SLAC Magnetic Measurements Date: 09-28-2022 Time: 09:54:14 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 64 Measurement Type: Long Coil Scans Operator: YL Comment: 2H-TW; Skew Quad Center position: X0=0.000000, Y0=0.000000 Nominal Gap=7.50 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 0.836E-06 11.936E-06 7.50000 7.50035 0 7.50050 0 7.50035 0 7.50050 0 1 0.844E-06 12.052E-06 7.50000 7.50035 0 7.50050 0 7.50035 0 7.50050 0 2 1.084E-06 15.479E-06 7.50000 7.50035 0 7.50050 0 7.50035 0 7.50050 0 3 0.985E-06 14.075E-06 7.50000 7.50035 0 7.50050 0 7.50035 0 7.50055 0 4 0.995E-06 14.210E-06 7.50000 7.50035 0 7.50050 0 7.50035 0 7.50050 0