SLAC Magnetic Measurements Date: 05-03-2010 Time: 15:33:38 Project: LBL Magnet Type: quad Magnet Name: PMQ2 Serial Number: Long Run Number: 2 Measurement Device: 1 wire Operator: sda Comment: Integrated strength vs x to measure gradient. Polarity is negative. Roll adjustment same as run 1 Test Currents (A): 0.0 0.0 0.0 15:34:08 Name = None, is zeroed 15:34:08 Integrated Voltage Measurement... 15:34:26 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000005741 V 15:34:26 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012474 Vs 15:34:43 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006250 V 15:34:43 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012589 Vs 15:35:00 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006250 V 15:35:00 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012415 Vs 15:35:18 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000005959 V 15:35:18 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012497 Vs 15:35:35 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006250 V 15:35:35 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012469 Vs 15:35:52 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006541 V 15:35:52 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012588 Vs 15:36:09 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006395 V 15:36:09 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012500 Vs 15:36:27 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006105 V 15:36:27 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012513 Vs 15:36:44 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006395 V 15:36:44 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012472 Vs 15:37:01 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006395 V 15:37:01 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012556 Vs 15:37:18 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006105 V 15:37:18 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012444 Vs 15:37:36 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006541 V 15:37:36 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012676 Vs 15:37:53 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006250 V 15:37:53 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012450 Vs 15:38:10 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006686 V 15:38:10 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012509 Vs 15:38:27 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006250 V 15:38:28 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012459 Vs 15:38:45 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006105 V 15:38:45 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012534 Vs 15:38:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012509 +- 0.000000030 Vs 15:38:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000012509 +- 0.000000030 Vs BL = -0.02501820 +- 0.00006065 Tm 15:38:45 Integrated Voltage Measurement... 15:39:02 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006395 V 15:39:02 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006293 Vs 15:39:20 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006468 V 15:39:20 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006339 Vs 15:39:37 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006468 V 15:39:37 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006244 Vs 15:39:54 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006323 V 15:39:54 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006415 Vs 15:40:12 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006032 V 15:40:12 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006270 Vs 15:40:29 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006032 V 15:40:29 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006310 Vs 15:40:46 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006468 V 15:40:46 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006324 Vs 15:41:03 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006323 V 15:41:03 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006364 Vs 15:41:21 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006250 V 15:41:21 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006214 Vs 15:41:38 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006395 V 15:41:38 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006339 Vs 15:41:55 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006613 V 15:41:55 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006283 Vs 15:42:12 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006032 V 15:42:13 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006251 Vs 15:42:30 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006250 V 15:42:30 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006318 Vs 15:42:47 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006395 V 15:42:47 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006316 Vs 15:43:05 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006105 V 15:43:05 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006260 Vs 15:43:22 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006468 V 15:43:22 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006340 Vs 15:43:22 Integrated Voltage Average and RMS of Measurements X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006305 +- 0.000000025 Vs 15:43:22 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000006305 +- 0.000000025 Vs BL = -0.01260993 +- 0.00004937 Tm 15:43:22 Integrated Voltage Measurement... 15:43:40 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006541 V 15:43:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000027 Vs 15:43:57 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006177 V 15:43:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000048 Vs 15:44:14 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006105 V 15:44:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000042 Vs 15:44:32 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006323 V 15:44:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000033 Vs 15:44:49 Voltage Offset Correction: v_off_ini = -0.000006032 V, v_off_fin = -0.000006468 V 15:44:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000055 Vs 15:45:06 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006395 V 15:45:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000004 Vs 15:45:24 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006032 V 15:45:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000109 Vs 15:45:41 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006468 V 15:45:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000101 Vs 15:45:58 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006032 V 15:45:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000052 Vs 15:46:15 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006250 V 15:46:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000035 Vs 15:46:33 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006177 V 15:46:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000034 Vs 15:46:50 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000005887 V 15:46:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000051 Vs 15:47:07 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006468 V 15:47:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000136 Vs 15:47:24 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006395 V 15:47:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000046 Vs 15:47:42 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006250 V 15:47:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000114 Vs 15:47:59 Voltage Offset Correction: v_off_ini = -0.000006032 V, v_off_fin = -0.000006613 V 15:47:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000008 Vs 15:47:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000056 +- 0.000000026 Vs 15:47:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000056 +- 0.000000026 Vs BL = 0.00011165 +- 0.00005179 Tm 15:47:59 Integrated Voltage Measurement... 15:48:16 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006323 V 15:48:16 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006420 Vs 15:48:34 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006032 V 15:48:34 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006449 Vs 15:48:51 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006541 V 15:48:51 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006452 Vs 15:49:08 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006105 V 15:49:08 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006393 Vs 15:49:25 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006323 V 15:49:26 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006406 Vs 15:49:43 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006105 V 15:49:43 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006383 Vs 15:50:00 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006250 V 15:50:00 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006439 Vs 15:50:17 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006323 V 15:50:17 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006283 Vs 15:50:35 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006323 V 15:50:35 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006504 Vs 15:50:52 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006177 V 15:50:52 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006388 Vs 15:51:09 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006177 V 15:51:09 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006466 Vs 15:51:26 Voltage Offset Correction: v_off_ini = -0.000006032 V, v_off_fin = -0.000006468 V 15:51:26 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006311 Vs 15:51:44 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006032 V 15:51:44 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006382 Vs 15:52:01 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006468 V 15:52:01 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006353 Vs 15:52:18 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006105 V 15:52:18 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006436 Vs 15:52:36 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006177 V 15:52:36 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006373 Vs 15:52:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006402 +- 0.000000029 Vs 15:52:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000006402 +- 0.000000029 Vs BL = 0.01280484 +- 0.00005728 Tm 15:52:36 Integrated Voltage Measurement... 15:52:53 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006613 V 15:52:53 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012610 Vs 15:53:11 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006323 V 15:53:11 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012536 Vs 15:53:28 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006323 V 15:53:28 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012556 Vs 15:53:45 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000005887 V 15:53:45 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012568 Vs 15:54:02 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006613 V 15:54:02 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012583 Vs 15:54:20 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006613 V 15:54:20 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012515 Vs 15:54:37 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006323 V 15:54:37 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012645 Vs 15:54:54 Voltage Offset Correction: v_off_ini = -0.000006686 V, v_off_fin = -0.000006323 V 15:54:54 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012437 Vs 15:55:11 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006613 V 15:55:11 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012639 Vs 15:55:29 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006250 V 15:55:29 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012561 Vs 15:55:46 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006541 V 15:55:46 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012672 Vs 15:56:03 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006177 V 15:56:03 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012553 Vs 15:56:21 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006250 V 15:56:21 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012646 Vs 15:56:38 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006468 V 15:56:38 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012531 Vs 15:56:55 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006613 V 15:56:55 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012716 Vs 15:57:12 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006395 V 15:57:12 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012443 Vs 15:57:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012576 +- 0.000000023 Vs 15:57:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000012576 +- 0.000000023 Vs BL = 0.02515139 +- 0.00004589 Tm 15:57:21 Integrated Voltage Measurement... 15:57:38 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006323 V 15:57:38 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012509 Vs 15:57:56 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006468 V 15:57:56 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012583 Vs 15:58:13 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006250 V 15:58:13 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012499 Vs 15:58:30 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006323 V 15:58:30 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012553 Vs 15:58:47 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006541 V 15:58:47 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012491 Vs 15:59:05 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006468 V 15:59:05 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012624 Vs 15:59:22 Voltage Offset Correction: v_off_ini = -0.000006759 V, v_off_fin = -0.000006105 V 15:59:22 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012506 Vs 15:59:39 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006468 V 15:59:39 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012556 Vs 15:59:56 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000005959 V 15:59:56 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012551 Vs 16:00:14 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006323 V 16:00:14 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012496 Vs 16:00:31 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006395 V 16:00:31 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012481 Vs 16:00:48 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006468 V 16:00:48 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012580 Vs 16:01:06 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006541 V 16:01:06 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012454 Vs 16:01:23 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006613 V 16:01:23 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012635 Vs 16:01:40 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006323 V 16:01:40 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012560 Vs 16:01:57 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006395 V 16:01:57 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012605 Vs 16:01:57 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012543 +- 0.000000019 Vs 16:01:57 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000012543 +- 0.000000019 Vs BL = -0.02508543 +- 0.00003723 Tm 16:01:57 Integrated Voltage Measurement... 16:02:15 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006686 V 16:02:15 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006258 Vs 16:02:32 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006177 V 16:02:32 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006422 Vs 16:02:49 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006323 V 16:02:50 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006263 Vs 16:03:07 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006177 V 16:03:07 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006323 Vs 16:03:24 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006323 V 16:03:24 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006236 Vs 16:03:41 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006177 V 16:03:41 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006400 Vs 16:03:59 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006686 V 16:03:59 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006274 Vs 16:04:16 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006613 V 16:04:16 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006353 Vs 16:04:33 Voltage Offset Correction: v_off_ini = -0.000006686 V, v_off_fin = -0.000006395 V 16:04:33 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006245 Vs 16:04:50 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006105 V 16:04:50 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006297 Vs 16:05:08 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006541 V 16:05:08 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006294 Vs 16:05:25 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006177 V 16:05:25 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006382 Vs 16:05:42 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006613 V 16:05:42 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006215 Vs 16:06:00 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006613 V 16:06:00 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006332 Vs 16:06:17 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006759 V 16:06:17 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006281 Vs 16:06:34 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006613 V 16:06:34 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006402 Vs 16:06:34 Integrated Voltage Average and RMS of Measurements X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006311 +- 0.000000027 Vs 16:06:34 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000006311 +- 0.000000027 Vs BL = -0.01262204 +- 0.00005439 Tm 16:06:34 Integrated Voltage Measurement... 16:06:52 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006323 V 16:06:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000124 Vs 16:07:09 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006323 V 16:07:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000046 Vs 16:07:26 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006395 V 16:07:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000032 Vs 16:07:44 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006323 V 16:07:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = 0.000000002 Vs 16:08:01 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006250 V 16:08:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000131 Vs 16:08:18 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006395 V 16:08:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = 0.000000003 Vs 16:08:35 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006468 V 16:08:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000073 Vs 16:08:53 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006395 V 16:08:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000050 Vs 16:09:10 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006250 V 16:09:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000050 Vs 16:09:27 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006541 V 16:09:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000075 Vs 16:09:44 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006250 V 16:09:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000181 Vs 16:10:02 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006177 V 16:10:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000061 Vs 16:10:19 Voltage Offset Correction: v_off_ini = -0.000006686 V, v_off_fin = -0.000006250 V 16:10:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000114 Vs 16:10:36 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006613 V 16:10:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = 0.000000001 Vs 16:10:54 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006177 V 16:10:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000112 Vs 16:11:11 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006395 V 16:11:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000042 Vs 16:11:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000068 +- 0.000000028 Vs 16:11:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000068 +- 0.000000028 Vs BL = 0.00013559 +- 0.00005565 Tm 16:11:11 Integrated Voltage Measurement... 16:11:29 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006759 V 16:11:29 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006398 Vs 16:11:46 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006541 V 16:11:46 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006422 Vs 16:12:03 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006250 V 16:12:03 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006459 Vs 16:12:20 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006541 V 16:12:20 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006353 Vs 16:12:38 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006395 V 16:12:38 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006477 Vs 16:12:55 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006686 V 16:12:55 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006257 Vs 16:13:12 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006613 V 16:13:12 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006444 Vs 16:13:29 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006395 V 16:13:29 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006408 Vs 16:13:47 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006468 V 16:13:47 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006464 Vs 16:14:04 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006541 V 16:14:04 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006371 Vs 16:14:21 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006468 V 16:14:21 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006436 Vs 16:14:38 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006613 V 16:14:38 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006361 Vs 16:14:56 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006250 V 16:14:56 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006437 Vs 16:15:13 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006468 V 16:15:13 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006396 Vs 16:15:30 Voltage Offset Correction: v_off_ini = -0.000006686 V, v_off_fin = -0.000006250 V 16:15:30 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006509 Vs 16:15:47 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006395 V 16:15:47 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006404 Vs 16:15:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006412 +- 0.000000024 Vs 16:15:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000006412 +- 0.000000024 Vs BL = 0.01282452 +- 0.00004726 Tm 16:15:48 Integrated Voltage Measurement... 16:16:05 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006395 V 16:16:05 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012612 Vs 16:16:22 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006105 V 16:16:22 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012575 Vs 16:16:40 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006105 V 16:16:40 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012542 Vs 16:16:57 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006395 V 16:16:57 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012494 Vs 16:17:14 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006395 V 16:17:14 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012590 Vs 16:17:31 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006395 V 16:17:31 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012497 Vs 16:17:49 Voltage Offset Correction: v_off_ini = -0.000006686 V, v_off_fin = -0.000006468 V 16:17:49 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012708 Vs 16:18:06 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006250 V 16:18:06 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012541 Vs 16:18:23 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006686 V 16:18:24 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012709 Vs 16:18:41 Voltage Offset Correction: v_off_ini = -0.000006686 V, v_off_fin = -0.000006250 V 16:18:41 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012507 Vs 16:18:58 Voltage Offset Correction: v_off_ini = -0.000006032 V, v_off_fin = -0.000006613 V 16:18:58 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012559 Vs 16:19:16 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006323 V 16:19:16 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012456 Vs 16:19:33 Voltage Offset Correction: v_off_ini = -0.000006686 V, v_off_fin = -0.000006395 V 16:19:33 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012666 Vs 16:19:50 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006613 V 16:19:50 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012540 Vs 16:20:07 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006541 V 16:20:07 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012610 Vs 16:20:25 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000005959 V 16:20:25 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012548 Vs 16:20:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012572 +- 0.000000041 Vs 16:20:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000012572 +- 0.000000041 Vs BL = 0.02514432 +- 0.00008197 Tm 16:20:33 Integrated Voltage Measurement... 16:20:51 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006323 V 16:20:51 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012556 Vs 16:21:08 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006468 V 16:21:08 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012583 Vs 16:21:25 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006177 V 16:21:25 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012500 Vs 16:21:42 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006323 V 16:21:42 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012458 Vs 16:22:00 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006468 V 16:22:00 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012547 Vs 16:22:17 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006177 V 16:22:17 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012525 Vs 16:22:34 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006250 V 16:22:34 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012507 Vs 16:22:51 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006613 V 16:22:51 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012519 Vs 16:23:09 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006395 V 16:23:09 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012467 Vs 16:23:26 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006323 V 16:23:26 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012559 Vs 16:23:43 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006323 V 16:23:43 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012476 Vs 16:24:00 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006759 V 16:24:00 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012671 Vs 16:24:18 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006686 V 16:24:18 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012437 Vs 16:24:35 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006613 V 16:24:35 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012610 Vs 16:24:52 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006177 V 16:24:52 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012529 Vs 16:25:10 Voltage Offset Correction: v_off_ini = -0.000006686 V, v_off_fin = -0.000006323 V 16:25:10 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000012562 Vs 16:25:10 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000012532 +- 0.000000030 Vs 16:25:10 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000012532 +- 0.000000030 Vs BL = -0.02506312 +- 0.00005906 Tm 16:25:10 Integrated Voltage Measurement... 16:25:27 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006468 V 16:25:27 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006314 Vs 16:25:44 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006250 V 16:25:44 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006365 Vs 16:26:02 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006541 V 16:26:02 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006292 Vs 16:26:19 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006686 V 16:26:19 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006409 Vs 16:26:36 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006395 V 16:26:36 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006305 Vs 16:26:53 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006105 V 16:26:54 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006286 Vs 16:27:11 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006395 V 16:27:11 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006267 Vs 16:27:28 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006613 V 16:27:28 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006403 Vs 16:27:45 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006105 V 16:27:45 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006243 Vs 16:28:03 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006323 V 16:28:03 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006316 Vs 16:28:20 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006613 V 16:28:20 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006217 Vs 16:28:37 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006177 V 16:28:37 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006289 Vs 16:28:54 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006686 V 16:28:54 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006177 Vs 16:29:12 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006250 V 16:29:12 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006342 Vs 16:29:29 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006541 V 16:29:29 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006286 Vs 16:29:46 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006323 V 16:29:46 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000006359 Vs 16:29:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000006304 +- 0.000000035 Vs 16:29:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000006304 +- 0.000000035 Vs BL = -0.01260879 +- 0.00007062 Tm 16:29:46 Integrated Voltage Measurement... 16:30:04 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006759 V 16:30:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000129 Vs 16:30:21 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006395 V 16:30:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000017 Vs 16:30:38 Voltage Offset Correction: v_off_ini = -0.000006759 V, v_off_fin = -0.000006177 V 16:30:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000095 Vs 16:30:55 Voltage Offset Correction: v_off_ini = -0.000006759 V, v_off_fin = -0.000006250 V 16:30:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000047 Vs 16:31:13 Voltage Offset Correction: v_off_ini = -0.000006105 V, v_off_fin = -0.000006541 V 16:31:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000062 Vs 16:31:30 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006395 V 16:31:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000006 Vs 16:31:47 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006250 V 16:31:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000082 Vs 16:32:05 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006541 V 16:32:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = 0.000000006 Vs 16:32:22 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006468 V 16:32:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000103 Vs 16:32:39 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006613 V 16:32:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = 0.000000018 Vs 16:32:56 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006686 V 16:32:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000051 Vs 16:33:14 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006395 V 16:33:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000040 Vs 16:33:31 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006541 V 16:33:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000102 Vs 16:33:48 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006177 V 16:33:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = 0.000000009 Vs 16:34:06 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006468 V 16:34:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000033 Vs 16:34:23 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006686 V 16:34:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = 0.000000030 Vs 16:34:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000044 +- 0.000000021 Vs 16:34:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000044 +- 0.000000021 Vs BL = 0.00008796 +- 0.00004204 Tm 16:34:23 Integrated Voltage Measurement... 16:34:40 Voltage Offset Correction: v_off_ini = -0.000006759 V, v_off_fin = -0.000006541 V 16:34:40 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006538 Vs 16:34:58 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006250 V 16:34:58 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006390 Vs 16:35:15 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006686 V 16:35:15 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006499 Vs 16:35:32 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006395 V 16:35:32 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006355 Vs 16:35:50 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006541 V 16:35:50 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006515 Vs 16:36:07 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006613 V 16:36:07 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006357 Vs 16:36:24 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006468 V 16:36:24 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006372 Vs 16:36:41 Voltage Offset Correction: v_off_ini = -0.000006686 V, v_off_fin = -0.000006250 V 16:36:41 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006329 Vs 16:36:59 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006395 V 16:36:59 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006453 Vs 16:37:16 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006395 V 16:37:16 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006370 Vs 16:37:33 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006613 V 16:37:33 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006505 Vs 16:37:50 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006468 V 16:37:50 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006356 Vs 16:38:08 Voltage Offset Correction: v_off_ini = -0.000006759 V, v_off_fin = -0.000006395 V 16:38:08 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006474 Vs 16:38:25 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006250 V 16:38:25 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006371 Vs 16:38:42 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006323 V 16:38:42 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006477 Vs 16:39:00 Voltage Offset Correction: v_off_ini = -0.000006613 V, v_off_fin = -0.000006323 V 16:39:00 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000006390 Vs 16:39:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000006422 +- 0.000000030 Vs 16:39:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000006422 +- 0.000000030 Vs BL = 0.01284383 +- 0.00006064 Tm 16:39:00 Integrated Voltage Measurement... 16:39:17 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006541 V 16:39:17 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012604 Vs 16:39:34 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006468 V 16:39:34 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012556 Vs 16:39:52 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006686 V 16:39:52 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012613 Vs 16:40:09 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006541 V 16:40:09 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012534 Vs 16:40:26 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006395 V 16:40:26 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012567 Vs 16:40:43 Voltage Offset Correction: v_off_ini = -0.000006250 V, v_off_fin = -0.000006468 V 16:40:44 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012535 Vs 16:41:01 Voltage Offset Correction: v_off_ini = -0.000006759 V, v_off_fin = -0.000006177 V 16:41:01 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012573 Vs 16:41:18 Voltage Offset Correction: v_off_ini = -0.000006323 V, v_off_fin = -0.000006468 V 16:41:18 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012522 Vs 16:41:35 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006613 V 16:41:35 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012655 Vs 16:41:53 Voltage Offset Correction: v_off_ini = -0.000006395 V, v_off_fin = -0.000006323 V 16:41:53 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012522 Vs 16:42:10 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006468 V 16:42:10 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012595 Vs 16:42:27 Voltage Offset Correction: v_off_ini = -0.000006759 V, v_off_fin = -0.000006250 V 16:42:27 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012506 Vs 16:42:44 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006468 V 16:42:44 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012618 Vs 16:43:02 Voltage Offset Correction: v_off_ini = -0.000006177 V, v_off_fin = -0.000006541 V 16:43:02 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012518 Vs 16:43:19 Voltage Offset Correction: v_off_ini = -0.000006468 V, v_off_fin = -0.000006541 V 16:43:19 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012622 Vs 16:43:36 Voltage Offset Correction: v_off_ini = -0.000006541 V, v_off_fin = -0.000006395 V 16:43:36 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000012473 Vs 16:43:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000012563 +- 0.000000015 Vs 16:43:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000012563 +- 0.000000015 Vs BL = 0.02512695 +- 0.00003048 Tm 16:43:57 Name = None, is zeroed