SLAC Magnetic Measurements Date: 01-17-2025 Time: 12:36:40 Project: LBL Magnet Type: Quad Magnet Name: TQFC_Q11_BTA_QF8 Serial Number: AL-1423-8026-0001 Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integrated gradient at 185 amps for coil calibration Standardization for MAIN: 3 cycles from 0.0 A to 185.0 A to 0.0 A Test Currents for MAIN (A): 185.00 185.00 185.00 Integrated Quadrupole Gradient Distance the wire was to be moved = 0.006250 m Number of turns in the wire = 10 Number of measurements for averaging = 5 MAIN +/- sigma GL sigGL GL/I sigGL/I (A) (A) (T) (T) (T/A) (T/A) ------------+---------- -------------+------------ -------------+------------- 184.9720 0.0001 10.627865 0.002237 0.057457 0.000012