SLAC Magnetic Measurements Date: 09-27-2022 Time: 17:05:18 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: 2V-TW; Skew Quad Center position: X0=-0.001000, Y0=0.000000 Nominal Gap=15.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.282E-06 18.306E-06 15.00000 15.00145 0 15.00015 0 15.00150 0 15.00015 0 1 1.078E-06 15.399E-06 15.00000 15.00145 0 15.00020 0 15.00150 0 15.00020 0 2 1.179E-06 16.835E-06 15.00000 15.00150 0 15.00020 0 15.00150 0 15.00020 0 3 1.318E-06 18.825E-06 15.00000 15.00150 0 15.00020 0 15.00150 0 15.00015 0 4 1.128E-06 16.116E-06 15.00000 15.00150 0 15.00020 0 15.00155 0 15.00020 0