SLAC Magnetic Measurements Date: 12-01-2011 Time: 16:20:08 Project: LBL Magnet Type: Dipole Magnet Name: BELLA_Spectrometer Serial Number: Run Number: 2 Measurement Device: 10 wire Operator: sda Comment: Integrated field strength at currents from 50 to 800 amps. Wire moved 10 mm. Standardization: 3 cycles from 50.0 A to 800.0 A to 50.0 A Test Currents (A): 50.0 75.0 100.0 125.0 150.0 175.0 200.0 225.0 250.0 275.0 300.0 325.0 350.0 400.0 425.0 450.0 475.0 500.0 525.0 550.0 575.0 600.0 620.0 640.0 660.0 680.0 700.0 720.0 740.0 760.0 780.0 800.0 16:20:45 Magnet Current, Imag = -0.010778 A Vtrans = -0.000108 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:46 Magnet Current, Imag = -0.010785 A Vtrans = -0.000108 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:46 Magnet Current, Imag = -0.010706 A Vtrans = -0.000107 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:47 Magnet Current, Imag = -0.010762 A Vtrans = -0.000108 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:47 Magnet Current Measurement: Imag = -0.0108 +- 0.0000 A 16:21:13 Initial Zero Current Measurement, Imag_zero = -0.0108 A 16:21:13 Magnet current ramping to 50.0000 A... 16:21:51 Magnet Current, Imag = 49.089852 A Vtrans = 0.490791 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:21:51 Magnet Current, Imag = 49.807003 A Vtrans = 0.497962 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:21:52 Magnet Current, Imag = 50.239790 A Vtrans = 0.502290 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:21:53 Magnet Current, Imag = 50.225913 A Vtrans = 0.502152 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:21:53 Magnet Current Measurement: Imag = 49.8406 +- 0.4671 A 16:21:53 Magnet current ramping to 800.0000 A... 16:23:58 Magnet current ramping to 50.0000 A... 16:26:03 Magnet current ramping to 800.0000 A... 16:28:08 Magnet current ramping to 50.0000 A... 16:30:13 Magnet current ramping to 800.0000 A... 16:32:19 Magnet current ramping to 50.0000 A... 16:34:36 Name = None, is zeroed 16:34:36 Magnet current ramping to 50.0000 A... 16:34:56 Magnetic Field Measurement Measuring the magnet strength... 16:34:56 Integrated Voltage Measurement... 16:34:57 Magnet Current, Imag = 49.841230 A Vtrans = 0.498305 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:35:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021187972 Vs 16:35:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021301825 Vs 16:35:35 Magnet Current, Imag = 49.844780 A Vtrans = 0.498340 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:35:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021109796 Vs 16:36:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021188382 Vs 16:36:12 Magnet Current, Imag = 49.851137 A Vtrans = 0.498404 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:36:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021177277 Vs 16:36:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021215505 Vs 16:36:49 Magnet Current, Imag = 49.854061 A Vtrans = 0.498433 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:37:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021123619 Vs 16:37:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021121669 Vs 16:37:26 Magnet Current, Imag = 49.853142 A Vtrans = 0.498424 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:37:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021149221 Vs 16:38:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021418580 Vs 16:38:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021199385 +- 0.000059400 Vs 16:38:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.021199385 +- 0.000059400 Vs BL = 0.21199385 +- 0.00059400 Tm 16:38:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.21199 0.00059 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.21199 0.00059 0.21199 0.00000 16:38:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.21199 0.00059 SL = 0.2119938 +- 0.0005940 Tm^2/m^n 16:38:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2119938 +- 0.0005940 Tm^2/m^n Remeasure 16:38:12 Magnetic Field Measurement Measuring the magnet strength... 16:38:12 Integrated Voltage Measurement... 16:38:12 Magnet Current, Imag = 49.838958 A Vtrans = 0.498282 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:38:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021251613 Vs 16:38:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021267412 Vs 16:38:50 Magnet Current, Imag = 49.858733 A Vtrans = 0.498480 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:39:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021109260 Vs 16:39:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021178788 Vs 16:39:27 Magnet Current, Imag = 49.883462 A Vtrans = 0.498727 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:39:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021146421 Vs 16:40:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021235809 Vs 16:40:04 Magnet Current, Imag = 49.861121 A Vtrans = 0.498504 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:40:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021154849 Vs 16:40:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021295498 Vs 16:40:42 Magnet Current, Imag = 49.852861 A Vtrans = 0.498421 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:41:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021162053 Vs 16:41:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021167982 Vs 16:41:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021196969 +- 0.000041390 Vs 16:41:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.021196969 +- 0.000041390 Vs BL = 0.21196969 +- 0.00041390 Tm 16:41:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.21197 0.00041 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.21197 0.00041 0.21197 0.00000 16:41:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.21197 0.00041 SL = 0.2119697 +- 0.0004139 Tm^2/m^n 16:41:27 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2119697 +- 0.0004139 Tm^2/m^n 16:41:27 Magnet Current, Imag = 49.830124 A Vtrans = 0.498194 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:41:28 Magnet Current, Imag = 49.823000 A Vtrans = 0.498122 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:41:29 Magnet Current, Imag = 49.858172 A Vtrans = 0.498474 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:41:29 Magnet Current, Imag = 49.857853 A Vtrans = 0.498471 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:41:29 Magnet Current Measurement: Imag = 49.8423 +- 0.0159 A Remeasure 16:41:29 Magnetic Field Measurement Measuring the magnet strength... 16:41:29 Integrated Voltage Measurement... 16:41:30 Magnet Current, Imag = 49.854776 A Vtrans = 0.498440 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:41:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021151110 Vs 16:42:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021216642 Vs 16:42:08 Magnet Current, Imag = 49.846516 A Vtrans = 0.498358 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:42:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021301999 Vs 16:42:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021099293 Vs 16:42:45 Magnet Current, Imag = 49.813693 A Vtrans = 0.498029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:43:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021138586 Vs 16:43:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021283510 Vs 16:43:22 Magnet Current, Imag = 49.837669 A Vtrans = 0.498269 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:43:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021149267 Vs 16:43:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021231578 Vs 16:44:00 Magnet Current, Imag = 49.880717 A Vtrans = 0.498700 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:44:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021186952 Vs 16:44:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021162144 Vs 16:44:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021192108 +- 0.000012732 Vs 16:44:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.021192108 +- 0.000012732 Vs BL = 0.21192108 +- 0.00012732 Tm 16:44:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.21192 0.00013 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.21192 0.00013 0.21192 0.00000 16:44:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.21192 0.00013 SL = 0.2119211 +- 0.0001273 Tm^2/m^n 16:44:45 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2119211 +- 0.0001273 Tm^2/m^n 16:44:45 Magnet Current, Imag = 49.836086 A Vtrans = 0.498253 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:44:46 Magnet Current, Imag = 49.845048 A Vtrans = 0.498343 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:44:47 Magnet Current, Imag = 49.851303 A Vtrans = 0.498405 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:44:47 Magnet Current, Imag = 49.852733 A Vtrans = 0.498420 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:44:47 Magnet Current Measurement: Imag = 49.8463 +- 0.0066 A 16:44:47 Magnet current ramping to 75.0000 A... 16:45:11 Magnetic Field Measurement Measuring the magnet strength... 16:45:11 Integrated Voltage Measurement... 16:45:12 Magnet Current, Imag = 75.064993 A Vtrans = 0.750542 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:45:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031549800 Vs 16:45:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031453908 Vs 16:45:50 Magnet Current, Imag = 75.068657 A Vtrans = 0.750579 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:46:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031582338 Vs 16:46:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031602739 Vs 16:46:27 Magnet Current, Imag = 75.051027 A Vtrans = 0.750403 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:46:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031482048 Vs 16:47:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031539243 Vs 16:47:04 Magnet Current, Imag = 75.055597 A Vtrans = 0.750448 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:47:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031454340 Vs 16:47:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031480016 Vs 16:47:41 Magnet Current, Imag = 75.055010 A Vtrans = 0.750443 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:47:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031479344 Vs 16:48:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031540678 Vs 16:48:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031516445 +- 0.000041244 Vs 16:48:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.031516445 +- 0.000041244 Vs BL = 0.31516445 +- 0.00041244 Tm 16:48:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31516 0.00041 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.31516 0.00041 0.31516 0.00000 16:48:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31516 0.00041 SL = 0.3151645 +- 0.0004124 Tm^2/m^n 16:48:26 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3151645 +- 0.0004124 Tm^2/m^n Remeasure 16:48:26 Magnetic Field Measurement Measuring the magnet strength... 16:48:26 Integrated Voltage Measurement... 16:48:27 Magnet Current, Imag = 75.062619 A Vtrans = 0.750519 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:48:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031499825 Vs 16:49:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031528739 Vs 16:49:05 Magnet Current, Imag = 75.052405 A Vtrans = 0.750416 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:49:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031450790 Vs 16:49:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031407619 Vs 16:49:42 Magnet Current, Imag = 75.069832 A Vtrans = 0.750591 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:50:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031493342 Vs 16:50:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031421508 Vs 16:50:19 Magnet Current, Imag = 75.074172 A Vtrans = 0.750634 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:50:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031402180 Vs 16:50:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031447429 Vs 16:50:56 Magnet Current, Imag = 75.055176 A Vtrans = 0.750444 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:51:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031535519 Vs 16:51:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031426724 Vs 16:51:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031461368 +- 0.000033398 Vs 16:51:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.031461368 +- 0.000033398 Vs BL = 0.31461368 +- 0.00033398 Tm 16:51:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31461 0.00033 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.31461 0.00033 0.31461 0.00000 16:51:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31461 0.00033 SL = 0.3146137 +- 0.0003340 Tm^2/m^n 16:51:41 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3146137 +- 0.0003340 Tm^2/m^n 16:51:42 Magnet Current, Imag = 75.070751 A Vtrans = 0.750600 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:51:43 Magnet Current, Imag = 75.061827 A Vtrans = 0.750511 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:51:43 Magnet Current, Imag = 75.057665 A Vtrans = 0.750469 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:51:44 Magnet Current, Imag = 75.062338 A Vtrans = 0.750516 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:51:44 Magnet Current Measurement: Imag = 75.0631 +- 0.0048 A Remeasure 16:51:44 Magnetic Field Measurement Measuring the magnet strength... 16:51:44 Integrated Voltage Measurement... 16:51:45 Magnet Current, Imag = 75.058559 A Vtrans = 0.750478 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:52:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031444369 Vs 16:52:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031467124 Vs 16:52:22 Magnet Current, Imag = 75.051601 A Vtrans = 0.750408 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:52:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031524951 Vs 16:52:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031554049 Vs 16:53:00 Magnet Current, Imag = 75.070253 A Vtrans = 0.750595 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:53:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031530542 Vs 16:53:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031430694 Vs 16:53:37 Magnet Current, Imag = 75.035362 A Vtrans = 0.750246 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:53:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031470991 Vs 16:54:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031433587 Vs 16:54:14 Magnet Current, Imag = 75.065083 A Vtrans = 0.750543 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:54:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031357918 Vs 16:54:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.031498517 Vs 16:54:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.031471274 +- 0.000037941 Vs 16:54:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.031471274 +- 0.000037941 Vs BL = 0.31471274 +- 0.00037941 Tm 16:54:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31471 0.00038 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.31471 0.00038 0.31471 0.00000 16:54:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31471 0.00038 SL = 0.3147127 +- 0.0003794 Tm^2/m^n 16:54:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3147127 +- 0.0003794 Tm^2/m^n 16:55:00 Magnet Current, Imag = 75.047695 A Vtrans = 0.750369 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:55:00 Magnet Current, Imag = 75.065134 A Vtrans = 0.750544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:55:01 Magnet Current, Imag = 75.051129 A Vtrans = 0.750404 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:55:02 Magnet Current, Imag = 75.055750 A Vtrans = 0.750450 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:55:02 Magnet Current Measurement: Imag = 75.0549 +- 0.0065 A 16:55:02 Magnet current ramping to 100.0000 A... 16:55:26 Magnetic Field Measurement Measuring the magnet strength... 16:55:26 Integrated Voltage Measurement... 16:55:26 Magnet Current, Imag = 99.978713 A Vtrans = 0.999680 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:55:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041657319 Vs 16:56:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041753380 Vs 16:56:04 Magnet Current, Imag = 99.985480 A Vtrans = 0.999747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:56:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041729758 Vs 16:56:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041699206 Vs 16:56:41 Magnet Current, Imag = 99.984011 A Vtrans = 0.999733 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:57:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041619653 Vs 16:57:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041695168 Vs 16:57:19 Magnet Current, Imag = 99.956563 A Vtrans = 0.999458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:57:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041675561 Vs 16:57:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041685107 Vs 16:57:56 Magnet Current, Imag = 99.964734 A Vtrans = 0.999540 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:58:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041619324 Vs 16:58:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041543808 Vs 16:58:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041667828 +- 0.000047520 Vs 16:58:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.041667828 +- 0.000047520 Vs BL = 0.41667828 +- 0.00047520 Tm 16:58:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.41668 0.00048 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.41668 0.00048 0.41668 0.00000 16:58:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.41668 0.00048 SL = 0.4166783 +- 0.0004752 Tm^2/m^n 16:58:41 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4166783 +- 0.0004752 Tm^2/m^n Remeasure 16:58:41 Magnetic Field Measurement Measuring the magnet strength... 16:58:41 Integrated Voltage Measurement... 16:58:41 Magnet Current, Imag = 99.968653 A Vtrans = 0.999579 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:59:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041646407 Vs 16:59:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041692122 Vs 16:59:19 Magnet Current, Imag = 99.981113 A Vtrans = 0.999704 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 16:59:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041675311 Vs 16:59:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041696960 Vs 16:59:56 Magnet Current, Imag = 99.966470 A Vtrans = 0.999557 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:00:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041613841 Vs 17:00:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041671890 Vs 17:00:34 Magnet Current, Imag = 99.993574 A Vtrans = 0.999828 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:00:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041737480 Vs 17:01:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041680283 Vs 17:01:11 Magnet Current, Imag = 99.968181 A Vtrans = 0.999574 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:01:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041742136 Vs 17:01:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041741573 Vs 17:01:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041689800 +- 0.000033799 Vs 17:01:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.041689800 +- 0.000033799 Vs BL = 0.41689800 +- 0.00033799 Tm 17:01:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.41690 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.41690 0.00034 0.41690 0.00000 17:01:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.41690 0.00034 SL = 0.4168980 +- 0.0003380 Tm^2/m^n 17:01:56 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4168980 +- 0.0003380 Tm^2/m^n 17:01:57 Magnet Current, Imag = 99.972317 A Vtrans = 0.999616 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:01:57 Magnet Current, Imag = 99.978509 A Vtrans = 0.999678 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:01:58 Magnet Current, Imag = 99.976530 A Vtrans = 0.999658 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:01:59 Magnet Current, Imag = 99.972432 A Vtrans = 0.999617 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:01:59 Magnet Current Measurement: Imag = 99.9749 +- 0.0027 A Remeasure 17:01:59 Magnetic Field Measurement Measuring the magnet strength... 17:01:59 Integrated Voltage Measurement... 17:01:59 Magnet Current, Imag = 99.988263 A Vtrans = 0.999775 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:02:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041755838 Vs 17:02:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041724201 Vs 17:02:37 Magnet Current, Imag = 99.977679 A Vtrans = 0.999669 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:02:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041741496 Vs 17:03:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041746340 Vs 17:03:14 Magnet Current, Imag = 99.978203 A Vtrans = 0.999674 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:03:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041767174 Vs 17:03:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041687704 Vs 17:03:52 Magnet Current, Imag = 99.977590 A Vtrans = 0.999668 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:04:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041675242 Vs 17:04:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041697149 Vs 17:04:29 Magnet Current, Imag = 99.975254 A Vtrans = 0.999645 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:04:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041686279 Vs 17:05:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.041760491 Vs 17:05:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.041724191 +- 0.000020467 Vs 17:05:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.041724191 +- 0.000020467 Vs BL = 0.41724191 +- 0.00020467 Tm 17:05:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.41724 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.41724 0.00020 0.41724 0.00000 17:05:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.41724 0.00020 SL = 0.4172419 +- 0.0002047 Tm^2/m^n 17:05:14 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4172419 +- 0.0002047 Tm^2/m^n 17:05:15 Magnet Current, Imag = 99.992603 A Vtrans = 0.999818 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:05:15 Magnet Current, Imag = 99.996216 A Vtrans = 0.999855 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:05:16 Magnet Current, Imag = 99.983833 A Vtrans = 0.999731 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:05:17 Magnet Current, Imag = 99.968730 A Vtrans = 0.999580 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:05:17 Magnet Current Measurement: Imag = 99.9853 +- 0.0106 A 17:05:17 Magnet current ramping to 125.0000 A... 17:05:40 Magnetic Field Measurement Measuring the magnet strength... 17:05:40 Integrated Voltage Measurement... 17:05:41 Magnet Current, Imag = 124.852418 A Vtrans = 1.248417 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:06:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051956152 Vs 17:06:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051902039 Vs 17:06:19 Magnet Current, Imag = 124.863018 A Vtrans = 1.248523 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:06:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051935051 Vs 17:06:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051906161 Vs 17:06:56 Magnet Current, Imag = 124.888938 A Vtrans = 1.248782 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:07:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051909840 Vs 17:07:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.052037293 Vs 17:07:33 Magnet Current, Imag = 124.857008 A Vtrans = 1.248463 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:07:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051980996 Vs 17:08:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051895067 Vs 17:08:10 Magnet Current, Imag = 124.871058 A Vtrans = 1.248603 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:08:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051877782 Vs 17:08:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051915477 Vs 17:08:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051931586 +- 0.000025110 Vs 17:08:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.051931586 +- 0.000025110 Vs BL = 0.51931586 +- 0.00025110 Tm 17:08:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.51932 0.00025 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.51932 0.00025 0.51932 0.00000 17:08:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.51932 0.00025 SL = 0.5193159 +- 0.0002511 Tm^2/m^n 17:08:56 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5193159 +- 0.0002511 Tm^2/m^n Remeasure 17:08:56 Magnetic Field Measurement Measuring the magnet strength... 17:08:56 Integrated Voltage Measurement... 17:08:56 Magnet Current, Imag = 124.869268 A Vtrans = 1.248585 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:09:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051923578 Vs 17:09:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051932181 Vs 17:09:34 Magnet Current, Imag = 124.861098 A Vtrans = 1.248503 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:09:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.052023746 Vs 17:10:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051975386 Vs 17:10:11 Magnet Current, Imag = 124.860208 A Vtrans = 1.248495 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:10:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.052017348 Vs 17:10:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051985178 Vs 17:10:48 Magnet Current, Imag = 124.853308 A Vtrans = 1.248425 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:11:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051960837 Vs 17:11:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051916756 Vs 17:11:26 Magnet Current, Imag = 124.862888 A Vtrans = 1.248521 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:11:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051888200 Vs 17:12:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051900818 Vs 17:12:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051952403 +- 0.000041833 Vs 17:12:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.051952403 +- 0.000041833 Vs BL = 0.51952403 +- 0.00041833 Tm 17:12:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.51952 0.00042 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.51952 0.00042 0.51952 0.00000 17:12:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.51952 0.00042 SL = 0.5195240 +- 0.0004183 Tm^2/m^n 17:12:11 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5195240 +- 0.0004183 Tm^2/m^n 17:12:11 Magnet Current, Imag = 124.869268 A Vtrans = 1.248585 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:12:12 Magnet Current, Imag = 124.862508 A Vtrans = 1.248517 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:12:13 Magnet Current, Imag = 124.858288 A Vtrans = 1.248475 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:12:13 Magnet Current, Imag = 124.872078 A Vtrans = 1.248613 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:12:13 Magnet Current Measurement: Imag = 124.8655 +- 0.0054 A Remeasure 17:12:13 Magnetic Field Measurement Measuring the magnet strength... 17:12:13 Integrated Voltage Measurement... 17:12:14 Magnet Current, Imag = 124.864418 A Vtrans = 1.248537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:12:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051929709 Vs 17:12:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051912134 Vs 17:12:52 Magnet Current, Imag = 124.882428 A Vtrans = 1.248717 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:13:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051894913 Vs 17:13:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.052209177 Vs 17:13:29 Magnet Current, Imag = 124.853178 A Vtrans = 1.248424 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:13:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051852950 Vs 17:14:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051902849 Vs 17:14:06 Magnet Current, Imag = 124.866338 A Vtrans = 1.248556 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:14:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051909738 Vs 17:14:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.052015995 Vs 17:14:44 Magnet Current, Imag = 124.867738 A Vtrans = 1.248570 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:15:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051842387 Vs 17:15:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.051898590 Vs 17:15:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.051936844 +- 0.000066452 Vs 17:15:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.051936844 +- 0.000066452 Vs BL = 0.51936844 +- 0.00066452 Tm 17:15:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.51937 0.00066 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.51937 0.00066 0.51937 0.00000 17:15:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.51937 0.00066 SL = 0.5193684 +- 0.0006645 Tm^2/m^n 17:15:29 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5193684 +- 0.0006645 Tm^2/m^n 17:15:29 Magnet Current, Imag = 124.873358 A Vtrans = 1.248626 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:15:30 Magnet Current, Imag = 124.868248 A Vtrans = 1.248575 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:15:31 Magnet Current, Imag = 124.880128 A Vtrans = 1.248694 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:15:31 Magnet Current, Imag = 124.874258 A Vtrans = 1.248635 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:15:31 Magnet Current Measurement: Imag = 124.8740 +- 0.0042 A 17:15:31 Magnet current ramping to 150.0000 A... 17:15:55 Magnetic Field Measurement Measuring the magnet strength... 17:15:55 Integrated Voltage Measurement... 17:15:56 Magnet Current, Imag = 150.070708 A Vtrans = 1.500600 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:16:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062574325 Vs 17:16:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.062194044 Vs 17:16:34 Magnet Current, Imag = 150.065598 A Vtrans = 1.500548 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:16:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062332372 Vs 17:17:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.062265007 Vs 17:17:11 Magnet Current, Imag = 150.084758 A Vtrans = 1.500740 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:17:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062285572 Vs 17:17:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.062308689 Vs 17:17:48 Magnet Current, Imag = 150.090498 A Vtrans = 1.500797 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:18:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062326396 Vs 17:18:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.062376626 Vs 17:18:25 Magnet Current, Imag = 150.081438 A Vtrans = 1.500707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:18:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062292488 Vs 17:19:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.062320149 Vs 17:19:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062327567 +- 0.000034614 Vs 17:19:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.062327567 +- 0.000034614 Vs BL = 0.62327567 +- 0.00034614 Tm 17:19:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.62328 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.62328 0.00035 0.62328 0.00000 17:19:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.62328 0.00035 SL = 0.6232757 +- 0.0003461 Tm^2/m^n 17:19:10 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6232757 +- 0.0003461 Tm^2/m^n Remeasure 17:19:10 Magnetic Field Measurement Measuring the magnet strength... 17:19:10 Integrated Voltage Measurement... 17:19:11 Magnet Current, Imag = 150.065088 A Vtrans = 1.500543 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:19:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062284381 Vs 17:19:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.062395130 Vs 17:19:49 Magnet Current, Imag = 150.099698 A Vtrans = 1.500889 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:20:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062241422 Vs 17:20:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.062277597 Vs 17:20:26 Magnet Current, Imag = 150.076458 A Vtrans = 1.500657 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:20:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062322930 Vs 17:21:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.062357708 Vs 17:21:03 Magnet Current, Imag = 150.064828 A Vtrans = 1.500541 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:21:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062230146 Vs 17:21:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.062295878 Vs 17:21:40 Magnet Current, Imag = 150.087058 A Vtrans = 1.500763 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:21:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062269633 Vs 17:22:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.062301124 Vs 17:22:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.062297595 +- 0.000035773 Vs 17:22:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.062297595 +- 0.000035773 Vs BL = 0.62297595 +- 0.00035773 Tm 17:22:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.62298 0.00036 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.62298 0.00036 0.62298 0.00000 17:22:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.62298 0.00036 SL = 0.6229759 +- 0.0003577 Tm^2/m^n 17:22:25 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6229759 +- 0.0003577 Tm^2/m^n 17:22:26 Magnet Current, Imag = 150.084248 A Vtrans = 1.500735 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:22:27 Magnet Current, Imag = 150.088588 A Vtrans = 1.500778 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:22:27 Magnet Current, Imag = 150.100588 A Vtrans = 1.500898 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:22:28 Magnet Current, Imag = 150.097138 A Vtrans = 1.500864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:22:28 Magnet Current Measurement: Imag = 150.0926 +- 0.0065 A 17:22:28 Magnet current ramping to 175.0000 A... 17:22:52 Magnetic Field Measurement Measuring the magnet strength... 17:22:52 Integrated Voltage Measurement... 17:22:53 Magnet Current, Imag = 174.968038 A Vtrans = 1.749573 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:23:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072570973 Vs 17:23:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.072467800 Vs 17:23:30 Magnet Current, Imag = 174.981958 A Vtrans = 1.749712 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:23:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072557199 Vs 17:24:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.072636836 Vs 17:24:08 Magnet Current, Imag = 174.999838 A Vtrans = 1.749891 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:24:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072539055 Vs 17:24:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.072629190 Vs 17:24:45 Magnet Current, Imag = 174.965098 A Vtrans = 1.749543 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:25:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072525213 Vs 17:25:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.072491917 Vs 17:25:22 Magnet Current, Imag = 174.963828 A Vtrans = 1.749531 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:25:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072548580 Vs 17:25:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.072576581 Vs 17:25:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072554335 +- 0.000034910 Vs 17:25:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.072554335 +- 0.000034910 Vs BL = 0.72554335 +- 0.00034910 Tm 17:26:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.72554 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.72554 0.00035 0.72554 0.00000 17:26:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.72554 0.00035 SL = 0.7255433 +- 0.0003491 Tm^2/m^n 17:26:07 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7255433 +- 0.0003491 Tm^2/m^n Remeasure 17:26:07 Magnetic Field Measurement Measuring the magnet strength... 17:26:07 Integrated Voltage Measurement... 17:26:08 Magnet Current, Imag = 174.980428 A Vtrans = 1.749697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:26:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072588494 Vs 17:26:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.072521345 Vs 17:26:45 Magnet Current, Imag = 174.976848 A Vtrans = 1.749661 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:27:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072536832 Vs 17:27:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.072537662 Vs 17:27:23 Magnet Current, Imag = 174.996138 A Vtrans = 1.749854 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:27:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072641304 Vs 17:27:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.072495094 Vs 17:28:00 Magnet Current, Imag = 174.958078 A Vtrans = 1.749473 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:28:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072547401 Vs 17:28:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.072522722 Vs 17:28:37 Magnet Current, Imag = 174.982978 A Vtrans = 1.749722 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:28:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072559789 Vs 17:29:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.072550071 Vs 17:29:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.072550071 +- 0.000012373 Vs 17:29:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.072550071 +- 0.000012373 Vs BL = 0.72550071 +- 0.00012373 Tm 17:29:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.72550 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.72550 0.00012 0.72550 0.00000 17:29:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.72550 0.00012 SL = 0.7255007 +- 0.0001237 Tm^2/m^n 17:29:22 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7255007 +- 0.0001237 Tm^2/m^n 17:29:23 Magnet Current, Imag = 174.995628 A Vtrans = 1.749849 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:29:23 Magnet Current, Imag = 174.992688 A Vtrans = 1.749819 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:29:24 Magnet Current, Imag = 174.967018 A Vtrans = 1.749563 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:29:25 Magnet Current, Imag = 174.978768 A Vtrans = 1.749680 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:29:25 Magnet Current Measurement: Imag = 174.9835 +- 0.0115 A 17:29:25 Magnet current ramping to 200.0000 A... 17:29:49 Magnetic Field Measurement Measuring the magnet strength... 17:29:49 Integrated Voltage Measurement... 17:29:49 Magnet Current, Imag = 199.856448 A Vtrans = 1.998457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:30:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082702611 Vs 17:30:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.082801492 Vs 17:30:27 Magnet Current, Imag = 199.885058 A Vtrans = 1.998743 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:30:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082772642 Vs 17:31:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.082687567 Vs 17:31:04 Magnet Current, Imag = 199.886718 A Vtrans = 1.998760 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:31:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082742866 Vs 17:31:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.082773224 Vs 17:31:42 Magnet Current, Imag = 199.895908 A Vtrans = 1.998852 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:32:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082785169 Vs 17:32:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.082779217 Vs 17:32:19 Magnet Current, Imag = 199.884928 A Vtrans = 1.998742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:32:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082838840 Vs 17:32:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.082838050 Vs 17:32:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082772168 +- 0.000037058 Vs 17:32:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.082772168 +- 0.000037058 Vs BL = 0.82772168 +- 0.00037058 Tm 17:33:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.82772 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.82772 0.00037 0.82772 0.00000 17:33:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.82772 0.00037 SL = 0.8277217 +- 0.0003706 Tm^2/m^n 17:33:04 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8277217 +- 0.0003706 Tm^2/m^n Remeasure 17:33:04 Magnetic Field Measurement Measuring the magnet strength... 17:33:04 Integrated Voltage Measurement... 17:33:04 Magnet Current, Imag = 199.897188 A Vtrans = 1.998864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:33:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082843049 Vs 17:33:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.082740458 Vs 17:33:42 Magnet Current, Imag = 199.875738 A Vtrans = 1.998650 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:34:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082816790 Vs 17:34:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.082704679 Vs 17:34:19 Magnet Current, Imag = 199.879948 A Vtrans = 1.998692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:34:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082795105 Vs 17:34:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.082735490 Vs 17:34:57 Magnet Current, Imag = 199.876628 A Vtrans = 1.998659 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:35:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082797178 Vs 17:35:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.082762711 Vs 17:35:34 Magnet Current, Imag = 199.886208 A Vtrans = 1.998754 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:35:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082744631 Vs 17:36:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.082841582 Vs 17:36:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.082778167 +- 0.000013270 Vs 17:36:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.082778167 +- 0.000013270 Vs BL = 0.82778167 +- 0.00013270 Tm 17:36:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.82778 0.00013 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.82778 0.00013 0.82778 0.00000 17:36:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.82778 0.00013 SL = 0.8277817 +- 0.0001327 Tm^2/m^n 17:36:19 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8277817 +- 0.0001327 Tm^2/m^n 17:36:19 Magnet Current, Imag = 199.894638 A Vtrans = 1.998839 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:36:20 Magnet Current, Imag = 199.891058 A Vtrans = 1.998803 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:36:21 Magnet Current, Imag = 199.877008 A Vtrans = 1.998663 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:36:22 Magnet Current, Imag = 199.866798 A Vtrans = 1.998560 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:36:22 Magnet Current Measurement: Imag = 199.8824 +- 0.0111 A 17:36:22 Magnet current ramping to 225.0000 A... 17:36:45 Magnetic Field Measurement Measuring the magnet strength... 17:36:45 Integrated Voltage Measurement... 17:36:46 Magnet Current, Imag = 225.084818 A Vtrans = 2.250741 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:37:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.093055285 Vs 17:37:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.093055964 Vs 17:37:24 Magnet Current, Imag = 225.103088 A Vtrans = 2.250923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:37:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.093055660 Vs 17:38:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.093184583 Vs 17:38:01 Magnet Current, Imag = 225.083548 A Vtrans = 2.250728 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:38:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.092987457 Vs 17:38:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.093111998 Vs 17:38:38 Magnet Current, Imag = 225.101808 A Vtrans = 2.250910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:38:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.093054032 Vs 17:39:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.093079618 Vs 17:39:15 Magnet Current, Imag = 225.094398 A Vtrans = 2.250836 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:39:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.093138232 Vs 17:39:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.093035639 Vs 17:39:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.093075847 +- 0.000025518 Vs 17:39:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.093075847 +- 0.000025518 Vs BL = 0.93075847 +- 0.00025518 Tm 17:40:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.93076 0.00026 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.93076 0.00026 0.93076 0.00000 17:40:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.93076 0.00026 SL = 0.9307585 +- 0.0002552 Tm^2/m^n 17:40:00 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9307585 +- 0.0002552 Tm^2/m^n 17:40:00 Magnet current ramping to 250.0000 A... 17:40:24 Magnetic Field Measurement Measuring the magnet strength... 17:40:24 Integrated Voltage Measurement... 17:40:25 Magnet Current, Imag = 250.017128 A Vtrans = 2.500064 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:40:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.103139646 Vs 17:41:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.103229771 Vs 17:41:03 Magnet Current, Imag = 249.997968 A Vtrans = 2.499872 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:41:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.103181097 Vs 17:41:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.103188719 Vs 17:41:40 Magnet Current, Imag = 249.992988 A Vtrans = 2.499822 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:41:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.103287654 Vs 17:42:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.103174958 Vs 17:42:17 Magnet Current, Imag = 250.007038 A Vtrans = 2.499963 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:42:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.103173374 Vs 17:42:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.103179629 Vs 17:42:54 Magnet Current, Imag = 249.975998 A Vtrans = 2.499652 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:43:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.103291407 Vs 17:43:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.103192942 Vs 17:43:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.103203920 +- 0.000027187 Vs 17:43:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.103203920 +- 0.000027187 Vs BL = 1.03203920 +- 0.00027187 Tm 17:43:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.03204 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 1.03204 0.00027 1.03204 0.00000 17:43:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.03204 0.00027 SL = 1.0320392 +- 0.0002719 Tm^2/m^n 17:43:39 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0320392 +- 0.0002719 Tm^2/m^n 17:43:39 Magnet current ramping to 275.0000 A... 17:44:03 Magnetic Field Measurement Measuring the magnet strength... 17:44:03 Integrated Voltage Measurement... 17:44:04 Magnet Current, Imag = 274.883958 A Vtrans = 2.748732 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:44:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.113259723 Vs 17:44:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.113311852 Vs 17:44:41 Magnet Current, Imag = 274.907198 A Vtrans = 2.748964 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:45:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.113343067 Vs 17:45:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.113395213 Vs 17:45:19 Magnet Current, Imag = 274.889318 A Vtrans = 2.748786 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:45:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.113265017 Vs 17:45:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.113307013 Vs 17:45:56 Magnet Current, Imag = 274.893408 A Vtrans = 2.748826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:46:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.113290251 Vs 17:46:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.113206750 Vs 17:46:33 Magnet Current, Imag = 274.916388 A Vtrans = 2.749056 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:46:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.113320320 Vs 17:47:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.113293242 Vs 17:47:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.113299245 +- 0.000039682 Vs 17:47:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.113299245 +- 0.000039682 Vs BL = 1.13299245 +- 0.00039682 Tm 17:47:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.13299 0.00040 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 1.13299 0.00040 1.13299 0.00000 17:47:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.13299 0.00040 SL = 1.1329924 +- 0.0003968 Tm^2/m^n 17:47:18 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1329924 +- 0.0003968 Tm^2/m^n 17:47:18 Magnet current ramping to 300.0000 A... 17:47:42 Magnetic Field Measurement Measuring the magnet strength... 17:47:42 Integrated Voltage Measurement... 17:47:43 Magnet Current, Imag = 300.096228 A Vtrans = 3.000855 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:48:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.123489964 Vs 17:48:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.123493612 Vs 17:48:20 Magnet Current, Imag = 300.098528 A Vtrans = 3.000878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:48:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.123449897 Vs 17:48:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.123392345 Vs 17:48:57 Magnet Current, Imag = 300.093808 A Vtrans = 3.000831 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:49:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.123484657 Vs 17:49:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.123418514 Vs 17:49:35 Magnet Current, Imag = 300.103388 A Vtrans = 3.000926 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:49:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.123472680 Vs 17:50:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.123411025 Vs 17:50:12 Magnet Current, Imag = 300.093298 A Vtrans = 3.000825 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:50:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.123483373 Vs 17:50:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.123435500 Vs 17:50:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.123453157 +- 0.000023188 Vs 17:50:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.123453157 +- 0.000023188 Vs BL = 1.23453157 +- 0.00023188 Tm 17:50:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.23453 0.00023 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 1.23453 0.00023 1.23453 0.00000 17:50:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.23453 0.00023 SL = 1.2345316 +- 0.0002319 Tm^2/m^n 17:50:57 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2345316 +- 0.0002319 Tm^2/m^n 17:50:57 Magnet current ramping to 325.0000 A... 17:51:21 Magnetic Field Measurement Measuring the magnet strength... 17:51:21 Integrated Voltage Measurement... 17:51:21 Magnet Current, Imag = 324.972218 A Vtrans = 3.249615 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:51:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.133340695 Vs 17:51:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.133391820 Vs 17:51:59 Magnet Current, Imag = 324.958548 A Vtrans = 3.249478 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:52:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.133362258 Vs 17:52:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.133365618 Vs 17:52:36 Magnet Current, Imag = 324.972978 A Vtrans = 3.249622 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:52:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.133305921 Vs 17:53:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.133310069 Vs 17:53:14 Magnet Current, Imag = 324.986898 A Vtrans = 3.249761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:53:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.133356409 Vs 17:53:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.133262552 Vs 17:53:51 Magnet Current, Imag = 324.990738 A Vtrans = 3.249800 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:54:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.133367179 Vs 17:54:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.133384373 Vs 17:54:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.133344689 +- 0.000029625 Vs 17:54:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.133344689 +- 0.000029625 Vs BL = 1.33344689 +- 0.00029625 Tm 17:54:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.33345 0.00030 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 1.33345 0.00030 1.33345 0.00000 17:54:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.33345 0.00030 SL = 1.3334469 +- 0.0002962 Tm^2/m^n 17:54:36 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3334469 +- 0.0002962 Tm^2/m^n 17:54:36 Magnet current ramping to 350.0000 A... 17:54:59 Magnetic Field Measurement Measuring the magnet strength... 17:54:59 Integrated Voltage Measurement... 17:55:00 Magnet Current, Imag = 349.881438 A Vtrans = 3.498707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:55:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.143127141 Vs 17:55:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.143213147 Vs 17:55:38 Magnet Current, Imag = 349.883218 A Vtrans = 3.498725 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:55:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.143174848 Vs 17:56:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.143081657 Vs 17:56:15 Magnet Current, Imag = 349.887438 A Vtrans = 3.498767 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:56:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.143108963 Vs 17:56:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.143084003 Vs 17:56:52 Magnet Current, Imag = 349.880288 A Vtrans = 3.498695 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:57:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.143103266 Vs 17:57:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.143136220 Vs 17:57:30 Magnet Current, Imag = 349.886928 A Vtrans = 3.498762 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:57:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.143154973 Vs 17:58:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.143108539 Vs 17:58:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.143129276 +- 0.000023848 Vs 17:58:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.143129276 +- 0.000023848 Vs BL = 1.43129276 +- 0.00023848 Tm 17:58:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43129 0.00024 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 1.43129 0.00024 1.43129 0.00000 17:58:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43129 0.00024 SL = 1.4312928 +- 0.0002385 Tm^2/m^n 17:58:15 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4312928 +- 0.0002385 Tm^2/m^n 17:58:15 Magnet current ramping to 400.0000 A... 17:58:42 Magnetic Field Measurement Measuring the magnet strength... 17:58:42 Integrated Voltage Measurement... 17:58:42 Magnet Current, Imag = 400.013918 A Vtrans = 4.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:59:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.162166983 Vs 17:59:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.162193412 Vs 17:59:20 Magnet Current, Imag = 400.002418 A Vtrans = 3.999917 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 17:59:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.162140566 Vs 17:59:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.162142835 Vs 17:59:57 Magnet Current, Imag = 399.988118 A Vtrans = 3.999774 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:00:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.162184672 Vs 18:00:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.162249165 Vs 18:00:35 Magnet Current, Imag = 399.997438 A Vtrans = 3.999867 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:00:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.162246966 Vs 18:01:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.162091324 Vs 18:01:12 Magnet Current, Imag = 400.011748 A Vtrans = 4.000010 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:01:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.162226560 Vs 18:01:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.162183159 Vs 18:01:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.162182564 +- 0.000026581 Vs 18:01:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.162182564 +- 0.000026581 Vs BL = 1.62182564 +- 0.00026581 Tm 18:01:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.62183 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 1.62183 0.00027 1.62183 0.00000 18:01:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.62183 0.00027 SL = 1.6218256 +- 0.0002658 Tm^2/m^n 18:01:57 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6218256 +- 0.0002658 Tm^2/m^n 18:01:57 Magnet current ramping to 425.0000 A... 18:02:21 Magnetic Field Measurement Measuring the magnet strength... 18:02:21 Integrated Voltage Measurement... 18:02:21 Magnet Current, Imag = 424.890058 A Vtrans = 4.248793 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:02:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.171068375 Vs 18:02:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.171095509 Vs 18:02:59 Magnet Current, Imag = 424.932838 A Vtrans = 4.249221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:03:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.171094422 Vs 18:03:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.171021251 Vs 18:03:36 Magnet Current, Imag = 424.937698 A Vtrans = 4.249269 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:03:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.171014036 Vs 18:04:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.171129178 Vs 18:04:13 Magnet Current, Imag = 424.908828 A Vtrans = 4.248981 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:04:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.170998164 Vs 18:04:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.170984197 Vs 18:04:51 Magnet Current, Imag = 424.921088 A Vtrans = 4.249103 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:05:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.171113728 Vs 18:05:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.171012297 Vs 18:05:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.171053116 +- 0.000032028 Vs 18:05:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.171053116 +- 0.000032028 Vs BL = 1.71053116 +- 0.00032028 Tm 18:05:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.71053 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 1.71053 0.00032 1.71053 0.00000 18:05:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.71053 0.00032 SL = 1.7105312 +- 0.0003203 Tm^2/m^n 18:05:36 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7105312 +- 0.0003203 Tm^2/m^n 18:05:36 Magnet current ramping to 450.0000 A... 18:05:59 Magnetic Field Measurement Measuring the magnet strength... 18:05:59 Integrated Voltage Measurement... 18:06:00 Magnet Current, Imag = 450.143948 A Vtrans = 4.501332 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:06:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.179499737 Vs 18:06:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.179524587 Vs 18:06:38 Magnet Current, Imag = 450.133098 A Vtrans = 4.501223 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:06:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.179542144 Vs 18:07:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.179464510 Vs 18:07:15 Magnet Current, Imag = 450.135138 A Vtrans = 4.501244 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:07:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.179514043 Vs 18:07:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.179485686 Vs 18:07:52 Magnet Current, Imag = 450.141908 A Vtrans = 4.501311 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:08:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.179527147 Vs 18:08:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.179539681 Vs 18:08:30 Magnet Current, Imag = 450.144078 A Vtrans = 4.501333 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:08:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.179558419 Vs 18:09:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.179486639 Vs 18:09:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.179514259 +- 0.000012381 Vs 18:09:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.179514259 +- 0.000012381 Vs BL = 1.79514259 +- 0.00012381 Tm 18:09:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.79514 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 1.79514 0.00012 1.79514 0.00000 18:09:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.79514 0.00012 SL = 1.7951426 +- 0.0001238 Tm^2/m^n 18:09:15 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7951426 +- 0.0001238 Tm^2/m^n 18:09:15 Magnet current ramping to 475.0000 A... 18:09:38 Magnetic Field Measurement Measuring the magnet strength... 18:09:38 Integrated Voltage Measurement... 18:09:39 Magnet Current, Imag = 475.028008 A Vtrans = 4.750172 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:09:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.187353723 Vs 18:10:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.187434410 Vs 18:10:17 Magnet Current, Imag = 475.020988 A Vtrans = 4.750102 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:10:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.187326343 Vs 18:10:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.187343391 Vs 18:10:54 Magnet Current, Imag = 475.029798 A Vtrans = 4.750190 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:11:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.187405030 Vs 18:11:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.187380452 Vs 18:11:31 Magnet Current, Imag = 475.025838 A Vtrans = 4.750151 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:11:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.187385877 Vs 18:12:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.187388555 Vs 18:12:08 Magnet Current, Imag = 475.009488 A Vtrans = 4.749987 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:12:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.187299848 Vs 18:12:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.187352505 Vs 18:12:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.187367013 +- 0.000030010 Vs 18:12:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.187367013 +- 0.000030010 Vs BL = 1.87367013 +- 0.00030010 Tm 18:12:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.87367 0.00030 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 1.87367 0.00030 1.87367 0.00000 18:12:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.87367 0.00030 SL = 1.8736701 +- 0.0003001 Tm^2/m^n 18:12:53 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8736701 +- 0.0003001 Tm^2/m^n 18:12:53 Magnet current ramping to 500.0000 A... 18:13:17 Magnetic Field Measurement Measuring the magnet strength... 18:13:17 Integrated Voltage Measurement... 18:13:18 Magnet Current, Imag = 499.924688 A Vtrans = 4.999139 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:13:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.194563552 Vs 18:13:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.194755375 Vs 18:13:56 Magnet Current, Imag = 499.929678 A Vtrans = 4.999189 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:14:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.194634358 Vs 18:14:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.194528544 Vs 18:14:33 Magnet Current, Imag = 499.919838 A Vtrans = 4.999091 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:14:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.194561672 Vs 18:15:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.194564921 Vs 18:15:10 Magnet Current, Imag = 499.909878 A Vtrans = 4.998991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:15:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.194644634 Vs 18:15:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.194650254 Vs 18:15:48 Magnet Current, Imag = 499.922008 A Vtrans = 4.999112 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:16:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.194553533 Vs 18:16:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.194549965 Vs 18:16:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.194600681 +- 0.000044281 Vs 18:16:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.194600681 +- 0.000044281 Vs BL = 1.94600681 +- 0.00044281 Tm 18:16:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.94601 0.00044 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 1.94601 0.00044 1.94601 0.00000 18:16:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.94601 0.00044 SL = 1.9460068 +- 0.0004428 Tm^2/m^n 18:16:33 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9460068 +- 0.0004428 Tm^2/m^n 18:16:33 Magnet current ramping to 525.0000 A... 18:16:56 Magnetic Field Measurement Measuring the magnet strength... 18:16:56 Integrated Voltage Measurement... 18:16:57 Magnet Current, Imag = 525.135948 A Vtrans = 5.251252 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:17:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.201186700 Vs 18:17:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.201224537 Vs 18:17:35 Magnet Current, Imag = 525.136718 A Vtrans = 5.251260 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:17:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.201219875 Vs 18:18:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.201172893 Vs 18:18:12 Magnet Current, Imag = 525.153318 A Vtrans = 5.251426 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:18:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.201213936 Vs 18:18:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.201191417 Vs 18:18:49 Magnet Current, Imag = 525.151788 A Vtrans = 5.251410 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:19:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.201157336 Vs 18:19:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.201191060 Vs 18:19:26 Magnet Current, Imag = 525.150638 A Vtrans = 5.251399 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:19:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.201192233 Vs 18:20:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.201255346 Vs 18:20:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.201200533 +- 0.000016013 Vs 18:20:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.201200533 +- 0.000016013 Vs BL = 2.01200533 +- 0.00016013 Tm 18:20:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.01201 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.01201 0.00016 2.01201 0.00000 18:20:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.01201 0.00016 SL = 2.0120053 +- 0.0001601 Tm^2/m^n 18:20:11 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0120053 +- 0.0001601 Tm^2/m^n 18:20:11 Magnet current ramping to 550.0000 A... 18:20:35 Magnetic Field Measurement Measuring the magnet strength... 18:20:35 Integrated Voltage Measurement... 18:20:36 Magnet Current, Imag = 550.043258 A Vtrans = 5.500325 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:20:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.207134477 Vs 18:21:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.207140018 Vs 18:21:14 Magnet Current, Imag = 550.019758 A Vtrans = 5.500090 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:21:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.207200349 Vs 18:21:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.207162114 Vs 18:21:51 Magnet Current, Imag = 550.048618 A Vtrans = 5.500379 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:22:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.207152249 Vs 18:22:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.207217520 Vs 18:22:28 Magnet Current, Imag = 550.065348 A Vtrans = 5.500546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:22:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.207188013 Vs 18:23:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.207161108 Vs 18:23:05 Magnet Current, Imag = 550.037888 A Vtrans = 5.500271 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:23:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.207177293 Vs 18:23:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.207166585 Vs 18:23:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.207169973 +- 0.000017000 Vs 18:23:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.207169973 +- 0.000017000 Vs BL = 2.07169973 +- 0.00017000 Tm 18:23:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.07170 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.07170 0.00017 2.07170 0.00000 18:23:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.07170 0.00017 SL = 2.0716997 +- 0.0001700 Tm^2/m^n 18:23:50 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0716997 +- 0.0001700 Tm^2/m^n 18:23:50 Magnet current ramping to 575.0000 A... 18:24:14 Magnetic Field Measurement Measuring the magnet strength... 18:24:14 Integrated Voltage Measurement... 18:24:15 Magnet Current, Imag = 574.936358 A Vtrans = 5.749256 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:24:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.212594006 Vs 18:24:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.212607428 Vs 18:24:52 Magnet Current, Imag = 574.949008 A Vtrans = 5.749383 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:25:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.212586197 Vs 18:25:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.212590921 Vs 18:25:30 Magnet Current, Imag = 574.925758 A Vtrans = 5.749150 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:25:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.212593205 Vs 18:26:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.212559731 Vs 18:26:07 Magnet Current, Imag = 574.932528 A Vtrans = 5.749218 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:26:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.212598468 Vs 18:26:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.212598444 Vs 18:26:44 Magnet Current, Imag = 574.946448 A Vtrans = 5.749357 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:27:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.212629688 Vs 18:27:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.212610499 Vs 18:27:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.212596859 +- 0.000014436 Vs 18:27:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.212596859 +- 0.000014436 Vs BL = 2.12596859 +- 0.00014436 Tm 18:27:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.12597 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.12597 0.00014 2.12597 0.00000 18:27:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.12597 0.00014 SL = 2.1259686 +- 0.0001444 Tm^2/m^n 18:27:29 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1259686 +- 0.0001444 Tm^2/m^n 18:27:29 Magnet current ramping to 600.0000 A... 18:27:53 Magnetic Field Measurement Measuring the magnet strength... 18:27:53 Integrated Voltage Measurement... 18:27:53 Magnet Current, Imag = 600.105598 A Vtrans = 6.000948 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:28:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.217632921 Vs 18:28:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.217534396 Vs 18:28:31 Magnet Current, Imag = 600.120418 A Vtrans = 6.001097 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:28:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.217609869 Vs 18:29:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.217601902 Vs 18:29:08 Magnet Current, Imag = 600.110968 A Vtrans = 6.001002 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:29:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.217575629 Vs 18:29:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.217579724 Vs 18:29:46 Magnet Current, Imag = 600.131658 A Vtrans = 6.001209 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:30:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.217596129 Vs 18:30:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.217650195 Vs 18:30:23 Magnet Current, Imag = 600.130508 A Vtrans = 6.001197 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:30:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.217568701 Vs 18:30:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.217564189 Vs 18:30:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.217591365 +- 0.000020443 Vs 18:30:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.217591365 +- 0.000020443 Vs BL = 2.17591365 +- 0.00020443 Tm 18:31:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17591 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.17591 0.00020 2.17591 0.00000 18:31:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17591 0.00020 SL = 2.1759137 +- 0.0002044 Tm^2/m^n 18:31:08 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1759137 +- 0.0002044 Tm^2/m^n 18:31:08 Magnet current ramping to 620.0000 A... 18:31:31 Magnetic Field Measurement Measuring the magnet strength... 18:31:31 Integrated Voltage Measurement... 18:31:32 Magnet Current, Imag = 620.237348 A Vtrans = 6.202266 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:31:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.221230875 Vs 18:32:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.221323907 Vs 18:32:09 Magnet Current, Imag = 620.237218 A Vtrans = 6.202265 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:32:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.221258691 Vs 18:32:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.221311295 Vs 18:32:47 Magnet Current, Imag = 620.262498 A Vtrans = 6.202517 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:33:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.221312696 Vs 18:33:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.221226716 Vs 18:33:24 Magnet Current, Imag = 620.241938 A Vtrans = 6.202312 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:33:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.221231568 Vs 18:34:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.221367931 Vs 18:34:01 Magnet Current, Imag = 620.269908 A Vtrans = 6.202591 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:34:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.221194496 Vs 18:34:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.221215270 Vs 18:34:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.221267344 +- 0.000032771 Vs 18:34:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.221267344 +- 0.000032771 Vs BL = 2.21267344 +- 0.00032771 Tm 18:34:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.21267 0.00033 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.21267 0.00033 2.21267 0.00000 18:34:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.21267 0.00033 SL = 2.2126734 +- 0.0003277 Tm^2/m^n 18:34:46 Magnet Strength Measurement Harmonic Number = 1 SL = 2.2126734 +- 0.0003277 Tm^2/m^n 18:34:46 Magnet current ramping to 640.0000 A... 18:35:09 Magnetic Field Measurement Measuring the magnet strength... 18:35:09 Integrated Voltage Measurement... 18:35:10 Magnet Current, Imag = 640.094388 A Vtrans = 6.400836 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:35:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.224619052 Vs 18:35:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.224593231 Vs 18:35:48 Magnet Current, Imag = 640.094258 A Vtrans = 6.400835 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:36:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.224587170 Vs 18:36:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.224595759 Vs 18:36:25 Magnet Current, Imag = 640.080598 A Vtrans = 6.400698 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:36:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.224606827 Vs 18:37:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.224609276 Vs 18:37:02 Magnet Current, Imag = 640.084938 A Vtrans = 6.400742 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:37:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.224561404 Vs 18:37:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.224645652 Vs 18:37:39 Magnet Current, Imag = 640.077148 A Vtrans = 6.400664 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:37:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.224625144 Vs 18:38:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.224593414 Vs 18:38:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.224603693 +- 0.000006415 Vs 18:38:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.224603693 +- 0.000006415 Vs BL = 2.24603693 +- 0.00006415 Tm 18:38:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.24604 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.24604 0.00006 2.24604 0.00000 18:38:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.24604 0.00006 SL = 2.2460369 +- 0.0000641 Tm^2/m^n 18:38:24 Magnet Strength Measurement Harmonic Number = 1 SL = 2.2460369 +- 0.0000641 Tm^2/m^n 18:38:24 Magnet current ramping to 660.0000 A... 18:38:47 Magnetic Field Measurement Measuring the magnet strength... 18:38:47 Integrated Voltage Measurement... 18:38:48 Magnet Current, Imag = 660.181568 A Vtrans = 6.601708 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:39:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.227729067 Vs 18:39:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.227801354 Vs 18:39:26 Magnet Current, Imag = 660.196508 A Vtrans = 6.601858 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:39:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.227739219 Vs 18:40:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.227711337 Vs 18:40:03 Magnet Current, Imag = 660.176458 A Vtrans = 6.601657 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:40:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.227741303 Vs 18:40:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.227812383 Vs 18:40:40 Magnet Current, Imag = 660.192678 A Vtrans = 6.601819 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:40:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.227783167 Vs 18:41:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.227721818 Vs 18:41:17 Magnet Current, Imag = 660.192298 A Vtrans = 6.601815 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:41:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.227726215 Vs 18:41:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.227720497 Vs 18:41:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.227748636 +- 0.000021307 Vs 18:41:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.227748636 +- 0.000021307 Vs BL = 2.27748636 +- 0.00021307 Tm 18:42:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.27749 0.00021 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.27749 0.00021 2.27749 0.00000 18:42:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.27749 0.00021 SL = 2.2774864 +- 0.0002131 Tm^2/m^n 18:42:02 Magnet Strength Measurement Harmonic Number = 1 SL = 2.2774864 +- 0.0002131 Tm^2/m^n 18:42:02 Magnet current ramping to 680.0000 A... 18:42:26 Magnetic Field Measurement Measuring the magnet strength... 18:42:26 Integrated Voltage Measurement... 18:42:26 Magnet Current, Imag = 680.313708 A Vtrans = 6.803030 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:42:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.230679936 Vs 18:43:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.230732894 Vs 18:43:04 Magnet Current, Imag = 680.307188 A Vtrans = 6.802964 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:43:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.230628047 Vs 18:43:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.230641626 Vs 18:43:41 Magnet Current, Imag = 680.300168 A Vtrans = 6.802894 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:43:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.230704071 Vs 18:44:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.230705833 Vs 18:44:18 Magnet Current, Imag = 680.296338 A Vtrans = 6.802856 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:44:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.230597870 Vs 18:44:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.230694630 Vs 18:44:56 Magnet Current, Imag = 680.301698 A Vtrans = 6.802909 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:45:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.230683733 Vs 18:45:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.230756605 Vs 18:45:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.230682524 +- 0.000034874 Vs 18:45:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.230682524 +- 0.000034874 Vs BL = 2.30682524 +- 0.00034874 Tm 18:45:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.30683 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.30683 0.00035 2.30683 0.00000 18:45:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.30683 0.00035 SL = 2.3068252 +- 0.0003487 Tm^2/m^n 18:45:41 Magnet Strength Measurement Harmonic Number = 1 SL = 2.3068252 +- 0.0003487 Tm^2/m^n 18:45:41 Magnet current ramping to 700.0000 A... 18:46:04 Magnetic Field Measurement Measuring the magnet strength... 18:46:04 Integrated Voltage Measurement... 18:46:04 Magnet Current, Imag = 700.107268 A Vtrans = 7.000965 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:46:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.233390524 Vs 18:46:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.233407526 Vs 18:46:42 Magnet Current, Imag = 700.121568 A Vtrans = 7.001108 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:47:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.233389440 Vs 18:47:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.233422484 Vs 18:47:19 Magnet Current, Imag = 700.148648 A Vtrans = 7.001379 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:47:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.233388083 Vs 18:47:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.233313153 Vs 18:47:57 Magnet Current, Imag = 700.097558 A Vtrans = 7.000868 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:48:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.233361789 Vs 18:48:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.233377564 Vs 18:48:34 Magnet Current, Imag = 700.098838 A Vtrans = 7.000881 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:48:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.233324564 Vs 18:49:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.233359426 Vs 18:49:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.233373455 +- 0.000025440 Vs 18:49:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.233373455 +- 0.000025440 Vs BL = 2.33373455 +- 0.00025440 Tm 18:49:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.33373 0.00025 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.33373 0.00025 2.33373 0.00000 18:49:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.33373 0.00025 SL = 2.3337346 +- 0.0002544 Tm^2/m^n 18:49:19 Magnet Strength Measurement Harmonic Number = 1 SL = 2.3337346 +- 0.0002544 Tm^2/m^n 18:49:19 Magnet current ramping to 720.0000 A... 18:49:42 Magnetic Field Measurement Measuring the magnet strength... 18:49:42 Integrated Voltage Measurement... 18:49:43 Magnet Current, Imag = 720.223958 A Vtrans = 7.202132 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:50:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.235914428 Vs 18:50:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.235852541 Vs 18:50:20 Magnet Current, Imag = 720.247588 A Vtrans = 7.202368 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:50:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.235890190 Vs 18:50:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.235907856 Vs 18:50:57 Magnet Current, Imag = 720.258698 A Vtrans = 7.202479 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:51:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.235917399 Vs 18:51:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.235928296 Vs 18:51:35 Magnet Current, Imag = 720.250908 A Vtrans = 7.202401 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:51:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.235839955 Vs 18:52:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.235915833 Vs 18:52:12 Magnet Current, Imag = 720.235578 A Vtrans = 7.202248 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:52:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.235853849 Vs 18:52:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.235941915 Vs 18:52:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.235896226 +- 0.000015606 Vs 18:52:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.235896226 +- 0.000015606 Vs BL = 2.35896226 +- 0.00015606 Tm 18:52:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.35896 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.35896 0.00016 2.35896 0.00000 18:52:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.35896 0.00016 SL = 2.3589623 +- 0.0001561 Tm^2/m^n 18:52:57 Magnet Strength Measurement Harmonic Number = 1 SL = 2.3589623 +- 0.0001561 Tm^2/m^n 18:52:57 Magnet current ramping to 740.0000 A... 18:53:20 Magnetic Field Measurement Measuring the magnet strength... 18:53:20 Integrated Voltage Measurement... 18:53:21 Magnet Current, Imag = 740.369748 A Vtrans = 7.403590 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:53:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.238293735 Vs 18:53:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.238277119 Vs 18:53:58 Magnet Current, Imag = 740.330158 A Vtrans = 7.403194 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:54:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.238232540 Vs 18:54:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.238239082 Vs 18:54:36 Magnet Current, Imag = 740.359538 A Vtrans = 7.403488 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:54:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.238236261 Vs 18:55:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.238152213 Vs 18:55:13 Magnet Current, Imag = 740.326968 A Vtrans = 7.403162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:55:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.238242544 Vs 18:55:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.238189829 Vs 18:55:50 Magnet Current, Imag = 740.316628 A Vtrans = 7.403059 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:56:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.238198939 Vs 18:56:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.238225274 Vs 18:56:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.238228754 +- 0.000031267 Vs 18:56:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.238228754 +- 0.000031267 Vs BL = 2.38228754 +- 0.00031267 Tm 18:56:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.38229 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.38229 0.00031 2.38229 0.00000 18:56:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.38229 0.00031 SL = 2.3822875 +- 0.0003127 Tm^2/m^n 18:56:35 Magnet Strength Measurement Harmonic Number = 1 SL = 2.3822875 +- 0.0003127 Tm^2/m^n 18:56:35 Magnet current ramping to 760.0000 A... 18:56:58 Magnetic Field Measurement Measuring the magnet strength... 18:56:58 Integrated Voltage Measurement... 18:56:59 Magnet Current, Imag = 760.113888 A Vtrans = 7.601031 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:57:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.240412383 Vs 18:57:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.240373342 Vs 18:57:37 Magnet Current, Imag = 760.125638 A Vtrans = 7.601149 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:57:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.240382355 Vs 18:58:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.240356868 Vs 18:58:14 Magnet Current, Imag = 760.141478 A Vtrans = 7.601307 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:58:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.240338745 Vs 18:58:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.240411189 Vs 18:58:51 Magnet Current, Imag = 760.126538 A Vtrans = 7.601158 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:59:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.240341698 Vs 18:59:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.240391087 Vs 18:59:28 Magnet Current, Imag = 760.123468 A Vtrans = 7.601127 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 18:59:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.240394414 Vs 19:00:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.240414695 Vs 19:00:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.240381678 +- 0.000014647 Vs 19:00:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.240381678 +- 0.000014647 Vs BL = 2.40381678 +- 0.00014647 Tm 19:00:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.40382 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.40382 0.00015 2.40382 0.00000 19:00:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.40382 0.00015 SL = 2.4038168 +- 0.0001465 Tm^2/m^n 19:00:13 Magnet Strength Measurement Harmonic Number = 1 SL = 2.4038168 +- 0.0001465 Tm^2/m^n 19:00:13 Magnet current ramping to 780.0000 A... 19:00:36 Magnetic Field Measurement Measuring the magnet strength... 19:00:36 Integrated Voltage Measurement... 19:00:37 Magnet Current, Imag = 780.169168 A Vtrans = 7.801584 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 19:00:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.242439810 Vs 19:01:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.242411093 Vs 19:01:15 Magnet Current, Imag = 780.180148 A Vtrans = 7.801694 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 19:01:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.242397268 Vs 19:01:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.242409494 Vs 19:01:52 Magnet Current, Imag = 780.214758 A Vtrans = 7.802040 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 19:02:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.242499225 Vs 19:02:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.242457512 Vs 19:02:29 Magnet Current, Imag = 780.195728 A Vtrans = 7.801850 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 19:02:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.242425865 Vs 19:03:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.242460981 Vs 19:03:06 Magnet Current, Imag = 780.207348 A Vtrans = 7.801966 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 19:03:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.242501398 Vs 19:03:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.242462830 Vs 19:03:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.242446548 +- 0.000030317 Vs 19:03:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.242446548 +- 0.000030317 Vs BL = 2.42446548 +- 0.00030317 Tm 19:03:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.42447 0.00030 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.42447 0.00030 2.42447 0.00000 19:03:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.42447 0.00030 SL = 2.4244655 +- 0.0003032 Tm^2/m^n 19:03:51 Magnet Strength Measurement Harmonic Number = 1 SL = 2.4244655 +- 0.0003032 Tm^2/m^n 19:03:51 Magnet current ramping to 800.0000 A... 19:04:14 Magnetic Field Measurement Measuring the magnet strength... 19:04:14 Integrated Voltage Measurement... 19:04:15 Magnet Current, Imag = 800.327088 A Vtrans = 8.003163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 19:04:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.244376353 Vs 19:04:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.244359303 Vs 19:04:53 Magnet Current, Imag = 800.294268 A Vtrans = 8.002835 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 19:05:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.244408570 Vs 19:05:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.244361546 Vs 19:05:30 Magnet Current, Imag = 800.288778 A Vtrans = 8.002780 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 19:05:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.244411342 Vs 19:06:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.244410314 Vs 19:06:07 Magnet Current, Imag = 800.309338 A Vtrans = 8.002986 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 19:06:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.244368255 Vs 19:06:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.244383581 Vs 19:06:44 Magnet Current, Imag = 800.292858 A Vtrans = 8.002821 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010758 A 19:07:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.244385931 Vs 19:07:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.244339741 Vs 19:07:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.244380493 +- 0.000016936 Vs 19:07:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.244380493 +- 0.000016936 Vs BL = 2.44380493 +- 0.00016936 Tm 19:07:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.44380 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 2.44380 0.00017 2.44380 0.00000 19:07:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.44380 0.00017 SL = 2.4438049 +- 0.0001694 Tm^2/m^n 19:07:29 Magnet Strength Measurement Harmonic Number = 1 SL = 2.4438049 +- 0.0001694 Tm^2/m^n 19:07:42 Name = None, is zeroed 19:07:42 Magnet current ramping to 0.0000 A...