SLAC Magnetic Measurements Date: 10-04-2022 Time: 11:52:40 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 75 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4H Center position: X0=0.000000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -1.861E-06 -26.580E-06 75.00000 75.00015 0 75.00000 0 75.00010 0 75.00005 0 1 -1.527E-06 -21.813E-06 75.00000 75.00015 0 75.00010 0 75.00015 0 75.00010 0 2 -1.676E-06 -23.935E-06 75.00000 75.00015 0 75.00010 0 75.00015 0 75.00010 0 3 -1.511E-06 -21.585E-06 75.00000 75.00020 0 75.00000 0 75.00015 0 75.00005 0 4 -1.626E-06 -23.220E-06 75.00000 75.00015 0 75.00010 0 75.00015 0 75.00010 0