SLAC Magnetic Measurements Date: 02-13-2007 Time: 16:14:45 Project: Klystron Magnet Type: solenoid Magnet Name: PEPII-SN112 Serial Number: Run Number: 2 Measurement Device: Coil_2 Operator: sda Comment: Bt vs z, collector end, I2-11 = 0.0 A, I1 = 0.0 A, Bucking = 0.0 Test Currents (A): 0.0 16:14:56 Btcoil, device being used, type = SR850 16:15:07 Stage Zeroed 16:15:07 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 16:15:09 Initial Zero Current Measurement, Imag_zero = 0.0000 A 16:15:09 Magnet current ramping to 0.0000 A... 16:15:29 Move Stage, position = -0.050000 16:15:30 Stage Position Measurement, pos = -0.0500000 m 16:15:32 Magnet Current, Imag = -0.0040 A Vtrans = -0.000040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:55 Coil Voltage Measurement meas_freq = 13.159300 Hz, meas_v_mag = 0.000356 V, meas_v_ph = 151.200000 deg freq = 13.159300 Hz, v_amp = 0.000503 V, v_ph = 61.200000 deg 16:15:55 Transverse Field Calculation freq = 13.159300 Hz, v_amp = 0.000503 V, v_ph = 61.200000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -61.200000 deg 16:16:11 Move Stage, position = 0.000000 16:16:12 Stage Position Measurement, pos = 0.0000000 m 16:16:13 Magnet Current, Imag = -0.0041 A Vtrans = -0.000041 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:16:36 Coil Voltage Measurement meas_freq = 13.150200 Hz, meas_v_mag = 0.000278 V, meas_v_ph = 147.528000 deg freq = 13.150200 Hz, v_amp = 0.000394 V, v_ph = 57.528000 deg 16:16:36 Transverse Field Calculation freq = 13.150200 Hz, v_amp = 0.000394 V, v_ph = 57.528000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = -57.528000 deg 16:16:52 Move Stage, position = 0.050000 16:16:53 Stage Position Measurement, pos = 0.0500000 m 16:16:55 Magnet Current, Imag = -0.0040 A Vtrans = -0.000040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:18 Coil Voltage Measurement meas_freq = 13.150700 Hz, meas_v_mag = 0.000236 V, meas_v_ph = 143.166000 deg freq = 13.150700 Hz, v_amp = 0.000334 V, v_ph = 53.166000 deg 16:17:18 Transverse Field Calculation freq = 13.150700 Hz, v_amp = 0.000334 V, v_ph = 53.166000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000011 T, THsp = -53.166000 deg 16:17:33 Move Stage, position = 0.100000 16:17:34 Stage Position Measurement, pos = 0.1000000 m 16:17:36 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:59 Coil Voltage Measurement meas_freq = 13.152600 Hz, meas_v_mag = 0.000223 V, meas_v_ph = 139.896000 deg freq = 13.152600 Hz, v_amp = 0.000315 V, v_ph = 49.896000 deg 16:17:59 Transverse Field Calculation freq = 13.152600 Hz, v_amp = 0.000315 V, v_ph = 49.896000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000010 T, THsp = -49.896000 deg 16:18:15 Move Stage, position = 0.150000 16:18:16 Stage Position Measurement, pos = 0.1500000 m 16:18:18 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:40 Coil Voltage Measurement meas_freq = 13.156400 Hz, meas_v_mag = 0.000230 V, meas_v_ph = 138.576000 deg freq = 13.156400 Hz, v_amp = 0.000325 V, v_ph = 48.576000 deg 16:18:40 Transverse Field Calculation freq = 13.156400 Hz, v_amp = 0.000325 V, v_ph = 48.576000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000011 T, THsp = -48.576000 deg 16:18:56 Move Stage, position = 0.200000 16:18:57 Stage Position Measurement, pos = 0.2000000 m 16:18:59 Magnet Current, Imag = -0.0040 A Vtrans = -0.000040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:22 Coil Voltage Measurement meas_freq = 13.159300 Hz, meas_v_mag = 0.000243 V, meas_v_ph = 138.096000 deg freq = 13.159300 Hz, v_amp = 0.000344 V, v_ph = 48.096000 deg 16:19:22 Transverse Field Calculation freq = 13.159300 Hz, v_amp = 0.000344 V, v_ph = 48.096000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000011 T, THsp = -48.096000 deg 16:19:37 Move Stage, position = 0.250000 16:19:38 Stage Position Measurement, pos = 0.2500000 m 16:19:40 Magnet Current, Imag = -0.0040 A Vtrans = -0.000040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:03 Coil Voltage Measurement meas_freq = 13.151600 Hz, meas_v_mag = 0.000264 V, meas_v_ph = 139.452000 deg freq = 13.151600 Hz, v_amp = 0.000374 V, v_ph = 49.452000 deg 16:20:03 Transverse Field Calculation freq = 13.151600 Hz, v_amp = 0.000374 V, v_ph = 49.452000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000012 T, THsp = -49.452000 deg 16:20:19 Move Stage, position = 0.300000 16:20:20 Stage Position Measurement, pos = 0.3000000 m 16:20:22 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:44 Coil Voltage Measurement meas_freq = 13.156400 Hz, meas_v_mag = 0.000280 V, meas_v_ph = 140.034000 deg freq = 13.156400 Hz, v_amp = 0.000397 V, v_ph = 50.034000 deg 16:20:44 Transverse Field Calculation freq = 13.156400 Hz, v_amp = 0.000397 V, v_ph = 50.034000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = -50.034000 deg 16:21:00 Move Stage, position = 0.350000 16:21:01 Stage Position Measurement, pos = 0.3500000 m 16:21:03 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:21:26 Coil Voltage Measurement meas_freq = 13.154500 Hz, meas_v_mag = 0.000299 V, meas_v_ph = 141.606000 deg freq = 13.154500 Hz, v_amp = 0.000422 V, v_ph = 51.606000 deg 16:21:26 Transverse Field Calculation freq = 13.154500 Hz, v_amp = 0.000422 V, v_ph = 51.606000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000014 T, THsp = -51.606000 deg 16:21:41 Move Stage, position = 0.400000 16:21:42 Stage Position Measurement, pos = 0.4000000 m 16:21:44 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:07 Coil Voltage Measurement meas_freq = 13.155500 Hz, meas_v_mag = 0.000311 V, meas_v_ph = 141.210000 deg freq = 13.155500 Hz, v_amp = 0.000440 V, v_ph = 51.210000 deg 16:22:07 Transverse Field Calculation freq = 13.155500 Hz, v_amp = 0.000440 V, v_ph = 51.210000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000014 T, THsp = -51.210000 deg 16:22:23 Move Stage, position = 0.450000 16:22:24 Stage Position Measurement, pos = 0.4500000 m 16:22:26 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:22:48 Coil Voltage Measurement meas_freq = 13.158300 Hz, meas_v_mag = 0.000317 V, meas_v_ph = 142.038000 deg freq = 13.158300 Hz, v_amp = 0.000449 V, v_ph = 52.038000 deg 16:22:48 Transverse Field Calculation freq = 13.158300 Hz, v_amp = 0.000449 V, v_ph = 52.038000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000014 T, THsp = -52.038000 deg 16:23:04 Move Stage, position = 0.500000 16:23:05 Stage Position Measurement, pos = 0.5000000 m 16:23:07 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:23:30 Coil Voltage Measurement meas_freq = 13.116400 Hz, meas_v_mag = 0.000322 V, meas_v_ph = 141.900000 deg freq = 13.116400 Hz, v_amp = 0.000456 V, v_ph = 51.900000 deg 16:23:30 Transverse Field Calculation freq = 13.116400 Hz, v_amp = 0.000456 V, v_ph = 51.900000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -51.900000 deg 16:23:46 Move Stage, position = 0.550000 16:23:47 Stage Position Measurement, pos = 0.5500000 m 16:23:48 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:11 Coil Voltage Measurement meas_freq = 13.155500 Hz, meas_v_mag = 0.000339 V, meas_v_ph = 145.146000 deg freq = 13.155500 Hz, v_amp = 0.000480 V, v_ph = 55.146000 deg 16:24:11 Transverse Field Calculation freq = 13.155500 Hz, v_amp = 0.000480 V, v_ph = 55.146000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -55.146000 deg 16:24:27 Move Stage, position = 0.600000 16:24:28 Stage Position Measurement, pos = 0.6000000 m 16:24:30 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:24:53 Coil Voltage Measurement meas_freq = 13.148800 Hz, meas_v_mag = 0.000339 V, meas_v_ph = 144.474000 deg freq = 13.148800 Hz, v_amp = 0.000480 V, v_ph = 54.474000 deg 16:24:53 Transverse Field Calculation freq = 13.148800 Hz, v_amp = 0.000480 V, v_ph = 54.474000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -54.474000 deg 16:25:08 Move Stage, position = 0.650000 16:25:10 Stage Position Measurement, pos = 0.6500000 m 16:25:12 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:25:34 Coil Voltage Measurement meas_freq = 13.159300 Hz, meas_v_mag = 0.000343 V, meas_v_ph = 146.820000 deg freq = 13.159300 Hz, v_amp = 0.000485 V, v_ph = 56.820000 deg 16:25:35 Transverse Field Calculation freq = 13.159300 Hz, v_amp = 0.000485 V, v_ph = 56.820000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -56.820000 deg 16:25:51 Move Stage, position = 0.700000 16:25:52 Stage Position Measurement, pos = 0.7000000 m 16:25:54 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:26:17 Coil Voltage Measurement meas_freq = 13.148300 Hz, meas_v_mag = 0.000348 V, meas_v_ph = 146.292000 deg freq = 13.148300 Hz, v_amp = 0.000492 V, v_ph = 56.292000 deg 16:26:17 Transverse Field Calculation freq = 13.148300 Hz, v_amp = 0.000492 V, v_ph = 56.292000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -56.292000 deg 16:26:33 Move Stage, position = 0.750000 16:26:34 Stage Position Measurement, pos = 0.7500000 m 16:26:35 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:26:58 Coil Voltage Measurement meas_freq = 13.157400 Hz, meas_v_mag = 0.000352 V, meas_v_ph = 147.048000 deg freq = 13.157400 Hz, v_amp = 0.000497 V, v_ph = 57.048000 deg 16:26:58 Transverse Field Calculation freq = 13.157400 Hz, v_amp = 0.000497 V, v_ph = 57.048000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -57.048000 deg 16:27:14 Move Stage, position = 0.800000 16:27:15 Stage Position Measurement, pos = 0.8000000 m 16:27:17 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:27:40 Coil Voltage Measurement meas_freq = 13.158800 Hz, meas_v_mag = 0.000354 V, meas_v_ph = 147.858000 deg freq = 13.158800 Hz, v_amp = 0.000501 V, v_ph = 57.858000 deg 16:27:40 Transverse Field Calculation freq = 13.158800 Hz, v_amp = 0.000501 V, v_ph = 57.858000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -57.858000 deg 16:27:55 Move Stage, position = 0.850000 16:27:56 Stage Position Measurement, pos = 0.8500000 m 16:27:58 Magnet Current, Imag = -0.0040 A Vtrans = -0.000040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:28:21 Coil Voltage Measurement meas_freq = 13.145900 Hz, meas_v_mag = 0.000359 V, meas_v_ph = 150.420000 deg freq = 13.145900 Hz, v_amp = 0.000508 V, v_ph = 60.420000 deg 16:28:21 Transverse Field Calculation freq = 13.145900 Hz, v_amp = 0.000508 V, v_ph = 60.420000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -60.420000 deg 16:28:37 Move Stage, position = 0.900000 16:28:38 Stage Position Measurement, pos = 0.9000000 m 16:28:40 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:29:02 Coil Voltage Measurement meas_freq = 13.155500 Hz, meas_v_mag = 0.000353 V, meas_v_ph = 148.548000 deg freq = 13.155500 Hz, v_amp = 0.000499 V, v_ph = 58.548000 deg 16:29:02 Transverse Field Calculation freq = 13.155500 Hz, v_amp = 0.000499 V, v_ph = 58.548000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -58.548000 deg 16:29:18 Move Stage, position = 0.950000 16:29:19 Stage Position Measurement, pos = 0.9500000 m 16:29:21 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:29:44 Coil Voltage Measurement meas_freq = 13.155900 Hz, meas_v_mag = 0.000350 V, meas_v_ph = 149.070000 deg freq = 13.155900 Hz, v_amp = 0.000494 V, v_ph = 59.070000 deg 16:29:44 Transverse Field Calculation freq = 13.155900 Hz, v_amp = 0.000494 V, v_ph = 59.070000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -59.070000 deg 16:30:00 Move Stage, position = 1.000000 16:30:01 Stage Position Measurement, pos = 1.0000000 m 16:30:02 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:30:25 Coil Voltage Measurement meas_freq = 13.153100 Hz, meas_v_mag = 0.000344 V, meas_v_ph = 150.438000 deg freq = 13.153100 Hz, v_amp = 0.000487 V, v_ph = 60.438000 deg 16:30:25 Transverse Field Calculation freq = 13.153100 Hz, v_amp = 0.000487 V, v_ph = 60.438000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -60.438000 deg 16:30:41 Move Stage, position = 1.050000 16:30:42 Stage Position Measurement, pos = 1.0500000 m 16:30:44 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:07 Coil Voltage Measurement meas_freq = 13.150200 Hz, meas_v_mag = 0.000339 V, meas_v_ph = 151.086000 deg freq = 13.150200 Hz, v_amp = 0.000479 V, v_ph = 61.086000 deg 16:31:07 Transverse Field Calculation freq = 13.150200 Hz, v_amp = 0.000479 V, v_ph = 61.086000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -61.086000 deg 16:31:22 Move Stage, position = 1.100000 16:31:23 Stage Position Measurement, pos = 1.1000000 m 16:31:25 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:31:48 Coil Voltage Measurement meas_freq = 13.155500 Hz, meas_v_mag = 0.000335 V, meas_v_ph = 151.896000 deg freq = 13.155500 Hz, v_amp = 0.000474 V, v_ph = 61.896000 deg 16:31:48 Transverse Field Calculation freq = 13.155500 Hz, v_amp = 0.000474 V, v_ph = 61.896000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -61.896000 deg 16:32:04 Move Stage, position = 1.150000 16:32:05 Stage Position Measurement, pos = 1.1500000 m 16:32:07 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:29 Coil Voltage Measurement meas_freq = 13.151600 Hz, meas_v_mag = 0.000331 V, meas_v_ph = 153.126000 deg freq = 13.151600 Hz, v_amp = 0.000468 V, v_ph = 63.126000 deg 16:32:29 Transverse Field Calculation freq = 13.151600 Hz, v_amp = 0.000468 V, v_ph = 63.126000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -63.126000 deg 16:32:45 Move Stage, position = 1.200000 16:32:46 Stage Position Measurement, pos = 1.2000000 m 16:32:48 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:11 Coil Voltage Measurement meas_freq = 13.157400 Hz, meas_v_mag = 0.000326 V, meas_v_ph = 154.974000 deg freq = 13.157400 Hz, v_amp = 0.000461 V, v_ph = 64.974000 deg 16:33:11 Transverse Field Calculation freq = 13.157400 Hz, v_amp = 0.000461 V, v_ph = 64.974000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -64.974000 deg 16:33:27 Move Stage, position = 1.250000 16:33:28 Stage Position Measurement, pos = 1.2500000 m 16:33:29 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:52 Coil Voltage Measurement meas_freq = 13.155500 Hz, meas_v_mag = 0.000325 V, meas_v_ph = 156.414000 deg freq = 13.155500 Hz, v_amp = 0.000459 V, v_ph = 66.414000 deg 16:33:52 Transverse Field Calculation freq = 13.155500 Hz, v_amp = 0.000459 V, v_ph = 66.414000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -66.414000 deg 16:34:08 Move Stage, position = 1.300000 16:34:09 Stage Position Measurement, pos = 1.3000000 m 16:34:11 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:34:34 Coil Voltage Measurement meas_freq = 13.154500 Hz, meas_v_mag = 0.000324 V, meas_v_ph = 158.694000 deg freq = 13.154500 Hz, v_amp = 0.000459 V, v_ph = 68.694000 deg 16:34:34 Transverse Field Calculation freq = 13.154500 Hz, v_amp = 0.000459 V, v_ph = 68.694000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -68.694000 deg 16:34:49 Move Stage, position = 1.350000 16:34:50 Stage Position Measurement, pos = 1.3500000 m 16:34:52 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:15 Coil Voltage Measurement meas_freq = 13.157400 Hz, meas_v_mag = 0.000329 V, meas_v_ph = 160.746000 deg freq = 13.157400 Hz, v_amp = 0.000465 V, v_ph = 70.746000 deg 16:35:15 Transverse Field Calculation freq = 13.157400 Hz, v_amp = 0.000465 V, v_ph = 70.746000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -70.746000 deg 16:35:31 Move Stage, position = 1.400000 16:35:32 Stage Position Measurement, pos = 1.4000000 m 16:35:34 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:35:56 Coil Voltage Measurement meas_freq = 13.156900 Hz, meas_v_mag = 0.000335 V, meas_v_ph = 163.482000 deg freq = 13.156900 Hz, v_amp = 0.000474 V, v_ph = 73.482000 deg 16:35:56 Transverse Field Calculation freq = 13.156900 Hz, v_amp = 0.000474 V, v_ph = 73.482000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -73.482000 deg 16:36:12 Move Stage, position = 1.450000 16:36:13 Stage Position Measurement, pos = 1.4500000 m 16:36:15 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:36:38 Coil Voltage Measurement meas_freq = 13.155500 Hz, meas_v_mag = 0.000341 V, meas_v_ph = 165.780000 deg freq = 13.155500 Hz, v_amp = 0.000482 V, v_ph = 75.780000 deg 16:36:38 Transverse Field Calculation freq = 13.155500 Hz, v_amp = 0.000482 V, v_ph = 75.780000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -75.780000 deg 16:36:53 Move Stage, position = 1.500000 16:36:54 Stage Position Measurement, pos = 1.5000000 m 16:36:56 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:37:19 Coil Voltage Measurement meas_freq = 13.158800 Hz, meas_v_mag = 0.000350 V, meas_v_ph = 169.674000 deg freq = 13.158800 Hz, v_amp = 0.000495 V, v_ph = 79.674000 deg 16:37:19 Transverse Field Calculation freq = 13.158800 Hz, v_amp = 0.000495 V, v_ph = 79.674000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -79.674000 deg 16:37:35 Move Stage, position = 1.550000 16:37:36 Stage Position Measurement, pos = 1.5500000 m 16:37:38 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:38:00 Coil Voltage Measurement meas_freq = 13.161200 Hz, meas_v_mag = 0.000352 V, meas_v_ph = 170.976000 deg freq = 13.161200 Hz, v_amp = 0.000498 V, v_ph = 80.976000 deg 16:38:00 Transverse Field Calculation freq = 13.161200 Hz, v_amp = 0.000498 V, v_ph = 80.976000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -80.976000 deg 16:38:16 Move Stage, position = 1.600000 16:38:17 Stage Position Measurement, pos = 1.6000000 m 16:38:19 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:38:42 Coil Voltage Measurement meas_freq = 13.158800 Hz, meas_v_mag = 0.000362 V, meas_v_ph = 174.048000 deg freq = 13.158800 Hz, v_amp = 0.000512 V, v_ph = 84.048000 deg 16:38:42 Transverse Field Calculation freq = 13.158800 Hz, v_amp = 0.000512 V, v_ph = 84.048000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000017 T, THsp = -84.048000 deg 16:38:58 Move Stage, position = 1.650000 16:38:59 Stage Position Measurement, pos = 1.6500000 m 16:39:00 Magnet Current, Imag = -0.0038 A Vtrans = -0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:39:23 Coil Voltage Measurement meas_freq = 13.159800 Hz, meas_v_mag = 0.000376 V, meas_v_ph = 177.870000 deg freq = 13.159800 Hz, v_amp = 0.000532 V, v_ph = 87.870000 deg 16:39:23 Transverse Field Calculation freq = 13.159800 Hz, v_amp = 0.000532 V, v_ph = 87.870000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000017 T, THsp = -87.870000 deg 16:39:39 Move Stage, position = 1.700000 16:39:40 Stage Position Measurement, pos = 1.7000000 m 16:39:42 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:40:03 Coil Voltage Measurement meas_freq = 13.161700 Hz, meas_v_mag = 0.000381 V, meas_v_ph = 179.214000 deg freq = 13.161700 Hz, v_amp = 0.000538 V, v_ph = 89.214000 deg 16:40:03 Transverse Field Calculation freq = 13.161700 Hz, v_amp = 0.000538 V, v_ph = 89.214000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000017 T, THsp = -89.214000 deg 16:40:19 Move Stage, position = 1.750000 16:40:20 Stage Position Measurement, pos = 1.7500000 m 16:40:22 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:40:43 Coil Voltage Measurement meas_freq = 13.159800 Hz, meas_v_mag = 0.000382 V, meas_v_ph = 179.916000 deg freq = 13.159800 Hz, v_amp = 0.000540 V, v_ph = 89.916000 deg 16:40:44 Transverse Field Calculation freq = 13.159800 Hz, v_amp = 0.000540 V, v_ph = 89.916000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000017 T, THsp = -89.916000 deg 16:40:59 Move Stage, position = 1.800000 16:41:00 Stage Position Measurement, pos = 1.8000000 m 16:41:02 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:41:24 Coil Voltage Measurement meas_freq = 13.157400 Hz, meas_v_mag = 0.000394 V, meas_v_ph = -178.260000 deg freq = 13.157400 Hz, v_amp = 0.000557 V, v_ph = 91.740000 deg 16:41:24 Transverse Field Calculation freq = 13.157400 Hz, v_amp = 0.000557 V, v_ph = 91.740000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000018 T, THsp = -91.740000 deg 16:41:39 Move Stage, position = 1.850000 16:41:40 Stage Position Measurement, pos = 1.8500000 m 16:41:42 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:42:04 Coil Voltage Measurement meas_freq = 13.162600 Hz, meas_v_mag = 0.000414 V, meas_v_ph = -176.406000 deg freq = 13.162600 Hz, v_amp = 0.000585 V, v_ph = 93.594000 deg 16:42:04 Transverse Field Calculation freq = 13.162600 Hz, v_amp = 0.000585 V, v_ph = 93.594000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000019 T, THsp = -93.594000 deg 16:42:20 Move Stage, position = 1.900000 16:42:21 Stage Position Measurement, pos = 1.9000000 m 16:42:23 Magnet Current, Imag = -0.0039 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:42:44 Coil Voltage Measurement meas_freq = 13.158800 Hz, meas_v_mag = 0.000436 V, meas_v_ph = -176.064000 deg freq = 13.158800 Hz, v_amp = 0.000616 V, v_ph = 93.936000 deg 16:42:44 Transverse Field Calculation freq = 13.158800 Hz, v_amp = 0.000616 V, v_ph = 93.936000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000020 T, THsp = -93.936000 deg 16:49:10 Move Stage, position = 0.000000 16:49:14 Magnet current ramping to 0.0000 A...