SLAC Magnetic Measurements Date: 09-28-2022 Time: 11:26:46 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 64 Measurement Type: Long Coil Scans Operator: YL Comment: 2H-TW; Skew Quad Center position: X0=0.001000, Y0=0.000000 Nominal Gap=20.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 0.388E-06 5.547E-06 20.00000 20.00125 0 20.00070 0 20.00125 0 20.00070 0 1 0.556E-06 7.939E-06 20.00000 20.00125 0 20.00075 0 20.00125 0 20.00075 0 2 0.667E-06 9.520E-06 20.00000 20.00125 0 20.00075 0 20.00125 0 20.00075 0 3 0.968E-06 13.822E-06 20.00000 20.00125 0 20.00075 0 20.00130 0 20.00075 0 4 0.561E-06 8.015E-06 20.00000 20.00125 0 20.00075 0 20.00125 0 20.00075 0