SLAC Magnetic Measurements Date: 05-03-2006 Time: 14:59:45 Project: Klstron Magnet Type: solenoid Magnet Name: PEPII-SN110 Serial Number: Run Number: 1 Measurement Device: Coil 2 Operator: sda Comment: Bt vs z, collector end, I2-11 = 36.6 A, I1 = 25.6 A, Bucking = 0.0 A. Test Currents (A): 36.6 14:59:56 Btcoil, device being used, type = SR850 15:00:09 Stage Zeroed 15:00:09 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 15:00:10 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:00:10 Magnet current ramping to 36.6000 A... 15:01:11 Move Stage, position = -0.050000 15:01:13 Stage Position Measurement, pos = -0.0499950 m 15:01:14 Magnet Current, Imag = 36.7358 A Vtrans = 0.367358 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:01:35 Coil Voltage Measurement meas_freq = 13.062000 Hz, meas_v_mag = 0.000163 V, meas_v_ph = 177.540000 deg freq = 13.062000 Hz, v_amp = 0.000231 V, v_ph = 87.540000 deg 15:01:35 Transverse Field Calculation freq = 13.062000 Hz, v_amp = 0.000231 V, v_ph = 87.540000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -87.540000 deg 15:01:50 Move Stage, position = 0.000000 15:01:52 Stage Position Measurement, pos = -0.0006950 m 15:01:53 Magnet Current, Imag = 36.7406 A Vtrans = 0.367406 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:02:13 Coil Voltage Measurement meas_freq = 13.062500 Hz, meas_v_mag = 0.000160 V, meas_v_ph = 68.166000 deg freq = 13.062500 Hz, v_amp = 0.000226 V, v_ph = -21.834000 deg 15:02:13 Transverse Field Calculation freq = 13.062500 Hz, v_amp = 0.000226 V, v_ph = -21.834000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = 21.834000 deg 15:02:28 Move Stage, position = 0.050000 15:02:30 Stage Position Measurement, pos = 0.0493900 m 15:02:31 Magnet Current, Imag = 36.7438 A Vtrans = 0.367438 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:02:50 Coil Voltage Measurement meas_freq = 13.060600 Hz, meas_v_mag = 0.000905 V, meas_v_ph = 19.860000 deg freq = 13.060600 Hz, v_amp = 0.001280 V, v_ph = -70.140000 deg 15:02:50 Transverse Field Calculation freq = 13.060600 Hz, v_amp = 0.001280 V, v_ph = -70.140000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000041 T, THsp = 70.140000 deg 15:03:05 Move Stage, position = 0.100000 15:03:07 Stage Position Measurement, pos = 0.0994150 m 15:03:08 Magnet Current, Imag = 36.7469 A Vtrans = 0.367469 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:03:28 Coil Voltage Measurement meas_freq = 13.055800 Hz, meas_v_mag = 0.000408 V, meas_v_ph = -10.842000 deg freq = 13.055800 Hz, v_amp = 0.000577 V, v_ph = -100.842000 deg 15:03:28 Transverse Field Calculation freq = 13.055800 Hz, v_amp = 0.000577 V, v_ph = -100.842000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000019 T, THsp = 100.842000 deg 15:03:43 Move Stage, position = 0.150000 15:03:45 Stage Position Measurement, pos = 0.1494550 m 15:03:46 Magnet Current, Imag = 36.7490 A Vtrans = 0.367490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:04:07 Coil Voltage Measurement meas_freq = 13.064900 Hz, meas_v_mag = 0.000244 V, meas_v_ph = -30.066000 deg freq = 13.064900 Hz, v_amp = 0.000345 V, v_ph = -120.066000 deg 15:04:07 Transverse Field Calculation freq = 13.064900 Hz, v_amp = 0.000345 V, v_ph = -120.066000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000011 T, THsp = 120.066000 deg 15:04:22 Move Stage, position = 0.200000 15:04:24 Stage Position Measurement, pos = 0.1996050 m 15:04:25 Magnet Current, Imag = 36.7510 A Vtrans = 0.367510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:04:46 Coil Voltage Measurement meas_freq = 13.060600 Hz, meas_v_mag = 0.000244 V, meas_v_ph = -13.536000 deg freq = 13.060600 Hz, v_amp = 0.000346 V, v_ph = -103.536000 deg 15:04:46 Transverse Field Calculation freq = 13.060600 Hz, v_amp = 0.000346 V, v_ph = -103.536000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000011 T, THsp = 103.536000 deg 15:05:01 Move Stage, position = 0.250000 15:05:02 Stage Position Measurement, pos = 0.2496500 m 15:05:04 Magnet Current, Imag = 36.7527 A Vtrans = 0.367527 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:05:25 Coil Voltage Measurement meas_freq = 13.058200 Hz, meas_v_mag = 0.000291 V, meas_v_ph = 8.376000 deg freq = 13.058200 Hz, v_amp = 0.000411 V, v_ph = -81.624000 deg 15:05:25 Transverse Field Calculation freq = 13.058200 Hz, v_amp = 0.000411 V, v_ph = -81.624000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = 81.624000 deg 15:05:40 Move Stage, position = 0.300000 15:05:41 Stage Position Measurement, pos = 0.2997200 m 15:05:43 Magnet Current, Imag = 36.7541 A Vtrans = 0.367541 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:06:04 Coil Voltage Measurement meas_freq = 13.057700 Hz, meas_v_mag = 0.000279 V, meas_v_ph = 24.798000 deg freq = 13.057700 Hz, v_amp = 0.000395 V, v_ph = -65.202000 deg 15:06:04 Transverse Field Calculation freq = 13.057700 Hz, v_amp = 0.000395 V, v_ph = -65.202000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = 65.202000 deg 15:06:19 Move Stage, position = 0.350000 15:06:21 Stage Position Measurement, pos = 0.3498050 m 15:06:22 Magnet Current, Imag = 36.7284 A Vtrans = 0.367284 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:06:42 Coil Voltage Measurement meas_freq = 13.059100 Hz, meas_v_mag = 0.000221 V, meas_v_ph = 39.870000 deg freq = 13.059100 Hz, v_amp = 0.000313 V, v_ph = -50.130000 deg 15:06:42 Transverse Field Calculation freq = 13.059100 Hz, v_amp = 0.000313 V, v_ph = -50.130000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000010 T, THsp = 50.130000 deg 15:06:58 Move Stage, position = 0.400000 15:06:59 Stage Position Measurement, pos = 0.3998500 m 15:07:01 Magnet Current, Imag = 36.7294 A Vtrans = 0.367294 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:07:22 Coil Voltage Measurement meas_freq = 13.060600 Hz, meas_v_mag = 0.000148 V, meas_v_ph = 61.368000 deg freq = 13.060600 Hz, v_amp = 0.000209 V, v_ph = -28.632000 deg 15:07:22 Transverse Field Calculation freq = 13.060600 Hz, v_amp = 0.000209 V, v_ph = -28.632000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = 28.632000 deg 15:07:37 Move Stage, position = 0.450000 15:07:39 Stage Position Measurement, pos = 0.4498000 m 15:07:40 Magnet Current, Imag = 36.7300 A Vtrans = 0.367300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:08:15 Coil Voltage Measurement meas_freq = 13.057700 Hz, meas_v_mag = 0.000140 V, meas_v_ph = 93.888000 deg freq = 13.057700 Hz, v_amp = 0.000198 V, v_ph = 3.888000 deg 15:08:15 Transverse Field Calculation freq = 13.057700 Hz, v_amp = 0.000198 V, v_ph = 3.888000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000006 T, THsp = -3.888000 deg 15:08:30 Move Stage, position = 0.500000 15:08:32 Stage Position Measurement, pos = 0.4998700 m 15:08:33 Magnet Current, Imag = 36.7304 A Vtrans = 0.367304 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:08:55 Coil Voltage Measurement meas_freq = 13.056800 Hz, meas_v_mag = 0.000159 V, meas_v_ph = 90.576000 deg freq = 13.056800 Hz, v_amp = 0.000225 V, v_ph = 0.576000 deg 15:08:55 Transverse Field Calculation freq = 13.056800 Hz, v_amp = 0.000225 V, v_ph = 0.576000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -0.576000 deg 15:09:10 Move Stage, position = 0.550000 15:09:12 Stage Position Measurement, pos = 0.5500350 m 15:09:13 Magnet Current, Imag = 36.7583 A Vtrans = 0.367583 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:09:47 Coil Voltage Measurement meas_freq = 13.055800 Hz, meas_v_mag = 0.000194 V, meas_v_ph = 68.748000 deg freq = 13.055800 Hz, v_amp = 0.000274 V, v_ph = -21.252000 deg 15:09:47 Transverse Field Calculation freq = 13.055800 Hz, v_amp = 0.000274 V, v_ph = -21.252000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000009 T, THsp = 21.252000 deg 15:10:02 Move Stage, position = 0.600000 15:10:04 Stage Position Measurement, pos = 0.6000500 m 15:10:05 Magnet Current, Imag = 36.7589 A Vtrans = 0.367589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:10:26 Coil Voltage Measurement meas_freq = 13.054400 Hz, meas_v_mag = 0.000191 V, meas_v_ph = 78.324000 deg freq = 13.054400 Hz, v_amp = 0.000270 V, v_ph = -11.676000 deg 15:10:26 Transverse Field Calculation freq = 13.054400 Hz, v_amp = 0.000270 V, v_ph = -11.676000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000009 T, THsp = 11.676000 deg 15:10:41 Move Stage, position = 0.650000 15:10:43 Stage Position Measurement, pos = 0.6500150 m 15:10:44 Magnet Current, Imag = 36.7291 A Vtrans = 0.367291 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:11:06 Coil Voltage Measurement meas_freq = 13.049600 Hz, meas_v_mag = 0.000151 V, meas_v_ph = 99.378000 deg freq = 13.049600 Hz, v_amp = 0.000213 V, v_ph = 9.378000 deg 15:11:06 Transverse Field Calculation freq = 13.049600 Hz, v_amp = 0.000213 V, v_ph = 9.378000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -9.378000 deg 15:11:21 Move Stage, position = 0.700000 15:11:23 Stage Position Measurement, pos = 0.7001150 m 15:11:24 Magnet Current, Imag = 36.7280 A Vtrans = 0.367280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:11:45 Coil Voltage Measurement meas_freq = 13.056800 Hz, meas_v_mag = 0.000200 V, meas_v_ph = 146.784000 deg freq = 13.056800 Hz, v_amp = 0.000282 V, v_ph = 56.784000 deg 15:11:45 Transverse Field Calculation freq = 13.056800 Hz, v_amp = 0.000282 V, v_ph = 56.784000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000009 T, THsp = -56.784000 deg 15:12:00 Move Stage, position = 0.750000 15:12:02 Stage Position Measurement, pos = 0.7501900 m 15:12:03 Magnet Current, Imag = 36.7275 A Vtrans = 0.367275 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:12:24 Coil Voltage Measurement meas_freq = 13.060100 Hz, meas_v_mag = 0.000355 V, meas_v_ph = 159.480000 deg freq = 13.060100 Hz, v_amp = 0.000502 V, v_ph = 69.480000 deg 15:12:24 Transverse Field Calculation freq = 13.060100 Hz, v_amp = 0.000502 V, v_ph = 69.480000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -69.480000 deg 15:12:39 Move Stage, position = 0.800000 15:12:40 Stage Position Measurement, pos = 0.8002050 m 15:12:42 Magnet Current, Imag = 36.7267 A Vtrans = 0.367267 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:13:02 Coil Voltage Measurement meas_freq = 13.059100 Hz, meas_v_mag = 0.000449 V, meas_v_ph = 157.548000 deg freq = 13.059100 Hz, v_amp = 0.000635 V, v_ph = 67.548000 deg 15:13:02 Transverse Field Calculation freq = 13.059100 Hz, v_amp = 0.000635 V, v_ph = 67.548000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000021 T, THsp = -67.548000 deg 15:13:17 Move Stage, position = 0.850000 15:13:18 Stage Position Measurement, pos = 0.8502550 m 15:13:20 Magnet Current, Imag = 36.7263 A Vtrans = 0.367263 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:13:40 Coil Voltage Measurement meas_freq = 13.059600 Hz, meas_v_mag = 0.000443 V, meas_v_ph = 150.900000 deg freq = 13.059600 Hz, v_amp = 0.000626 V, v_ph = 60.900000 deg 15:13:40 Transverse Field Calculation freq = 13.059600 Hz, v_amp = 0.000626 V, v_ph = 60.900000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000020 T, THsp = -60.900000 deg 15:13:55 Move Stage, position = 0.900000 15:13:57 Stage Position Measurement, pos = 0.9004050 m 15:13:58 Magnet Current, Imag = 36.7260 A Vtrans = 0.367260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:14:19 Coil Voltage Measurement meas_freq = 13.058700 Hz, meas_v_mag = 0.000370 V, meas_v_ph = 146.106000 deg freq = 13.058700 Hz, v_amp = 0.000523 V, v_ph = 56.106000 deg 15:14:19 Transverse Field Calculation freq = 13.058700 Hz, v_amp = 0.000523 V, v_ph = 56.106000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000017 T, THsp = -56.106000 deg 15:14:34 Move Stage, position = 0.950000 15:14:36 Stage Position Measurement, pos = 0.9504950 m 15:14:37 Magnet Current, Imag = 36.7259 A Vtrans = 0.367259 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:15:11 Coil Voltage Measurement meas_freq = 13.056800 Hz, meas_v_mag = 0.000218 V, meas_v_ph = 137.328000 deg freq = 13.056800 Hz, v_amp = 0.000309 V, v_ph = 47.328000 deg 15:15:11 Transverse Field Calculation freq = 13.056800 Hz, v_amp = 0.000309 V, v_ph = 47.328000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000010 T, THsp = -47.328000 deg 15:15:26 Move Stage, position = 1.000000 15:15:28 Stage Position Measurement, pos = 1.0005350 m 15:15:29 Magnet Current, Imag = 36.7247 A Vtrans = 0.367247 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:04 Coil Voltage Measurement meas_freq = 13.054800 Hz, meas_v_mag = 0.000113 V, meas_v_ph = 108.870000 deg freq = 13.054800 Hz, v_amp = 0.000159 V, v_ph = 18.870000 deg 15:16:04 Transverse Field Calculation freq = 13.054800 Hz, v_amp = 0.000159 V, v_ph = 18.870000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000005 T, THsp = -18.870000 deg 15:16:19 Move Stage, position = 1.050000 15:16:21 Stage Position Measurement, pos = 1.0506200 m 15:16:22 Magnet Current, Imag = 36.7250 A Vtrans = 0.367250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:44 Coil Voltage Measurement meas_freq = 13.061000 Hz, meas_v_mag = 0.000124 V, meas_v_ph = 45.432000 deg freq = 13.061000 Hz, v_amp = 0.000176 V, v_ph = -44.568000 deg 15:16:44 Transverse Field Calculation freq = 13.061000 Hz, v_amp = 0.000176 V, v_ph = -44.568000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000006 T, THsp = 44.568000 deg 15:16:59 Move Stage, position = 1.100000 15:17:01 Stage Position Measurement, pos = 1.1007200 m 15:17:02 Magnet Current, Imag = 36.7248 A Vtrans = 0.367248 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:17:37 Coil Voltage Measurement meas_freq = 13.063000 Hz, meas_v_mag = 0.000212 V, meas_v_ph = 28.170000 deg freq = 13.063000 Hz, v_amp = 0.000299 V, v_ph = -61.830000 deg 15:17:37 Transverse Field Calculation freq = 13.063000 Hz, v_amp = 0.000299 V, v_ph = -61.830000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000010 T, THsp = 61.830000 deg 15:17:52 Move Stage, position = 1.150000 15:17:54 Stage Position Measurement, pos = 1.1507050 m 15:17:55 Magnet Current, Imag = 36.7243 A Vtrans = 0.367243 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:16 Coil Voltage Measurement meas_freq = 13.063400 Hz, meas_v_mag = 0.000255 V, meas_v_ph = 21.114000 deg freq = 13.063400 Hz, v_amp = 0.000360 V, v_ph = -68.886000 deg 15:18:16 Transverse Field Calculation freq = 13.063400 Hz, v_amp = 0.000360 V, v_ph = -68.886000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000012 T, THsp = 68.886000 deg 15:18:31 Move Stage, position = 1.200000 15:18:32 Stage Position Measurement, pos = 1.2007750 m 15:18:34 Magnet Current, Imag = 36.7259 A Vtrans = 0.367259 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:54 Coil Voltage Measurement meas_freq = 13.064400 Hz, meas_v_mag = 0.000175 V, meas_v_ph = 11.868000 deg freq = 13.064400 Hz, v_amp = 0.000247 V, v_ph = -78.132000 deg 15:18:54 Transverse Field Calculation freq = 13.064400 Hz, v_amp = 0.000247 V, v_ph = -78.132000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000008 T, THsp = 78.132000 deg 15:19:09 Move Stage, position = 1.250000 15:19:11 Stage Position Measurement, pos = 1.2509100 m 15:19:12 Magnet Current, Imag = 36.7263 A Vtrans = 0.367263 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:33 Coil Voltage Measurement meas_freq = 13.061000 Hz, meas_v_mag = 0.000076 V, meas_v_ph = -37.638000 deg freq = 13.061000 Hz, v_amp = 0.000107 V, v_ph = -127.638000 deg 15:19:33 Transverse Field Calculation freq = 13.061000 Hz, v_amp = 0.000107 V, v_ph = -127.638000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000003 T, THsp = 127.638000 deg 15:19:49 Move Stage, position = 1.300000 15:19:50 Stage Position Measurement, pos = 1.3009500 m 15:19:52 Magnet Current, Imag = 36.7273 A Vtrans = 0.367273 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:13 Coil Voltage Measurement meas_freq = 13.063000 Hz, meas_v_mag = 0.000089 V, meas_v_ph = -116.274000 deg freq = 13.063000 Hz, v_amp = 0.000126 V, v_ph = 153.726000 deg 15:20:13 Transverse Field Calculation freq = 13.063000 Hz, v_amp = 0.000126 V, v_ph = 153.726000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000004 T, THsp = -153.726000 deg 15:20:28 Move Stage, position = 1.350000 15:20:30 Stage Position Measurement, pos = 1.3510150 m 15:20:31 Magnet Current, Imag = 36.7586 A Vtrans = 0.367586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:52 Coil Voltage Measurement meas_freq = 13.061500 Hz, meas_v_mag = 0.000100 V, meas_v_ph = -128.634000 deg freq = 13.061500 Hz, v_amp = 0.000141 V, v_ph = 141.366000 deg 15:20:52 Transverse Field Calculation freq = 13.061500 Hz, v_amp = 0.000141 V, v_ph = 141.366000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000005 T, THsp = -141.366000 deg 15:21:07 Move Stage, position = 1.400000 15:21:09 Stage Position Measurement, pos = 1.4010450 m 15:21:10 Magnet Current, Imag = 36.7265 A Vtrans = 0.367265 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:45 Coil Voltage Measurement meas_freq = 13.065800 Hz, meas_v_mag = 0.000071 V, meas_v_ph = -113.124000 deg freq = 13.065800 Hz, v_amp = 0.000100 V, v_ph = 156.876000 deg 15:21:45 Transverse Field Calculation freq = 13.065800 Hz, v_amp = 0.000100 V, v_ph = 156.876000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000003 T, THsp = -156.876000 deg 15:22:00 Move Stage, position = 1.450000 15:22:02 Stage Position Measurement, pos = 1.4511700 m 15:22:03 Magnet Current, Imag = 36.7259 A Vtrans = 0.367259 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:22:38 Coil Voltage Measurement meas_freq = 13.065300 Hz, meas_v_mag = 0.000085 V, meas_v_ph = -98.820000 deg freq = 13.065300 Hz, v_amp = 0.000120 V, v_ph = 171.180000 deg 15:22:38 Transverse Field Calculation freq = 13.065300 Hz, v_amp = 0.000120 V, v_ph = 171.180000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000004 T, THsp = -171.180000 deg 15:22:53 Move Stage, position = 1.500000 15:22:55 Stage Position Measurement, pos = 1.5012100 m 15:22:56 Magnet Current, Imag = 36.7313 A Vtrans = 0.367313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:17 Coil Voltage Measurement meas_freq = 13.064400 Hz, meas_v_mag = 0.000145 V, meas_v_ph = -118.638000 deg freq = 13.064400 Hz, v_amp = 0.000205 V, v_ph = 151.362000 deg 15:23:17 Transverse Field Calculation freq = 13.064400 Hz, v_amp = 0.000205 V, v_ph = 151.362000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -151.362000 deg 15:23:32 Move Stage, position = 1.550000 15:23:34 Stage Position Measurement, pos = 1.5511850 m 15:23:35 Magnet Current, Imag = 36.7257 A Vtrans = 0.367257 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:56 Coil Voltage Measurement meas_freq = 13.070600 Hz, meas_v_mag = 0.000245 V, meas_v_ph = -122.838000 deg freq = 13.070600 Hz, v_amp = 0.000347 V, v_ph = 147.162000 deg 15:23:56 Transverse Field Calculation freq = 13.070600 Hz, v_amp = 0.000347 V, v_ph = 147.162000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000011 T, THsp = -147.162000 deg 15:24:11 Move Stage, position = 1.600000 15:24:13 Stage Position Measurement, pos = 1.6013000 m 15:24:14 Magnet Current, Imag = 36.7257 A Vtrans = 0.367257 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:24:48 Coil Voltage Measurement meas_freq = 13.063000 Hz, meas_v_mag = 0.000284 V, meas_v_ph = -121.758000 deg freq = 13.063000 Hz, v_amp = 0.000402 V, v_ph = 148.242000 deg 15:24:48 Transverse Field Calculation freq = 13.063000 Hz, v_amp = 0.000402 V, v_ph = 148.242000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = -148.242000 deg 15:25:04 Move Stage, position = 1.650000 15:25:05 Stage Position Measurement, pos = 1.6514100 m 15:25:07 Magnet Current, Imag = 36.7247 A Vtrans = 0.367247 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:27 Coil Voltage Measurement meas_freq = 13.066800 Hz, meas_v_mag = 0.000288 V, meas_v_ph = -123.156000 deg freq = 13.066800 Hz, v_amp = 0.000407 V, v_ph = 146.844000 deg 15:25:27 Transverse Field Calculation freq = 13.066800 Hz, v_amp = 0.000407 V, v_ph = 146.844000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = -146.844000 deg 15:25:43 Move Stage, position = 1.700000 15:25:44 Stage Position Measurement, pos = 1.7014400 m 15:25:46 Magnet Current, Imag = 36.7249 A Vtrans = 0.367249 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:26:20 Coil Voltage Measurement meas_freq = 13.067700 Hz, meas_v_mag = 0.000261 V, meas_v_ph = -130.362000 deg freq = 13.067700 Hz, v_amp = 0.000370 V, v_ph = 139.638000 deg 15:26:20 Transverse Field Calculation freq = 13.067700 Hz, v_amp = 0.000370 V, v_ph = 139.638000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000012 T, THsp = -139.638000 deg 15:26:35 Move Stage, position = 1.750000 15:26:37 Stage Position Measurement, pos = 1.7515450 m 15:26:38 Magnet Current, Imag = 36.7263 A Vtrans = 0.367263 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:12 Coil Voltage Measurement meas_freq = 13.070600 Hz, meas_v_mag = 0.000275 V, meas_v_ph = -156.756000 deg freq = 13.070600 Hz, v_amp = 0.000388 V, v_ph = 113.244000 deg 15:27:12 Transverse Field Calculation freq = 13.070600 Hz, v_amp = 0.000388 V, v_ph = 113.244000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = -113.244000 deg 15:27:28 Move Stage, position = 1.800000 15:27:29 Stage Position Measurement, pos = 1.8016550 m 15:27:30 Magnet Current, Imag = 36.7265 A Vtrans = 0.367265 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:50 Coil Voltage Measurement meas_freq = 13.071500 Hz, meas_v_mag = 0.000412 V, meas_v_ph = 175.914000 deg freq = 13.071500 Hz, v_amp = 0.000583 V, v_ph = 85.914000 deg 15:27:50 Transverse Field Calculation freq = 13.071500 Hz, v_amp = 0.000583 V, v_ph = 85.914000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000019 T, THsp = -85.914000 deg 15:28:06 Move Stage, position = 1.850000 15:28:07 Stage Position Measurement, pos = 1.8516650 m 15:28:09 Magnet Current, Imag = 36.7262 A Vtrans = 0.367262 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:28 Coil Voltage Measurement meas_freq = 13.076800 Hz, meas_v_mag = 0.000499 V, meas_v_ph = 156.384000 deg freq = 13.076800 Hz, v_amp = 0.000706 V, v_ph = 66.384000 deg 15:28:29 Transverse Field Calculation freq = 13.076800 Hz, v_amp = 0.000706 V, v_ph = 66.384000 deg Coil Constant = 0.032300 (T/V0p) Transverse Field, Bt = 0.000023 T, THsp = -66.384000 deg 15:34:44 Move Stage, position = 0.000000 15:34:45 Magnet current ramping to 0.0000 A...