SLAC Magnetic Measurements Date: 10-04-2022 Time: 11:36:31 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 75 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4H Center position: X0=0.000000, Y0=0.000000 Nominal Gap=50.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -0.958E-06 -13.680E-06 50.00000 50.00020 0 50.00010 0 50.00015 0 50.00015 0 1 -0.870E-06 -12.429E-06 50.00000 50.00015 0 50.00015 0 50.00015 0 50.00020 0 2 -0.995E-06 -14.208E-06 50.00000 50.00020 0 50.00010 0 50.00020 0 50.00010 0 3 -1.035E-06 -14.789E-06 50.00000 50.00015 0 50.00020 0 50.00015 0 50.00015 0 4 -1.052E-06 -15.021E-06 50.00000 50.00020 0 50.00015 0 50.00020 0 50.00010 0