SLAC Magnetic Measurements Date: 09-27-2022 Time: 16:22:45 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: 2V-TW; Skew Quad Center position: X0=0.000000, Y0=0.000000 Nominal Gap=9.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.294E-06 18.478E-06 9.00000 9.00040 0 9.00045 0 9.00040 0 9.00045 0 1 1.215E-06 17.356E-06 9.00000 9.00040 0 9.00045 0 9.00045 0 9.00045 0 2 1.310E-06 18.718E-06 9.00000 9.00045 0 9.00040 0 9.00040 0 9.00045 0 3 1.144E-06 16.345E-06 9.00000 9.00045 0 9.00040 0 9.00045 0 9.00045 0 4 1.148E-06 16.398E-06 9.00000 9.00045 0 9.00045 0 9.00040 0 9.00050 0