SLAC Magnetic Measurements Date: 01-15-2025 Time: 09:32:23 Project: LBL Magnet Type: Quad Magnet Name: Q10_BTA_QD8 Serial Number: 0001 Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integrated gradient at 150 amps for coil calibration Standardization for MAIN: 3 cycles from 0.0 A to 150.0 A to 0.0 A Test Currents for MAIN (A): 150.00 150.00 150.00 09:32:53 Position moved: 0.000000 m 09:32:56 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:32:57 Magnet Current for MAIN, Imag = -0.0001 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:32:57 Magnet Current for MAIN, Imag = -0.0001 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:32:58 Magnet Current for MAIN, Imag = -0.0001 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:32:58 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0002 +- 0.0001 A 09:33:33 Initial Zero Current Measurement for MAIN, Imag_zero = -0.00017085 A 09:33:33 Ambient Measurement Device(s) Being Used, type = None 09:33:33 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 09:33:34 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 09:33:34 XMAG Device(s) Being Used, type = None 09:33:34 Ambient Measurement Device(s) Being Used, type = HP34970 09:33:35 Magnet system MAIN current ramping to 150.0000 A... 09:33:51 Magnet Current for MAIN, Imag = 149.9847 A Vtrans = 1.499845 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:33:51 Main (V) Voltage Measurement, V = 10.466150 V 09:33:58 Temperature Measurement, Probe Number = 0, T = 20.967000 C 09:33:59 Temperature Measurement, Probe Number = 1, T = 23.368000 C 09:33:59 Temperature Measurement, Probe Number = 2, T = 27.364000 C 09:34:00 Temperature Measurement, Probe Number = 3, T = 26.523000 C 09:34:01 Temperature Measurement, Probe Number = 4, T = 14.003000 C 09:34:01 Sensor Voltage Measurement, Sensor Number = 0, V = 2.656805 V 09:34:01 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656805 (V, A, ohm, ...), Measured Value = 124.260413 (C, atm, Hz, ...) 09:34:02 Sensor Voltage Measurement, Sensor Number = 1, V = 1.160678 V 09:34:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.160678 (V, A, ohm, ...), Measured Value = 12.050843 (C, atm, Hz, ...) 09:34:03 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001184 V 09:34:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001184 (V, A, ohm, ...), Measured Value = 1.184366 (C, atm, Hz, ...) 09:34:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.98 P1 = Main (V), Value = 10.47 P2 = Core_Top, Value = 20.97 P3 = Top_Coil, Value = 23.37 P4 = H20 In, Value = 27.36 P5 = H20 Out, Value = 26.52 P6 = Ambient, Value = 14.00 P7 = Supply Pres(psi), Value = 124.26 P8 = Return Pres(psi), Value = 12.05 P9 = Flow Rate(gpm), Value = 1.18 09:35:04 Magnet Current for MAIN, Imag = 149.9733 A Vtrans = 1.499731 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:35:04 Main (V) Voltage Measurement, V = 10.549719 V 09:35:08 Temperature Measurement, Probe Number = 0, T = 20.930000 C 09:35:08 Temperature Measurement, Probe Number = 1, T = 23.531000 C 09:35:09 Temperature Measurement, Probe Number = 2, T = 27.358000 C 09:35:10 Temperature Measurement, Probe Number = 3, T = 28.802000 C 09:35:10 Temperature Measurement, Probe Number = 4, T = 13.995000 C 09:35:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.658986 V 09:35:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658986 (V, A, ohm, ...), Measured Value = 124.423928 (C, atm, Hz, ...) 09:35:12 Sensor Voltage Measurement, Sensor Number = 1, V = 1.160180 V 09:35:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.160180 (V, A, ohm, ...), Measured Value = 12.013478 (C, atm, Hz, ...) 09:35:12 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001175 V 09:35:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001175 (V, A, ohm, ...), Measured Value = 1.175210 (C, atm, Hz, ...) 09:35:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.55 P2 = Core_Top, Value = 20.93 P3 = Top_Coil, Value = 23.53 P4 = H20 In, Value = 27.36 P5 = H20 Out, Value = 28.80 P6 = Ambient, Value = 13.99 P7 = Supply Pres(psi), Value = 124.42 P8 = Return Pres(psi), Value = 12.01 P9 = Flow Rate(gpm), Value = 1.18 09:36:13 Magnet Current for MAIN, Imag = 149.9730 A Vtrans = 1.499728 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:36:14 Main (V) Voltage Measurement, V = 10.552654 V 09:36:17 Temperature Measurement, Probe Number = 0, T = 20.942000 C 09:36:18 Temperature Measurement, Probe Number = 1, T = 23.839000 C 09:36:19 Temperature Measurement, Probe Number = 2, T = 27.372000 C 09:36:19 Temperature Measurement, Probe Number = 3, T = 30.243000 C 09:36:20 Temperature Measurement, Probe Number = 4, T = 13.994000 C 09:36:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.645135 V 09:36:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.645135 (V, A, ohm, ...), Measured Value = 123.385162 (C, atm, Hz, ...) 09:36:21 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158234 V 09:36:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158234 (V, A, ohm, ...), Measured Value = 11.867572 (C, atm, Hz, ...) 09:36:22 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001184 V 09:36:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001184 (V, A, ohm, ...), Measured Value = 1.183725 (C, atm, Hz, ...) 09:36:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.55 P2 = Core_Top, Value = 20.94 P3 = Top_Coil, Value = 23.84 P4 = H20 In, Value = 27.37 P5 = H20 Out, Value = 30.24 P6 = Ambient, Value = 13.99 P7 = Supply Pres(psi), Value = 123.39 P8 = Return Pres(psi), Value = 11.87 P9 = Flow Rate(gpm), Value = 1.18 09:37:23 Magnet Current for MAIN, Imag = 149.9721 A Vtrans = 1.499719 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:37:24 Main (V) Voltage Measurement, V = 10.553953 V 09:37:27 Temperature Measurement, Probe Number = 0, T = 20.969000 C 09:37:28 Temperature Measurement, Probe Number = 1, T = 24.143000 C 09:37:28 Temperature Measurement, Probe Number = 2, T = 27.372000 C 09:37:29 Temperature Measurement, Probe Number = 3, T = 30.758000 C 09:37:30 Temperature Measurement, Probe Number = 4, T = 14.042000 C 09:37:30 Sensor Voltage Measurement, Sensor Number = 0, V = 2.647592 V 09:37:30 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.647592 (V, A, ohm, ...), Measured Value = 123.569370 (C, atm, Hz, ...) 09:37:31 Sensor Voltage Measurement, Sensor Number = 1, V = 1.160630 V 09:37:31 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.160630 (V, A, ohm, ...), Measured Value = 12.047287 (C, atm, Hz, ...) 09:37:32 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001184 V 09:37:32 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001184 (V, A, ohm, ...), Measured Value = 1.184364 (C, atm, Hz, ...) 09:37:32 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.55 P2 = Core_Top, Value = 20.97 P3 = Top_Coil, Value = 24.14 P4 = H20 In, Value = 27.37 P5 = H20 Out, Value = 30.76 P6 = Ambient, Value = 14.04 P7 = Supply Pres(psi), Value = 123.57 P8 = Return Pres(psi), Value = 12.05 P9 = Flow Rate(gpm), Value = 1.18 09:38:33 Magnet Current for MAIN, Imag = 149.9728 A Vtrans = 1.499726 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:38:33 Main (V) Voltage Measurement, V = 10.554791 V 09:38:37 Temperature Measurement, Probe Number = 0, T = 20.997000 C 09:38:38 Temperature Measurement, Probe Number = 1, T = 24.347000 C 09:38:38 Temperature Measurement, Probe Number = 2, T = 27.386000 C 09:38:39 Temperature Measurement, Probe Number = 3, T = 31.015000 C 09:38:40 Temperature Measurement, Probe Number = 4, T = 14.082000 C 09:38:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.662172 V 09:38:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662172 (V, A, ohm, ...), Measured Value = 124.662922 (C, atm, Hz, ...) 09:38:41 Sensor Voltage Measurement, Sensor Number = 1, V = 1.160210 V 09:38:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.160210 (V, A, ohm, ...), Measured Value = 12.015728 (C, atm, Hz, ...) 09:38:41 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001165 V 09:38:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001165 (V, A, ohm, ...), Measured Value = 1.164527 (C, atm, Hz, ...) 09:38:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.55 P2 = Core_Top, Value = 21.00 P3 = Top_Coil, Value = 24.35 P4 = H20 In, Value = 27.39 P5 = H20 Out, Value = 31.02 P6 = Ambient, Value = 14.08 P7 = Supply Pres(psi), Value = 124.66 P8 = Return Pres(psi), Value = 12.02 P9 = Flow Rate(gpm), Value = 1.16 09:39:42 Magnet Current for MAIN, Imag = 149.9726 A Vtrans = 1.499724 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:39:43 Main (V) Voltage Measurement, V = 10.555544 V 09:39:47 Temperature Measurement, Probe Number = 0, T = 21.033000 C 09:39:47 Temperature Measurement, Probe Number = 1, T = 24.518000 C 09:39:48 Temperature Measurement, Probe Number = 2, T = 27.390000 C 09:39:49 Temperature Measurement, Probe Number = 3, T = 31.178000 C 09:39:49 Temperature Measurement, Probe Number = 4, T = 14.096000 C 09:39:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.646367 V 09:39:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.646367 (V, A, ohm, ...), Measured Value = 123.477503 (C, atm, Hz, ...) 09:39:51 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158415 V 09:39:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158415 (V, A, ohm, ...), Measured Value = 11.881147 (C, atm, Hz, ...) 09:39:51 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001145 V 09:39:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001145 (V, A, ohm, ...), Measured Value = 1.144592 (C, atm, Hz, ...) 09:39:51 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.56 P2 = Core_Top, Value = 21.03 P3 = Top_Coil, Value = 24.52 P4 = H20 In, Value = 27.39 P5 = H20 Out, Value = 31.18 P6 = Ambient, Value = 14.10 P7 = Supply Pres(psi), Value = 123.48 P8 = Return Pres(psi), Value = 11.88 P9 = Flow Rate(gpm), Value = 1.14 09:40:52 Magnet Current for MAIN, Imag = 149.9725 A Vtrans = 1.499723 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:40:53 Main (V) Voltage Measurement, V = 10.556461 V 09:40:57 Temperature Measurement, Probe Number = 0, T = 21.047000 C 09:40:57 Temperature Measurement, Probe Number = 1, T = 24.668000 C 09:40:58 Temperature Measurement, Probe Number = 2, T = 27.404000 C 09:40:59 Temperature Measurement, Probe Number = 3, T = 31.288000 C 09:40:59 Temperature Measurement, Probe Number = 4, T = 14.112000 C 09:41:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.660244 V 09:41:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660244 (V, A, ohm, ...), Measured Value = 124.518330 (C, atm, Hz, ...) 09:41:00 Sensor Voltage Measurement, Sensor Number = 1, V = 1.161127 V 09:41:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.161127 (V, A, ohm, ...), Measured Value = 12.084555 (C, atm, Hz, ...) 09:41:01 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001184 V 09:41:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001184 (V, A, ohm, ...), Measured Value = 1.184283 (C, atm, Hz, ...) 09:41:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.56 P2 = Core_Top, Value = 21.05 P3 = Top_Coil, Value = 24.67 P4 = H20 In, Value = 27.40 P5 = H20 Out, Value = 31.29 P6 = Ambient, Value = 14.11 P7 = Supply Pres(psi), Value = 124.52 P8 = Return Pres(psi), Value = 12.08 P9 = Flow Rate(gpm), Value = 1.18 09:42:02 Magnet Current for MAIN, Imag = 149.9736 A Vtrans = 1.499734 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:42:03 Main (V) Voltage Measurement, V = 10.557070 V 09:42:06 Temperature Measurement, Probe Number = 0, T = 21.072000 C 09:42:07 Temperature Measurement, Probe Number = 1, T = 24.777000 C 09:42:08 Temperature Measurement, Probe Number = 2, T = 27.408000 C 09:42:08 Temperature Measurement, Probe Number = 3, T = 31.367000 C 09:42:09 Temperature Measurement, Probe Number = 4, T = 14.162000 C 09:42:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.664471 V 09:42:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664471 (V, A, ohm, ...), Measured Value = 124.835333 (C, atm, Hz, ...) 09:42:10 Sensor Voltage Measurement, Sensor Number = 1, V = 1.160271 V 09:42:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.160271 (V, A, ohm, ...), Measured Value = 12.020317 (C, atm, Hz, ...) 09:42:11 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001195 V 09:42:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001195 (V, A, ohm, ...), Measured Value = 1.194961 (C, atm, Hz, ...) 09:42:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.56 P2 = Core_Top, Value = 21.07 P3 = Top_Coil, Value = 24.78 P4 = H20 In, Value = 27.41 P5 = H20 Out, Value = 31.37 P6 = Ambient, Value = 14.16 P7 = Supply Pres(psi), Value = 124.84 P8 = Return Pres(psi), Value = 12.02 P9 = Flow Rate(gpm), Value = 1.19 09:43:12 Magnet Current for MAIN, Imag = 149.9728 A Vtrans = 1.499726 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:43:13 Main (V) Voltage Measurement, V = 10.557352 V 09:43:16 Temperature Measurement, Probe Number = 0, T = 21.117000 C 09:43:17 Temperature Measurement, Probe Number = 1, T = 24.864000 C 09:43:18 Temperature Measurement, Probe Number = 2, T = 27.425000 C 09:43:18 Temperature Measurement, Probe Number = 3, T = 31.425000 C 09:43:19 Temperature Measurement, Probe Number = 4, T = 14.168000 C 09:43:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.637391 V 09:43:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.637391 (V, A, ohm, ...), Measured Value = 122.804348 (C, atm, Hz, ...) 09:43:20 Sensor Voltage Measurement, Sensor Number = 1, V = 1.160170 V 09:43:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.160170 (V, A, ohm, ...), Measured Value = 12.012727 (C, atm, Hz, ...) 09:43:21 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001195 V 09:43:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001195 (V, A, ohm, ...), Measured Value = 1.194976 (C, atm, Hz, ...) 09:43:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.56 P2 = Core_Top, Value = 21.12 P3 = Top_Coil, Value = 24.86 P4 = H20 In, Value = 27.43 P5 = H20 Out, Value = 31.43 P6 = Ambient, Value = 14.17 P7 = Supply Pres(psi), Value = 122.80 P8 = Return Pres(psi), Value = 12.01 P9 = Flow Rate(gpm), Value = 1.19 09:44:22 Magnet Current for MAIN, Imag = 149.9737 A Vtrans = 1.499735 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:44:22 Main (V) Voltage Measurement, V = 10.557817 V 09:44:26 Temperature Measurement, Probe Number = 0, T = 21.139000 C 09:44:27 Temperature Measurement, Probe Number = 1, T = 24.858000 C 09:44:27 Temperature Measurement, Probe Number = 2, T = 27.424000 C 09:44:28 Temperature Measurement, Probe Number = 3, T = 31.463000 C 09:44:29 Temperature Measurement, Probe Number = 4, T = 14.160000 C 09:44:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.643486 V 09:44:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.643486 (V, A, ohm, ...), Measured Value = 123.261450 (C, atm, Hz, ...) 09:44:30 Sensor Voltage Measurement, Sensor Number = 1, V = 1.160714 V 09:44:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.160714 (V, A, ohm, ...), Measured Value = 12.053558 (C, atm, Hz, ...) 09:44:31 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001184 V 09:44:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001184 (V, A, ohm, ...), Measured Value = 1.184164 (C, atm, Hz, ...) 09:44:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.56 P2 = Core_Top, Value = 21.14 P3 = Top_Coil, Value = 24.86 P4 = H20 In, Value = 27.42 P5 = H20 Out, Value = 31.46 P6 = Ambient, Value = 14.16 P7 = Supply Pres(psi), Value = 123.26 P8 = Return Pres(psi), Value = 12.05 P9 = Flow Rate(gpm), Value = 1.18 09:44:31 Magnet system MAIN current ramping to 0.0000 A... 09:45:06 Magnet system MAIN current ramping to 150.0000 A... 09:45:42 Magnet system MAIN current ramping to 0.0000 A... 09:46:17 Magnet system MAIN current ramping to 150.0000 A... 09:46:53 Magnet system MAIN current ramping to 0.0000 A... 09:47:28 Magnet system MAIN current ramping to 150.0000 A... 09:48:04 Magnet system MAIN current ramping to 0.0000 A... 09:48:42 Position moved: 0.000000 m 09:48:44 Magnet system MAIN current ramping to 150.0000 A... 09:49:20 Magnet Current for MAIN, Imag = 149.9737 A Vtrans = 1.499735 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:49:21 Main (V) Voltage Measurement, V = 10.529549 V 09:49:25 Temperature Measurement, Probe Number = 0, T = 21.212000 C 09:49:25 Temperature Measurement, Probe Number = 1, T = 24.607000 C 09:49:26 Temperature Measurement, Probe Number = 2, T = 27.419000 C 09:49:27 Temperature Measurement, Probe Number = 3, T = 28.668000 C 09:49:27 Temperature Measurement, Probe Number = 4, T = 14.283000 C 09:49:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.658224 V 09:49:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658224 (V, A, ohm, ...), Measured Value = 124.366800 (C, atm, Hz, ...) 09:49:28 Sensor Voltage Measurement, Sensor Number = 1, V = 1.162165 V 09:49:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.162165 (V, A, ohm, ...), Measured Value = 12.162382 (C, atm, Hz, ...) 09:49:29 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001184 V 09:49:29 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001184 (V, A, ohm, ...), Measured Value = 1.184266 (C, atm, Hz, ...) 09:49:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.53 P2 = Core_Top, Value = 21.21 P3 = Top_Coil, Value = 24.61 P4 = H20 In, Value = 27.42 P5 = H20 Out, Value = 28.67 P6 = Ambient, Value = 14.28 P7 = Supply Pres(psi), Value = 124.37 P8 = Return Pres(psi), Value = 12.16 P9 = Flow Rate(gpm), Value = 1.18 09:49:29 Magnetic Field Measurement Measuring the magnet strength... 09:49:29 Integrated Voltage Measurement... 09:49:30 Magnet Current for MAIN, Imag = 149.9731 A Vtrans = 1.499729 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:49:38 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012945400 Vs 09:49:45 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012953540 Vs 09:49:46 Magnet Current for MAIN, Imag = 149.9712 A Vtrans = 1.499710 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:49:53 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012962029 Vs 09:50:00 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012955769 Vs 09:50:01 Magnet Current for MAIN, Imag = 149.9731 A Vtrans = 1.499729 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:50:08 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012955521 Vs 09:50:15 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012953576 Vs 09:50:16 Magnet Current for MAIN, Imag = 149.9732 A Vtrans = 1.499730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:50:23 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012960381 Vs 09:50:30 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012950238 Vs 09:50:31 Magnet Current for MAIN, Imag = 149.9752 A Vtrans = 1.499750 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:50:38 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012956905 Vs 09:50:45 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012952773 Vs 09:50:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012954613 +- 0.000003012 Vs 09:50:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0125000 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.012954613 +- 0.000003012 Vs BL = -0.20727381 +- 0.00004819 Tm 09:50:45 Integrated Voltage Measurement... 09:50:46 Magnet Current for MAIN, Imag = 149.9735 A Vtrans = 1.499733 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:50:54 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006488888 Vs 09:51:01 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006482849 Vs 09:51:02 Magnet Current for MAIN, Imag = 149.9725 A Vtrans = 1.499723 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:51:09 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006489338 Vs 09:51:16 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006483868 Vs 09:51:17 Magnet Current for MAIN, Imag = 149.9728 A Vtrans = 1.499726 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:51:24 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006486771 Vs 09:51:31 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006483516 Vs 09:51:32 Magnet Current for MAIN, Imag = 149.9726 A Vtrans = 1.499724 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:51:39 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006483361 Vs 09:51:46 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006483271 Vs 09:51:47 Magnet Current for MAIN, Imag = 149.9727 A Vtrans = 1.499725 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:51:54 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006481257 Vs 09:52:01 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006483048 Vs 09:52:01 Integrated Voltage Average and RMS of Measurements X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006484617 +- 0.000001646 Vs 09:52:01 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.006484617 +- 0.000001646 Vs BL = -0.10375387 +- 0.00002634 Tm 09:52:01 Integrated Voltage Measurement... 09:52:02 Magnet Current for MAIN, Imag = 149.9752 A Vtrans = 1.499750 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:52:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000002574 Vs 09:52:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000008575 Vs 09:52:18 Magnet Current for MAIN, Imag = 149.9743 A Vtrans = 1.499742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:52:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004932 Vs 09:52:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004882 Vs 09:52:33 Magnet Current for MAIN, Imag = 149.9784 A Vtrans = 1.499783 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:52:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000007352 Vs 09:52:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006762 Vs 09:52:48 Magnet Current for MAIN, Imag = 149.9742 A Vtrans = 1.499740 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:52:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003840 Vs 09:53:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006436 Vs 09:53:03 Magnet Current for MAIN, Imag = 149.9713 A Vtrans = 1.499712 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:53:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000002941 Vs 09:53:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004724 Vs 09:53:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005302 +- 0.000001049 Vs 09:53:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000005302 +- 0.000001049 Vs BL = 0.00008483 +- 0.00001678 Tm 09:53:17 Integrated Voltage Measurement... 09:53:18 Magnet Current for MAIN, Imag = 149.9707 A Vtrans = 1.499705 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:53:26 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006493987 Vs 09:53:33 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006498452 Vs 09:53:34 Magnet Current for MAIN, Imag = 149.9749 A Vtrans = 1.499748 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:53:41 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006494855 Vs 09:53:48 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006501437 Vs 09:53:49 Magnet Current for MAIN, Imag = 149.9728 A Vtrans = 1.499726 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:53:56 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006495446 Vs 09:54:03 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006492508 Vs 09:54:04 Magnet Current for MAIN, Imag = 149.9741 A Vtrans = 1.499739 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:54:11 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006496688 Vs 09:54:18 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006492662 Vs 09:54:19 Magnet Current for MAIN, Imag = 149.9726 A Vtrans = 1.499724 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:54:26 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006496454 Vs 09:54:33 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006499881 Vs 09:54:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006496237 +- 0.000001727 Vs 09:54:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.006496237 +- 0.000001727 Vs BL = 0.10393979 +- 0.00002764 Tm 09:54:33 Integrated Voltage Measurement... 09:54:34 Magnet Current for MAIN, Imag = 149.9737 A Vtrans = 1.499735 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:54:42 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012975624 Vs 09:54:49 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012972528 Vs 09:54:50 Magnet Current for MAIN, Imag = 149.9832 A Vtrans = 1.499830 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:54:57 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012973710 Vs 09:55:04 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012975749 Vs 09:55:05 Magnet Current for MAIN, Imag = 149.9720 A Vtrans = 1.499718 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:55:12 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012970307 Vs 09:55:19 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012970872 Vs 09:55:19 Magnet Current for MAIN, Imag = 149.9742 A Vtrans = 1.499740 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:55:27 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012970946 Vs 09:55:34 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012971159 Vs 09:55:34 Magnet Current for MAIN, Imag = 149.9746 A Vtrans = 1.499744 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:55:41 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012969898 Vs 09:55:49 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012977570 Vs 09:55:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012972836 +- 0.000001683 Vs 09:55:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0125000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.012972836 +- 0.000001683 Vs BL = 0.20756538 +- 0.00002692 Tm 09:55:53 Position moved: 0.000000 m 09:55:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00011 0.00001 1 16.59795 0.00187 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0125000 -0.20727 0.00005 -0.20736 0.00009 -0.0062500 -0.10375 0.00003 -0.10362 -0.00013 0.0000000 0.00008 0.00002 0.00011 -0.00003 0.0062500 0.10394 0.00003 0.10385 0.00009 0.0125000 0.20757 0.00003 0.20759 -0.00002 09:55:53 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0125 -0.20727 0.00005 -0.0063 -0.10375 0.00003 0.0000 0.00008 0.00002 0.0063 0.10394 0.00003 0.0125 0.20757 0.00003 SL = 16.5979527 +- 0.0018692 Tm^2/m^n 09:55:53 Quadrupole Strength Calculation Check Slope = 16.597953 Tm/m, Inter = 0.000112 Tm, Sig_slope = 0.005370 Tm/m, Est_sig = 0.000106 Tm GL = 16.597953 +- 0.005370 T 09:55:53 Magnet Strength Measurement Harmonic Number = 2 SL = 16.5979527 +- 0.0018692 Tm^2/m^n 09:55:55 Position moved: 0.000000 m 09:55:56 Magnet Current for MAIN, Imag = 149.9731 A Vtrans = 1.499729 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:55:57 Main (V) Voltage Measurement, V = 10.559710 V 09:56:01 Temperature Measurement, Probe Number = 0, T = 21.391000 C 09:56:01 Temperature Measurement, Probe Number = 1, T = 25.128000 C 09:56:02 Temperature Measurement, Probe Number = 2, T = 27.443000 C 09:56:02 Temperature Measurement, Probe Number = 3, T = 31.499000 C 09:56:03 Temperature Measurement, Probe Number = 4, T = 14.356000 C 09:56:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.649998 V 09:56:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.649998 (V, A, ohm, ...), Measured Value = 123.749835 (C, atm, Hz, ...) 09:56:04 Sensor Voltage Measurement, Sensor Number = 1, V = 1.160728 V 09:56:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.160728 (V, A, ohm, ...), Measured Value = 12.054592 (C, atm, Hz, ...) 09:56:05 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001184 V 09:56:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001184 (V, A, ohm, ...), Measured Value = 1.183798 (C, atm, Hz, ...) 09:56:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.56 P2 = Core_Top, Value = 21.39 P3 = Top_Coil, Value = 25.13 P4 = H20 In, Value = 27.44 P5 = H20 Out, Value = 31.50 P6 = Ambient, Value = 14.36 P7 = Supply Pres(psi), Value = 123.75 P8 = Return Pres(psi), Value = 12.05 P9 = Flow Rate(gpm), Value = 1.18 09:56:06 Magnet Current for MAIN, Imag = 149.9753 A Vtrans = 1.499751 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:56:06 Main (V) Voltage Measurement, V = 10.559009 V 09:56:10 Temperature Measurement, Probe Number = 0, T = 21.389000 C 09:56:11 Temperature Measurement, Probe Number = 1, T = 25.138000 C 09:56:11 Temperature Measurement, Probe Number = 2, T = 27.445000 C 09:56:12 Temperature Measurement, Probe Number = 3, T = 31.505000 C 09:56:13 Temperature Measurement, Probe Number = 4, T = 14.362000 C 09:56:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.657968 V 09:56:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657968 (V, A, ohm, ...), Measured Value = 124.347600 (C, atm, Hz, ...) 09:56:14 Sensor Voltage Measurement, Sensor Number = 1, V = 1.160777 V 09:56:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.160777 (V, A, ohm, ...), Measured Value = 12.058245 (C, atm, Hz, ...) 09:56:14 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001162 V 09:56:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001162 (V, A, ohm, ...), Measured Value = 1.162269 (C, atm, Hz, ...) 09:56:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.98 P1 = Main (V), Value = 10.56 P2 = Core_Top, Value = 21.39 P3 = Top_Coil, Value = 25.14 P4 = H20 In, Value = 27.45 P5 = H20 Out, Value = 31.50 P6 = Ambient, Value = 14.36 P7 = Supply Pres(psi), Value = 124.35 P8 = Return Pres(psi), Value = 12.06 P9 = Flow Rate(gpm), Value = 1.16 09:56:15 Integrated Voltage Measurement... 09:56:15 Magnet Current for MAIN, Imag = 149.9740 A Vtrans = 1.499738 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:56:23 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012951329 Vs 09:56:31 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012951113 Vs 09:56:31 Magnet Current for MAIN, Imag = 149.9743 A Vtrans = 1.499742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:56:38 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012965368 Vs 09:56:46 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012949785 Vs 09:56:46 Magnet Current for MAIN, Imag = 149.9757 A Vtrans = 1.499755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:56:53 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012948693 Vs 09:57:00 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012953942 Vs 09:57:01 Magnet Current for MAIN, Imag = 149.9746 A Vtrans = 1.499744 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:57:08 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012961192 Vs 09:57:15 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012959230 Vs 09:57:16 Magnet Current for MAIN, Imag = 149.9772 A Vtrans = 1.499770 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:57:23 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012946257 Vs 09:57:30 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012949519 Vs 09:57:30 Integrated Voltage Average and RMS of Measurements X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012953643 +- 0.000004539 Vs 09:57:30 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0125000 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.012953643 +- 0.000004539 Vs BL = -0.20725829 +- 0.00007262 Tm Remeasure 09:57:30 Integrated Voltage Measurement... 09:57:31 Magnet Current for MAIN, Imag = 149.9796 A Vtrans = 1.499794 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:57:38 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012956661 Vs 09:57:45 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012956088 Vs 09:57:46 Magnet Current for MAIN, Imag = 149.9749 A Vtrans = 1.499748 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:57:53 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012959542 Vs 09:58:00 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012952776 Vs 09:58:01 Magnet Current for MAIN, Imag = 149.9732 A Vtrans = 1.499730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:58:08 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012952105 Vs 09:58:15 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012953095 Vs 09:58:16 Magnet Current for MAIN, Imag = 149.9740 A Vtrans = 1.499738 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:58:23 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012955116 Vs 09:58:30 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012956606 Vs 09:58:31 Magnet Current for MAIN, Imag = 149.9717 A Vtrans = 1.499715 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:58:38 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012951595 Vs 09:58:45 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012960218 Vs 09:58:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012955380 +- 0.000001402 Vs 09:58:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0125000 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.012955380 +- 0.000001402 Vs BL = -0.20728609 +- 0.00002244 Tm 09:58:45 Integrated Voltage Measurement... 09:58:46 Magnet Current for MAIN, Imag = 149.9741 A Vtrans = 1.499739 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:58:54 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006487130 Vs 09:59:01 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006482873 Vs 09:59:02 Magnet Current for MAIN, Imag = 149.9728 A Vtrans = 1.499726 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:59:09 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006483546 Vs 09:59:16 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006484749 Vs 09:59:17 Magnet Current for MAIN, Imag = 149.9747 A Vtrans = 1.499745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:59:24 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006490235 Vs 09:59:31 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006484245 Vs 09:59:31 Magnet Current for MAIN, Imag = 149.9767 A Vtrans = 1.499765 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:59:38 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006482197 Vs 09:59:45 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006484530 Vs 09:59:46 Magnet Current for MAIN, Imag = 149.9738 A Vtrans = 1.499737 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 09:59:53 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006477753 Vs 10:00:00 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006482227 Vs 10:00:00 Integrated Voltage Average and RMS of Measurements X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006483948 +- 0.000002366 Vs 10:00:00 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.006483948 +- 0.000002366 Vs BL = -0.10374317 +- 0.00003786 Tm Remeasure 10:00:00 Integrated Voltage Measurement... 10:00:01 Magnet Current for MAIN, Imag = 149.9718 A Vtrans = 1.499716 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:00:08 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006486584 Vs 10:00:15 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006483492 Vs 10:00:16 Magnet Current for MAIN, Imag = 149.9726 A Vtrans = 1.499724 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:00:23 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006480549 Vs 10:00:30 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006482607 Vs 10:00:31 Magnet Current for MAIN, Imag = 149.9743 A Vtrans = 1.499742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:00:38 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006488460 Vs 10:00:45 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006482957 Vs 10:00:46 Magnet Current for MAIN, Imag = 149.9742 A Vtrans = 1.499740 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:00:53 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006487516 Vs 10:01:00 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006484569 Vs 10:01:01 Magnet Current for MAIN, Imag = 149.9705 A Vtrans = 1.499703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:01:08 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006487950 Vs 10:01:15 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006486106 Vs 10:01:15 Integrated Voltage Average and RMS of Measurements X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006485079 +- 0.000001864 Vs 10:01:15 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.006485079 +- 0.000001864 Vs BL = -0.10376126 +- 0.00002983 Tm Remeasure 10:01:15 Integrated Voltage Measurement... 10:01:16 Magnet Current for MAIN, Imag = 149.9732 A Vtrans = 1.499730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:01:23 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006487440 Vs 10:01:30 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006485856 Vs 10:01:31 Magnet Current for MAIN, Imag = 149.9737 A Vtrans = 1.499735 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:01:38 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006484987 Vs 10:01:45 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006484321 Vs 10:01:46 Magnet Current for MAIN, Imag = 149.9732 A Vtrans = 1.499730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:01:53 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006482398 Vs 10:02:00 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006481919 Vs 10:02:00 Magnet Current for MAIN, Imag = 149.9732 A Vtrans = 1.499730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:02:08 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006482814 Vs 10:02:15 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006485055 Vs 10:02:15 Magnet Current for MAIN, Imag = 149.9771 A Vtrans = 1.499769 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:02:22 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006486026 Vs 10:02:30 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006484078 Vs 10:02:30 Integrated Voltage Average and RMS of Measurements X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006484489 +- 0.000001466 Vs 10:02:30 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.006484489 +- 0.000001466 Vs BL = -0.10375183 +- 0.00002346 Tm 10:02:30 Integrated Voltage Measurement... 10:02:31 Magnet Current for MAIN, Imag = 149.9757 A Vtrans = 1.499755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:02:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000002543 Vs 10:02:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006157 Vs 10:02:47 Magnet Current for MAIN, Imag = 149.9889 A Vtrans = 1.499888 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:02:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004766 Vs 10:03:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004566 Vs 10:03:02 Magnet Current for MAIN, Imag = 149.9732 A Vtrans = 1.499730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:03:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004591 Vs 10:03:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006550 Vs 10:03:16 Magnet Current for MAIN, Imag = 149.9752 A Vtrans = 1.499750 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:03:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000007169 Vs 10:03:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000002669 Vs 10:03:31 Magnet Current for MAIN, Imag = 149.9723 A Vtrans = 1.499721 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:03:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004533 Vs 10:03:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000003300 Vs 10:03:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004684 +- 0.000000555 Vs 10:03:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000004684 +- 0.000000555 Vs BL = 0.00007495 +- 0.00000889 Tm Remeasure 10:03:45 Integrated Voltage Measurement... 10:03:46 Magnet Current for MAIN, Imag = 149.9866 A Vtrans = 1.499864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:03:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000006051 Vs 10:04:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000007972 Vs 10:04:01 Magnet Current for MAIN, Imag = 149.9731 A Vtrans = 1.499729 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:04:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004610 Vs 10:04:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004579 Vs 10:04:16 Magnet Current for MAIN, Imag = 149.9735 A Vtrans = 1.499733 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:04:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000006322 Vs 10:04:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004801 Vs 10:04:31 Magnet Current for MAIN, Imag = 149.9742 A Vtrans = 1.499740 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:04:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003675 Vs 10:04:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000007623 Vs 10:04:45 Magnet Current for MAIN, Imag = 149.9721 A Vtrans = 1.499719 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:04:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005735 Vs 10:05:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006616 Vs 10:05:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005798 +- 0.000000793 Vs 10:05:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000005798 +- 0.000000793 Vs BL = 0.00009277 +- 0.00001268 Tm Remeasure 10:05:00 Integrated Voltage Measurement... 10:05:00 Magnet Current for MAIN, Imag = 149.9754 A Vtrans = 1.499753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:05:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003491 Vs 10:05:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000007522 Vs 10:05:15 Magnet Current for MAIN, Imag = 149.9738 A Vtrans = 1.499737 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:05:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004618 Vs 10:05:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004348 Vs 10:05:30 Magnet Current for MAIN, Imag = 149.9743 A Vtrans = 1.499742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:05:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004159 Vs 10:05:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000005069 Vs 10:05:45 Magnet Current for MAIN, Imag = 149.9723 A Vtrans = 1.499721 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:05:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000006927 Vs 10:05:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000005408 Vs 10:06:00 Magnet Current for MAIN, Imag = 149.9738 A Vtrans = 1.499737 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:06:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003301 Vs 10:06:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000008607 Vs 10:06:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005345 +- 0.000000686 Vs 10:06:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000005345 +- 0.000000686 Vs BL = 0.00008552 +- 0.00001097 Tm Remeasure 10:06:14 Integrated Voltage Measurement... 10:06:15 Magnet Current for MAIN, Imag = 149.9741 A Vtrans = 1.499739 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:06:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003833 Vs 10:06:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006429 Vs 10:06:30 Magnet Current for MAIN, Imag = 149.9748 A Vtrans = 1.499747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:06:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003879 Vs 10:06:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000007955 Vs 10:06:45 Magnet Current for MAIN, Imag = 149.9748 A Vtrans = 1.499747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:06:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005630 Vs 10:06:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000008097 Vs 10:07:00 Magnet Current for MAIN, Imag = 149.9746 A Vtrans = 1.499744 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:07:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004130 Vs 10:07:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000005475 Vs 10:07:15 Magnet Current for MAIN, Imag = 149.9733 A Vtrans = 1.499731 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:07:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004542 Vs 10:07:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000008268 Vs 10:07:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005824 +- 0.000000768 Vs 10:07:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000005824 +- 0.000000768 Vs BL = 0.00009318 +- 0.00001229 Tm 10:07:29 Integrated Voltage Measurement... 10:07:30 Magnet Current for MAIN, Imag = 149.9721 A Vtrans = 1.499719 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:07:38 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006495189 Vs 10:07:45 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006498155 Vs 10:07:46 Magnet Current for MAIN, Imag = 149.9707 A Vtrans = 1.499705 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:07:53 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006493911 Vs 10:08:00 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006495753 Vs 10:08:01 Magnet Current for MAIN, Imag = 149.9742 A Vtrans = 1.499740 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:08:08 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006495002 Vs 10:08:15 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006493681 Vs 10:08:16 Magnet Current for MAIN, Imag = 149.9742 A Vtrans = 1.499740 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:08:22 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006492195 Vs 10:08:29 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006495853 Vs 10:08:30 Magnet Current for MAIN, Imag = 149.9783 A Vtrans = 1.499782 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:08:37 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006493791 Vs 10:08:44 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006493706 Vs 10:08:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006494724 +- 0.000001039 Vs 10:08:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.006494724 +- 0.000001039 Vs BL = 0.10391558 +- 0.00001662 Tm 10:08:44 Integrated Voltage Measurement... 10:08:45 Magnet Current for MAIN, Imag = 149.9783 A Vtrans = 1.499782 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:08:53 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012965810 Vs 10:09:00 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012971512 Vs 10:09:01 Magnet Current for MAIN, Imag = 149.9743 A Vtrans = 1.499742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:09:08 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012972277 Vs 10:09:15 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012971849 Vs 10:09:16 Magnet Current for MAIN, Imag = 149.9754 A Vtrans = 1.499753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:09:23 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012969211 Vs 10:09:30 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012979250 Vs 10:09:30 Magnet Current for MAIN, Imag = 149.9749 A Vtrans = 1.499748 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:09:37 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012971054 Vs 10:09:44 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012972942 Vs 10:09:45 Magnet Current for MAIN, Imag = 149.9754 A Vtrans = 1.499753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:09:52 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012972968 Vs 10:09:59 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012969450 Vs 10:09:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012971632 +- 0.000001793 Vs 10:09:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0125000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.012971632 +- 0.000001793 Vs BL = 0.20754612 +- 0.00002869 Tm 10:10:03 Position moved: 0.000000 m 10:10:04 Magnet Current for MAIN, Imag = 149.9708 A Vtrans = 1.499707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:10:05 Main (V) Voltage Measurement, V = 10.561765 V 10:10:08 Temperature Measurement, Probe Number = 0, T = 21.809000 C 10:10:09 Temperature Measurement, Probe Number = 1, T = 25.574000 C 10:10:10 Temperature Measurement, Probe Number = 2, T = 27.513000 C 10:10:10 Temperature Measurement, Probe Number = 3, T = 31.725000 C 10:10:11 Temperature Measurement, Probe Number = 4, T = 14.544000 C 10:10:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.657978 V 10:10:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657978 (V, A, ohm, ...), Measured Value = 124.348350 (C, atm, Hz, ...) 10:10:12 Sensor Voltage Measurement, Sensor Number = 1, V = 1.161629 V 10:10:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.161629 (V, A, ohm, ...), Measured Value = 12.122205 (C, atm, Hz, ...) 10:10:13 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001164 V 10:10:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001164 (V, A, ohm, ...), Measured Value = 1.164415 (C, atm, Hz, ...) 10:10:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.56 P2 = Core_Top, Value = 21.81 P3 = Top_Coil, Value = 25.57 P4 = H20 In, Value = 27.51 P5 = H20 Out, Value = 31.73 P6 = Ambient, Value = 14.54 P7 = Supply Pres(psi), Value = 124.35 P8 = Return Pres(psi), Value = 12.12 P9 = Flow Rate(gpm), Value = 1.16 10:10:13 Magnet system MAIN current ramping to 150.0000 A... 10:10:34 Magnet Current for MAIN, Imag = 149.9708 A Vtrans = 1.499707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:10:35 Main (V) Voltage Measurement, V = 10.562029 V 10:10:38 Temperature Measurement, Probe Number = 0, T = 21.807000 C 10:10:39 Temperature Measurement, Probe Number = 1, T = 25.600000 C 10:10:39 Temperature Measurement, Probe Number = 2, T = 27.518000 C 10:10:40 Temperature Measurement, Probe Number = 3, T = 31.723000 C 10:10:41 Temperature Measurement, Probe Number = 4, T = 14.543000 C 10:10:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.648909 V 10:10:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.648909 (V, A, ohm, ...), Measured Value = 123.668175 (C, atm, Hz, ...) 10:10:42 Sensor Voltage Measurement, Sensor Number = 1, V = 1.161754 V 10:10:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.161754 (V, A, ohm, ...), Measured Value = 12.131572 (C, atm, Hz, ...) 10:10:43 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001196 V 10:10:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001196 (V, A, ohm, ...), Measured Value = 1.195527 (C, atm, Hz, ...) 10:10:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.97 P1 = Main (V), Value = 10.56 P2 = Core_Top, Value = 21.81 P3 = Top_Coil, Value = 25.60 P4 = H20 In, Value = 27.52 P5 = H20 Out, Value = 31.72 P6 = Ambient, Value = 14.54 P7 = Supply Pres(psi), Value = 123.67 P8 = Return Pres(psi), Value = 12.13 P9 = Flow Rate(gpm), Value = 1.20 10:10:43 Integrated Voltage Measurement... 10:10:43 Magnet Current for MAIN, Imag = 149.9731 A Vtrans = 1.499729 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:10:51 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012946968 Vs 10:10:58 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012956800 Vs 10:10:59 Magnet Current for MAIN, Imag = 149.9738 A Vtrans = 1.499737 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:11:06 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012947646 Vs 10:11:13 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012951266 Vs 10:11:14 Magnet Current for MAIN, Imag = 149.9740 A Vtrans = 1.499738 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:11:21 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012949215 Vs 10:11:28 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012952340 Vs 10:11:29 Magnet Current for MAIN, Imag = 149.9764 A Vtrans = 1.499763 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:11:36 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012955353 Vs 10:11:43 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012951705 Vs 10:11:44 Magnet Current for MAIN, Imag = 149.9779 A Vtrans = 1.499778 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:11:51 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012965299 Vs 10:11:58 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012949592 Vs 10:11:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012952618 +- 0.000002759 Vs 10:11:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0125000 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.012952618 +- 0.000002759 Vs BL = -0.20724190 +- 0.00004414 Tm 10:11:58 Integrated Voltage Measurement... 10:11:59 Magnet Current for MAIN, Imag = 149.9749 A Vtrans = 1.499748 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:12:07 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006477887 Vs 10:12:14 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006484687 Vs 10:12:15 Magnet Current for MAIN, Imag = 149.9743 A Vtrans = 1.499742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:12:22 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006481845 Vs 10:12:29 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006488562 Vs 10:12:30 Magnet Current for MAIN, Imag = 149.9747 A Vtrans = 1.499745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:12:37 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006480800 Vs 10:12:44 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006483821 Vs 10:12:44 Magnet Current for MAIN, Imag = 149.9736 A Vtrans = 1.499734 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:12:52 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006491866 Vs 10:12:59 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006484991 Vs 10:12:59 Magnet Current for MAIN, Imag = 149.9720 A Vtrans = 1.499718 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:13:06 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006486754 Vs 10:13:14 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006485358 Vs 10:13:14 Integrated Voltage Average and RMS of Measurements X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006484657 +- 0.000002582 Vs 10:13:14 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.006484657 +- 0.000002582 Vs BL = -0.10375451 +- 0.00004132 Tm Remeasure 10:13:14 Integrated Voltage Measurement... 10:13:14 Magnet Current for MAIN, Imag = 149.9744 A Vtrans = 1.499743 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:13:21 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006484833 Vs 10:13:28 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006486407 Vs 10:13:29 Magnet Current for MAIN, Imag = 149.9728 A Vtrans = 1.499726 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:13:36 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006487526 Vs 10:13:44 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006484281 Vs 10:13:44 Magnet Current for MAIN, Imag = 149.9752 A Vtrans = 1.499750 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:13:51 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006493514 Vs 10:13:58 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006483073 Vs 10:13:59 Magnet Current for MAIN, Imag = 149.9761 A Vtrans = 1.499759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:14:06 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006479759 Vs 10:14:13 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006488138 Vs 10:14:14 Magnet Current for MAIN, Imag = 149.9747 A Vtrans = 1.499745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:14:21 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006484545 Vs 10:14:28 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006486473 Vs 10:14:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006485855 +- 0.000001397 Vs 10:14:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.006485855 +- 0.000001397 Vs BL = -0.10377368 +- 0.00002235 Tm 10:14:28 Integrated Voltage Measurement... 10:14:29 Magnet Current for MAIN, Imag = 149.9766 A Vtrans = 1.499764 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:14:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000002215 Vs 10:14:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006219 Vs 10:14:45 Magnet Current for MAIN, Imag = 149.9744 A Vtrans = 1.499743 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:14:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003781 Vs 10:14:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006138 Vs 10:15:00 Magnet Current for MAIN, Imag = 149.9774 A Vtrans = 1.499773 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:15:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000007937 Vs 10:15:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000005424 Vs 10:15:14 Magnet Current for MAIN, Imag = 149.9754 A Vtrans = 1.499753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:15:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000006061 Vs 10:15:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004564 Vs 10:15:29 Magnet Current for MAIN, Imag = 149.9751 A Vtrans = 1.499749 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:15:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005717 Vs 10:15:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000007509 Vs 10:15:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005556 +- 0.000000958 Vs 10:15:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000005556 +- 0.000000958 Vs BL = 0.00008890 +- 0.00001533 Tm Remeasure 10:15:44 Integrated Voltage Measurement... 10:15:44 Magnet Current for MAIN, Imag = 149.9766 A Vtrans = 1.499764 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:15:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004468 Vs 10:15:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006946 Vs 10:15:59 Magnet Current for MAIN, Imag = 149.9741 A Vtrans = 1.499739 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:16:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000002880 Vs 10:16:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000007126 Vs 10:16:14 Magnet Current for MAIN, Imag = 149.9757 A Vtrans = 1.499755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:16:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004207 Vs 10:16:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006402 Vs 10:16:29 Magnet Current for MAIN, Imag = 149.9748 A Vtrans = 1.499747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:16:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000002226 Vs 10:16:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000003610 Vs 10:16:44 Magnet Current for MAIN, Imag = 149.9747 A Vtrans = 1.499745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:16:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000006338 Vs 10:16:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006690 Vs 10:16:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005089 +- 0.000001198 Vs 10:16:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000005089 +- 0.000001198 Vs BL = 0.00008143 +- 0.00001917 Tm Remeasure 10:16:58 Integrated Voltage Measurement... 10:16:59 Magnet Current for MAIN, Imag = 149.9756 A Vtrans = 1.499754 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:17:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004985 Vs 10:17:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004649 Vs 10:17:14 Magnet Current for MAIN, Imag = 149.9754 A Vtrans = 1.499753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:17:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004201 Vs 10:17:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006612 Vs 10:17:29 Magnet Current for MAIN, Imag = 149.9754 A Vtrans = 1.499753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:17:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000006679 Vs 10:17:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004711 Vs 10:17:44 Magnet Current for MAIN, Imag = 149.9784 A Vtrans = 1.499783 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:17:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004915 Vs 10:17:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000003520 Vs 10:17:59 Magnet Current for MAIN, Imag = 149.9726 A Vtrans = 1.499724 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:18:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000002711 Vs 10:18:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000007294 Vs 10:18:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005028 +- 0.000000508 Vs 10:18:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000005028 +- 0.000000508 Vs BL = 0.00008044 +- 0.00000813 Tm Remeasure 10:18:13 Integrated Voltage Measurement... 10:18:14 Magnet Current for MAIN, Imag = 149.9759 A Vtrans = 1.499758 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:18:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005392 Vs 10:18:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004051 Vs 10:18:29 Magnet Current for MAIN, Imag = 149.9763 A Vtrans = 1.499761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:18:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000007207 Vs 10:18:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000003906 Vs 10:18:44 Magnet Current for MAIN, Imag = 149.9772 A Vtrans = 1.499770 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:18:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003406 Vs 10:18:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004229 Vs 10:18:58 Magnet Current for MAIN, Imag = 149.9746 A Vtrans = 1.499744 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:19:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004370 Vs 10:19:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000003149 Vs 10:19:13 Magnet Current for MAIN, Imag = 149.9740 A Vtrans = 1.499738 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:19:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004189 Vs 10:19:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000005134 Vs 10:19:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004503 +- 0.000000664 Vs 10:19:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000004503 +- 0.000000664 Vs BL = 0.00007205 +- 0.00001063 Tm 10:19:28 Integrated Voltage Measurement... 10:19:28 Magnet Current for MAIN, Imag = 149.9767 A Vtrans = 1.499765 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:19:37 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006492706 Vs 10:19:44 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006494610 Vs 10:19:44 Magnet Current for MAIN, Imag = 149.9767 A Vtrans = 1.499765 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:19:51 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006492515 Vs 10:19:58 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006495666 Vs 10:19:59 Magnet Current for MAIN, Imag = 149.9746 A Vtrans = 1.499744 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:20:06 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006493955 Vs 10:20:13 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006500858 Vs 10:20:14 Magnet Current for MAIN, Imag = 149.9747 A Vtrans = 1.499745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:20:21 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006491853 Vs 10:20:28 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006492615 Vs 10:20:29 Magnet Current for MAIN, Imag = 149.9757 A Vtrans = 1.499755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:20:36 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006496903 Vs 10:20:43 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006497897 Vs 10:20:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006494958 +- 0.000002089 Vs 10:20:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.006494958 +- 0.000002089 Vs BL = 0.10391933 +- 0.00003343 Tm Remeasure 10:20:43 Integrated Voltage Measurement... 10:20:44 Magnet Current for MAIN, Imag = 149.9744 A Vtrans = 1.499743 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:20:51 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006494200 Vs 10:20:58 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006495859 Vs 10:20:59 Magnet Current for MAIN, Imag = 149.9767 A Vtrans = 1.499765 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:21:06 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006493122 Vs 10:21:13 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006497540 Vs 10:21:14 Magnet Current for MAIN, Imag = 149.9797 A Vtrans = 1.499795 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:21:22 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006494684 Vs 10:21:29 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006499827 Vs 10:21:29 Magnet Current for MAIN, Imag = 149.9752 A Vtrans = 1.499750 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:21:36 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006493571 Vs 10:21:43 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006490008 Vs 10:21:44 Magnet Current for MAIN, Imag = 149.9752 A Vtrans = 1.499750 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:21:51 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006492337 Vs 10:21:58 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006491702 Vs 10:21:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006494285 +- 0.000002090 Vs 10:21:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.006494285 +- 0.000002090 Vs BL = 0.10390856 +- 0.00003343 Tm Remeasure 10:21:58 Integrated Voltage Measurement... 10:21:59 Magnet Current for MAIN, Imag = 149.9754 A Vtrans = 1.499753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:22:06 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006492941 Vs 10:22:13 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006500686 Vs 10:22:14 Magnet Current for MAIN, Imag = 149.9754 A Vtrans = 1.499753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:22:21 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006496635 Vs 10:22:28 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006497426 Vs 10:22:29 Magnet Current for MAIN, Imag = 149.9757 A Vtrans = 1.499755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:22:36 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006494217 Vs 10:22:43 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006500092 Vs 10:22:43 Magnet Current for MAIN, Imag = 149.9757 A Vtrans = 1.499755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:22:50 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006494632 Vs 10:22:58 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006492717 Vs 10:22:58 Magnet Current for MAIN, Imag = 149.9763 A Vtrans = 1.499761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:23:05 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006493033 Vs 10:23:12 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006496866 Vs 10:23:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006495924 +- 0.000001381 Vs 10:23:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.006495924 +- 0.000001381 Vs BL = 0.10393479 +- 0.00002210 Tm 10:23:12 Integrated Voltage Measurement... 10:23:13 Magnet Current for MAIN, Imag = 149.9752 A Vtrans = 1.499750 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:23:21 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012971574 Vs 10:23:28 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012968070 Vs 10:23:29 Magnet Current for MAIN, Imag = 149.9771 A Vtrans = 1.499769 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:23:36 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012973875 Vs 10:23:43 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012981270 Vs 10:23:44 Magnet Current for MAIN, Imag = 149.9759 A Vtrans = 1.499758 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:23:51 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012966615 Vs 10:23:58 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012961119 Vs 10:23:59 Magnet Current for MAIN, Imag = 149.9743 A Vtrans = 1.499742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:24:06 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012973095 Vs 10:24:13 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012975515 Vs 10:24:14 Magnet Current for MAIN, Imag = 149.9788 A Vtrans = 1.499786 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:24:21 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012971228 Vs 10:24:28 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012972704 Vs 10:24:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012971507 +- 0.000004605 Vs 10:24:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0125000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.012971507 +- 0.000004605 Vs BL = 0.20754411 +- 0.00007368 Tm Remeasure 10:24:28 Integrated Voltage Measurement... 10:24:29 Magnet Current for MAIN, Imag = 149.9757 A Vtrans = 1.499755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:24:36 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012970946 Vs 10:24:43 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012979158 Vs 10:24:44 Magnet Current for MAIN, Imag = 149.9751 A Vtrans = 1.499749 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:24:51 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012968770 Vs 10:24:58 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012968668 Vs 10:24:59 Magnet Current for MAIN, Imag = 149.9766 A Vtrans = 1.499764 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:25:06 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012973255 Vs 10:25:13 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012981174 Vs 10:25:14 Magnet Current for MAIN, Imag = 149.9743 A Vtrans = 1.499742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:25:21 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012970040 Vs 10:25:28 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012970160 Vs 10:25:28 Magnet Current for MAIN, Imag = 149.9754 A Vtrans = 1.499753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:25:35 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012970947 Vs 10:25:42 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012974221 Vs 10:25:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012972734 +- 0.000003115 Vs 10:25:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0125000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.012972734 +- 0.000003115 Vs BL = 0.20756375 +- 0.00004985 Tm 10:25:46 Position moved: 0.000000 m 10:25:47 Magnet Current for MAIN, Imag = 149.9753 A Vtrans = 1.499751 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:25:48 Main (V) Voltage Measurement, V = 10.565914 V 10:25:51 Temperature Measurement, Probe Number = 0, T = 22.153000 C 10:25:52 Temperature Measurement, Probe Number = 1, T = 25.834000 C 10:25:53 Temperature Measurement, Probe Number = 2, T = 27.600000 C 10:25:53 Temperature Measurement, Probe Number = 3, T = 31.841000 C 10:25:54 Temperature Measurement, Probe Number = 4, T = 14.825000 C 10:25:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.632931 V 10:25:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.632931 (V, A, ohm, ...), Measured Value = 122.469825 (C, atm, Hz, ...) 10:25:55 Sensor Voltage Measurement, Sensor Number = 1, V = 1.163539 V 10:25:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.163539 (V, A, ohm, ...), Measured Value = 12.265395 (C, atm, Hz, ...) 10:25:56 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001184 V 10:25:56 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001184 (V, A, ohm, ...), Measured Value = 1.183761 (C, atm, Hz, ...) 10:25:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.98 P1 = Main (V), Value = 10.57 P2 = Core_Top, Value = 22.15 P3 = Top_Coil, Value = 25.83 P4 = H20 In, Value = 27.60 P5 = H20 Out, Value = 31.84 P6 = Ambient, Value = 14.82 P7 = Supply Pres(psi), Value = 122.47 P8 = Return Pres(psi), Value = 12.27 P9 = Flow Rate(gpm), Value = 1.18 10:25:56 Magnet system MAIN current ramping to 150.0000 A... 10:26:17 Magnet Current for MAIN, Imag = 149.9772 A Vtrans = 1.499770 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:26:18 Main (V) Voltage Measurement, V = 10.565940 V 10:26:21 Temperature Measurement, Probe Number = 0, T = 22.161000 C 10:26:22 Temperature Measurement, Probe Number = 1, T = 25.840000 C 10:26:23 Temperature Measurement, Probe Number = 2, T = 27.603000 C 10:26:23 Temperature Measurement, Probe Number = 3, T = 31.838000 C 10:26:24 Temperature Measurement, Probe Number = 4, T = 14.825000 C 10:26:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.638670 V 10:26:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.638670 (V, A, ohm, ...), Measured Value = 122.900243 (C, atm, Hz, ...) 10:26:25 Sensor Voltage Measurement, Sensor Number = 1, V = 1.161692 V 10:26:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.161692 (V, A, ohm, ...), Measured Value = 12.126885 (C, atm, Hz, ...) 10:26:26 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001184 V 10:26:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001184 (V, A, ohm, ...), Measured Value = 1.183761 (C, atm, Hz, ...) 10:26:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.98 P1 = Main (V), Value = 10.57 P2 = Core_Top, Value = 22.16 P3 = Top_Coil, Value = 25.84 P4 = H20 In, Value = 27.60 P5 = H20 Out, Value = 31.84 P6 = Ambient, Value = 14.82 P7 = Supply Pres(psi), Value = 122.90 P8 = Return Pres(psi), Value = 12.13 P9 = Flow Rate(gpm), Value = 1.18 10:26:26 Integrated Voltage Measurement... 10:26:27 Magnet Current for MAIN, Imag = 149.9749 A Vtrans = 1.499748 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:26:35 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012945997 Vs 10:26:42 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012949889 Vs 10:26:43 Magnet Current for MAIN, Imag = 149.9761 A Vtrans = 1.499759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:26:50 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012960216 Vs 10:26:57 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012951574 Vs 10:26:58 Magnet Current for MAIN, Imag = 149.9761 A Vtrans = 1.499759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:27:05 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012952192 Vs 10:27:12 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012953783 Vs 10:27:13 Magnet Current for MAIN, Imag = 149.9761 A Vtrans = 1.499759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:27:21 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012953125 Vs 10:27:28 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012957237 Vs 10:27:29 Magnet Current for MAIN, Imag = 149.9748 A Vtrans = 1.499747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:27:36 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012954902 Vs 10:27:43 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012961773 Vs 10:27:43 Integrated Voltage Average and RMS of Measurements X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012954069 +- 0.000003507 Vs 10:27:43 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0125000 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.012954069 +- 0.000003507 Vs BL = -0.20726510 +- 0.00005611 Tm Remeasure 10:27:43 Integrated Voltage Measurement... 10:27:44 Magnet Current for MAIN, Imag = 149.9757 A Vtrans = 1.499755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:27:51 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012952763 Vs 10:27:58 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012952620 Vs 10:27:59 Magnet Current for MAIN, Imag = 149.9758 A Vtrans = 1.499756 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:28:06 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012944408 Vs 10:28:13 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012960107 Vs 10:28:14 Magnet Current for MAIN, Imag = 149.9762 A Vtrans = 1.499760 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:28:21 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012951979 Vs 10:28:28 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012958817 Vs 10:28:29 Magnet Current for MAIN, Imag = 149.9754 A Vtrans = 1.499753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:28:36 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012966781 Vs 10:28:43 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012959940 Vs 10:28:44 Magnet Current for MAIN, Imag = 149.9749 A Vtrans = 1.499748 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:28:51 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012953510 Vs 10:28:58 Integrated Voltage Measurement X0 = -0.0125000 m, Delta X = -0.0062500 m VT = 0.012956653 Vs 10:28:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0125000 m, Delta X = 0.0062500 m VT = -0.012955758 +- 0.000004001 Vs 10:28:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0125000 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.012955758 +- 0.000004001 Vs BL = -0.20729212 +- 0.00006402 Tm 10:28:58 Integrated Voltage Measurement... 10:28:59 Magnet Current for MAIN, Imag = 149.9758 A Vtrans = 1.499756 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:29:07 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006480538 Vs 10:29:14 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006483250 Vs 10:29:15 Magnet Current for MAIN, Imag = 149.9747 A Vtrans = 1.499745 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:29:22 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006483635 Vs 10:29:29 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006483048 Vs 10:29:29 Magnet Current for MAIN, Imag = 149.9752 A Vtrans = 1.499750 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:29:37 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006486237 Vs 10:29:44 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006485149 Vs 10:29:44 Magnet Current for MAIN, Imag = 149.9742 A Vtrans = 1.499740 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:29:51 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006486553 Vs 10:29:58 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006482088 Vs 10:29:59 Magnet Current for MAIN, Imag = 149.9751 A Vtrans = 1.499749 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:30:06 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006493628 Vs 10:30:13 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006481491 Vs 10:30:14 Integrated Voltage Average and RMS of Measurements X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006484562 +- 0.000001946 Vs 10:30:14 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.006484562 +- 0.000001946 Vs BL = -0.10375299 +- 0.00003114 Tm Remeasure 10:30:14 Integrated Voltage Measurement... 10:30:14 Magnet Current for MAIN, Imag = 149.9762 A Vtrans = 1.499760 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:30:21 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006485081 Vs 10:30:29 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006486584 Vs 10:30:29 Magnet Current for MAIN, Imag = 149.9763 A Vtrans = 1.499761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:30:36 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006490739 Vs 10:30:44 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006481170 Vs 10:30:44 Magnet Current for MAIN, Imag = 149.9753 A Vtrans = 1.499751 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:30:51 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006481891 Vs 10:30:58 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006482897 Vs 10:30:59 Magnet Current for MAIN, Imag = 149.9753 A Vtrans = 1.499751 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:31:06 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006487748 Vs 10:31:14 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006480422 Vs 10:31:14 Magnet Current for MAIN, Imag = 149.9757 A Vtrans = 1.499755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:31:21 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006488209 Vs 10:31:28 Integrated Voltage Measurement X0 = -0.0062500 m, Delta X = -0.0062500 m VT = 0.006485352 Vs 10:31:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0062500 m, Delta X = 0.0062500 m VT = -0.006485009 +- 0.000001575 Vs 10:31:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = -0.006485009 +- 0.000001575 Vs BL = -0.10376015 +- 0.00002520 Tm 10:31:29 Integrated Voltage Measurement... 10:31:29 Magnet Current for MAIN, Imag = 149.9761 A Vtrans = 1.499759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:31:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005839 Vs 10:31:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000001887 Vs 10:31:45 Magnet Current for MAIN, Imag = 149.9761 A Vtrans = 1.499759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:31:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005873 Vs 10:32:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000005013 Vs 10:32:01 Magnet Current for MAIN, Imag = 149.9761 A Vtrans = 1.499759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:32:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005710 Vs 10:32:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006051 Vs 10:32:16 Magnet Current for MAIN, Imag = 149.9766 A Vtrans = 1.499764 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:32:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005628 Vs 10:32:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006835 Vs 10:32:30 Magnet Current for MAIN, Imag = 149.9763 A Vtrans = 1.499761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:32:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003327 Vs 10:32:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006930 Vs 10:32:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000005309 +- 0.000000815 Vs 10:32:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000005309 +- 0.000000815 Vs BL = 0.00008495 +- 0.00001303 Tm Remeasure 10:32:45 Integrated Voltage Measurement... 10:32:46 Magnet Current for MAIN, Imag = 149.9762 A Vtrans = 1.499760 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:32:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003401 Vs 10:33:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004028 Vs 10:33:01 Magnet Current for MAIN, Imag = 149.9763 A Vtrans = 1.499761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:33:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000000205 Vs 10:33:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000007271 Vs 10:33:15 Magnet Current for MAIN, Imag = 149.9756 A Vtrans = 1.499754 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:33:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004871 Vs 10:33:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000005654 Vs 10:33:30 Magnet Current for MAIN, Imag = 149.9763 A Vtrans = 1.499761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:33:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000002624 Vs 10:33:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004119 Vs 10:33:45 Magnet Current for MAIN, Imag = 149.9761 A Vtrans = 1.499759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:33:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003282 Vs 10:34:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000004882 Vs 10:34:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004034 +- 0.000000654 Vs 10:34:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000004034 +- 0.000000654 Vs BL = 0.00006454 +- 0.00001047 Tm Remeasure 10:34:00 Integrated Voltage Measurement... 10:34:01 Magnet Current for MAIN, Imag = 149.9732 A Vtrans = 1.499730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:34:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000002224 Vs 10:34:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006868 Vs 10:34:15 Magnet Current for MAIN, Imag = 149.9759 A Vtrans = 1.499758 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:34:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000001156 Vs 10:34:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000005891 Vs 10:34:30 Magnet Current for MAIN, Imag = 149.9763 A Vtrans = 1.499761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:34:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003880 Vs 10:34:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006792 Vs 10:34:45 Magnet Current for MAIN, Imag = 149.9758 A Vtrans = 1.499756 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:34:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003011 Vs 10:34:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006955 Vs 10:35:00 Magnet Current for MAIN, Imag = 149.9771 A Vtrans = 1.499769 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:35:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000006086 Vs 10:35:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000005588 Vs 10:35:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000004845 +- 0.000000785 Vs 10:35:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000004845 +- 0.000000785 Vs BL = 0.00007752 +- 0.00001256 Tm Remeasure 10:35:14 Integrated Voltage Measurement... 10:35:15 Magnet Current for MAIN, Imag = 149.9762 A Vtrans = 1.499760 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:35:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003157 Vs 10:35:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000007348 Vs 10:35:30 Magnet Current for MAIN, Imag = 149.9768 A Vtrans = 1.499767 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:35:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000000696 Vs 10:35:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006260 Vs 10:35:45 Magnet Current for MAIN, Imag = 149.9763 A Vtrans = 1.499761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:35:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = -0.000000396 Vs 10:35:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006030 Vs 10:36:00 Magnet Current for MAIN, Imag = 149.9756 A Vtrans = 1.499754 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:36:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000001210 Vs 10:36:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000006851 Vs 10:36:15 Magnet Current for MAIN, Imag = 149.9748 A Vtrans = 1.499747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:36:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000000056 Vs 10:36:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0062500 m VT = -0.000003051 Vs 10:36:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0062500 m VT = 0.000003426 +- 0.000001231 Vs 10:36:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.000003426 +- 0.000001231 Vs BL = 0.00005482 +- 0.00001970 Tm 10:36:29 Integrated Voltage Measurement... 10:36:30 Magnet Current for MAIN, Imag = 149.9761 A Vtrans = 1.499759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:36:38 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006491358 Vs 10:36:45 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006500577 Vs 10:36:46 Magnet Current for MAIN, Imag = 149.9763 A Vtrans = 1.499761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:36:53 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006491487 Vs 10:37:00 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006496804 Vs 10:37:01 Magnet Current for MAIN, Imag = 149.9767 A Vtrans = 1.499765 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:37:08 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006491873 Vs 10:37:15 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006496827 Vs 10:37:16 Magnet Current for MAIN, Imag = 149.9766 A Vtrans = 1.499764 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:37:23 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006493656 Vs 10:37:30 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006496745 Vs 10:37:31 Magnet Current for MAIN, Imag = 149.9783 A Vtrans = 1.499782 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:37:38 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006493023 Vs 10:37:45 Integrated Voltage Measurement X0 = 0.0062500 m, Delta X = -0.0062500 m VT = -0.006495171 Vs 10:37:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0062500 m, Delta X = 0.0062500 m VT = 0.006494752 +- 0.000000726 Vs 10:37:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0062500 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.006494752 +- 0.000000726 Vs BL = 0.10391603 +- 0.00001162 Tm 10:37:46 Integrated Voltage Measurement... 10:37:46 Magnet Current for MAIN, Imag = 149.9758 A Vtrans = 1.499756 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:37:55 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012968331 Vs 10:38:02 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012967984 Vs 10:38:02 Magnet Current for MAIN, Imag = 149.9746 A Vtrans = 1.499744 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:38:09 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012963591 Vs 10:38:16 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012970125 Vs 10:38:17 Magnet Current for MAIN, Imag = 149.9786 A Vtrans = 1.499784 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:38:24 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012973641 Vs 10:38:31 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012970556 Vs 10:38:32 Magnet Current for MAIN, Imag = 149.9761 A Vtrans = 1.499759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:38:39 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012968490 Vs 10:38:46 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012974271 Vs 10:38:47 Magnet Current for MAIN, Imag = 149.9766 A Vtrans = 1.499764 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:38:54 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012972790 Vs 10:39:01 Integrated Voltage Measurement X0 = 0.0125000 m, Delta X = -0.0062500 m VT = -0.012968201 Vs 10:39:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0125000 m, Delta X = 0.0062500 m VT = 0.012969798 +- 0.000001981 Vs 10:39:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0125000 m, dx = 0.0062500 m, Nturns = 10.0 VT = 0.012969798 +- 0.000001981 Vs BL = 0.20751677 +- 0.00003170 Tm 10:39:05 Position moved: 0.000000 m 10:39:06 Magnet Current for MAIN, Imag = 149.9767 A Vtrans = 1.499765 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000171 A 10:39:07 Main (V) Voltage Measurement, V = 10.567556 V 10:39:10 Temperature Measurement, Probe Number = 0, T = 22.374000 C 10:39:11 Temperature Measurement, Probe Number = 1, T = 25.884000 C 10:39:12 Temperature Measurement, Probe Number = 2, T = 27.633000 C 10:39:12 Temperature Measurement, Probe Number = 3, T = 31.895000 C 10:39:13 Temperature Measurement, Probe Number = 4, T = 15.048000 C 10:39:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.644896 V 10:39:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.644896 (V, A, ohm, ...), Measured Value = 123.367185 (C, atm, Hz, ...) 10:39:14 Sensor Voltage Measurement, Sensor Number = 1, V = 1.162756 V 10:39:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.162756 (V, A, ohm, ...), Measured Value = 12.206677 (C, atm, Hz, ...) 10:39:15 Sensor Voltage Measurement, Sensor Number = 2, V = 0.001164 V 10:39:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.001164 (V, A, ohm, ...), Measured Value = 1.163700 (C, atm, Hz, ...) 10:39:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.98 P1 = Main (V), Value = 10.57 P2 = Core_Top, Value = 22.37 P3 = Top_Coil, Value = 25.88 P4 = H20 In, Value = 27.63 P5 = H20 Out, Value = 31.89 P6 = Ambient, Value = 15.05 P7 = Supply Pres(psi), Value = 123.37 P8 = Return Pres(psi), Value = 12.21 P9 = Flow Rate(gpm), Value = 1.16 10:39:18 Position moved: 0.000000 m 10:39:22 Magnet system MAIN current ramping to 0.0000 A...