SLAC Magnetic Measurements Date: 06-03-2024 Time: 17:17:07 Project: LCLS-II-HE Magnet Type: Quad Magnet Name: 4267 Serial Number: Run Number: 3 Measurement Device: 10wire Operator: sda Comment: Htrim integrated strength at +/- 1 A. After main Stdz and set to 0 A Standardization for MAIN: 3 cycles from -6.0 A to 6.0 A to -6.0 A Test Currents for MAIN (A): 0.00 0.00 0.00 0.00 0.00 0.00 Test Currents for HTRIM (A): -1.00 1.00 -1.00 1.00 -1.00 1.00 Integrated Dipole Strength Distance the wire was to be moved = 0.006000 m Number of turns in the wire = 10 Number of measurements for averaging = 5 MAIN +/- sigma HTRIM +/- sigma BL sigBL BL/I sigBL/I (A) (A) (A) (A) (Tm) (Tm) (Tm/A) (Tm/A) ------------+---------- ------------+---------- -------------+------------ -------------+------------- 0.0053 0.0001 -0.9993 0.0000 -0.000672 0.000069 0.000000 0.000000 0.0054 0.0001 1.0011 0.0000 0.000694 0.000080 0.000000 0.000000 0.0054 0.0001 -0.9993 0.0000 -0.000615 0.000091 0.000000 0.000000 0.0054 0.0001 1.0011 0.0000 0.000589 0.000079 0.000000 0.000000 0.0054 0.0001 -0.9993 0.0000 -0.000689 0.000066 0.000000 0.000000 0.0053 0.0001 1.0011 0.0000 0.000657 0.000089 0.000000 0.000000