SLAC Magnetic Measurements Date: 10-04-2022 Time: 15:23:03 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 77 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4 Small Center position: X0=0.000000, Y0=0.000000 Nominal Gap=8.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.035E-06 14.777E-06 8.00000 8.00030 0 8.00035 0 8.00030 0 8.00035 0 1 0.997E-06 14.247E-06 8.00000 8.00030 0 8.00035 0 8.00030 0 8.00035 0 2 0.895E-06 12.788E-06 8.00000 8.00030 0 8.00040 0 8.00030 0 8.00040 0 3 0.931E-06 13.292E-06 8.00000 8.00035 0 8.00040 0 8.00035 0 8.00040 0 4 0.858E-06 12.259E-06 8.00000 8.00030 0 8.00040 0 8.00035 0 8.00040 0