SLAC Magnetic Measurements Date: 11-29-2004 Time: 11:39:58 Project: klystron Magnet Type: solenoid Magnet Name: YW_Gun_Coil Serial Number: Run Number: 3 Measurement Device: Coil X Operator: sda Comment: Transverse, Coil A = 18.405, Temp = 29.9 C, Coil B is recorded as Imag, temp = 35.2 C Test Currents (A): 32.8 11:40:10 Btcoil, device being used, type = SR850 11:40:21 Stage Zeroed 11:40:21 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 11:40:22 Initial Zero Current Measurement, Imag_zero = 0.0000 A 11:40:22 Magnet current ramping to 32.8300 A... 11:41:27 Stage moved to, position = -0.260000 11:41:28 Stage Position Measurement, pos = -0.260270 m 11:41:29 Magnet Current, Imag = 32.8590 A Vtrans = 2.628716 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:41:54 Coil Voltage Measurement meas_freq = 29.998800 Hz, meas_v_mag = 0.000004 V, meas_v_ph = 118.290000 deg freq = 29.998800 Hz, v_amp = 0.000006 V, v_ph = 28.290000 deg 11:41:54 Transverse Field Calculation freq = 29.998800 Hz, v_amp = 0.000006 V, v_ph = 28.290000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000024 T, THsp = -28.290000 deg 11:42:04 Stage moved to, position = -0.240000 11:42:06 Stage Position Measurement, pos = -0.240995 m 11:42:07 Magnet Current, Imag = 32.8588 A Vtrans = 2.628705 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:42:42 Coil Voltage Measurement meas_freq = 29.995900 Hz, meas_v_mag = 0.000004 V, meas_v_ph = 116.562000 deg freq = 29.995900 Hz, v_amp = 0.000006 V, v_ph = 26.562000 deg 11:42:42 Transverse Field Calculation freq = 29.995900 Hz, v_amp = 0.000006 V, v_ph = 26.562000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000022 T, THsp = -26.562000 deg 11:42:53 Stage moved to, position = -0.220000 11:42:54 Stage Position Measurement, pos = -0.221000 m 11:42:55 Magnet Current, Imag = 32.8593 A Vtrans = 2.628741 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:43:33 Coil Voltage Measurement meas_freq = 29.998800 Hz, meas_v_mag = 0.000005 V, meas_v_ph = 124.212000 deg freq = 29.998800 Hz, v_amp = 0.000007 V, v_ph = 34.212000 deg 11:43:33 Transverse Field Calculation freq = 29.998800 Hz, v_amp = 0.000007 V, v_ph = 34.212000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000026 T, THsp = -34.212000 deg 11:43:44 Stage moved to, position = -0.200000 11:43:45 Stage Position Measurement, pos = -0.200940 m 11:43:47 Magnet Current, Imag = 32.8585 A Vtrans = 2.628683 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:44:11 Coil Voltage Measurement meas_freq = 29.999700 Hz, meas_v_mag = 0.000005 V, meas_v_ph = 131.148000 deg freq = 29.999700 Hz, v_amp = 0.000006 V, v_ph = 41.148000 deg 11:44:11 Transverse Field Calculation freq = 29.999700 Hz, v_amp = 0.000006 V, v_ph = 41.148000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000025 T, THsp = -41.148000 deg 11:44:21 Stage moved to, position = -0.180000 11:44:23 Stage Position Measurement, pos = -0.180785 m 11:44:24 Magnet Current, Imag = 32.8586 A Vtrans = 2.628691 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:44:49 Coil Voltage Measurement meas_freq = 29.996900 Hz, meas_v_mag = 0.000005 V, meas_v_ph = 144.276000 deg freq = 29.996900 Hz, v_amp = 0.000007 V, v_ph = 54.276000 deg 11:44:49 Transverse Field Calculation freq = 29.996900 Hz, v_amp = 0.000007 V, v_ph = 54.276000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000026 T, THsp = -54.276000 deg 11:44:59 Stage moved to, position = -0.160000 11:45:01 Stage Position Measurement, pos = -0.160790 m 11:45:02 Magnet Current, Imag = 32.8581 A Vtrans = 2.628648 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:45:37 Coil Voltage Measurement meas_freq = 30.002600 Hz, meas_v_mag = 0.000007 V, meas_v_ph = 142.434000 deg freq = 30.002600 Hz, v_amp = 0.000009 V, v_ph = 52.434000 deg 11:45:37 Transverse Field Calculation freq = 30.002600 Hz, v_amp = 0.000009 V, v_ph = 52.434000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000037 T, THsp = -52.434000 deg 11:45:47 Stage moved to, position = -0.140000 11:45:49 Stage Position Measurement, pos = -0.140785 m 11:45:50 Magnet Current, Imag = 32.8583 A Vtrans = 2.628662 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:46:14 Coil Voltage Measurement meas_freq = 29.998800 Hz, meas_v_mag = 0.000005 V, meas_v_ph = 152.700000 deg freq = 29.998800 Hz, v_amp = 0.000007 V, v_ph = 62.700000 deg 11:46:14 Transverse Field Calculation freq = 29.998800 Hz, v_amp = 0.000007 V, v_ph = 62.700000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000028 T, THsp = -62.700000 deg 11:46:24 Stage moved to, position = -0.120000 11:46:26 Stage Position Measurement, pos = -0.120720 m 11:46:27 Magnet Current, Imag = 32.8585 A Vtrans = 2.628683 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:46:51 Coil Voltage Measurement meas_freq = 29.996900 Hz, meas_v_mag = 0.000006 V, meas_v_ph = 157.620000 deg freq = 29.996900 Hz, v_amp = 0.000009 V, v_ph = 67.620000 deg 11:46:51 Transverse Field Calculation freq = 29.996900 Hz, v_amp = 0.000009 V, v_ph = 67.620000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000035 T, THsp = -67.620000 deg 11:47:01 Stage moved to, position = -0.100000 11:47:03 Stage Position Measurement, pos = -0.100720 m 11:47:04 Magnet Current, Imag = 32.8582 A Vtrans = 2.628659 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:47:27 Coil Voltage Measurement meas_freq = 29.994000 Hz, meas_v_mag = 0.000007 V, meas_v_ph = -166.692000 deg freq = 29.994000 Hz, v_amp = 0.000010 V, v_ph = 103.308000 deg 11:47:27 Transverse Field Calculation freq = 29.994000 Hz, v_amp = 0.000010 V, v_ph = 103.308000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000038 T, THsp = -103.308000 deg 11:47:37 Stage moved to, position = -0.080000 11:47:39 Stage Position Measurement, pos = -0.080720 m 11:47:40 Magnet Current, Imag = 32.8586 A Vtrans = 2.628685 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:48:04 Coil Voltage Measurement meas_freq = 29.999700 Hz, meas_v_mag = 0.000020 V, meas_v_ph = -154.548000 deg freq = 29.999700 Hz, v_amp = 0.000028 V, v_ph = 115.452000 deg 11:48:04 Transverse Field Calculation freq = 29.999700 Hz, v_amp = 0.000028 V, v_ph = 115.452000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000108 T, THsp = -115.452000 deg 11:48:14 Stage moved to, position = -0.060000 11:48:16 Stage Position Measurement, pos = -0.060735 m 11:48:17 Magnet Current, Imag = 32.8587 A Vtrans = 2.628693 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:48:41 Coil Voltage Measurement meas_freq = 29.997800 Hz, meas_v_mag = 0.000013 V, meas_v_ph = -150.348000 deg freq = 29.997800 Hz, v_amp = 0.000018 V, v_ph = 119.652000 deg 11:48:41 Transverse Field Calculation freq = 29.997800 Hz, v_amp = 0.000018 V, v_ph = 119.652000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000071 T, THsp = -119.652000 deg 11:48:51 Stage moved to, position = -0.040000 11:48:53 Stage Position Measurement, pos = -0.040740 m 11:48:54 Magnet Current, Imag = 32.8582 A Vtrans = 2.628654 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:49:17 Coil Voltage Measurement meas_freq = 29.995900 Hz, meas_v_mag = 0.000008 V, meas_v_ph = -127.152000 deg freq = 29.995900 Hz, v_amp = 0.000012 V, v_ph = 142.848000 deg 11:49:17 Transverse Field Calculation freq = 29.995900 Hz, v_amp = 0.000012 V, v_ph = 142.848000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000046 T, THsp = -142.848000 deg 11:49:28 Stage moved to, position = -0.020000 11:49:29 Stage Position Measurement, pos = -0.020705 m 11:49:30 Magnet Current, Imag = 32.8577 A Vtrans = 2.628615 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:49:53 Coil Voltage Measurement meas_freq = 29.995000 Hz, meas_v_mag = 0.000007 V, meas_v_ph = 70.806000 deg freq = 29.995000 Hz, v_amp = 0.000010 V, v_ph = -19.194000 deg 11:49:53 Transverse Field Calculation freq = 29.995000 Hz, v_amp = 0.000010 V, v_ph = -19.194000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000037 T, THsp = 19.194000 deg 11:50:04 Stage moved to, position = 0.000000 11:50:05 Stage Position Measurement, pos = -0.000650 m 11:50:07 Magnet Current, Imag = 32.8578 A Vtrans = 2.628621 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:50:29 Coil Voltage Measurement meas_freq = 30.004500 Hz, meas_v_mag = 0.000009 V, meas_v_ph = 55.332000 deg freq = 30.004500 Hz, v_amp = 0.000013 V, v_ph = -34.668000 deg 11:50:29 Transverse Field Calculation freq = 30.004500 Hz, v_amp = 0.000013 V, v_ph = -34.668000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000050 T, THsp = 34.668000 deg 11:50:40 Stage moved to, position = 0.020000 11:50:41 Stage Position Measurement, pos = 0.019385 m 11:50:43 Magnet Current, Imag = 32.8579 A Vtrans = 2.628633 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:51:06 Coil Voltage Measurement meas_freq = 29.998800 Hz, meas_v_mag = 0.000010 V, meas_v_ph = 37.746000 deg freq = 29.998800 Hz, v_amp = 0.000015 V, v_ph = -52.254000 deg 11:51:06 Transverse Field Calculation freq = 29.998800 Hz, v_amp = 0.000015 V, v_ph = -52.254000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000057 T, THsp = 52.254000 deg 11:51:17 Stage moved to, position = 0.040000 11:51:18 Stage Position Measurement, pos = 0.039425 m 11:51:20 Magnet Current, Imag = 32.8579 A Vtrans = 2.628634 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:51:43 Coil Voltage Measurement meas_freq = 30.002600 Hz, meas_v_mag = 0.000012 V, meas_v_ph = 6.990000 deg freq = 30.002600 Hz, v_amp = 0.000017 V, v_ph = -83.010000 deg 11:51:43 Transverse Field Calculation freq = 30.002600 Hz, v_amp = 0.000017 V, v_ph = -83.010000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000065 T, THsp = 83.010000 deg 11:51:53 Stage moved to, position = 0.060000 11:51:55 Stage Position Measurement, pos = 0.059465 m 11:51:56 Magnet Current, Imag = 32.8580 A Vtrans = 2.628644 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:52:19 Coil Voltage Measurement meas_freq = 30.003500 Hz, meas_v_mag = 0.000007 V, meas_v_ph = -5.304000 deg freq = 30.003500 Hz, v_amp = 0.000009 V, v_ph = -95.304000 deg 11:52:19 Transverse Field Calculation freq = 30.003500 Hz, v_amp = 0.000009 V, v_ph = -95.304000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000036 T, THsp = 95.304000 deg 11:52:29 Stage moved to, position = 0.080000 11:52:31 Stage Position Measurement, pos = 0.079460 m 11:52:32 Magnet Current, Imag = 32.8578 A Vtrans = 2.628624 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:52:56 Coil Voltage Measurement meas_freq = 29.995000 Hz, meas_v_mag = 0.000005 V, meas_v_ph = -24.522000 deg freq = 29.995000 Hz, v_amp = 0.000008 V, v_ph = -114.522000 deg 11:52:56 Transverse Field Calculation freq = 29.995000 Hz, v_amp = 0.000008 V, v_ph = -114.522000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000030 T, THsp = 114.522000 deg 11:53:07 Stage moved to, position = 0.100000 11:53:08 Stage Position Measurement, pos = 0.099485 m 11:53:10 Magnet Current, Imag = 32.8577 A Vtrans = 2.628616 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:53:45 Coil Voltage Measurement meas_freq = 29.998800 Hz, meas_v_mag = 0.000004 V, meas_v_ph = -52.596000 deg freq = 29.998800 Hz, v_amp = 0.000005 V, v_ph = -142.596000 deg 11:53:45 Transverse Field Calculation freq = 29.998800 Hz, v_amp = 0.000005 V, v_ph = -142.596000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000021 T, THsp = 142.596000 deg 11:53:55 Stage moved to, position = 0.120000 11:53:57 Stage Position Measurement, pos = 0.119475 m 11:53:58 Magnet Current, Imag = 32.8575 A Vtrans = 2.628604 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:54:34 Coil Voltage Measurement meas_freq = 30.002600 Hz, meas_v_mag = 0.000004 V, meas_v_ph = -101.766000 deg freq = 30.002600 Hz, v_amp = 0.000005 V, v_ph = 168.234000 deg 11:54:34 Transverse Field Calculation freq = 30.002600 Hz, v_amp = 0.000005 V, v_ph = 168.234000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000020 T, THsp = -168.234000 deg 11:54:44 Stage moved to, position = 0.140000 11:54:46 Stage Position Measurement, pos = 0.139495 m 11:54:47 Magnet Current, Imag = 32.8580 A Vtrans = 2.628642 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:55:10 Coil Voltage Measurement meas_freq = 29.998800 Hz, meas_v_mag = 0.000004 V, meas_v_ph = -61.236000 deg freq = 29.998800 Hz, v_amp = 0.000006 V, v_ph = -151.236000 deg 11:55:10 Transverse Field Calculation freq = 29.998800 Hz, v_amp = 0.000006 V, v_ph = -151.236000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000024 T, THsp = 151.236000 deg 11:55:20 Stage moved to, position = 0.160000 11:55:22 Stage Position Measurement, pos = 0.159530 m 11:55:23 Magnet Current, Imag = 32.8580 A Vtrans = 2.628638 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:55:58 Coil Voltage Measurement meas_freq = 29.994000 Hz, meas_v_mag = 0.000004 V, meas_v_ph = -97.122000 deg freq = 29.994000 Hz, v_amp = 0.000005 V, v_ph = 172.878000 deg 11:55:58 Transverse Field Calculation freq = 29.994000 Hz, v_amp = 0.000005 V, v_ph = 172.878000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000020 T, THsp = -172.878000 deg 11:56:08 Stage moved to, position = 0.180000 11:56:10 Stage Position Measurement, pos = 0.179615 m 11:56:11 Magnet Current, Imag = 32.8568 A Vtrans = 2.628542 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:56:34 Coil Voltage Measurement meas_freq = 29.999700 Hz, meas_v_mag = 0.000006 V, meas_v_ph = -84.210000 deg freq = 29.999700 Hz, v_amp = 0.000008 V, v_ph = -174.210000 deg 11:56:34 Transverse Field Calculation freq = 29.999700 Hz, v_amp = 0.000008 V, v_ph = -174.210000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000033 T, THsp = 174.210000 deg 11:56:44 Stage moved to, position = 0.200000 11:56:46 Stage Position Measurement, pos = 0.199670 m 11:56:47 Magnet Current, Imag = 32.8572 A Vtrans = 2.628579 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:57:11 Coil Voltage Measurement meas_freq = 29.994000 Hz, meas_v_mag = 0.000005 V, meas_v_ph = -82.686000 deg freq = 29.994000 Hz, v_amp = 0.000006 V, v_ph = -172.686000 deg 11:57:11 Transverse Field Calculation freq = 29.994000 Hz, v_amp = 0.000006 V, v_ph = -172.686000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000025 T, THsp = 172.686000 deg 11:57:21 Stage moved to, position = 0.220000 11:57:23 Stage Position Measurement, pos = 0.219725 m 11:57:24 Magnet Current, Imag = 32.8572 A Vtrans = 2.628575 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:57:48 Coil Voltage Measurement meas_freq = 29.998800 Hz, meas_v_mag = 0.000006 V, meas_v_ph = -81.534000 deg freq = 29.998800 Hz, v_amp = 0.000009 V, v_ph = -171.534000 deg 11:57:48 Transverse Field Calculation freq = 29.998800 Hz, v_amp = 0.000009 V, v_ph = -171.534000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000034 T, THsp = 171.534000 deg 11:57:59 Stage moved to, position = 0.240000 11:58:00 Stage Position Measurement, pos = 0.239770 m 11:58:01 Magnet Current, Imag = 32.8572 A Vtrans = 2.628579 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:58:25 Coil Voltage Measurement meas_freq = 30.001600 Hz, meas_v_mag = 0.000005 V, meas_v_ph = -58.884000 deg freq = 30.001600 Hz, v_amp = 0.000007 V, v_ph = -148.884000 deg 11:58:25 Transverse Field Calculation freq = 30.001600 Hz, v_amp = 0.000007 V, v_ph = -148.884000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000026 T, THsp = 148.884000 deg 11:58:36 Stage moved to, position = 0.260000 11:58:37 Stage Position Measurement, pos = 0.259775 m 11:58:39 Magnet Current, Imag = 32.8570 A Vtrans = 2.628561 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:59:13 Coil Voltage Measurement meas_freq = 30.000700 Hz, meas_v_mag = 0.000003 V, meas_v_ph = -79.116000 deg freq = 30.000700 Hz, v_amp = 0.000005 V, v_ph = -169.116000 deg 11:59:13 Transverse Field Calculation freq = 30.000700 Hz, v_amp = 0.000005 V, v_ph = -169.116000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000018 T, THsp = 169.116000 deg 12:00:11 Stage moved to, position = 0.000000 12:00:12 Magnet current ramping to 0.0000 A...