SLAC Magnetic Measurements Date: 10-03-2022 Time: 18:16:14 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 74 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4V Center position: X0=0.000000, Y0=0.000000 Nominal Gap=40.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -0.674E-06 -9.633E-06 40.00000 40.00020 0 40.00005 0 40.00020 0 40.00010 0 1 -0.553E-06 -7.893E-06 40.00000 40.00025 0 40.00005 0 40.00020 0 40.00010 0 2 -0.562E-06 -8.025E-06 40.00000 40.00020 0 40.00010 0 40.00020 0 40.00005 0 3 -0.415E-06 -5.923E-06 40.00000 40.00025 0 40.00005 0 40.00025 0 40.00005 0 4 -0.441E-06 -6.293E-06 40.00000 40.00025 0 40.00010 0 40.00025 0 40.00010 0