SLAC Magnetic Measurements Date: 09-27-2022 Time: 17:46:32 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: 2V-TW; Skew Quad Center position: X0=0.000000, Y0=0.000000 Nominal Gap=33.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 0.449E-06 6.415E-06 33.00000 33.00020 0 33.00010 0 33.00025 0 33.00010 0 1 0.408E-06 5.827E-06 33.00000 33.00020 0 33.00010 0 33.00030 0 33.00005 0 2 0.495E-06 7.077E-06 33.00000 33.00025 0 33.00010 0 33.00025 0 33.00010 0 3 0.534E-06 7.632E-06 33.00000 33.00025 0 33.00010 0 33.00025 0 33.00010 0 4 0.457E-06 6.523E-06 33.00000 33.00025 0 33.00010 0 33.00025 0 33.00010 0