19:14:57 Position moved: 0.000000 m 19:14:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.25228 0.00061 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.25228 0.00061 0.25228 0.00000 19:14:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.25228 0.00061 SL = 0.2522754 +- 0.0006073 Tm^2/m^n 19:14:57 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2522754 +- 0.0006073 Tm^2/m^n 19:15:00 Position moved: 0.000000 m 19:15:00 Magnet system Main current ramping to 45.0000 A... 19:15:15 Magnet Current for Main , Imag = 45.0121 A Vtrans = 0.450356 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:15:16 MAIN Voltage Measurement, V = 3.188341 V 19:15:16 Temperature Measurement, Probe Number = 0, T = 28.904000 C 19:15:17 Temperature Measurement, Probe Number = 1, T = 29.113000 C 19:15:17 Temperature Measurement, Probe Number = 2, T = 26.153000 C 19:15:17 Magnet Test Parameter Measurements P0 = Main , Value = 45.01 P1 = MAIN, Value = 3.19 P2 = Steel, Value = 28.90 P3 = Coil, Value = 29.11 P4 = Ambient Temp, Value = 26.15 19:15:17 Magnetic Field Measurement Measuring the magnet strength... 19:15:17 Integrated Voltage Measurement... 19:15:18 Magnet Current for Main , Imag = 45.0123 A Vtrans = 0.450359 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:15:26 Voltage Offset Correction: v_off_ini = -0.000001513 V, v_off_fin = -0.000020279 V 19:15:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001905119 Vs 19:15:32 Voltage Offset Correction: v_off_ini = -0.000001540 V, v_off_fin = 0.000025426 V 19:15:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001908420 Vs 19:15:33 Magnet Current for Main , Imag = 45.0121 A Vtrans = 0.450356 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:15:40 Voltage Offset Correction: v_off_ini = -0.000001096 V, v_off_fin = -0.000021362 V 19:15:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001905026 Vs 19:15:46 Voltage Offset Correction: v_off_ini = -0.000001329 V, v_off_fin = 0.000001457 V 19:15:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001895931 Vs 19:15:47 Magnet Current for Main , Imag = 45.0122 A Vtrans = 0.450358 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:15:53 Voltage Offset Correction: v_off_ini = -0.000000763 V, v_off_fin = -0.000017974 V 19:15:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001903445 Vs 19:16:00 Voltage Offset Correction: v_off_ini = -0.000001213 V, v_off_fin = -0.000009392 V 19:16:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001890121 Vs 19:16:01 Magnet Current for Main , Imag = 45.0125 A Vtrans = 0.450360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:16:07 Voltage Offset Correction: v_off_ini = -0.000001059 V, v_off_fin = -0.000021420 V 19:16:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001905137 Vs 19:16:14 Voltage Offset Correction: v_off_ini = -0.000001392 V, v_off_fin = -0.000024959 V 19:16:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001881507 Vs 19:16:14 Magnet Current for Main , Imag = 45.0121 A Vtrans = 0.450357 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:16:21 Voltage Offset Correction: v_off_ini = -0.000001207 V, v_off_fin = -0.000021855 V 19:16:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001905333 Vs 19:16:27 Voltage Offset Correction: v_off_ini = -0.000001034 V, v_off_fin = 0.000031753 V 19:16:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001911813 Vs 19:16:28 Magnet Current for Main , Imag = 45.0121 A Vtrans = 0.450357 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:16:35 Voltage Offset Correction: v_off_ini = -0.000001434 V, v_off_fin = 0.000020451 V 19:16:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001882878 Vs 19:16:41 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = 0.000002149 V 19:16:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001895760 Vs 19:16:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001899208 +- 0.000006890 Vs 19:16:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001899208 +- 0.000006890 Vs BL = 0.18992076 +- 0.00068897 Tm 19:16:45 Position moved: 0.000000 m 19:16:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.18992 0.00069 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.18992 0.00069 0.18992 0.00000 19:16:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.18992 0.00069 SL = 0.1899208 +- 0.0006890 Tm^2/m^n 19:16:45 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1899208 +- 0.0006890 Tm^2/m^n 19:16:48 Position moved: 0.000000 m 19:16:48 Magnet system Main current ramping to 30.0000 A... 19:17:03 Magnet Current for Main , Imag = 29.9878 A Vtrans = 0.300114 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:17:04 MAIN Voltage Measurement, V = 2.123070 V 19:17:04 Temperature Measurement, Probe Number = 0, T = 28.897000 C 19:17:05 Temperature Measurement, Probe Number = 1, T = 29.050000 C 19:17:05 Temperature Measurement, Probe Number = 2, T = 26.152000 C 19:17:05 Magnet Test Parameter Measurements P0 = Main , Value = 29.99 P1 = MAIN, Value = 2.12 P2 = Steel, Value = 28.90 P3 = Coil, Value = 29.05 P4 = Ambient Temp, Value = 26.15 19:17:05 Magnetic Field Measurement Measuring the magnet strength... 19:17:05 Integrated Voltage Measurement... 19:17:06 Magnet Current for Main , Imag = 29.9881 A Vtrans = 0.300117 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:17:14 Voltage Offset Correction: v_off_ini = 0.000000336 V, v_off_fin = 0.000010149 V 19:17:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001266966 Vs 19:17:20 Voltage Offset Correction: v_off_ini = -0.000001290 V, v_off_fin = 0.000005036 V 19:17:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001276399 Vs 19:17:21 Magnet Current for Main , Imag = 29.9879 A Vtrans = 0.300115 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:17:28 Voltage Offset Correction: v_off_ini = -0.000001128 V, v_off_fin = -0.000016303 V 19:17:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001281381 Vs 19:17:34 Voltage Offset Correction: v_off_ini = -0.000001450 V, v_off_fin = 0.000022213 V 19:17:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001285638 Vs 19:17:35 Magnet Current for Main , Imag = 29.9878 A Vtrans = 0.300113 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:17:41 Voltage Offset Correction: v_off_ini = -0.000001290 V, v_off_fin = -0.000018713 V 19:17:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001282626 Vs 19:17:48 Voltage Offset Correction: v_off_ini = -0.000001231 V, v_off_fin = -0.000020521 V 19:17:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001263169 Vs 19:17:49 Magnet Current for Main , Imag = 29.9879 A Vtrans = 0.300115 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:17:55 Voltage Offset Correction: v_off_ini = -0.000001191 V, v_off_fin = 0.000016285 V 19:17:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001264206 Vs 19:18:02 Voltage Offset Correction: v_off_ini = -0.000000921 V, v_off_fin = 0.000005242 V 19:18:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001277087 Vs 19:18:03 Magnet Current for Main , Imag = 29.9879 A Vtrans = 0.300115 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:18:09 Voltage Offset Correction: v_off_ini = -0.000001168 V, v_off_fin = 0.000012937 V 19:18:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001265773 Vs 19:18:16 Voltage Offset Correction: v_off_ini = -0.000001297 V, v_off_fin = -0.000007839 V 19:18:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001269445 Vs 19:18:16 Magnet Current for Main , Imag = 29.9878 A Vtrans = 0.300114 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:18:23 Voltage Offset Correction: v_off_ini = -0.000001098 V, v_off_fin = -0.000017491 V 19:18:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001281983 Vs 19:18:30 Voltage Offset Correction: v_off_ini = -0.000000698 V, v_off_fin = 0.000010449 V 19:18:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001279285 Vs 19:18:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001274496 +- 0.000005652 Vs 19:18:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001274496 +- 0.000005652 Vs BL = 0.12744965 +- 0.00056516 Tm 19:18:33 Position moved: 0.000000 m 19:18:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.12745 0.00057 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.12745 0.00057 0.12745 0.00000 19:18:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12745 0.00057 SL = 0.1274496 +- 0.0005652 Tm^2/m^n 19:18:33 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1274496 +- 0.0005652 Tm^2/m^n 19:18:36 Position moved: 0.000000 m 19:18:36 Magnet system Main current ramping to 15.0000 A... 19:18:51 Magnet Current for Main , Imag = 14.9664 A Vtrans = 0.149900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:18:52 MAIN Voltage Measurement, V = 1.059105 V 19:18:52 Temperature Measurement, Probe Number = 0, T = 28.870000 C 19:18:53 Temperature Measurement, Probe Number = 1, T = 28.992000 C 19:18:54 Temperature Measurement, Probe Number = 2, T = 26.077000 C 19:18:54 Magnet Test Parameter Measurements P0 = Main , Value = 14.97 P1 = MAIN, Value = 1.06 P2 = Steel, Value = 28.87 P3 = Coil, Value = 28.99 P4 = Ambient Temp, Value = 26.08 19:18:54 Magnetic Field Measurement Measuring the magnet strength... 19:18:54 Integrated Voltage Measurement... 19:18:54 Magnet Current for Main , Imag = 14.9666 A Vtrans = 0.149901 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:19:02 Voltage Offset Correction: v_off_ini = -0.000000447 V, v_off_fin = -0.000007518 V 19:19:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000655301 Vs 19:19:08 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = -0.000002348 V 19:19:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000651704 Vs 19:19:09 Magnet Current for Main , Imag = 14.9661 A Vtrans = 0.149897 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:19:16 Voltage Offset Correction: v_off_ini = -0.000001137 V, v_off_fin = 0.000003549 V 19:19:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000649895 Vs 19:19:22 Voltage Offset Correction: v_off_ini = -0.000000626 V, v_off_fin = 0.000009973 V 19:19:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000657959 Vs 19:19:23 Magnet Current for Main , Imag = 14.9660 A Vtrans = 0.149895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:19:29 Voltage Offset Correction: v_off_ini = -0.000001314 V, v_off_fin = -0.000009553 V 19:19:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000656601 Vs 19:19:36 Voltage Offset Correction: v_off_ini = -0.000001088 V, v_off_fin = -0.000000294 V 19:19:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000652722 Vs 19:19:36 Magnet Current for Main , Imag = 14.9661 A Vtrans = 0.149897 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:19:43 Voltage Offset Correction: v_off_ini = -0.000001032 V, v_off_fin = 0.000003259 V 19:19:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000649814 Vs 19:19:50 Voltage Offset Correction: v_off_ini = -0.000000892 V, v_off_fin = 0.000006116 V 19:19:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000656002 Vs 19:19:51 Magnet Current for Main , Imag = 14.9661 A Vtrans = 0.149896 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:19:57 Voltage Offset Correction: v_off_ini = -0.000001222 V, v_off_fin = -0.000011757 V 19:19:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000657730 Vs 19:20:04 Voltage Offset Correction: v_off_ini = -0.000000806 V, v_off_fin = 0.000010996 V 19:20:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000658532 Vs 19:20:04 Magnet Current for Main , Imag = 14.9660 A Vtrans = 0.149896 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:20:11 Voltage Offset Correction: v_off_ini = -0.000001078 V, v_off_fin = -0.000009926 V 19:20:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000656815 Vs 19:20:17 Voltage Offset Correction: v_off_ini = -0.000001163 V, v_off_fin = -0.000004458 V 19:20:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000650219 Vs 19:20:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000654441 +- 0.000001733 Vs 19:20:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000654441 +- 0.000001733 Vs BL = 0.06544412 +- 0.00017328 Tm 19:20:21 Position moved: 0.000000 m 19:20:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.06544 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.06544 0.00017 0.06544 0.00000 19:20:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.06544 0.00017 SL = 0.0654441 +- 0.0001733 Tm^2/m^n 19:20:21 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0654441 +- 0.0001733 Tm^2/m^n 19:20:24 Position moved: 0.000000 m 19:20:24 Magnet system Main current ramping to 0.0000 A... 19:20:39 Magnet Current for Main , Imag = 0.0080 A Vtrans = 0.000316 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:20:40 MAIN Voltage Measurement, V = 0.000649 V 19:20:40 Temperature Measurement, Probe Number = 0, T = 28.850000 C 19:20:41 Temperature Measurement, Probe Number = 1, T = 28.971000 C 19:20:42 Temperature Measurement, Probe Number = 2, T = 26.168000 C 19:20:42 Magnet Test Parameter Measurements P0 = Main , Value = 0.01 P1 = MAIN, Value = 0.00 P2 = Steel, Value = 28.85 P3 = Coil, Value = 28.97 P4 = Ambient Temp, Value = 26.17 19:20:42 Magnetic Field Measurement Measuring the magnet strength... 19:20:42 Integrated Voltage Measurement... 19:20:42 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000317 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:20:50 Voltage Offset Correction: v_off_ini = -0.000001181 V, v_off_fin = -0.000001619 V 19:20:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000034350 Vs 19:20:56 Voltage Offset Correction: v_off_ini = -0.000001206 V, v_off_fin = -0.000001476 V 19:20:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000034137 Vs 19:20:57 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:21:03 Voltage Offset Correction: v_off_ini = -0.000001095 V, v_off_fin = -0.000001086 V 19:21:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000034030 Vs 19:21:10 Voltage Offset Correction: v_off_ini = -0.000001085 V, v_off_fin = -0.000000324 V 19:21:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000034462 Vs 19:21:11 Magnet Current for Main , Imag = 0.0083 A Vtrans = 0.000319 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:21:17 Voltage Offset Correction: v_off_ini = -0.000001131 V, v_off_fin = -0.000001536 V 19:21:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000034273 Vs 19:21:24 Voltage Offset Correction: v_off_ini = -0.000001193 V, v_off_fin = -0.000001482 V 19:21:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000033943 Vs 19:21:25 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:21:31 Voltage Offset Correction: v_off_ini = -0.000000938 V, v_off_fin = -0.000000905 V 19:21:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000034007 Vs 19:21:38 Voltage Offset Correction: v_off_ini = -0.000001085 V, v_off_fin = -0.000000940 V 19:21:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000033954 Vs 19:21:38 Magnet Current for Main , Imag = 0.0082 A Vtrans = 0.000318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:21:45 Voltage Offset Correction: v_off_ini = -0.000001098 V, v_off_fin = -0.000000806 V 19:21:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000033879 Vs 19:21:52 Voltage Offset Correction: v_off_ini = -0.000000954 V, v_off_fin = -0.000000690 V 19:21:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000034202 Vs 19:21:52 Magnet Current for Main , Imag = 0.0083 A Vtrans = 0.000318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.023572 A 19:21:59 Voltage Offset Correction: v_off_ini = -0.000001035 V, v_off_fin = -0.000001702 V 19:21:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000034171 Vs 19:22:05 Voltage Offset Correction: v_off_ini = -0.000001377 V, v_off_fin = -0.000000659 V 19:22:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000034265 Vs 19:22:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000034140 +- 0.000000104 Vs 19:22:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000034140 +- 0.000000104 Vs BL = 0.00341395 +- 0.00001037 Tm 19:22:09 Position moved: 0.000000 m 19:22:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00341 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00341 0.00001 0.00341 0.00000 19:22:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00341 0.00001 SL = 0.0034140 +- 0.0000104 Tm^2/m^n 19:22:09 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0034140 +- 0.0000104 Tm^2/m^n 19:22:12 Position moved: 0.000000 m 19:22:15 Position moved: 0.000000 m 19:22:18 Magnet system Main current ramping to 0.0000 A...