SLAC Magnetic Measurements Date: 10-04-2022 Time: 11:58:11 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 75 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4H Center position: X0=-0.002000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -6.177E-06 -88.219E-06 75.00000 75.00015 0 75.00015 0 75.00020 0 75.00010 0 1 -5.913E-06 -84.458E-06 75.00000 75.00020 0 75.00010 0 75.00020 0 75.00015 0 2 -6.079E-06 -86.821E-06 75.00000 75.00020 0 75.00010 0 75.00025 0 75.00010 0 3 -5.746E-06 -82.068E-06 75.00000 75.00025 0 75.00010 0 75.00020 0 75.00010 0 4 -5.508E-06 -78.668E-06 75.00000 75.00020 0 75.00015 0 75.00015 0 75.00020 0