SLAC Magnetic Measurements Date: 01-23-2025 Time: 10:04:03 Project: LBL Magnet Type: Quad Magnet Name: TQFC_Q11_BTA_QF8 Serial Number: AL-1423-8026-0001 Run Number: 6 Measurement Device: 1DQB26 Operator: sda Comment: Check Sens factor after changing BLHar Ref Radius. Moved coil 25 microns to left Standardization for MAIN: 3 cycles from 0.0 A to 185.0 A to 0.0 A Test Currents for MAIN (A): 185.00 Integrated Gradient (Quadrupole) MAIN +/- sigma BL sigBL TF sigTF THsp sigTHsp (A) (T) (T/A) (deg) ------------+---------- -----------+----------- ------------+------------ -----------+--------- 184.9637 0.0005 10.626266 0.000047 0.057451 0.000000 45.0512 0.0001